Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sports Biomech ; 20(7): 831-843, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31070113

RESUMEN

Amplified by the development of new technologies, the interest in personal performance has been growing over the last years. Acceleration has proved to be an easy variable to collect, and was addressed in several works. However, few of them evaluate the effect of running speed on relevant indicators. The influence of the sensors location on the measurement is rarely studied as well. This study is dedicated to investigating the effect of running speed on acceleration measured at three different positions on 18 volunteers. All participants were equipped with three inertial measurement units: on the dorsal surface of the right foot (Fo), at the centre of gravity of the tibia (Ti), at the L4-L5 lumbar (Lu). The test was performed on a treadmill at nine randomised speeds between 8 and 18 km/h. Ten accelerometric variables were calculated. Linear regressions were used to calculate speed from the indicators calculated on (Lu), (Ti), (Fo). Indicators associated to signal energy were highly correlated with speed (r2>0.90). Median frequency appears to be affected by the frequency resolution. Finally, the measurement points closest to the impact zone result in the most correlated indicators.


Asunto(s)
Acelerometría/métodos , Sistemas Microelectromecánicos/métodos , Carrera/fisiología , Dispositivos Electrónicos Vestibles , Aceleración , Adulto , Fenómenos Biomecánicos , Femenino , Pie , Humanos , Región Lumbosacra , Masculino , Tibia
2.
Sports Biomech ; 20(3): 330-343, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30681024

RESUMEN

Defining relationships between running mechanisms and fatigue can be a major asset for optimising training. This article proposes a biomechanical model of time to exhaustion according to indicators derived from accelerometry data collected from the body. Ten volunteers were recruited for this study. The participants were equipped with 3 accelerometers: on the right foot, at the tibia and at the L4-L5 lumbar spine. A running test was performed on a treadmill at 13.5 km/h until exhaustion. Thirty-one variables were deployed during the test. Multiple linear regressions were calculated to explain the time to exhaustion from the indicators calculated on the lumbar, tibia and foot individually and simultaneously. Time to exhaustion was predicted for simultaneous measurement points with r 2 = 0.792 and 21 indicators; for the lumbar with r 2 = 0.568 and 11 indicators; for the tibia with r 2 = 558 and 11 indicators; and for the foot with r 2 = 0.626 and 12 indicators. This study allows the accurate modelling of the time to exhaustion during a running-based test using indicators from accelerometer measurements. The individual models highlight that the location of the measurement point is important and that each location provides different information. Future studies should focus on homogeneous populations to improve predictions and errors.


Asunto(s)
Acelerometría/instrumentación , Resistencia Física/fisiología , Carrera/fisiología , Dispositivos Electrónicos Vestibles , Adulto , Fenómenos Biomecánicos/fisiología , Femenino , Pie , Humanos , Modelos Lineales , Región Lumbosacra , Masculino , Modelos Biológicos , Reproducibilidad de los Resultados , Tibia , Factores de Tiempo
3.
Sensors (Basel) ; 17(9)2017 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-28841142

RESUMEN

The musculo-skeletal response of athletes to various activities during training exercises has become a critical issue in order to optimize their performance and minimize injuries. However, dynamic and kinematic measures of an athlete's activity are generally limited by constraints in data collection and technology. Thus, the choice of reliable and accurate sensors is crucial for gathering data in indoor and outdoor conditions. The aim of this study is to validate the use of the accelerometer of a high sampling rate ( 1344 Hz ) Inertial Measurement Unit (IMU) in the frame of running activities. To this end, two validation protocols are imposed: a classical one on a shaker, followed by another one during running, the IMU being attached to a test subject. For each protocol, the response of the IMU Accelerometer (IMUA) is compared to a calibrated industrial accelerometer, considered as the gold standard for dynamic and kinematic data collection. The repeatability, impact of signal frequency and amplitude (on shaker) as well as the influence of speed (while running) are investigated. Results reveal that the IMUA exhibits good repeatability. Coefficient of Variation CV is 1 % 8.58 ± 0.06 m / s 2 on the shaker and 3 % 26.65 ± 0.69 m / s 2 while running. However, the shaker test shows that the IMUA is affected by the signal frequency (error exceeds 10 % beyond 80 Hz ), an observation confirmed by the running test. Nevertheless, the IMUA provides a reliable measure in the range 0-100 Hz, i.e., the most relevant part in the energy spectrum over the range 0-150 Hz during running. In our view, these findings emphasize the validity of IMUs for the measurement of acceleration during running.


Asunto(s)
Carrera , Aceleración , Atletas , Fenómenos Biomecánicos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...