RESUMEN
AIMS/HYPOTHESIS: We assessed the impact of initiating intermittently scanned continuous glucose monitoring (isCGM) compared with capillary blood glucose monitoring (BGM) on HbA1c levels and hospitalisations for diabetes-related complications in adults with insulin-treated type 2 diabetes in Sweden. METHODS: This retrospective comparative cohort study included adults with type 2 diabetes who had a National Diabetes Register initiation date for isCGM after 1 June 2017. Prescribed Drug Register records identified subgroups treated with multiple daily insulin injections (T2D-MDI) or basal insulin (T2D-B), with or without other glucose-lowering drugs. The National Patient Register provided data on hospitalisation rates. RESULTS: We identified 2876 adults in the T2D-MDI group and 2292 in the T2D-B group with an isCGM index date after 1 June 2017, matched with 33,584 and 43,424 BGM control participants, respectively. The baseline-adjusted difference in the change in mean HbA1c for isCGM users vs BGM control participants in the T2D-MDI cohort was -3.7 mmol/mol (-0.34%) at 6 months, and this was maintained at 24 months. The baseline-adjusted difference in the change in HbA1c for isCGM users vs BGM control participants in the T2D-B cohort was -3.5 mmol/mol (-0.32%) at 6 months, and this was also maintained at 24 months. Compared with BGM control participants, isCGM users in the T2D-MDI cohort had a significantly lower RR of admission for severe hypoglycaemia (0.51; 95% CI 0.27, 0.95), stroke (0.54; 95% CI 0.39, 0.73), acute non-fatal myocardial infarction (0.75; 95% CI 0.57, 0.99) or hospitalisation for any reason (0.84; 95% CI 0.77, 0.90). isCGM users in the T2D-B cohort had a lower RR of admission for heart failure (0.63; 95% CI 0.46, 0.87) or hospitalisation for any reason (0.76; 95% CI 0.69, 0.84). CONCLUSIONS/INTERPRETATION: This study shows that Swedish adults with type 2 diabetes on insulin who are using isCGM have a significantly reduced HbA1c and fewer hospital admissions for diabetes-related complications compared with BGM control participants.
RESUMEN
OBJECTIVE: We assessed the impact of intermittently scanned continuous glucose monitoring (isCGM) compared with blood glucose monitoring (BGM) on rates of hospitalization for metabolic and vascular complications of diabetes and on HbA1c levels for adults with type 1 diabetes. RESEARCH DESIGN AND METHODS: This retrospective study using data from the Swedish National Diabetes Register and the Swedish National Patient Register comprised adults with type 1 diabetes and an isCGM initiation date after 1 June 2017 and matched control individuals using BGM. Hospital admission rates were calculated per 100 person-years of follow-up. RESULTS: We identified 11,822 adults with type 1 diabetes and an isCGM index date after 1 June 2017 and HbA1c baseline values 3-8 months prior to the index date. Compared with 3,007 BGM users, isCGM users had a significantly lower relative risk of hospitalization for hypoglycemia (0.32; 95% CI 0.14, 0.74), diabetic ketoacidosis (0.55; 0.35, 0.87), stroke (0.48; 0.37, 0.64), acute myocardial infarction (0.64; 0.46, 0.91), atrial fibrillation (0.59; 0.38, 0.94), heart failure (0.25; 0.16, 0.39), peripheral vascular disease (0.21; 0.07, 0.62), kidney disease (0.48; 0.35, 0.66), or hospitalization for any reason (0.32; 0.29, 0.35). Compared with BGM users, change in mean HbA1c for isCGM users was -0.30% (-3.3 mmol/mol) at 6 months and -0.24% (-2.6 mmol/mol) at 24 months (both P < 0.001). CONCLUSIONS: This study shows that adults with type 1 diabetes in Sweden who initiate isCGM have significantly reduced hospitalization rates for acute diabetes events, kidney disease, and cardiovascular complications, along with improved glucose control, compared with BGM users.
