Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 110
Filtrar
1.
J Microsc ; 285(3): 156-166, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-32530049

RESUMEN

The mechanical behaviour of regenerated bone tissue during fracture healing is key in determining its ability to withstand physiological loads. However, the strain distribution in the newly formed tissue and how this influences the way a fracture heals it is still unclear. X-ray Computed Tomography (XCT) has been extensively used to assess the progress of mineralised tissues in regeneration and when combined with in situ mechanics and digital volume correlation (DVC) has been proven a powerful tool to understand the mechanical behaviour and full-field three-dimensional (3D) strain distribution in bone. The purpose of this study is therefore to use in situ XCT mechanics and DVC to investigate the strain distribution and load-bearing capacity in a regenerating fracture in the diaphyseal bone, using a rodent femoral fracture model stabilised by external fixation. Rat femurs with 1 mm and 2 mm osteotomy gaps were tested under in situ XCT step-wise compression in the apparent elastic region. High strain was present in the newly formed bone (εp1 and εp3 reaching 29 000 µÎµ and -43 000 µÎµ, respectively), with a wide variation and inhomogeneity of the 3D strain distribution in the regenerating tissues of the fracture gap, which is directly related to the presence of unmineralised tissue observed in histological images. The outcomes of this study will contribute in understanding natural regenerative ability of bone and its mechanical behaviour under loading.


Asunto(s)
Huesos , Fracturas del Fémur , Animales , Osteogénesis , Ratas , Tomografía Computarizada por Rayos X
2.
Bone Joint Res ; 10(10): 650-658, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34628940

RESUMEN

AIMS: This study investigates the effects of intra-articular injection of adipose-derived mesenchymal stem cells (AdMSCs) and platelet-rich plasma (PRP) on lameness, pain, and quality of life in osteoarthritic canine patients. METHODS: With informed owner consent, adipose tissue collected from adult dogs diagnosed with degenerative joint disease was enzymatically digested and cultured to passage 1. A small portion of cells (n = 4) surplus to clinical need were characterized using flow cytometry and tri-lineage differentiation. The impact and degree of osteoarthritis (OA) was assessed using the Liverpool Osteoarthritis in Dogs (LOAD) score, Modified Canine Osteoarthritis Staging Tool (mCOAST), kinetic gait analysis, and diagnostic imaging. Overall, 28 joints (25 dogs) were injected with autologous AdMSCs and PRP. The patients were followed up at two, four, eight, 12, and 24 weeks. Data were analyzed using two related-samples Wilcoxon signed-rank or Mann-Whitney U tests with statistical significance set at p < 0.05. RESULTS: AdMSCs demonstrated stem cell-like characteristics. LOAD scores were significantly lower at week 4 compared with preinjection (p = 0.021). The mCOAST improved significantly after three months (p = 0.001) and six months (p = 0.001). Asymmmetry indices decreased from four weeks post-injection and remained significantly lower at six months (p = 0.025). CONCLUSION: These improvements in quality of life, reduction in pain on examination, and improved symmetry in dogs injected with AdMSCs and PRP support the effectiveness of this combined treatment for symptom modification in canine OA for six months. Cite this article: Bone Joint Res 2021;10(10):650-658.

3.
Ann Biomed Eng ; 48(4): 1382-1395, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31974868

RESUMEN

The Intraosseous Transcutaneous Amputation Prosthesis (ITAP) offers transfemoral amputees an ambulatory method potentially reducing soft tissue complications seen with socket and stump devices. This study validated a finite element (in silico) model based on an ITAP design and investigated implant stem stiffness influence on periprosthetic femoral bone strain. Results showed good agreement in the validation of the in silico model against the in vitro results using uniaxial strain gauges and Digital Image Correlation (DIC). Using Strain Energy Density (SED) thresholds as the stimulus for adaptive bone remodelling, the validated model illustrated that: (a) bone apposition increased and resorption decreased with increasing implant stem flexibility in early stance; (b) bone apposition decreased (mean change = - 9.8%) and resorption increased (mean change = 20.3%) from distal to proximal in most stem stiffness models in early stance. By engineering the flow of force through the implant/bone (e.g. by changing material properties) these results demonstrate how periprosthetic bone remodelling, thus aseptic loosening, can be managed. This paper finds that future implant designs should be optimised for bone strain under a variety of relevant loading conditions using finite element models to maximise the chances of clinical success.


