Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
J Proteome Res ; 23(2): 644-652, 2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38153093

RESUMEN

Identification of K-Ras and B-Raf mutations in colorectal cancer (CRC) is essential to predict patients' response to anti-EGFR therapy and formulate appropriate therapeutic strategies to improve prognosis and survival. Here, we combined parallel reaction monitoring (PRM) with high-field asymmetric waveform ion mobility (FAIMS) to enhance mass spectrometry sensitivity and improve the identification of low-abundance K-Ras and B-Raf mutations in biological samples without immunoaffinity enrichment. In targeted LC-MS/MS analyses, FAIMS reduced the occurrence of interfering ions and enhanced precursor ion purity, resulting in a 3-fold improvement in the detection limit for K-Ras and B-Raf mutated peptides. In addition, the ion mobility separation of isomeric peptides using FAIMS facilitated the unambiguous identification of K-Ras G12D and G13D peptides. The application of targeted LC-MS/MS analyses using FAIMS is demonstrated for the detection and quantitation of B-Raf V600E, K-Ras G12D, G13D, and G12V in CRC cell lines and primary specimens.


Asunto(s)
Neoplasias Colorrectales , Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida , Péptidos/química , Proteínas Proto-Oncogénicas B-raf/genética , Mutación , Neoplasias Colorrectales/genética , Iones/química
2.
J Proteome Res ; 22(11): 3418-3426, 2023 11 03.
Artículo en Inglés | MEDLINE | ID: mdl-37774690

RESUMEN

Blood serum and plasma are arguably the most commonly analyzed clinical samples, with dozens of proteins serving as validated biomarkers for various human diseases. Top-down proteomics may provide additional insights into disease etiopathogenesis since this approach focuses on protein forms, or proteoforms, originally circulating in blood, potentially providing access to information about relevant post-translational modifications, truncations, single amino acid substitutions, and many other sources of protein variation. However, the vast majority of proteomic studies on serum and plasma are carried out using peptide-centric, bottom-up approaches that cannot recapitulate the original proteoform content of samples. Clinical laboratories have been slow to adopt top-down analysis, also due to higher sample handling requirements. In this study, we describe a straightforward protocol for intact proteoform sample preparation based on the depletion of albumin and immunoglobulins, followed by simplified protein fractionation via polyacrylamide gel electrophoresis. After molecular weight-based fractionation, we supplemented the traditional liquid chromatography-tandem mass spectrometry (LC-MS2) data acquisition with high-field asymmetric waveform ion mobility spectrometry (FAIMS) to further simplify serum proteoform mixtures. This LC-FAIMS-MS2 method led to the identification of over 1000 serum proteoforms < 30 kDa, outperforming traditional LC-MS2 data acquisition and more than doubling the number of proteoforms identified in previous studies.


Asunto(s)
Espectrometría de Movilidad Iónica , Suero , Humanos , Espectrometría de Movilidad Iónica/métodos , Suero/química , Proteómica/métodos , Proteínas/análisis , Espectrometría de Masas/métodos
3.
Anal Chem ; 95(23): 9090-9096, 2023 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-37252723

RESUMEN

The high-throughput quantification of intact proteoforms using a label-free approach is typically performed on proteins in the 0-30 kDa mass range extracted from whole cell or tissue lysates. Unfortunately, even when high-resolution separation of proteoforms is achieved by either high-performance liquid chromatography or capillary electrophoresis, the number of proteoforms that can be identified and quantified is inevitably limited by the inherent sample complexity. Here, we benchmark label-free quantification of proteoforms of Escherichia coli by applying gas-phase fractionation (GPF) via field asymmetric ion mobility spectrometry (FAIMS). Recent advances in Orbitrap instrumentation have enabled the acquisition of high-quality intact and fragmentation mass spectra without the need for averaging time-domain transients prior to Fourier transform. The resulting speed improvements allowed for the application of multiple FAIMS compensation voltages in the same liquid chromatography-tandem mass spectrometry experiment without increasing the overall data acquisition cycle. As a result, the application of FAIMS to label-free quantification based on intact mass spectra substantially increases the number of both identified and quantified proteoforms without penalizing quantification accuracy in comparison to traditional label-free experiments that do not adopt GPF.