RESUMEN
AIMS/HYPOTHESIS: Previous studies have shown that individuals with similar mean glucose levels (MG) or percentage of time in range (TIR) may have different HbA1c values. The aim of this study was to further elucidate how MG and TIR are associated with HbA1c. METHODS: Data from the randomised clinical GOLD trial (n=144) and the follow-up SILVER trial (n=98) of adults with type 1 diabetes followed for 2.5 years were analysed. A total of 596 paired HbA1c/continuous glucose monitoring measurements were included. Linear mixed-effects models were used to account for intra-individual correlations in repeated-measures data. RESULTS: In the GOLD trial, the mean age of the participants (± SD) was 44±13 years, 63 (44%) were female, and the mean HbA1c (± SD) was 72±9.8 mmol/mol (8.7±0.9%). When correlating MG with HbA1c, MG explained 63% of the variation in HbA1c (r=0.79, p<0.001). The variation in HbA1c explained by MG increased to 88% (r=0.94, p value for improvement of fit <0.001) when accounting for person-to-person variation in the MG-HbA1c relationship. Time below range (TBR; <3.9 mmol/l), time above range (TAR) level 2 (>13.9 mmol/l) and glycaemic variability had little or no effect on the association. For a given MG and TIR, the HbA1c of 10% of individuals deviated by >8 mmol/mol (0.8%) from their estimated HbA1c based on the overall association between MG and TIR with HbA1c. TBR and TAR level 2 significantly influenced the association between TIR and HbA1c. At a given TIR, each 1% increase in TBR was related to a 0.6 mmol/mol lower HbA1c (95% CI 0.4, 0.9; p<0.001), and each 2% increase in TAR level 2 was related to a 0.4 mmol/mol higher HbA1c (95% CI 0.1, 0.6; p=0.003). However, neither TIR, TBR nor TAR level 2 were significantly associated with HbA1c when accounting for MG. CONCLUSIONS/INTERPRETATION: Inter-individual variations exist between MG and HbA1c, as well as between TIR and HbA1c, with clinically important deviations in relatively large groups of individuals with type 1 diabetes. These results may provide important information to both healthcare providers and individuals with diabetes in terms of prognosis and when making diabetes management decisions.
Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hemoglobina Glucada , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Hemoglobina Glucada/metabolismo , Femenino , Glucemia/metabolismo , Adulto , Masculino , Persona de Mediana Edad , Hipoglucemiantes/uso terapéutico , Automonitorización de la Glucosa SanguíneaRESUMEN
INTRODUCTION: This study utilized continuous glucose monitoring data to analyze the effects of switching to treatment with fast-acting insulin aspart (faster aspart) in adults with type 1 diabetes (T1D) in clinical practice. METHODS: A noninterventional database review was conducted in Sweden among adults with T1D using multiple daily injection (MDI) regimens who had switched to treatment with faster aspart as part of basal-bolus treatment. Glycemic data were retrospectively collected during the 26 weeks before switching (baseline) and up to 32 weeks after switching (follow-up) to assess changes in time in glycemic range (TIR; 70-180 mg/dL), mean sensor glucose, glycated hemoglobin (HbA1c) levels, coefficient of variation, time in hyperglycemia (level 1, > 180 to ≤ 250 mg/dL; level 2, > 250 mg/dL), and time in hypoglycemia (level 1, ≥ 54 to < 70 mg/dL; level 2, < 54 mg/dL) (ClinicalTrials.gov Identifier NCT03895515). RESULTS: Overall, 178 participants were included in the study cohort. The analysis population included 82 individuals (mean age 48.5 years) with adequate glucose sensor data. From baseline to follow-up, statistically significant improvements were reported for TIR (mean increase 3.3%-points [approximately 48 min/day]; p = 0.006) with clinically relevant improvement (≥ 5%) in 43% of participants. Statistically significant improvements from baseline were observed for mean sensor glucose levels, HbA1c levels, and time in hyperglycemia (levels 1 and 2), with no statistically significant changes in time spent in hypoglycemia. CONCLUSIONS: Switching to faster aspart was associated with improvements in glycemic control without increasing hypoglycemia in adults with T1D using MDI in this real-world setting.