Asunto(s)
Prótesis Anclada al Hueso , Diseño de Prótesis , Simulación por Computador , Fémur , Análisis de Elementos Finitos , Humanos , Masculino , Persona de Mediana Edad , Modelos Teóricos , Estrés Mecánico
4.
J Microsc ; 277(3): 160-169, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31339556

RESUMEN

The regeneration of injured tendons and ligaments is challenging because the scaffolds needs proper mechanical properties and a biomimetic morphology. In particular, the morphological arrangement of scaffolds is a key point to drive the cells growth to properly regenerate the collagen extracellular matrix. Electrospinning is a promising technique to produce hierarchically structured nanofibrous scaffolds able to guide cells in the regeneration of the injured tissue. Moreover, the dynamic stretching in bioreactors of electrospun scaffolds had demonstrated to speed up cell shape modifications in vitro. The aim of the present study was to combine different imaging techniques such as high-resolution X-ray tomography (XCT), scanning electron microscopy (SEM), fluorescence microscopy and histology to investigate if hierarchically structured poly (L-lactic acid) and collagen electrospun scaffolds can induce morphological modifications in human fibroblasts, while cultured in static and dynamic conditions. After 7 days of parallel cultures, the results assessed that fibroblasts had proliferated on the external nanofibrous sheath of the static scaffolds, elongating themselves circumferentially. The dynamic cultures revealed a preferential axial orientation of fibroblasts growth on the external sheath. The aligned nanofibre bundles inside the hierarchical scaffolds instead, allowed a physiological distribution of the fibroblasts along the nanofibre direction. Inside the dynamic scaffolds, cells appeared thinner compared with the static counterpart. This study had demonstrated that hierarchically structured electrospun scaffolds can induce different fibroblasts morphological modifications during static and dynamic conditions, modifying their shape in the direction of the applied loads. LAY DESCRIPTION: To enhance the regeneration of injured tendons and ligaments cells need to growth on dedicated structures (scaffolds) with mechanical properties and a fibrous morphology similar to the natural tissue. In particular, the morphological organisation of scaffolds is fundamental in leading cells to colonise them, regenerating the collagen extracellular matrix. Electrospinning is a promising technique to produce fibres with a similar to the human collagen fibres, suitable to design complex scaffolds able to guide cells in the reconstruction of the natural tissue. Moreover, it is well established that the cyclic stretching of these scaffolds inside dedicated systems called bioreactors, can speed up cells growth and their shape modification. The aim of the present study was to investigate how hierarchically structured electrospun scaffolds, made of resorbable material such as poly(L-lactic acid) and collagen, could induce morphological changes in human fibroblasts, while cultured during static and dynamic conditions. These scaffolds were composed by an external electrospun membrane that grouped inside it a ring-shaped bundle, made of axially aligned nanofibres, resembling the morphological arrangement of tendon and ligament tissue. After 7 days of parallel cultures, the scaffolds were investigated using the following imaging techniques: (i) high-resolution X-ray tomography (XCT); (ii) scanning electron microscopy (SEM); (iii) fluorescence microscopy and (iv) histology. The results showed that fibroblasts were able to grow on the external nanofibrous sheath of the static scaffolds, by elongating themselves along their circumference. The dynamic cultures revealed instead a preferential axial orientation of fibroblasts grown on the external sheath. The aligned nanofibre bundles inside the hierarchical scaffolds allowed an axial distribution of the fibroblasts along the nanofibres direction. This study has demonstrated that the electrospun hierarchically structured scaffolds investigated can modify the fibroblasts morphology both in static and dynamic conditions, in relation with the direction of the applied loads.


Asunto(s)
Fibroblastos/fisiología , Ingeniería de Tejidos/métodos , Andamios del Tejido/química , Materiales Biocompatibles/química , Materiales Biomiméticos , Células Cultivadas , Colágeno/fisiología , Fibroblastos/citología , Fibroblastos/ultraestructura , Humanos , Ligamentos/patología , Microscopía Electrónica de Rastreo , Microscopía Fluorescente , Nanofibras/química , Poliésteres/química , Medicina Regenerativa , Tendones/fisiología , Tomografía por Rayos X
5.
Biomaterials ; 209: 152-162, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31048149

