1.
Bioengineering (Basel) ; 11(6)2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38927841

RESUMEN

Background/Objectives: We defined the value of a machine learning algorithm to distinguish between the EEG response to no light or any light stimulations, and between light stimulations with different brightnesses in awake volunteers with closed eyelids. This new method utilizing EEG analysis is visionary in the understanding of visual signal processing and will facilitate the deepening of our knowledge concerning anesthetic research. Methods: X-gradient boosting models were used to classify the cortical response to visual stimulation (no light vs. light stimulations and two lights with different brightnesses). For each of the two classifications, three scenarios were tested: training and prediction in all participants (all), training and prediction in one participant (individual), and training across all but one participant with prediction performed in the participant left out (one out). Results: Ninety-four Caucasian adults were included. The machine learning algorithm had a very high predictive value and accuracy in differentiating between no light and any light stimulations (AUCROCall: 0.96; accuracyall: 0.94; AUCROCindividual: 0.96 ± 0.05, accuracyindividual: 0.94 ± 0.05; AUCROConeout: 0.98 ± 0.04; accuracyoneout: 0.96 ± 0.04). The machine learning algorithm was highly predictive and accurate in distinguishing between light stimulations with different brightnesses (AUCROCall: 0.97; accuracyall: 0.91; AUCROCindividual: 0.98 ± 0.04, accuracyindividual: 0.96 ± 0.04; AUCROConeout: 0.96 ± 0.05; accuracyoneout: 0.93 ± 0.06). The predictive value and accuracy of both classification tasks was comparable between males and females. Conclusions: Machine learning algorithms could almost continuously and reliably differentiate between the cortical EEG responses to no light or light stimulations using visual evoked potentials in awake female and male volunteers with eyes closed. Our findings may open new possibilities for the use of visual evoked potentials in the clinical and intraoperative setting.

2.
J Cataract Refract Surg ; 50(8): 805-809, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38529959

RESUMEN

PURPOSE: To use a combination of partial least squares regression and a machine learning approach to predict intraocular lens (IOL) tilt using preoperative biometry data. SETTING: Kepler University Clinic Linz, Linz, Austria. DESIGN: Prospective single-center study. METHODS: Optical coherence tomography, autorefraction, and subjective refraction were performed at baseline and 8 weeks after cataract surgery. In analysis I, only 1 eye per patient was included and a tilt prediction model was generated. In analysis II, a pairwise comparison between right and left eyes was performed. RESULTS: In analysis I, 50 eyes of 50 patients were analyzed. Difference in amount, orientation, and vector from preoperative to postoperative lens tilt was -0.13 degrees, 2.14 degrees, and 1.20 degrees, respectively. A high predictive power (variable importance for projection [VIP]) for postoperative tilt prediction was found for preoperative tilt (VIP = 2.2), pupil decentration (VIP = 1.5), lens thickness (VIP = 1.1), axial eye length (VIP = 0.9), and preoperative lens decentration (VIP = 0.8). These variables were applied to a machine learning algorithm resulting in an out of bag score of 0.92 degrees. In analysis II, 76 eyes of 38 patients were included. The difference of preoperative to postoperative IOL tilt of right and left eyes of the same individual was statistically relevant. CONCLUSIONS: Postoperative IOL tilt showed excellent predictability using preoperative biometry data and a combination of partial least squares regression and a machine learning algorithm. Preoperative lens tilt, pupil decentration, lens thickness, axial eye length, and preoperative lens decentration were found to be the most relevant parameters for this prediction model.

3.
Acta Ophthalmol ; 102(5): e797-e804, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38306110

RESUMEN

PURPOSE: Bleb failure is a common complication after glaucoma filtration surgery. Different bleb classification schemes incorporating filtration bleb vascularization have been proposed, but the reported correlation with intraocular pressure (IOP) has been variable, possibly because of subjective vascularization grading. The purpose of the present study was to evaluate bleb vascularization after Preserflo Microshunt (PM) implantation using anterior segment OCT-angiography (AS-OCTA) as a biomarker for bleb failure. METHODS: Twenty-three eyes of twenty-three patients underwent PM implantation. Up to 12 months after surgery PM scleral passage-centred AS-OCTA measurements (PLEX Elite 9000) for bleb-vessel density (BVD) determination were performed and IOP as well as necessity for surgical revisions (needling and open revision) were documented. After multi-step image analysis (region of interest definition, artefact removal, binarization, BVD calculation), the predictive value of early postoperative BVD for surgical revisions was assessed using logistic regression modelling. RESULTS: Baseline IOP (23.57 ± 7.75 mmHg) decreased significantly to 8.30 ± 2.12, 9.17 ± 2.33 and 11.70 ± 4.40 mmHg after 1, 2 and 4 week(s), and 13.48 ± 5.83, 11.87 ± 4.49, 12.30 ± 6.65, 11.87 ± 3.11 and 13.05 ± 4.12 mmHg after 2, 3, 6, 9 and 12 month(s), respectively (p < 0.001). Nine patients (39%) needed surgical revisions after a median time of 2 months. Bleb vessel densities at 2 and 4 weeks were significantly associated with future surgical revisions upon logistic regression analysis (2 W/4 W likelihood-ratio test p-value: 0.0244/0.0098; 2 W/4 W area under the receiver operating characteristics curve: 0.796/0.909). CONCLUSION: Filtration bleb vessel density can be determined using AS-OCTA in the early postoperative period and is predictive for bleb failure after PM implantation.