RESUMEN
BACKGROUND: The GOLD trial demonstrated that continuous glucose monitoring (CGM) in people with type 1 diabetes (T1D) managed with multiple daily insulin injections (MDI) improved not only glucose control but also overall well-being and treatment satisfaction. This analysis investigated which factors contributed to improved well-being and treatment satisfaction with CGM. METHODS: The GOLD trial was a randomized crossover trial comparing CGM versus self-monitored blood glucose (SMBG) over 16 months. Endpoints included well-being measured by the World Health Organization-Five Well-Being Index (WHO-5) and treatment satisfaction by the Diabetes Treatment Satisfaction Questionnaire (DTSQ) as well as glucose metrics. Multivariable R2-decomposition was used to understand which variables contributed most to treatment satisfaction. RESULTS: A total of 139 participants were included. Multivariable analyses revealed that increased convenience and flexibility contributed to 60% (95% confidence interval [CI] = 50%-69%) of the improvement in treatment satisfaction (Diabetes Treatment Satisfaction Questionnaire change version [DTSQc]) observed with CGM, whereas perceived effects on hypoglycemia and hyperglycemia only contributed to 6% (95% CI = 2%-11%) of improvements. Significant improvements in well-being (WHO-5) by CGM were observed for the following: feeling cheerful (P = .025), calm and relaxed (P = .024), being active (P = .046), and waking up fresh and rested (P = .044). HbA1c reductions and increased time in range (TIR) were associated with increased treatment satisfaction, whereas glycemic variability was not. HbA1c reduction showed also an association with increased well-being and increased TIR with less diabetes-related distress. CONCLUSIONS: While CGM improves glucose control in people with T1D on MDI, increased convenience and flexibility through CGM is of even greater importance for treatment satisfaction and patient well-being. These CGM-mediated effects should be taken into account when considering CGM initiation.
Asunto(s)
Glucemia , Péptido C , Diabetes Mellitus Tipo 1 , Glucemia/análisis , Péptido C/metabolismo , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 1/terapia , Progresión de la Enfermedad , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéuticoRESUMEN
BACKGROUND: People with type 1 diabetes generally view it easier to exercise when having continuous information of the glucose levels. We evaluated whether patients with type 1 diabetes managed with multiple daily insulin injections (MDI) exercised more after initiating continuous glucose monitoring (CGM) and whether the improved glycemic control and well-being associated with CGM translates into improved blood lipids and markers of inflammation. METHOD: The GOLD trial was a randomized cross-over trial over 16 months where patients used either CGM or capillary self-monitoring of blood glucose (SMBG) over six months, with a four-month wash-out period between the two treatment periods. We compared grade of physical activity, blood lipids, apolipoproteins, and high-sensitivity C-reactive protein (hsCRP) levels during CGM and SMBG. RESULTS: There were 116 patients with information of physical activity estimated by the International Physical Activity Questionnaire (IPAQ) during both CGM and SMBG. No changes were found during CGM or SMBG, IPAQ scores 3305 versus 3878 (P = .16). In 136 participants with information of blood lipid levels with no change in lipid-lowering medication during the two treatment periods, HbA1c differed by 4.2 mmol/mol (NGSP 0.39%) between SMBG and CGM treatment (P < .001). No significant changes existed in low-density lipoprotein, high-density lipoprotein, triglycerides, total cholesterol, apolipoprotein A1, apolipoprotein B1, or hsCRP, during CGM and SMBG. CONCLUSION: Although many patients experience it easier to perform physical activity when monitoring glucose levels with CGM, it does not influence the amount of physical activity in persons with type 1 diabetes. Blood lipids, apolipoprotein, and hsCRP levels were similar during CGM and SMBG.
