Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Nucl Med Commun ; 20(11): 1077-84, 1999 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-10572919

RESUMEN

A multicentre survey of the quality control of 99Tcm generators has been completed: 245 generators from seven different commercial sources were tested over a period of 2 years. The results indicate that the mean pH of the eluates was 5.8 +/- 0.6; the aluminium contents were typically < 10 ppm; the radiochemical purity was 99.8 +/- 0.4% and the median 99Mo content was 3.8 x 10(-4) percent. The elution profiles gave a volume of 1.9 ml to obtain 50% of the total eluted activity and of 4.9 ml to obtain 95%. Other radionuclide impurities and heavy metal breakthrough were evaluated by graphite furnace absorption spectrometry and inductively coupled plasma mass spectrometry. National guidelines for the standardization of radiopharmacy procedures are currently being compiled.


Asunto(s)
Molibdeno/química , Generadores de Radionúclidos/normas , Radiofármacos/normas , Tecnecio/química , Concentración de Iones de Hidrógeno , Indicadores y Reactivos , Italia , Molibdeno/aislamiento & purificación , Control de Calidad , Radioisótopos , Radiofármacos/química , Radiofármacos/aislamiento & purificación , Espectrofotometría Atómica , Tecnecio/aislamiento & purificación , Oligoelementos/análisis
2.
Eur J Nucl Med ; 22(6): 532-6, 1995 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-7556298

RESUMEN

Simultaneous measurements of the clearance rate of chromium-51 ethylene diamine tetra-acetic acid (51Cr-EDTA) and technetium-99m diethylene triamine penta-acetic acid (99mTc-DTPA) were performed in 54 patients with a range of function between 9 and 176 ml/min. Using multiple blood samples the two clearance values correlated well (r = 0.97, SEE 8.6 ml/min) and DTPA clearance was higher by 2.9%. For each radiopharmaceutical the plasma clearance rates obtained using multiple blood samples were compared with those obtained with simplified methods, i.e., the 60-180 min two-sample method of Russell and the mono-exponential method with the Brochner-Mortensen correction. For both radiopharmaceuticals the clearance values correlated well with the Russell method (r = 0.99, SEE = 4.1 ml/min for EDTA; r = 0.99, SEE 4.9 ml/min for DTPA) and the mono-exponential method (r = 0.99, SEE 3.6 ml/min for EDTA; r = 0.99, SEE 3.9 ml/min for DTPA). The mean plasma clearance obtained using multiple blood samples did not differ significantly from that obtained with the Russell method, either in patients with a glomerular filtration rate (GFR) < 30 ml/min or in patients with GFR > or = 30 ml/min. The mean plasma clearance obtained using multiple blood samples differed significantly from that obtained with the mono-exponential method because of the great difference observed in patients with GFR > or = 30 ml/min. It is concluded that the Russell two-sample method after injection of 99mTc-DTPA is accurate enough for routine clinical use.


Asunto(s)
Radioisótopos de Cromo , Ácido Edético , Tasa de Filtración Glomerular , Pentetato de Tecnecio Tc 99m , Radioisótopos de Cromo/farmacocinética , Ácido Edético/farmacocinética , Femenino , Humanos , Riñón/fisiología , Masculino , Persona de Mediana Edad , Pentetato de Tecnecio Tc 99m/farmacocinética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...