Asunto(s)
Presión Intraocular , Reoperación , Tomografía de Coherencia Óptica , Humanos , Femenino , Masculino , Presión Intraocular/fisiología , Anciano , Tomografía de Coherencia Óptica/métodos , Persona de Mediana Edad , Angiografía con Fluoresceína/métodos , Estudios de Seguimiento , Glaucoma/cirugía , Glaucoma/fisiopatología , Glaucoma/diagnóstico , Implantes de Drenaje de Glaucoma/efectos adversos , Cirugía Filtrante/métodos , Estudios Prospectivos , Fondo de Ojo , Conjuntiva/irrigación sanguínea , Conjuntiva/cirugía , Densidad Microvascular
4.
Acta Ophthalmol ; 102(3): e285-e295, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37350286

RESUMEN

PURPOSE: The purpose of this study was to investigate the uncertainty in the formula predicted refractive outcome REFU after cataract surgery resulting from measurement uncertainties in modern optical biometers using literature data for within-subject standard deviation Sw. METHODS: This Monte-Carlo simulation study used a large dataset containing 16 667 preoperative IOLMaster 700 biometric measurements. Based on literature Sw values, REFU was derived for both the Haigis and Castrop formulae using error propagation strategies. Using the Hoya Vivinex lens (IOL) as an example, REFU was calculated both with (WLT) and without (WoLT) consideration of IOL power labelling tolerances. RESULTS: WoLT the median REFU was 0.10/0.12 dpt for the Haigis/Castrop formula, and WLT it was 0.13/0.15 dpt. WoLT REFU increased systematically for short eyes (or high power IOLs), and WLT this effect was even more pronounced because of increased labelling tolerances. WoLT the uncertainty in the measurement of the corneal front surface radius showed the largest contribution to REFU, especially in long eyes (and low power IOLs). WLT the IOL power uncertainty dominated in short eyes (or high power IOLs) and the uncertainty of the corneal front surface in long eyes (or low power IOLs). CONCLUSIONS: Compared with published data on the formula prediction error of refractive outcome after cataract surgery, the uncertainty of biometric measures seems to contribute with ⅓ to ½ to the entire standard deviation. REFU systematically increases with IOL power and decreases with axial length.


Asunto(s)
Catarata , Lentes Intraoculares , Facoemulsificación , Humanos , Agudeza Visual , Implantación de Lentes Intraoculares , Incertidumbre , Refracción Ocular , Biometría/métodos , Estudios Retrospectivos , Óptica y Fotónica
5.
Am J Ophthalmol ; 260: 102-114, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38092314

RESUMEN

PURPOSE: This study aimed to explore the concept of total keratometry (TK) by analyzing extensive international datasets representing diverse ethnic backgrounds. The primary objective was to quantify the disparities between traditional keratometry (K) and TK values in normal eyes and assess their impact on intraocular lens (IOL) power calculations using various formulas. DESIGN: Retrospective multicenter intra-instrument reliability analysis. METHODS: The study involved the analysis of biometry data collected from ten international centers across Europe, the United States, and Asia. Corneal power was expressed as equivalent power and astigmatic vector components for both K and TK values. The study assessed the influence of these differences on IOL power calculations using different formulas. The results were analyzed and plotted using Bland-Altman and double angle plots. RESULTS: The study encompassed a total of 116,982 measurements from 57,862 right eyes and 59,120 left eyes. The analysis revealed a high level of agreement between K and TK values, with 93.98% of eyes exhibiting an absolute difference of 0.25 D or less. Astigmatism vector differences exceeding 0.25 D and 0.50 D were observed in 39.43% and 1.08% of eyes, respectively. CONCLUSIONS: This large-scale study underscores the similarity between mean K and TK values in healthy eyes, with rare clinical implications for IOL power calculation. Noteworthy differences were observed in astigmatism values between K and TK. Future investigations should delve into the practicality of TK values for astigmatism correction and their implications for surgical outcomes.