Asunto(s)
Espectrometría de Movilidad Iónica , Espectrometría de Masas en Tándem , Espectrometría de Masas en Tándem/métodos , Proteómica/métodos , Proteínas/análisis , Cromatografía Liquida , Escherichia coli/química
4.
Anal Chem ; 94(35): 12086-12094, 2022 09 06.
Artículo en Inglés | MEDLINE | ID: mdl-35995421

RESUMEN

The sensitivity and depth of proteomic analyses are limited by isobaric ions and interferences that preclude the identification of low abundance peptides. Extensive sample fractionation is often required to extend proteome coverage when sample amount is not a limitation. Ion mobility devices provide a viable alternate approach to resolve confounding ions and improve peak capacity and mass spectrometry (MS) sensitivity. Here, we report the integration of differential ion mobility with segmented ion fractionation (SIFT) to enhance the comprehensiveness of proteomic analyses. The combination of differential ion mobility and SIFT, where narrow windows of ∼m/z 100 are acquired in turn, is found particularly advantageous in the analysis of protein digests and typically provided more than 60% gain in identification compared to conventional single-shot LC-MS/MS. The application of this approach is further demonstrated for the analysis of tryptic digests from different colorectal cancer cell lines where the enhanced sensitivity enabled the identification of single amino acid variants that were correlated with the corresponding transcriptomic data sets.


Asunto(s)
Neoplasias del Colon , Proteogenómica , Cromatografía Liquida/métodos , Neoplasias del Colon/genética , Humanos , Iones , Proteoma , Proteómica/métodos , Espectrometría de Masas en Tándem/métodos
5.
Drug Test Anal ; 12(11-12): 1658-1665, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32776416

RESUMEN

In this proof-of-concept study, paper spray mass spectrometry was investigated as a high-throughput and fully automated technique for the initial testing of particularly polar compounds that are prohibited in sports. The technique allows the ionization of analytes from complex sample matrices such as blood and urine when spotted onto a paper strip. By minimizing sample preparation and omitting chromatographic separation, paper spray mass spectrometry benefits from considerable cost- and time-savings compared with conventional high performance liquid chromatography/tandem mass spectrometry, especially in cases where conventional reversed-phase liquid chromatography offers limited applicability. All but one of the investigated model compounds fulfilled the World Anti-Doping Agency's (WADA's) requirements regarding the applicable minimum required performance limits for initial testing procedures. In addition, the combination of paper spray mass spectrometry and ion mobility separation results in enhanced selectivity and sensitivity and is a particularly valuable analytical configuration.


Asunto(s)
Doping en los Deportes/prevención & control , Preparaciones Farmacéuticas/análisis , Preparaciones Farmacéuticas/química , Detección de Abuso de Sustancias/métodos , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Líquida de Alta Presión/normas , Doping en los Deportes/métodos , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Espectrometría de Masas/métodos , Espectrometría de Masas/normas , Proyectos Piloto , Prueba de Estudio Conceptual , Detección de Abuso de Sustancias/normas , Espectrometría de Masas en Tándem/normas
6.
Chem Sci ; 7(1): 39-55, 2016 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-28757996

RESUMEN

There has been a burst in the number and variety of available ionization techniques to use mass spectrometry to monitor chemical reactions in and on liquids. Chemists have gained the capability to access chemistry at unprecedented timescales, and monitor reactions and detect intermediates under almost any set of conditions. Herein, recently developed ionization techniques that facilitate mechanistic studies of chemical processes are reviewed. This is followed by a discussion of our perspective on the judicious application of these and similar techniques in order to study reaction mechanisms.

7.
Chem Sci ; 6(3): 1917-1922, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25729560

RESUMEN

An asymmetric palladium-catalyzed conjugate addition reaction of arylboronic acids to enone substrates was investigated mechanistically. Desorption electrospray ionization coupled to mass spectrometry was used to identify intermediates of the catalytic cycle and delineate differences in substrate reactivity. Our findings provide evidence for the catalytic cycle proceeding through formation of an arylpalladium(II) cation, subsequent formation of an arylpalladium-enone complex, and, ultimately, formation of the new C-C bond. Reaction monitoring in both positive and negative ion modes revealed that 4-iodophenylboronic acid formed a relatively stable trimeric species under the reaction conditions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA