Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
bioRxiv ; 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38948770

RESUMEN

The axon initial segment (AIS) constitutes not only the site of action potential initiation, but also a hub for activity-dependent modulation of output generation. Recent studies shedding light on AIS function used predominantly post-hoc approaches since no robust murine in vivo live reporters exist. Here, we introduce a reporter line in which the AIS is intrinsically labeled by an ankyrin-G-GFP fusion protein activated by Cre recombinase, tagging the native Ank3 gene. Using confocal, superresolution, and two-photon microscopy as well as whole-cell patch-clamp recordings in vitro, ex vivo, and in vivo, we confirm that the subcellular scaffold of the AIS and electrophysiological parameters of labeled cells remain unchanged. We further uncover rapid AIS remodeling following increased network activity in this model system, as well as highly reproducible in vivo labeling of AIS over weeks. This novel reporter line allows longitudinal studies of AIS modulation and plasticity in vivo in real-time and thus provides a unique approach to study subcellular plasticity in a broad range of applications.

2.
J Med Chem ; 67(15): 12632-12659, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39023313

RESUMEN

Activin receptor-like kinases 1-7 (ALK1-7) regulate a complex network of SMAD-independent as well as SMAD-dependent signaling pathways. One of the widely used inhibitors for functional investigations of these processes, in particular for bone morphogenetic protein (BMP) signaling, is LDN-193189. However, LDN-193189 has insufficient kinome-wide selectivity complicating its use in cellular target validation assays. Herein, we report the identification and comprehensive characterization of two chemically distinct highly selective inhibitors of ALK1 and ALK2, M4K2234 and MU1700, along with their negative controls. We show that both MU1700 and M4K2234 efficiently block the BMP pathway via selective in cellulo inhibition of ALK1/2 kinases and exhibit favorable in vivo profiles in mice. MU1700 is highly brain penetrant and shows remarkably high accumulation in the brain. These high-quality orthogonal chemical probes offer the selectivity required to become widely used tools for in vitro and in vivo investigation of BMP signaling.


Asunto(s)
Receptores de Activinas Tipo II , Animales , Humanos , Ratones , Receptores de Activinas Tipo II/metabolismo , Receptores de Activinas Tipo II/antagonistas & inhibidores , Receptores de Activinas Tipo I/antagonistas & inhibidores , Receptores de Activinas Tipo I/metabolismo , Inhibidores de Proteínas Quinasas/farmacología , Inhibidores de Proteínas Quinasas/química , Relación Estructura-Actividad , Transducción de Señal/efectos de los fármacos , Descubrimiento de Drogas , Sondas Moleculares/química , Proteínas Morfogenéticas Óseas/metabolismo , Pirazoles/química , Pirazoles/farmacología , Pirazoles/síntesis química
3.
Radiat Oncol ; 19(1): 96, 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39080735

RESUMEN

BACKGROUND: In this work, we compare input level, feature level and decision level data fusion techniques for automatic detection of clinically significant prostate lesions (csPCa). METHODS: Multiple deep learning CNN architectures were developed using the Unet as the baseline. The CNNs use both multiparametric MRI images (T2W, ADC, and High b-value) and quantitative clinical data (prostate specific antigen (PSA), PSA density (PSAD), prostate gland volume & gross tumor volume (GTV)), and only mp-MRI images (n = 118), as input. In addition, co-registered ground truth data from whole mount histopathology images (n = 22) were used as a test set for evaluation. RESULTS: The CNNs achieved for early/intermediate / late level fusion a precision of 0.41/0.51/0.61, recall value of 0.18/0.22/0.25, an average precision of 0.13 / 0.19 / 0.27, and F scores of 0.55/0.67/ 0.76. Dice Sorensen Coefficient (DSC) was used to evaluate the influence of combining mpMRI with parametric clinical data for the detection of csPCa. We compared the DSC between the predictions of CNN's trained with mpMRI and parametric clinical and the CNN's trained with only mpMRI images as input with the ground truth. We obtained a DSC of data 0.30/0.34/0.36 and 0.26/0.33/0.34 respectively. Additionally, we evaluated the influence of each mpMRI input channel for the task of csPCa detection and obtained a DSC of 0.14 / 0.25 / 0.28. CONCLUSION: The results show that the decision level fusion network performs better for the task of prostate lesion detection. Combining mpMRI data with quantitative clinical data does not show significant differences between these networks (p = 0.26/0.62/0.85). The results show that CNNs trained with all mpMRI data outperform CNNs with less input channels which is consistent with current clinical protocols where the same input is used for PI-RADS lesion scoring. TRIAL REGISTRATION: The trial was registered retrospectively at the German Register for Clinical Studies (DRKS) under proposal number Nr. 476/14 & 476/19.


Asunto(s)
Aprendizaje Profundo , Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Anciano , Interpretación de Imagen Asistida por Computador/métodos , Persona de Mediana Edad
4.
Invest Radiol ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747489

RESUMEN

PURPOSE: Intraoral coils (IOCs) in magnetic resonance imaging (MRI) significantly improve the signal-to-noise ratio compared with conventional extraoral coils. To assess the safety of IOCs, we propose a 2-step procedure to evaluate radiofrequency-induced heating of IOCs and compare maximum temperature increases in 3 different types of IOCs. METHODS: The 2-step safety assessment consists of electric field measurements and simulations to identify local hotspots followed by temperature measurements during MRI. With this method, 3 different coil types (inductively coupled IFC, transmit/receive tLoop, and receive-only tLoopRx) were tested at 1.5 T and 3 T for both tuned and detuned coil states. High SAR and regular MRI protocols were applied for 2 coil positions. RESULTS: The measured E field maps display distinct hotspots for all tuned IOCs, which were reduced by at least 40-fold when the IOCs were detuned. Maximum temperature rise was higher when the coils were positioned at the periphery of the phantom with the coil planes parallel to B0. When neither active nor passive detuning was applied, maximum temperature increase of ΔT = 1.3/0.5/1.8 K was found for IFC/tLoop/tLoopRx coils. Hotspots detected by E field measurements, and simulations were consistent. In the simulations, the results were different for homogeneous phantoms compared with full anatomical models. The 2-step test procedure is applicable to different coil types. CONCLUSIONS: The results indicate that a risk for radiofrequency-induced heating exists for tuned IOCs, so that adequate detuning circuits need to be integrated in the coils to ensure safe operation.

5.
Sci Rep ; 14(1): 1869, 2024 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-38253776

RESUMEN

Pigs are frequently applied as animal models in cardiovascular research due to their anatomical and physiological similarity to humans. For study planning and refinement, precise knowledge of the cardioaortic dimensions is essential. In a retrospective single-center study, the cardioaortic dimensions and left ventricular function of German Landrace pigs were assessed using cardiac MRI. All parameters were compared between male and female pigs and analyzed for correlation with body weight. In total, 15 pigs were included (7 male and 8 female, weight 60.9 ± 7.0 kg). The left ventricle revealed an end-diastolic diameter of 50.5 ± 4.4 mm and an ejection fraction of 51.2 ± 9.8%. The diameters of the ascending and descending aorta were 21.3 ± 2.3 and 16.2 ± 1.4 mm, respectively. There were no significant differences between male and female pigs, except that males had a smaller end-diastolic left ventricular volume (p = 0.041). A moderate correlation was found between body weight and the aortic annulus diameter (R = 0.57, p = 0.027). In conclusion, cardiac MRI allows precise quantification of porcine cardioaortic dimensions. For medical device testing, size differences between pigs and humans should be considered.


Asunto(s)
Corazón , Imagen por Resonancia Magnética , Humanos , Femenino , Masculino , Porcinos , Animales , Estudios Retrospectivos , Corazón/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Peso Corporal
6.
Sci Rep ; 14(1): 606, 2024 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-38182761

RESUMEN

Magnetic resonance imaging (MRI) provides a multitude of techniques to detect and characterize myocardial infarction. To correlate MRI findings with histology, in most cases terminal animal studies are performed; however, precise extraction and spatial correlation of myocardial tissue samples to MRI image data is difficult. In this proof of concept study, we present a 3D-printing technique to facilitate the extraction of tissue samples from myocardial regions. Initially, seven pig hearts embedded in formaldehyde were imaged on a clinical 3 T system to define biopsy targets on high resolution ex vivo images. Magnitude images and R2*-maps acquired with a 3D multi-echo gradient echo sequence and 0.58 mm isotropic resolution were used to create digital models of the cardiac anatomy. Biopsy guides were 3D-printed to steer the extraction of myocardial samples. In total, 61 tissue samples were extracted with an average offset of the tissue sample location from the target location of 0.59 ± 0.36 mm. This offset was not dependent on the distance of the target point to the epicardial surface. Myocardial tissue could be extracted from all samples. The presented method enables extraction of myocardial tissue samples that are selected by ex vivo MRI with submillimeter precision.


Asunto(s)
Corazón , Miocardio , Animales , Porcinos , Biopsia , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética , Impresión Tridimensional
7.
Strahlenther Onkol ; 200(1): 1-18, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38163834

RESUMEN

Accurate Magnetic Resonance Imaging (MRI) simulation is fundamental for high-precision stereotactic radiosurgery and fractionated stereotactic radiotherapy, collectively referred to as stereotactic radiotherapy (SRT), to deliver doses of high biological effectiveness to well-defined cranial targets. Multiple MRI hardware related factors as well as scanner configuration and sequence protocol parameters can affect the imaging accuracy and need to be optimized for the special purpose of radiotherapy treatment planning. MRI simulation for SRT is possible for different organizational environments including patient referral for imaging as well as dedicated MRI simulation in the radiotherapy department but require radiotherapy-optimized MRI protocols and defined quality standards to ensure geometrically accurate images that form an impeccable foundation for treatment planning. For this guideline, an interdisciplinary panel including experts from the working group for radiosurgery and stereotactic radiotherapy of the German Society for Radiation Oncology (DEGRO), the working group for physics and technology in stereotactic radiotherapy of the German Society for Medical Physics (DGMP), the German Society of Neurosurgery (DGNC), the German Society of Neuroradiology (DGNR) and the German Chapter of the International Society for Magnetic Resonance in Medicine (DS-ISMRM) have defined minimum MRI quality requirements as well as advanced MRI simulation options for cranial SRT.


Asunto(s)
Oncología por Radiación , Radiocirugia , Humanos , Radiocirugia/métodos , Imagen por Resonancia Magnética , Dosificación Radioterapéutica , Imagenología Tridimensional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...