Asunto(s)
Astigmatismo , Lentes Intraoculares , Facoemulsificación , Humanos , Tomografía de Coherencia Óptica/métodos , Astigmatismo/diagnóstico , Reproducibilidad de los Resultados , Córnea , Biometría/métodos , Estudios Retrospectivos , Refracción Ocular
6.
Clin Exp Ophthalmol ; 52(1): 31-41, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38050340

RESUMEN

BACKGROUND: To evaluate the intraindividual visual performance of a spherical and extended depth of field (EDOF) IOL used in a mix-and-match approach. METHODS: Single centre (tertiary care centre), retrospective consecutive case series. Included patients had uneventful cataract surgery with implantation of a spherical monofocal IOL (CT Spheris 204) in the dominant eye and a diffractive EDOF IOL (AT LARA 829) in the non-dominant eye. Monocular and binocular defocus curves and visual acuity at various distances were assessed. In addition, binocular reading speed, contrast sensitivity, and patient satisfaction using QOV, Catquest 9SF, and glare/halo questionnaires are reported. RESULTS: A total of 29 patients (58 eyes) were included. We observed significant intra-individual differences for monocular DCIVA, DCNVA, UIVA, and UNVA. There were no differences in monocular BCDVA or UDVA. The monocular defocus curves for the two IOLs significantly differed at defocus steps between -1.0 and -3.5 D. 93.10% of patients reported they would opt for the same combination of IOLs. CONCLUSION: Excellent uncorrected and corrected distance visual acuity was demonstrated in both groups. The mix-and-match approach described in this study yielded good intermediate vision and improved near vision with high-patient satisfaction.


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Refracción Ocular , Implantación de Lentes Intraoculares , Seudofaquia , Estudios Retrospectivos , Visión Binocular , Satisfacción del Paciente , Diseño de Prótesis
7.
Am J Ophthalmol ; 260: 182-189, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38104758

RESUMEN

PURPOSE: To investigate the sociodemographic profile, the association with retinal vascular diseases (RVD) and systemic comorbidities, and visual outcomes of patients with paracentral acute middle maculopathy (PAMM) in a large, ethnically diverse single-center cohort. DESIGN: Retrospective cohort study. METHODS: Electronic health record query for all patients presenting with PAMM at Moorfields Eye Hospital, London, was completed. Detailed demographic, clinical, and systemic information were collected and analyzed. RESULTS: A total of 78 eyes of 78 patients with confirmed PAMM were included in the study. Forty patients (51.3%) presented with no RVD, 20 patients (25.6%) with retinal vein occlusion (RVO), 16 patients (20.5%) with retinal artery occlusion (RAO), and 2 patients (2.6%) with concomitant RAO and RVO. Patients with PAMM+RAO were older than those with RVO (P = .02) and more likely to have a history of major adverse cardiovascular events (MACE) (P = .01), with a significantly worse presenting best corrected visual acuity (BCVA) (20/50) compared to patients with RVO (P = .02) and no RVD (P < .001). Individuals with isolated PAMM had a significantly higher prevalence of previous MACE (P = .04) and sickle cell disease (SCD) (P = .04) compared to those with RVO. At the last follow-up, 64 patients (85.3%) had a good BCVA (>20/32). CONCLUSIONS: The significant association of PAMM with RVD supports the hypothesis of an ischemic etiology. Individuals with isolated PAMM had a higher prevalence of MACE and SCD. Thus, it is important to prompt immediate referral for a comprehensive systemic evaluation. Across the whole cohort, PAMM was associated with good BCVA improvement during follow-up, indicating a good visual prognosis.


Asunto(s)
Mácula Lútea , Degeneración Macular , Oclusión de la Arteria Retiniana , Enfermedades de la Retina , Oclusión de la Vena Retiniana , Humanos , Vasos Retinianos , Estudios Retrospectivos , Angiografía con Fluoresceína , Tomografía de Coherencia Óptica , Agudeza Visual , Enfermedad Aguda , Enfermedades de la Retina/diagnóstico , Enfermedades de la Retina/epidemiología , Enfermedades de la Retina/complicaciones , Oclusión de la Vena Retiniana/complicaciones , Oclusión de la Arteria Retiniana/complicaciones , Oclusión de la Arteria Retiniana/diagnóstico , Oclusión de la Arteria Retiniana/epidemiología , Prevalencia , Degeneración Macular/complicaciones
8.
Transl Vis Sci Technol ; 12(11): 34, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-38019500

RESUMEN

Purpose: The purpose of this study was to investigate the diagnostic value of anterior segment optical coherence tomography (AS-OCT) scans for Pseudomonas keratitis. Methods: Patients with treatment-naïve keratitis underwent AS-OCT imaging. The following parameters were evaluated: corneal thickness (CT), infiltrate thickness (IT), infiltrate diameter (ID), tissue loss/gain, entropy, and distance of the lesion from the corneal pupillary center. Three different OCT devices were used for the analysis. The relationship between the detected pathogen and the OCT patterns was analyzed. Results: Nineteen eyes of 19 patients were included in the analysis: seven cases in the Pseudomonas group and 12 cases in the Gram-positive group. The mean (SD) values for the Pseudomonas and Gram-positive groups, respectively, were as follows: CT, 834 µm (165 µm) and 760 µm (120 µm); IT, 290 µm (152 µm) and 287 µm (84 µm); ID, 2067 µm (1470 µm) and 1307 µm (745 µm); distance to center, 3.0 mm (1.2 mm) and 3.0 mm (1.6 mm); epithelial defect, 1193 µm (586 µm) and 484 µm (615 µm); tissue gain, +31% (19%) and +10% (12%); and entropy level, 4.0 (0.8) and 3.9 (1.1). Conclusions: This study introduces novel insights by identifying specific OCT parameters that distinguish Pseudomonas keratitis, including a 30% tissue gain. These findings align with earlier research that underscores the potential of OCT in differentiating various pathogens causing keratitis. Translational Relevance: The findings of this study could be used to develop new diagnostic strategies for Pseudomonas keratitis. The OCT findings could be used to develop new biomarkers for the infection.


Asunto(s)
Queratitis , Tomografía de Coherencia Óptica , Humanos , Queratitis/diagnóstico por imagen , Córnea/diagnóstico por imagen , Pseudomonas , Pupila
9.
Retina ; 43(11): 2027-2029, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37870910

RESUMEN

PURPOSE: To report a technique for scleral buckling surgery under the operating microscope with wide-field viewing. METHODS: The identification and reliable marking of retinal breaks is one of the key steps for successful surgery in scleral buckling. For sufficient visualization of retinal breaks, some kind of indentation and illumination is necessary. In this technique, one instrument (Visible Periphery illuminated scleral indentor; Oertli Instrumente AG, Switzerland) combines scleral depression, illumination, and color marking (using a surgical marking pen) of the corresponding sclera above the retinal break. RESULTS: The illuminated scleral depressor enables the surgeon to safely and precisely mark the retinal break while stabilizing and rotating the eye with the other hand. This technique simplifies scleral buckling surgery by improving the handling and visualization of marking retinal breaks at the corresponding scleral. Neither intraoperative indirect ophthalmoscopy nor sclerotomies for chandelier light systems or any intraocular instrument are necessary. CONCLUSION: The illuminated scleral depressor facilitates scleral buckling surgery in a convenient way for easy and precise scleral marking of the retinal breaks even in challenging situations and positions of retinal breaks under the operating microscope with wide-field viewing. Indirect ophthalmology or other illumination sources are no longer needed.


Asunto(s)
Desprendimiento de Retina , Perforaciones de la Retina , Humanos , Curvatura de la Esclerótica/métodos , Esclerótica/cirugía , Perforaciones de la Retina/cirugía , Desprendimiento de Retina/cirugía , Estudios Retrospectivos , Agudeza Visual , Resultado del Tratamiento
10.
J Cataract Refract Surg ; 49(10): 1025-1035, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37532255

RESUMEN

PURPOSE: To determine (1) if measurements of surgically induced astigmatism (SIA) as measured by keratometry (K) and total keratometry (TK) differ (2) if SIA affects the magnitude and/or meridian of keratometric astigmatism (3) if SIA evolves over time. SETTING: Tertiary care center. DESIGN: Retrospective data analysis. METHODS: A swept-source optical coherence tomography biometry dataset (IOLMaster700) consisting of 498 eyes (327 patients) from a tertiary care center was analyzed. For all eyes preoperative and postoperative biometric measurements at 1-month, 3-month, and 6-months postoperative visits were considered for vector analysis of SIA K and SIA TK . RESULTS: Centroids in right and left eyes were 0.26 diopters (D) @5 degrees/0.31 D @1 degree for SIA K and 0.27 D @4 degrees/0.34 D @1 degree for SIA TK . Centroids for difference vectors K-TK in right and left eyes were 0.02 D @ 176 degrees/0.03 D @6 degrees. The mean SIA magnitudes in right and left eyes were 0.48 ± 0.41 D and 0.50 ± 0.37 D for SIA K and 0.53 ± 0.42 D and 0.54 ± 0.40 D for SIA TK . In eyes with ATR astigmatism, an increase in postoperative astigmatism magnitude was more common than a decrease. More than 30% of eyes showed changes in the meridian of more than 15 degrees. CONCLUSIONS: Overall, we observed differences in K- and TK-derived SIA, and changes in SIA magnitude over time. For postsurgical interventions, postoperative astigmatism meridian values should be measured to base treatments. Astigmatism magnitude showed a tendency to decrease for steep-meridian incisions and to increase in flat-meridian incisions.