RESUMEN

The efficient healing of critical-sized bone defects using synthetic biomaterial-based strategies is promising but remains challenging as it requires the development of biomaterials that combine a 3D porous architecture and a robust biological activity. Bioactive glasses (BGs) are attractive candidates as they stimulate a biological response that favors osteogenesis and vascularization, but amorphous 3D porous BGs are difficult to produce because conventional compositions crystallize during processing. Here, we rationally designed a porous, strontium-releasing, bioactive glass-based scaffold (pSrBG) whose composition was tailored to deliver strontium and whose properties were optimized to retain an amorphous phase, induce tissue infiltration and encourage bone formation. The hypothesis was that it would allow the repair of a critical-sized defect in an ovine model with newly-formed bone exhibiting physiological matrix composition and structural architecture. Histological and histomorphometric analyses combined with indentation testing showed pSrBG encouraged near perfect bone-to-material contact and the formation of well-organized lamellar bone. Analysis of bone quality by a combination of Raman spectral imaging, small-angle X-ray scattering, X-ray fluorescence and focused ion beam-scanning electron microscopy demonstrated that the repaired tissue was akin to that of normal, healthy bone, and incorporated small amounts of strontium in the newly formed bone mineral. These data show the potential of pSrBG to induce an efficient repair of critical-sized bone defects and establish the importance of thorough multi-scale characterization in assessing biomaterial outcomes in large animal models.


Asunto(s)
Materiales Biocompatibles/química , Materiales Biocompatibles/uso terapéutico , Vidrio/química , Estroncio/química , Animales , Regeneración Ósea/efectos de los fármacos , Femenino , Porosidad , Ovinos , Espectrometría Raman , Andamios del Tejido/química
6.
J Microsc ; 272(3): 213-228, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30047557

RESUMEN

A micromechanical characterization of biomaterials for bone tissue engineering is essential to understand the quality of the newly regenerated bone, enabling the improvement of tissue regeneration strategies. A combination of microcomputed tomography in conjunction with in situ mechanical testing and digital volume correlation (DVC) has become a powerful technique to investigate the internal deformation of bone structure at a range of dimensional scales. However, in order to obtain accurate three-dimensional strain measurement at tissue level, high-resolution images must be acquired, and displacement/strain measurement uncertainties evaluated. The aim of this study was to optimize imaging parameters, image postprocessing and DVC settings to enhance computation based on 'zero-strain' repeated high-resolution synchrotron microCT scans of trabecular bone and bone-biomaterial systems. Low exposures to SR X-ray radiation were required to minimize irradiation-induced tissue damage, resulting in the need of advanced three-dimensional filters on the reconstructed images to reduce DVC-measured strain errors. Furthermore, the computation of strain values only in the hard phase (i.e. bone, biomaterial) allowed the exclusion of large artefacts localized in the bone marrow. This study demonstrated the suitability of a local DVC approach based on synchrotron microCT images to investigate the micromechanics of trabecular bone and bone-biomaterial composites at tissue level with a standard deviation of the errors in the region of 100 microstrain after a thorough optimization of DVC computation. LAY DESCRIPTION: Understanding the quality of newly regenerated bone after implantation of novel biomaterials is essential to improve bone tissue engineering strategies and formulation of biomaterials. The relationship between microstructure and mechanics of bone has been previously addressed combining microcomputed tomography with in situ mechanical testing. The addition of an image-based experimental technique such as digital volume correlation (DVC) allows to characterize the deformation of materials in a three-dimensional manner. However, in order to obtain accurate information at the micro-scale, high-resolution images, obtained for example by using synchrotron radiation microcomputed tomography, as well as optimization of the DVC computation are needed. This study presents the effect of different imaging parameters, image postprocessing and DVC settings for as accurate investigation of trabecular bone structure and bone-biomaterial interfaces. The results showed that when appropriate image postprocessing and DVC settings are used DVC computation results in very low strain errors. This is of vital importance for a correct understanding of the deformation in bone-biomaterial systems and the ability of such biomaterials in producing new bone comparable with the native tissue they are meant to replace.


Asunto(s)
Materiales Biocompatibles , Huesos/diagnóstico por imagen , Sincrotrones , Microtomografía por Rayos X/métodos , Humanos , Imagenología Tridimensional , Programas Informáticos
7.
Bone Joint Res ; 7(4): 289-297, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29922447

RESUMEN

OBJECTIVES: This study aimed to assess the effect of age and osteoporosis on the proliferative and differentiating capacity of bone-marrow-derived mesenchymal stem cells (MSCs) in female rats. We also discuss the role of these factors on expression and migration of cells along the C-X-C chemokine receptor type 4 (CXCR-4) / stromal derived factor 1 (SDF-1) axis. METHODS: Mesenchymal stem cells were harvested from the femora of young, adult, and osteopenic Wistar rats. Cluster of differentiation (CD) marker and CXCR-4 expression was measured using flow cytometry. Cellular proliferation was measured using Alamar Blue, osteogenic differentiation was measured using alkaline phosphatase expression and alizarin red production, and adipogenic differentiation was measured using Oil red O. Cells were incubated in Boyden chambers to quantify their migration towards SDF-1. Data was analyzed using a Student's t-test, where p-values < 0.05 were considered significant. RESULTS: CD marker expression and proliferation of the MSCs from the three groups was not significantly different. The young MSCs demonstrated significantly increased differentiation into bone and fat and superior migration towards SDF-1. The migration of SDF-1 doubled with young rats compared with the adult rats (p = 0.023) and it was four times higher when compared with cells isolated from ovariectomized (OVX) osteopenic rats (p = 0.013). CONCLUSION: Young rat MSCs are significantly more responsive to osteogenic differentiation, and, contrary to other studies, also demonstrated increased adipogenic differentiation compared with cells from adult and ostopenic rats. Young-rat-derived cells also showed superior migration towards SDF-1 compared with MSCs from OVX and adult control rats.Cite this article: A. Sanghani-Kerai, L. Osagie-Clouard, G. Blunn, M. Coathup. The influence of age and osteoporosis on bone marrow stem cells from rats. Bone Joint Res 2018;7:289-297. DOI: 10.1302/2046-3758.74.BJR-2017-0302.R1.

8.
Bone Joint J ; 100-B(4): 455-460, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-29629583

RESUMEN

Increasing innovation in rapid prototyping (RP) and additive manufacturing (AM), also known as 3D printing, is bringing about major changes in translational surgical research. This review describes the current position in the use of additive manufacturing in orthopaedic surgery. Cite this article: Bone Joint J 2018;100-B:455-60.


Asunto(s)
Procedimientos Ortopédicos/instrumentación , Impresión Tridimensional , Humanos , Atención Perioperativa/métodos
9.
Bone Joint J ; 100-B(3): 271-284, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-29589505

RESUMEN

Aims: The success of anterior cruciate ligament reconstruction (ACLR) depends on osseointegration at the graft-tunnel interface and intra-articular ligamentization. Our aim was to conduct a systematic review of clinical and preclinical studies that evaluated biological augmentation of graft healing in ACLR. Materials and Methods: In all, 1879 studies were identified across three databases. Following assessment against strict criteria, 112 studies were included (20 clinical studies; 92 animal studies). Results: Seven categories of biological interventions were identified: growth factors, biomaterials, stem cells, gene therapy, autologous tissue, biophysical/environmental, and pharmaceuticals. The methodological quality of animal studies was moderate in 97%, but only 10% used clinically relevant outcome measures. The most interventions in clinical trials target the graft-tunnel interface and are applied intraoperatively. Platelet-rich plasma is the most studied intervention, but the clinical outcomes are mixed, and the methodological quality of studies was suboptimal. Other biological therapies investigated in clinical trials include: remnant-augmented ACLR; bone substitutes; calcium phosphate-hybridized grafts; extracorporeal shockwave therapy; and adult autologus non-cultivated stem cells. Conclusion: There is extensive preclinical research supporting the use of biological therapies to augment ACLR. Further clinical studies that meet the minimum standards of reporting are required to determine whether emerging biological strategies will provide tangible benefits in patients undergoing ACLR. Cite this article: Bone Joint J 2018;100-B:271-84.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Cicatrización de Heridas/fisiología , Animales , Materiales Biocompatibles/farmacología , Sustitutos de Huesos/farmacología , Fosfatos de Calcio/farmacología , Tratamiento con Ondas de Choque Extracorpóreas , Terapia Genética , Humanos , Péptidos y Proteínas de Señalización Intercelular/farmacología , Plasma Rico en Plaquetas , Trasplante de Células Madre , Trasplante Autólogo , Cicatrización de Heridas/efectos de los fármacos
10.
Bone Joint J ; 100-B(2): 134-142, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29437054

RESUMEN

AIMS: Periprosthetic joint infection (PJI) is a serious complication of total hip arthroplasty (THA). Different bearing surface materials have different surface properties and it has been suggested that the choice of bearing surface may influence the risk of PJI after THA. The objective of this meta-analysis was to compare the rate of PJI between metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and ceramic-on-ceramic (CoC) bearings. PATIENTS AND METHODS: Electronic databases (Medline, Embase, Cochrane library, Web of Science, and Cumulative Index of Nursing and Allied Health Literature) were searched for comparative randomized and observational studies that reported the incidence of PJI for different bearing surfaces. Two investigators independently reviewed studies for eligibility, evaluated risk of bias, and performed data extraction. Meta-analysis was performed using the Mantel-Haenzel method and random-effects model in accordance with methods of the Cochrane group. RESULTS: Our search strategy revealed 2272 studies, of which 17 met the inclusion criteria and were analyzed. These comprised 11 randomized controlled trials and six observational studies. The overall quality of included studies was high but the observational studies were at high risk of bias due to inadequate adjustment for confounding factors. The overall cumulative incidence of PJI across all studies was 0.78% (1514/193 378). For each bearing combination, the overall incidence was as follows: MoP 0.85% (1353/158 430); CoP 0.38% (67/17 489); and CoC 0.53% (94/17 459). The meta-analysis showed no significant difference between the three bearing combinations in terms of risk of PJI. CONCLUSION: On the basis of the clinical studies available, there is no evidence that bearing choice influences the risk of PJI. Future research, including basic science studies and large, adequately controlled registry studies, may be helpful in determining whether implant materials play a role in determining the risk of PJI following arthroplasty surgery. Cite this article: Bone Joint J 2018;100-B:134-42.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Infecciones Relacionadas con Prótesis/etiología , Cerámica , Humanos , Incidencia , Metales , Polietileno , Diseño de Prótesis , Infecciones Relacionadas con Prótesis/epidemiología , Factores de Riesgo , Propiedades de Superficie
11.
Bone Joint Res ; 6(6): 358-365, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28576885