RESUMEN
AIMS/HYPOTHESIS: The aim of this work was to evaluate changes in glycaemic control (HbA1c) and rates of severe hypoglycaemia over a 2 year period after initiation of flash glucose monitoring (FM) in type 1 diabetes. METHODS: Using data from the Swedish National Diabetes Registry, 14,372 adults with type 1 diabetes with a new registration of FM during 2016-2017 and with continued FM for two consecutive years thereafter, and 7691 control individuals using conventional self-monitoring of blood glucose (SMBG) during the same observation period, were included in a cohort study. Propensity sores and inverse probability of treatment weighting (IPTW) were used to balance FM users with SMBG users. Changes in HbA1c and events of severe hypoglycaemia were compared. RESULTS: After the start of FM, the difference in IPTW change in HbA1c was slightly greater in FM users compared with the control group during the follow-up period, with an estimated mean absolute difference of -1.2 mmol/mol (-0.11%) (95% CI -1.64 [-0.15], -0.75 [-0.07]; p < 0.0001) after 15-24 months. The change in HbA1c was greatest in those with baseline HbA1c ≥70 mmol/mol (8.5%), with the estimated mean absolute difference being -2.5 mmol/mol (-0.23%) (95% CI -3.84 [-0.35], -1.18 [-0.11]; p = 0.0002) 15-24 months post index. The change was also significant in the subgroups with initial HbA1c ≤52 mmol/mol (6.9%) and 53-69 mmol/mol (7.0-8.5%). Risk of severe hypoglycaemic episodes was reduced by 21% for FM users compared with control individuals using SMBG (OR 0.79 [95% CI 0.69, 0.91]; p = 0.0014)]. CONCLUSIONS/INTERPRETATION: In this large cohort, the use of FM was associated with a small and sustained improvement in HbA1c, most evident in those with higher baseline HbA1c levels. In addition, FM users experienced lower rates of severe hypoglycaemic events compared with control individuals using SMBG for self-management of glucose control.
Asunto(s)
Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Control Glucémico/métodos , Adulto , Anciano , Automonitorización de la Glucosa Sanguínea/métodos , Estudios de Casos y Controles , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/sangre , Hipoglucemia/diagnóstico , Inyecciones , Insulina/administración & dosificación , Sistemas de Infusión de Insulina , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , SueciaRESUMEN
AIM: To identify responders to continuous glucose monitoring (CGM) in relation to reductions in HbA1c and percentage of time spent in hypoglycaemia after initiation of CGM for individuals with type 1 diabetes treated with multiple daily insulin injections. MATERIALS AND METHODS: We analysed data from 142 participants in the GOLD randomized clinical trial. We evaluated how many lowered their HbA1c by more than 0.4% (>4.7 mmol/mol) or decreased the time spent in hypoglycaemia over 24 hours by more than 20 or 30 minutes, and which baseline variables were associated with those improvements. RESULTS: Lower reduction of HbA1c was associated with greater reduction of hypoglycaemia (r = -0.52; P < .0001). During CGM, 47% of participants lowered their HbA1c values by more than 0.4% (>4.7 mmol/mol) than with self-measurement of blood glucose, and 47% decreased the time spent in hypoglycaemia by more than 20 minutes over 24 hours. Overall, 78% either reduced their HbA1c by more than 0.4% (>4.7 mmol/mol) or the time spent in hypoglycaemia by more than 20 minutes over 24 hours, but only 14% improved both. Higher HbA1c, a lower percentage of time at less than 3.0 or 3.9 mmol/L, a lower coefficient of variation (CV) and a higher percentage of time above 13.9 mmol/L (P = .016) were associated with greater HbA1c reduction during CGM. The variables associated with a greater reduction of time in hypoglycaemia were female sex, greater time with glucose levels at less than 3.0 mmol/L, higher CV, and higher hypoglycaemia confidence as evaluated by a hypoglycaemic confidence questionnaire. CONCLUSION: The majority of people with type 1 diabetes managed by multiple daily insulin injections benefit from CGM; some experienced reduced HbA1c while others reduced the time spent in hypoglycaemia. These factors need to be considered by healthcare professionals and decision-makers for reimbursement and diabetes guidelines.
Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemiantes , Insulina , MasculinoRESUMEN
OBJECTIVE: Continuous glucose monitoring (CGM) reduces HbA1c and time spent in hypoglycemia in people with type 1 diabetes (T1D) treated with multiple daily insulin injections (MDI) when evaluated over shorter time periods. It is unclear to what extent CGM improves and helps to maintain glucose control, treatment satisfaction, diabetes distress, hypoglycemic concerns, and overall well-being over longer periods of time. RESEARCH DESIGN AND METHODS: The GOLD trial was a randomized crossover trial performed over 16 months of CGM treatment in people with T1D treated with MDI. People completing the trial (n = 141) were invited to participate in the current SILVER extension study in which 107 patients continued CGM treatment over 1 year along with the support of a diabetes nurse every 3 months. RESULTS: The primary end point of the change in HbA1c over 1.0-1.5 years of CGM use compared with previous self-monitoring of blood glucose during GOLD showed a decrease in HbA1c of 0.35% (95% CI 0.19-0.50, P < 0.001). Time spent in hypoglycemia <3.0 mmol/L (54 mg/dL) and <4.0 mmol/L (72 mg/dL) decreased from 2.1% to 0.6% (P < 0.001) and from 5.4% to 2.9% (P < 0.001), respectively. Overall well-being (World Health Organization 5-item well-being index, P = 0.009), treatment satisfaction (Diabetes Treatment Satisfaction Questionnaire, P < 0.001), and hypoglycemic confidence (P < 0.001) increased, while hypoglycemic fear (Hypoglycemia Fear Survey-Worry, P = 0.016) decreased and diabetes distress tended to decrease (Problem Areas in Diabetes Scale, P = 0.06). From randomization and screening in GOLD, HbA1c was lowered by 0.45% (P < 0.001) and 0.68% (P < 0.001) after 2.3 and 2.5 years, respectively. CONCLUSIONS: The SILVER study supports beneficial long-term effects from CGM on HbA1c, hypoglycemia, treatment satisfaction, well-being, and hypoglycemic confidence in people with T1D managed with MDI.
Asunto(s)
Diabetes Mellitus Tipo 1 , Glucemia , Automonitorización de la Glucosa Sanguínea , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes/uso terapéutico , Insulina , PlataAsunto(s)
Automonitorización de la Glucosa Sanguínea , Hipoglucemia , Glucemia , Diabetes Mellitus Tipo 1 , Glucosa , Humanos , Hipoglucemiantes , InsulinaRESUMEN
BACKGROUND: To evaluate the effects of continuous glucose monitoring (CGM) on nocturnal and daytime hypoglycemia in persons with type 1 diabetes treated with multiple daily insulin injections (MDI); we also evaluated factors related to differences in hypoglycemia confidence in this population. METHODS: Evaluations were performed from the GOLD randomized trial, an open-label multicenter crossover randomized clinical trial (n = 161) over 69 weeks comparing CGM to self-measurement of blood glucose (SMBG) in persons with type 1 diabetes treated with MDI. Masked CGM and the hypoglycemia confidence questionnaire were used for evaluations. RESULTS: Time with nocturnal hypoglycemia, glucose levels <70 mg/dL was reduced by 48% (10.2 vs. 19.6 min each night, P < 0.001) and glucose levels <54 mg/dL by 65%. (3.1 vs. 8.9 min, P < 0.001). For the corresponding glucose cutoffs, daytime hypoglycemia was reduced by 40% (29 vs. 49 min, P < 0.001) and 54% (8 vs. 18 min., P < 0.001), respectively. Compared with SMBG, CGM use improved hypoglycemia-related confidence in social situations (P = 0.016) and confidence in more broadly avoiding serious problems due to hypoglycemia (P = 0.0020). Persons also reported greater confidence in detecting and responding to decreasing blood glucose levels (thereby avoiding hypoglycemia) during CGM use (P = 0.0033) and indicated greater conviction that they could more freely live their lives despite the risk of hypoglycemia (P = 0.022). CONCLUSION: CGM reduced time in both nocturnal and daytime hypoglycemia in persons with type 1 diabetes treated with MDI and improved hypoglycemia-related confidence, especially in social situations, thus contributing to greater well-being and quality of life. TRIAL REGISTRATION: ClinicalTrials.gov , number NCT02092051.