Asunto(s)
Astigmatismo , Extracción de Catarata , Catarata , Facoemulsificación , Humanos , Astigmatismo/diagnóstico , Astigmatismo/etiología , Astigmatismo/cirugía , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Córnea/cirugía , Topografía de la Córnea , Facoemulsificación/métodos
11.
Br J Ophthalmol ; 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-37495264

RESUMEN

PURPOSE: The purpose of this study was to develop a concept for predicting the effects of both discrete intraocular lens (IOL) power steps (PS) and power labelling tolerances (LT) on the uncertainty of the refractive outcome (REFU). DESIGN: Retrospective non-randomised cross-sectional Monte Carlo simulation study. METHODS: We evaluated a dataset containing 16 669 IOLMaster 700 preoperative biometric measurements. The PS and the delivery range of two modern IOLs (Bausch and Lomb enVista and Alcon SA60AT) were considered for this Monte Carlo simulation. The uncertainties from PS or LT were assumed to be normally distributed according to ±½ the IOL PS or the ISO 11979 LT. REFU was recorded and analysed for all simulations. RESULTS: With both lenses the REFU from discrete PS ranged from 0.11 to 0.12 dpt. Due to the larger PS for low/high power lenses with the enVista/SA60AT, REFU is more dominant in initially myopic/hyperopic eyes. REFU from LT ranged from 0.18 to 0.19 dpt for both lenses. Since LT increases stepwise with IOL power, REFU is more prevalent in initially hyperopic eyes requiring high IOL power values, and for lenses with a wide delivery range towards higher powers. CONCLUSIONS: Since surgeons and patients are typically aware of the effect of discrete PS on REFU, these might be tolerated in cataract surgery. However, REFU resulting from LT is inevitable while the true measured IOL power is not reported on the package, leading to background noise in postoperative achieved refraction.

12.
Curr Eye Res ; 48(8): 719-723, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37144469

RESUMEN

PURPOSE: To evaluate corneal stiffening of porcine corneas induced by corneal crosslinking (CXL) with constant irradiance as a function of total fluence. METHODS: Ninety corneas from freshly enucleated porcine eyes were divided into five groups of 18 eyes. Groups 1-4 underwent epi-off CXL using a dextran-based riboflavin solution and an irradiance of 18 mW/cm2, group 5 served as the control group. Groups 1 to 4 were treated with a total fluence of 20, 15, 10.8, and 5.4 J/cm2, respectively. Thereafter, biomechanical measurements were performed on 5 mm wide and 6 mm long strips using an uniaxial material tester. Pachymetry measurements were performed on each cornea. RESULTS: At 10% strain, the stress was 76, 56, 52, and 31% higher in groups 1-4, respectively compared to the control group. The Young's modulus was 2.85 MPa for group 1, 2.53 MPa for group 2, 2.46 MPa for group 3, 2.12 MPa for group 4, and 1.62 MPa for the control group. The difference between groups 1 to 4 and the control group 5 were statistically significant (p = <0.001; p = <0.001; p = <0.001; p = 0.021). In addition, group 1 showed significantly more stiffening than group 4 (p = <0.001), no other significant differences were found. Pachymetry measurements revealed no statistically significant differences among the five groups. CONCLUSION: Additional mechanical stiffening can be achieved by increasing the fluence of the CXL. There was no threshold detected up to 20 J/cm2. A higher fluence could compensate the weaker effect of accelerated or epi-on CXL procedures.


Asunto(s)
Fármacos Fotosensibilizantes , Rayos Ultravioleta , Porcinos , Animales , Fármacos Fotosensibilizantes/farmacología , Reactivos de Enlaces Cruzados/farmacología , Colágeno/farmacología , Fenómenos Biomecánicos/fisiología , Córnea , Riboflavina/farmacología , Sustancia Propia , Paquimetría Corneal
13.
J Ophthalmol ; 2023: 3165965, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36660315