RESUMEN

OBJECTIVES: Cellular movement and relocalisation are important for many physiologic properties. Local mesenchymal stem cells (MSCs) from injured tissues and circulating MSCs aid in fracture healing. Cytokines and chemokines such as Stromal cell-derived factor 1(SDF-1) and its receptor chemokine receptor type 4 (CXCR4) play important roles in maintaining mobilisation, trafficking and homing of stem cells from bone marrow to the site of injury. We investigated the differences in migration of MSCs from the femurs of young, adult and ovariectomised (OVX) rats and the effect of CXCR4 over-expression on their migration. METHODS: MSCs from young, adult and OVX rats were put in a Boyden chamber to establish their migration towards SDF-1. This was compared with MSCs transfected with CXCR4, as well as MSCs differentiated to osteoblasts. RESULTS: MSCs from OVX rats migrate significantly (p < 0.05) less towards SDF-1 (9%, sd 5%) compared with MSCs from adult (15%, sd 3%) and young rats (25%, sd 4%). Cells transfected with CXCR4 migrated significantly more towards SDF-1 compared with non-transfected cells, irrespective of whether these cells were from OVX (26.5%, sd 4%), young (47%, sd 17%) or adult (21%, sd 4%) rats. Transfected MSCs differentiated to osteoblasts express CXCR4 but do not migrate towards SDF-1. CONCLUSIONS: MSC migration is impaired by age and osteoporosis in rats, and this may be associated with a significant reduction in bone formation in osteoporotic patients. The migration of stem cells can be ameliorated by upregulating CXCR4 levels which could possibly enhance fracture healing in osteoporotic patients.Cite this article: A. Sanghani-Kerai, M. Coathup, S. Samazideh, P. Kalia, L. Di Silvio, B. Idowu, G. Blunn. Osteoporosis and ageing affects the migration of stem cells and this is ameliorated by transfection with CXCR4. Bone Joint Res 2017;6:-365. DOI: 10.1302/2046-3758.66.BJR-2016-0259.R1.

12.
Bone Joint J ; 99-B(3): 393-400, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28249981

RESUMEN

AIMS: The Intraosseous Transcutaneous Amputation Prosthesis (ITAP) may improve quality of life for amputees by avoiding soft-tissue complications associated with socket prostheses and by improving sensory feedback and function. It relies on the formation of a seal between the soft tissues and the implant and currently has a flange with drilled holes to promote dermal attachment. Despite this, infection remains a significant risk. This study explored alternative strategies to enhance soft-tissue integration. MATERIALS AND METHODS: The effect of ITAP pins with a fully porous titanium alloy flange with interconnected pores on soft-tissue integration was investigated. The flanges were coated with fibronectin-functionalised hydroxyapatite and silver coatings, which have been shown to have an antibacterial effect, while also promoting viable fibroblast growth in vitro. The ITAP pins were implanted along the length of ovine tibias, and histological assessment was undertaken four weeks post-operatively. RESULTS: The porous titanium alloy flange reduced epithelial downgrowth and increased soft-tissue integration compared with the current drilled flange. The addition of coatings did not enhance these effects. CONCLUSION: These results indicate that a fully porous titanium alloy flange has the potential to increase the soft-tissue seal around ITAP and reduce susceptibility to infection compared with the current design. Cite this article: Bone Joint J 2017;99-B:393-400.