Asunto(s)
Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Hipoglucemia/sangre , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Adulto , Automonitorización de la Glucosa Sanguínea , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Masculino , Persona de Mediana Edad , Calidad de VidaRESUMEN
AIMS/HYPOTHESIS: Evidence for the effectiveness of interstitial glucose monitoring in individuals with type 1 diabetes using multiple daily injection (MDI) therapy is limited. In this pre-specified subgroup analysis of the Novel Glucose-Sensing Technology and Hypoglycemia in Type 1 Diabetes: a Multicentre, Non-masked, Randomised Controlled Trial' (IMPACT), we assessed the impact of flash glucose technology on hypoglycaemia compared with capillary glucose monitoring. METHODS: This multicentre, prospective, non-masked, RCT enrolled adults from 23 European diabetes centres. Individuals were eligible to participate if they had well-controlled type 1 diabetes (diagnosed for ≥5 years), HbA1c ≤ 58 mmol/mol [7.5%], were using MDI therapy and on their current insulin regimen for ≥3 months, reported self-monitoring of blood glucose on a regular basis (equivalent to ≥3 times/day) for ≥2 months and were deemed technically capable of using flash glucose technology. Individuals were excluded if they were diagnosed with hypoglycaemia unawareness, had diabetic ketoacidosis or myocardial infarction in the preceding 6 months, had a known allergy to medical-grade adhesives, used continuous glucose monitoring (CGM) within the previous 4 months or were currently using CGM or sensor-augmented pump therapy, were pregnant or planning pregnancy or were receiving steroid therapy for any disorders. Following 2 weeks of blinded (to participants and investigator) sensor wear by all participants, participants with sensor data for more than 50% of the blinded wear period (or ≥650 individual sensor results) were randomly assigned, in a 1:1 ratio by a central interactive web response system (IWRS) using the biased-coin minimisation method, to flash sensor-based glucose monitoring (intervention group) or self-monitoring of capillary blood glucose (control group). The control group had two further 14 day blinded sensor-wear periods at the 3 and 6 month time points. Participants, investigators and staff were not masked to group allocation. The primary outcome was the change in time in hypoglycaemia (<3.9 mmol/l) between baseline and 6 months in the full analysis set. RESULTS: Between 4 September 2014 and 12 February 2015, 167 participants using MDI were enrolled. After screening and the baseline phase, participants were randomised to intervention (n = 82) and control groups (n = 81). One woman from each group was excluded owing to pregnancy; the full analysis set included 161 randomised participants. At 6 months, mean time in hypoglycaemia was reduced by 46.0%, from 3.44 h/day to 1.86 h/day in the intervention group (baseline adjusted mean change, -1.65 h/day), and from 3.73 h/day to 3.66 h/day in the control group (baseline adjusted mean change, 0.00 h/day), with a between-group difference of -1.65 (95% CI -2.21, -1.09; p < 0.0001). For participants in the intervention group, the mean ± SD daily sensor scanning frequency was 14.7 ± 10.7 (median 12.3) and the mean number of self-monitored blood glucose tests performed per day reduced from 5.5 ± 2.0 (median 5.4) at baseline to 0.5 ± 1.0 (median 0.1). The baseline frequency of self-monitored blood glucose tests by control participants was maintained (from 5.6 ± 1.9 [median 5.2] to 5.5 ± 2.6 [median 5.1] per day). Treatment satisfaction and perception of hypo/hyperglycaemia were improved compared with control. No device-related hypoglycaemia or safety-related issues were reported. Nine serious adverse events were reported for eight participants (four in each group), none related to the device. Eight adverse events for six of the participants in the intervention group were also reported, which were related to sensor insertion/wear; four of these participants withdrew because of the adverse event. CONCLUSIONS/INTERPRETATION: Use of flash glucose technology in type 1 diabetes controlled with MDI therapy significantly reduced time in hypoglycaemia without deterioration of HbA1c, and improved treatment satisfaction. TRIAL REGISTRATION: ClinicalTrials.gov NCT02232698 FUNDING: Abbott Diabetes Care, Witney, UK.