RESUMEN

Purpose: In Austria, anti-VEGF therapies are reimbursed only in clinical settings. This study aimed to describe the outcome of a treat and extend regimen (TER) with aflibercept for diabetic macular edema (DME) in a network of practitioners. Methods: In a prospective study over 36 months, patients with DME were treated with a loading dose of aflibercept and further on with adjusted treatment intervals based on optical coherence tomography (OCT) findings. All patients were monitored in an outpatient setting by regional ophthalmologists, and the treatment was administered in the clinic. Main outcome parameters were best-corrected visual acuity (BCVA) from baseline to the last regular visit. Number of visits at the practitioner's office as well as the number of injections were secondary outcome parameters. Results: Thirty-three patients completed the study at their final visit. BCVA improved significantly by 5.8 letters between baseline and the final visit from 70.4 letters at baseline (p=0.004). Patients visited the practitioner's office 12.8 times in the observation period of 36 months. 3.7, 5.1, and 3.9 visits were performed, respectively, in the first, second, and third years, and 25.5 ± 7.9 injections were performed. The mean interval of injections over the observation period was 6.2 ± 2.2 in weeks. Conclusion: The treat and extend regimen was valuable for treating patients with DME in this specific setting. The functional results of this study were comparable to those of other real-world evaluations. Adherence to the same treating institution seems to be important to avoid differences in therapeutic decision making and may also increase patient's compliance.

14.
J Cataract Refract Surg ; 49(2): 119-125, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36100168

RESUMEN

PURPOSE: To evaluate the accuracy of phakic intraocular lens (pIOL) power calculation in a middle European patient cohort. SETTING: EyeLaser Clinic, Linz, Austria. DESIGN: Single-center single-surgeon retrospective consecutive case series. METHODS: Patients were included after uneventful pIOL surgery implanting 91 nontoric and toric Visian implantable collamer lens model V4c. Online Calculation and Ordering System (OCOS) software, JPhakic software, Olsen-Feingold formula, Holladay formula, and Linz-Homburg-Castrop (LHC) formula were compared. When possible, lens constants were optimized for the patient cohort. Data of single eye per patient were included. Outcome measures were mean absolute prediction error, median absolute prediction error, mean prediction error with SD, and median prediction error, as well as the percentage of eyes with an absolute prediction error within limits of 0.25 diopters (D), 0.5 D, 0.75 D, and 1.0 D. RESULTS: 91 eyes of 91 patients were assessed. After application of the Cochran Q test, the Olsen-Feingold formula achieved a significantly lower percentage of eyes within an absolute prediction error of 1.0 D than all other methods. CONCLUSIONS: In the patient cohort, OCOS software, JPhakic software, and Holladay and LHC formulas showed equal results and can be cross-checked. The LHC formula was not published before. A ready-to-use Excel sheet is available as an addendum.


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Lentes Intraoculares Fáquicas , Humanos , Refracción Ocular , Implantación de Lentes Intraoculares , Estudios Retrospectivos , Biometría/métodos , Óptica y Fotónica
15.
Am J Ophthalmol ; 245: 44-60, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36084683

RESUMEN

PURPOSE: To analyze Abulafia-Koch regression (AKRT), anterior and posterior astigmatism (K and TK), and evaluate biometry data in a large population. DESIGN: Retrospective cross-sectional study. METHODS: This multicenter (2 tertiary care centers) study analyzed datasets acquired between 2017 and 2020. Axial length (AL), corneal front and back radii (including meridians for K and TK conversion), horizontal corneal diameter, anterior chamber depth, lens thickness, and central corneal thickness were measured using telecentric keratometry and swept-source optical coherence tomography-based biometry (IOLMaster 700; Carl Zeiss Meditec AG). Cooke-modified axial length (CMAL) and AKRT were calculated. Difference vectors between K and TK astigmatism and between AKRT and TK astigmatism were compared. RESULTS: A total of 10,300 eyes from 6388 patients were assessed. Difference vectors for K and TK were significantly smaller than for AKRT and TK. K measurement showed a configuration of 51.49% of with-the-rule astigmatism and 30.51% against-the-rule astigmatism, TK measurement showed a configuration of 41.60% of with-the-rule astigmatism and 40.21% against-the-rule astigmatism. Mean total astigmatism was -0.94 ± 0.74 dpt. Mean values for AL and CMAL were 23.70 ± 1.39 mm and 23.70 ± 1.34 mm, respectively. Anterior chamber depth, lens thickness, horizontal corneal diameter, AL, and age were all correlated with each other. CONCLUSION: Astigmatism analysis showed less difference between K and TK than between AKRT and TK. There were significantly fewer eyes with with-the-rule astigmatism and more eyes with against-the-rule astigmatism configuration in TK-derived than in K-derived keratometry. The study provides data on gender and generational differences in biometry. Significant intersexual differences in AL and CMAL were observed, with CMAL providing lower standard deviation compared with AL.