Asunto(s)
Muñones de Amputación , Miembros Artificiales , Materiales Biocompatibles Revestidos , Ajuste de Prótesis/métodos , Aleaciones , Animales , Miembros Artificiales/efectos adversos , Durapatita , Fibronectinas , Ensayo de Materiales/métodos , Oseointegración , Porosidad , Diseño de Prótesis , Infecciones Relacionadas con Prótesis/prevención & control , Ovinos , Plata , Propiedades de Superficie , Titanio
13.
Bone Joint J ; 99-B(2): 276-282, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28148673

RESUMEN

AIMS: Massive endoprostheses rely on extra-cortical bone bridging (ECBB) to enhance fixation. The aim of this study was to investigate the role of selective laser sintered (SLS) porous collars in augmenting the osseointegration of these prostheses. MATERIALS AND METHODS: The two novel designs of porous SLS collars, one with small pores (Ø700 µm, SP) and one with large pores (Ø1500 µm, LP), were compared in an ovine tibial diaphyseal model. Osseointegration of these collars was compared with that of a clinically used solid, grooved design (G). At six months post-operatively, the ovine tibias were retrieved and underwent radiological and histological analysis. RESULTS: Porous collars provided a significantly greater surface (p < 0.001) for the ingrowth of bone than the standard grooved design. Significantly greater extracortical pedicle formation was seen radiologically around the grooved design (length p = 0.002, thickness p < 0.001, surface area p = 0.002) than around the porous collars. However, the ingrowth of bone occurred from the transection site into the porous structure of both types of collar. A fivefold increase in integration was seen with the SP and a threefold increase in the LP design when compared with G (p < 0.001). CONCLUSION: SLS porous collars allow the direct ingrowth of more bone and are better than current designs which rely on surface ongrowth and ECBB. Cite this article: Bone Joint J 2017;99-B:276-82.


Asunto(s)
Materiales Biocompatibles Revestidos , Oseointegración , Prótesis e Implantes , Diseño de Prótesis , Tibia/cirugía , Animales , Durapatita , Femenino , Rayos Láser , Porosidad , Falla de Prótesis , Ovinos , Tibia/diagnóstico por imagen , Tibia/patología , Titanio
14.
Bone Joint Res ; 6(1): 14-21, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28062525

RESUMEN

Intermittently administered parathyroid hormone (PTH 1-34) has been shown to promote bone formation in both human and animal studies. The hormone and its analogues stimulate both bone formation and resorption, and as such at low doses are now in clinical use for the treatment of severe osteoporosis. By varying the duration of exposure, parathyroid hormone can modulate genes leading to increased bone formation within a so-called 'anabolic window'. The osteogenic mechanisms involved are multiple, affecting the stimulation of osteoprogenitor cells, osteoblasts, osteocytes and the stem cell niche, and ultimately leading to increased osteoblast activation, reduced osteoblast apoptosis, upregulation of Wnt/ß-catenin signalling, increased stem cell mobilisation, and mediation of the RANKL/OPG pathway. Ongoing investigation into their effect on bone formation through 'coupled' and 'uncoupled' mechanisms further underlines the impact of intermittent PTH on both cortical and cancellous bone. Given the principally catabolic actions of continuous PTH, this article reviews the skeletal actions of intermittent PTH 1-34 and the mechanisms underlying its effect. CITE THIS ARTICLE: L. Osagie-Clouard, A. Sanghani, M. Coathup, T. Briggs, M. Bostrom, G. Blunn. Parathyroid hormone 1-34 and skeletal anabolic action: The use of parathyroid hormone in bone formation. Bone Joint Res 2017;6:14-21. DOI: 10.1302/2046-3758.61.BJR-2016-0085.R1.

15.
J Biomed Mater Res B Appl Biomater ; 105(6): 1438-1446, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-27086858

RESUMEN

Polyetheretherketone (PEEK) is an alternative to metallic implants in orthopedic applications; however, PEEK is bioinert and does not osteointegrate. In this study, an accelerated neutral atom beam technique (ANAB) was employed to improve the bioactivity of PEEK. The aim was to investigate the growth of human mesenchymal stem cells (hMSCs), human osteoblasts (hOB), and skin fibroblasts (BR3G) on PEEK and ANAB PEEK. METHODS: The surface roughness and contact angle of PEEK and ANAB PEEK was measured. Cell metabolic activity, proliferation and alkaline phosphatase (ALP) was measured and cell attachment was determined by quantifying adhesion plaques with cells. RESULTS: ANAB treatment increased the surface hydrophilicity [91.74 ± 4.80° (PEEK) vs. 74.82 ± 2.70° (ANAB PEEK), p < 0.001] but did not alter the surface roughness. Metabolic activity and proliferation for all cell types significantly increased on ANAB PEEK compared to PEEK (p < 0.05). Significantly increased cell attachment was measured on ANAB PEEK surfaces. MSCs seeded on ANAB PEEK in the presence of osteogenic media, expressed increased levels of ALP compared to untreated PEEK (p < 0.05) CONCLUSION: Our results demonstrated that ANAB treatment increased the cell attachment, metabolic activity, and proliferation on PEEK. ANAB treatment may improve the osteointegration of PEEK implants. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1438-1446, 2017.


