Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Lancet Reg Health Eur ; 2: 100030, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34173627

RESUMEN

BACKGROUND: A reduction of admission for MI has been reported in most countries affected by COVID-19. No clear explanation has been provided. METHODS: To report the incidence of myocardial infarction (MI) admission during COVID-19 pandemic and in particular during national lockdown in two unequally affected French provinces (10-million inhabitants) with a different media strategy, and to describe the magnitude of MI incidence changes relative to the incidence of COVID-19-related deaths. A longitudinal study to collect all MIs from January 1 until May 17, 2020 (study period) and from the identical time period in 2019 (control period) was conducted in all centers with PCI-facilities in northern "Hauts-de-France" province and western "Pays-de-la-Loire" Province. The incidence of COVID-19 fatalities was also collected. FINDINGS: In "Hauts-de-France", during lockdown (March 18-May 10), 1500 COVID-19-related deaths were observed. A 23% decrease in MI-IR (IRR=0.77;95%CI:0.71-0.84, p<0.001) was observed for a loss of 272 MIs (95%CI:-363,-181), representing 18% of COVID-19-related deaths. In "Pays-de-la-Loire", 382 COVID-19-related deaths were observed. A 19% decrease in MI-IR (IRR=0.81; 95%CI=0.73-0.90, p<0.001) was observed for a loss of 138 MIs (95%CI:-210,-66), representing 36% of COVID-19-related deaths. While in "Hauts-de-France" the MI decline started before lockdown and recovered 3 weeks before its end, in "Pays-de-la-Loire", it started after lockdown and recovered only by its end. In-hospital mortality of MI patients was increased during lockdown in both provinces (5.0% vs 3.4%, p=0.02). INTERPRETATION: It highlights one of the potential collateral damages of COVID-19 outbreak on cardiovascular health with a dramatic reduction of MI incidence. It advocates for a careful and weighted communication strategy in pandemic crises. FUNDING: The study was conducted without external funding.

2.
Catheter Cardiovasc Interv ; 98(1): E9-E17, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32966675

RESUMEN

BACKGROUND: Bifurcation lesions in coronary arteries are complex to treat with coronary stents, which are not designed for that purpose and can be unproperly deployed. Moreover, devices are constantly evolving, and so are angioplasty techniques. OBJECTIVES: The aim of this study was to determine the performances of different stents in the treatment of bifurcation lesions using the re-proximal optimization technique (rePOT). METHODS: Eleven stent platforms were evaluated: Xience Sierra (Abbott), Xience Alpine (Abbott), Synergy (Boston), Coroflex Isar (Bbraun), Cobra PzF (Celonova), Ultimaster (Terumo), Resolute Integrity (Medtronic), Resolute Onyx (Medtronic), Optimax (Hexacath), Orsiro (Biotronik), and Absorb (Abbott). Stents were deployed in a silicone fractal bifurcation model using the rePOT. Micro-computed tomography was performed to assess side branch ostium coverage and strut malapposition, as well as the effect of rePOT on stent cell area. RESULTS: Our study showed significant differences between stent platforms regarding side branch ostium coverage (p = .002). The Synergy and Cobra PzF stents were the most performant devices to avoid ostium coverage. Strut malapposition varied significantly between devices (p = .008) but the percentage of malapposed struts was relatively low. Significant differences were observed between stents regarding the cell area before (p = .002) and also after rePOT (p = .003), and the increase in cell area caused by rePOT varied considerably between devices (p = .08). CONCLUSION: This study highlighted significant differences in the performances of stent platforms deployed in a fractal bifurcation model using rePOT, with a variable impact of the procedure on stent cell area.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Fractales , Humanos , Diseño de Prótesis , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Microtomografía por Rayos X
3.
Cardiovasc Eng Technol ; 11(6): 719-724, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33025369

RESUMEN

PURPOSE: Interventional cardiology devices and especially stents are constantly evolving. A good radiopacity is essential to properly position the stent and to reduce the risk of complications during percutaneous coronary intervention (PCI). We wanted to assess the radiopacity of coronary stents. METHODS: 9 stents were evaluated. Stents were deployed in a silicon bifurcation model and several pulsed fluoroscopy acquisitions (7.5 and 15 pulses/s) of each device were performed in a catheterization laboratory. Quantitative radiopacity assessment was performed using a radiopacity visual scale and qualitative radiopacity assessment was performed by showing the images to three experienced operators, single-blind. RESULTS: Our study showed statistically significant differences between stents regarding radiopacity assessed in a quantitative analysis (p < 0.000001) or a qualitative analysis (p < 0.000001), whether the acquisitions were made in 7.5 or 15 pulses/s. Resolute Onyx and Synergy were the most radio-opaque in both qualitative and qualitative analysis. Moreover, there was a statistically significant correlation between the radiopacity of stents, their strut thickness (p < 0.0001) and the presence of platinum in their metallic alloy (p < 0.0001). CONCLUSION: This study highlighted significant differences in the radiopacity of coronary stents deployed in a bench test model. The strut thickness and the presence of platinum increased the radiopacity.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Stents , Fluoroscopía , Humanos , Ensayo de Materiales , Modelos Cardiovasculares , Diseño de Prótesis , Método Simple Ciego
4.
Catheter Cardiovasc Interv ; 92(7): E465-E470, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-30269427