Asunto(s)
Astigmatismo , Humanos , Astigmatismo/diagnóstico , Tomografía de Coherencia Óptica , Longitud Axial del Ojo/anatomía & histología , Estudios Retrospectivos , Estudios Transversales , Biometría/métodos , Córnea/anatomía & histología , Reproducibilidad de los Resultados
16.
Am J Ophthalmol ; 247: 79-87, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36370839

RESUMEN

PURPOSE: To develop and test a novel index (Cooke-Riaz-Wendelstein [CRW1]) that uses swept-source optical coherence tomography (SS-OCT) biometry measurements (IOLMaster700, Zeiss Meditec), including total keratometry, to alert clinicians that previous myopic laser vision correction (M-LVC) was present in a measured eye. DESIGN: Retrospective, multicenter, comparative diagnostic analysis. METHODS: The study took place at 6 centers in the United States and Austria. Anonymized SS-OCT biometry datasets acquired between 2018 and 2020 and containing 49,199 eyes were analyzed. The LVC status, as identified by the biometrist, was used to segregate eyes into LVC and non-LVC eyes. Data were split into training (10,780 eyes) and validation (38,419 eyes) sets. Subset analysis was performed for CRW1 Index accuracy compared to posterior/anterior corneal curvature ratio (Rpost/Rant), topography with corneal analysis software (Atlas 9000 with Pathfinder II, Zeiss Meditec), tomography (Pentacam, Oculus), dual Scheimpflug-Placido system (Galilei G6, Ziemer), and a cloud-based platform for cataract surgery planning (Veracity, Zeiss Meditec). A positive predictive value (PPV) of ≥90% was targeted for the CRW1 index. True positives, true negatives, sensitivity, and specificity were recorded. RESULTS: The CRW1 Index compared favorably against Rpost/Rant showing a higher PPV (93% vs 65%), with fewer false-positive results (29 vs 180). CRW1 performed similarly to topography software and better than the corneal imaging devices. The CRW1 cutoff value can be adjusted to increase sensitivity (CRW1-IS) to detect additional M-LVC eyes. CONCLUSIONS: The CRW1 and CRW1-IS indices offer surgeons and researchers a readily accessible method to use only SS-OCT biometry measurements to detect eyes with a high probability of previous M-LVC.


Asunto(s)
Miopía , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Estudios Retrospectivos , Córnea/anatomía & histología , Miopía/cirugía , Biometría/métodos , Rayos Láser , Reproducibilidad de los Resultados , Longitud Axial del Ojo
17.
Int J Mol Sci ; 23(15)2022 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-35955800

RESUMEN

Millions of people worldwide are diagnosed with retinal dystrophies such as retinitis pigmentosa and age-related macular degeneration. A retinal prosthesis using organic photovoltaic (OPV) semiconductors is a promising therapeutic device to restore vision to patients at the late onset of the disease. However, an appropriate cytotoxicity approach has to be employed on the OPV materials before using them as retinal implants. In this study, we followed ISO standards to assess the cytotoxicity of D18, Y6, PFN-Br and PDIN individually, and as mixtures of D18/Y6, D18/Y6/PFN-Br and D18/Y6/PDIN. These materials were proven for their high performance as organic solar cells. Human RPE cells were put in direct and indirect contact with these materials to analyze their cytotoxicity by the MTT assay, apoptosis by flow cytometry, and measurements of cell morphology and proliferation by immunofluorescence. We also assessed electrophysiological recordings on mouse retinal explants via microelectrode arrays (MEAs) coated with D18/Y6. In contrast to PFN-Br and PDIN, all in vitro experiments show no cytotoxicity of D18 and Y6 alone or as a D18/Y6 mixture. We conclude that D18/Y6 is safe to be subsequently investigated as a retinal prosthesis.


Asunto(s)
Retinitis Pigmentosa , Prótesis Visuales , Animales , Electrodos Implantados , Humanos , Ratones , Microelectrodos , Retina
18.
Eur J Ophthalmol ; 32(6): 3195-3200, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35786024

RESUMEN

INTRODUCTION: To report a late onset, deep stromal and endothelial corneal scar in a keratoconus patient after corneal collagen cross-linking (CXL). CASE DESCRIPTION: Observational case report. A 29-year-old man with bilateral keratoconus received an accelerated (A-CXL 10*9) epithelium-off CXL procedure in the left eye.6-months postoperatively, a 2.2 × 1.2 mm inferocentral corneal scar was detected, which was located in the posterior stroma ranging from approximately 350 µm until the endothelium, therefore was situated below the demarcation line. A topical corticosteroid treatment did not influence the magnitude or configuration of the scar. Visual acuity was never affected, which includes the examination 12 months postoperatively. CONCLUSIONS: We report a case of a late onset deep stromal and endothelial corneal scar 6 months after accelerated CXL as postoperative complication without affecting visual acuity.