Asunto(s)
Sustitutos de Huesos/química , Fibroblastos/metabolismo , Cetonas/química , Ensayo de Materiales , Células Madre Mesenquimatosas/metabolismo , Osteoblastos/metabolismo , Polietilenglicoles/química , Benzofenonas , Adhesión Celular , Línea Celular Transformada , Fibroblastos/citología , Humanos , Células Madre Mesenquimatosas/citología , Oseointegración , Osteoblastos/citología , Polímeros
16.
Bone Joint J ; 98-B(7): 917-24, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27365469

RESUMEN

AIMS: Surgeons have commonly used modular femoral heads and stems from different manufacturers, although this is not recommended by orthopaedic companies due to the different manufacturing processes. We compared the rate of corrosion and rate of wear at the trunnion/head taper junction in two groups of retrieved hips; those with mixed manufacturers (MM) and those from the same manufacturer (SM). MATERIALS AND METHODS: We identified 151 retrieved hips with large-diameter cobalt-chromium heads; 51 of two designs that had been paired with stems from different manufacturers (MM) and 100 of seven designs paired with stems from the same manufacturer (SM). We determined the severity of corrosion with the Goldberg corrosion score and the volume of material loss at the head/stem junction. We used multivariable statistical analysis to determine if there was a significant difference between the two groups. RESULTS: We found no significant difference in the corrosion scores of the two groups. The median rate of material loss at the head/stem junction for the MM and SM groups were 0.39 mm(3)/year (0.00 to 4.73) and 0.46 mm(3)/year (0.00 to 6.71) respectively; this difference was not significant after controlling for confounding factors (p = 0.06). CONCLUSION: The use of stems with heads of another manufacturer does not appear to affect the amount of metal lost from the surfaces between these two components at total hip arthroplasty. Other surgical, implant and patient factors should be considered when determining the mechanisms of failure of large diameter metal-on-metal hip arthroplasties. Cite this article: Bone Joint J 2016;98-B:917-24.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Corrosión , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Diseño de Prótesis , Falla de Prótesis , Adulto , Anciano , Cromo , Aleaciones de Cromo , Cobalto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Titanio
17.
Bone Joint J ; 98-B(5): 579-84, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27143725

RESUMEN

There is increasing global awareness of adverse reactions to metal debris and elevated serum metal ion concentrations following the use of second generation metal-on-metal total hip arthroplasties. The high incidence of these complications can be largely attributed to corrosion at the head-neck interface. Severe corrosion of the taper is identified most commonly in association with larger diameter femoral heads. However, there is emerging evidence of varying levels of corrosion observed in retrieved components with smaller diameter femoral heads. This same mechanism of galvanic and mechanically-assisted crevice corrosion has been observed in metal-on-polyethylene and ceramic components, suggesting an inherent biomechanical problem with current designs of the head-neck interface. We provide a review of the fundamental questions and answers clinicians and researchers must understand regarding corrosion of the taper, and its relevance to current orthopaedic practice. Cite this article: Bone Joint J 2016;98-B:579-84.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Corrosión , Prótesis de Cadera/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Diseño de Prótesis , Artroplastia de Reemplazo de Cadera/métodos , Humanos , Falla de Prótesis
18.
Eur Cell Mater ; 31: 250-63, 2016 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-27071735

RESUMEN

We explored the osseointegration potential of two macroporous titanium surfaces obtained using fast plasma sintering (FPS): Ti macroporous structures with 400-600 µmØ pores (TiMac400) and 850-1000 µmØ pores (TiMac850). They were compared against two surfaces currently in clinical use: Ti-Growth® and air plasma spray (Ti-Y367). Each surface was tested, once placed over a Ti-alloy and once onto a CoCr bulk substrate. Implants were placed in medial femoral condyles in 24 sheep. Samples were explanted at four and eight weeks after surgery. Push-out loads were measured using a material-testing system. Bone contact and ingrowth were assessed by histomorphometry and SEM and EDX analyses. Histology showed early osseointegration for all the surfaces tested. At 8 weeks, TiMac400, TiMac850 and Ti-Growth® showed deep bone ingrowth and extended colonisation with newly formed bone. The mechanical push-out force was equal in all tested surfaces. Plasma spray surfaces showed greater bone-implant contact and higher level of pores colonisation with new bone than FPS produced surfaces. However, the void pore area in FPS specimens was significantly higher, yet the FPS porous surfaces allowed a deeper osseointegration of bone to implant. FPS manufactured specimens showed similar osseointegration potential to the plasma spray surfaces for orthopaedic implants. FPS is a useful technology for manufacturing macroporous titanium surfaces. Furthermore, its capability to combine two implantable materials, using bulk CoCr with macroporous titanium surfaces, could be of interest as it enables designers to conceive and manufacture innovative components. FPS delivers functional graded materials components with macroporous structures optimised for osseointegration.