RESUMEN

OBJECTIVES: The purpose of the study was to develop a standardized and global bench test protocol to evaluate the biomechanical characteristics of the most currently used drug-eluting coronary stents. BACKGROUND: The use of coronary stents has contributed to the reduction of cardiovascular mortality but can be associated with specific complications. Improving the biomechanical matching between the stents and the coronary anatomy may reduce these complications. METHODS: We assessed five commercially available drug-eluting stents: the Absorb, Orsiro, Resolute Onyx, Synergy, and Xience Alpine stents. Following stent deployment at nominal pressure in ambient air, radial elastic recoil and foreshortening were measured. Flexibility (crimped and deployed stents) and longitudinal and radial resistances were evaluated using a mechanical tester. RESULTS: Biomechanical characteristics were significantly different for all tested devices (ANOVA, P < 0.01). The Synergy, Orsiro, and Xience Alpine stents presented the lowest elastic recoil. The Synergy and Resolute Onyx stents were the most flexible devices. The Xience Alpine and Absorb stents had the highest longitudinal and radial resistances. CONCLUSIONS: Drug-eluting coronary stents used in current clinical practice have very different biomechanical characteristics, which should be taken into consideration to select the most appropriate device for each clinical situation.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Fuerza Compresiva , Elasticidad , Ensayo de Materiales , Presión , Diseño de Prótesis , Falla de Prótesis , Estrés Mecánico
5.
J Am Heart Assoc ; 7(4)2018 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-29440010

RESUMEN

BACKGROUND: Morphine is commonly used to treat chest pain during myocardial infarction, but its effect on cardiovascular outcome has never been directly evaluated. The aim of this study was to examine the effect and safety of morphine in patients with acute anterior ST-segment elevation myocardial infarction followed up for 1 year. METHODS AND RESULTS: We used the database of the CIRCUS (Does Cyclosporine Improve Outcome in ST Elevation Myocardial Infarction Patients) trial, which included 969 patients with anterior ST-segment elevation myocardial infarction, admitted for primary percutaneous coronary intervention. Two groups were defined according to use of morphine preceding coronary angiography. The composite primary outcome was the combined incidence of major adverse cardiovascular events, including cardiovascular death, heart failure, cardiogenic shock, myocardial infarction, unstable angina, and stroke during 1 year. A total of 554 (57.1%) patients received morphine at first medical contact. Both groups, with and without morphine treatment, were comparable with respect to demographic and periprocedural characteristics. There was no significant difference in major adverse cardiovascular events between patients who received morphine compared with those who did not (26.2% versus 22.0%, respectively; P=0.15). The all-cause mortality was 5.3% in the morphine group versus 5.8% in the no-morphine group (P=0.89). There was no difference between groups in infarct size as assessed by the creatine kinase peak after primary percutaneous coronary intervention (4023±118 versus 3903±149 IU/L; P=0.52). CONCLUSIONS: In anterior ST-segment elevation myocardial infarction patients treated by primary percutaneous coronary intervention, morphine was used in half of patients during initial management and was not associated with a significant increase in major adverse cardiovascular events at 1 year.


Asunto(s)
Infarto de la Pared Anterior del Miocardio/terapia , Morfina/administración & dosificación , Antagonistas de Narcóticos/administración & dosificación , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST/terapia , Administración Intravenosa , Anciano , Angina Inestable/etiología , Infarto de la Pared Anterior del Miocardio/diagnóstico por imagen , Infarto de la Pared Anterior del Miocardio/mortalidad , Angiografía Coronaria , Bases de Datos Factuales , Femenino , Insuficiencia Cardíaca/etiología , Humanos , Masculino , Persona de Mediana Edad , Morfina/efectos adversos , Antagonistas de Narcóticos/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Medición de Riesgo , Factores de Riesgo , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/mortalidad , Choque Cardiogénico/etiología , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...