Asunto(s)
Lesiones de la Cornea , Queratocono , Fotoquimioterapia , Adulto , Cicatriz/etiología , Colágeno/uso terapéutico , Sustancia Propia/patología , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Endotelio , Humanos , Queratocono/patología , Masculino , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Riboflavina/uso terapéutico , Rayos Ultravioleta
19.
Graefes Arch Clin Exp Ophthalmol ; 260(12): 3869-3882, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35776171

RESUMEN

BACKGROUND: Overall ocular magnification (OOM) and meridional ocular magnification (MOM) with consequent image distortions have been widely ignored in modern cataract surgery. The purpose of this study was to investigate OOM and MOM in a general situation with an astigmatic refracting surface. METHODS: From a large dataset containing biometric measurements (IOLMaster 700) of both eyes of 9734 patients prior to cataract surgery, the equivalent (PIOLeq) and cylindric power (PIOLcyl) were derived for the HofferQ, Haigis, and Castrop formulae for emmetropia. Based on the pseudophakic eye model, OOM and MOM were extracted using 4 × 4 matrix algebra for the corrected eye (with PIOLeq/PIOLcyl (scenario 1) or with PIOLeq and spectacle correction of the residual refractive cylinder (scenario 2) or with PIOLeq remaining the residual uncorrected refractive cylinder (blurry image) (scenario 3)). In each case, the relative image distortion of MOM/OOM was calculated in %. RESULTS: On average, PIOLeq/PIOLcyl was 20.73 ± 4.50 dpt/1.39 ± 1.09 dpt for HofferQ, 20.75 ± 4.23 dpt/1.29 ± 1.01 dpt for Haigis, and 20.63 ± 4.31 dpt/1.26 ± 0.98 dpt for Castrop formulae. Cylindric refraction for scenario 2 was 0.91 ± 0.70 dpt, 0.89 ± 0.69 dpt, and 0.89 ± 0.69 dpt, respectively. OOM/MOM (× 1000) was 16.56 ± 1.20/0.08 ± 0.07, 16.56 ± 1.20/0.18 ± 0.14, and 16.56 ± 1.20/0.08 ± 0.07 mm/mrad with HofferQ; 16.64 ± 1.16/0.07 ± 0.06, 16.64 ± 1.16/0.18 ± 0.14, and 16.64 ± 1.16/0.07 ± 0.06 mm/mrad with Haigis; and 16.72 ± 1.18/0.07 ± 0.05, 16.72 ± 1.18/0.18 ± 0.14, and 16.72 ± 1.18/0.07 ± 0.05 mm/mrad with Castrop formulae. Mean/95% quantile relative image distortion was 0.49/1.23%, 0.41/1.05%, and 0.40/0.98% for scenarios 1 and 3 and 1.09/2.71%, 1.07/2.66%, and 1.06/2.64% for scenario 2 with HofferQ, Haigis, and Castrop formulae. CONCLUSION: Matrix representation of the pseudophakic eye allows for a simple and straightforward prediction of OOM and MOM of the pseudophakic eye after cataract surgery. OOM and MOM could be used for estimating monocular image distortions, or differences in overall or meridional magnifications between eyes.


Asunto(s)
Catarata , Cristalino , Lentes Intraoculares , Facoemulsificación , Humanos , Refracción Ocular , Biometría/métodos , Estudios Retrospectivos
20.
BMC Ophthalmol ; 22(1): 195, 2022 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-35477372

RESUMEN

BACKGROUND: We describe a case of an atypical presentation of leukemic optic nerve infiltration. CASE PRESENTATION: A patient with acute lymphoblastic leukemia (ALL) in remission suffered from sudden right eye vision loss. At the time of presentation, the affected eye presented with an afferent pupillary defect, while the fundus examination was normal. A complete work up of the patient revealed no signs of ALL relapse, but MR imaging of the optic nerve showed contrast agent uptake consistent with optic nerve infiltration. The patient developed a fulminant ALL relapse and died shortly after. Histology of the optic nerve showed a leukemic infiltration with CD10 positive cells. CONCLUSIONS: This is the first report of an ALL relapse in the optic nerve without intraocular signs. Patients' medical history should therefore be taken into consideration in patients with unclear vision loss.


Asunto(s)
Nervio Óptico , Leucemia-Linfoma Linfoblástico de Células Precursoras , Fondo de Ojo , Humanos , Infiltración Leucémica/diagnóstico , Infiltración Leucémica/patología , Nervio Óptico/diagnóstico por imagen , Nervio Óptico/patología , Leucemia-Linfoma Linfoblástico de Células Precursoras/complicaciones , Leucemia-Linfoma Linfoblástico de Células Precursoras/diagnóstico , Recurrencia