Asunto(s)
Materiales Biocompatibles/farmacología , Desarrollo Óseo/efectos de los fármacos , Materiales Biocompatibles Revestidos/farmacología , Ensayo de Materiales/métodos , Oseointegración/fisiología , Prótesis e Implantes , Titanio/farmacología , Animales , Microscopía Electrónica de Rastreo , Oseointegración/efectos de los fármacos , Porosidad , Ovinos , Espectrometría por Rayos X , Propiedades de Superficie , Titanio/metabolismo
19.
Bone Joint J ; 98-B(4): 504-11, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27037433

RESUMEN

AIMS: To assess the extent of osteointegration in two designs of shoulder resurfacing implants. Bony integration to the Copeland cylindrical central stem design and the Epoca RH conical-crown design were compared. PATIENTS AND METHODS: Implants retrieved from six patients in each group were pair-matched. Mean time to revision surgery of Copeland implants was 37 months (standard deviation (sd) 23; 14 to 72) and Epoca RH 38 months (sd 28; 12 to 84). The mean age of patients investigated was 66 years (sd 4; 59 to 71) and 58 years (sd 17; 31 to 73) in the Copeland and Epoca RH groups respectively. None of these implants were revised for loosening. RESULTS: Increased osteointegration was measured under the cup in the Copeland implant group with limited bone seen in direct contact with the central stem. Bone adjacent to the Epoca RH implants was more uniform. CONCLUSION: This difference in the distribution of bone-implant contact and bone formation was attributed to the Epoca implant's conical crown, which is positioned in more dense peripheral bone. The use of a central stem may not be necessary provided there is adequate peripheral fixation within good quality humeral bone. TAKE HOME MESSAGE: Poor osteointegration of cementless surface replacement shoulder prosthesis may be improved by implant design.


Asunto(s)
Artroplastia de Reemplazo , Oseointegración , Articulación del Hombro/cirugía , Anciano , Densidad Ósea , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Articulación del Hombro/patología , Factores de Tiempo
20.
Bone Joint J ; 97-B(9): 1183-91, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26330583

RESUMEN

The long term biological effects of wear products following total hip arthroplasty (THA) are unclear. However, the indications for THA are expanding, with increasingly younger patients undergoing the procedure. This prospective, randomised study compared two groups of patients undergoing THA after being randomised to receive one of two different bearing surfaces: metal-on-polyethylene (MoP) n = 22 and metal-on-metal (MoM) n = 23. We investigated the relationship between three variables: bearing surface (MoP vs MoM), whole blood levels of chromium (Cr) and cobalt (Co) and chromosomal aberrations in peripheral lymphocyte pre-operatively and at one, two and five years post-surgery. Our results demonstrated significantly higher mean cobalt and chromium (Co and Cr) blood levels in the MoM group at all follow-up points following surgery (p < 0.01), but there were no significant differences in the chromosomal aberration indices between MoM and MoP at two or five years (two years: p = 0.56, p = 0.08, p = 0.91, p = 0.51 and five years: p = 0.086, p = 0.73, p = 0.06, p = 0.34) for translocations, breaks, loss and gain of chromosomes respectively. Regression analysis showed a strong linear relationship between Cr levels and the total chromosomal aberration indices in the MoM group (R(2) = 0.90016), but this was not as strong for Co (R(2) = 0.68991). In the MoP group, the analysis revealed a poor relationship between Cr levels and the total chromosomal aberration indices (R(2) = 0.23908) but a slightly stronger relationship for Co (R(2) = 0.64292). Across both groups, Spearman's correlation detected no overall association between Co and Cr levels and each of the studied chromosomal aberrations. There remains no clear indication which THA bearing couple is the most biocompatible, especially in young active patients. While THA continues to be very successful at alleviating pain and restoring function, the long-term biological implications of the procedure still require further scrutiny.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cromo/sangre , Aberraciones Cromosómicas , Cobalto/sangre , Prótesis de Cadera/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Cromo/farmacología , Cobalto/farmacología , Femenino , Humanos , Linfocitos/efectos de los fármacos , Masculino , Persona de Mediana Edad , Polietileno , Periodo Posoperatorio , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...