Talanta ; 176: 69-76, 2018 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-28917807

RESUMEN

A novel non-aqueous capillary electrophoresis - tandem mass spectrometry method for the simultaneous separation, identification and quantification of nine designer benzodiazepines (bentazepam, etizolam, deschloroetizolam, diclazepam, flubromazepam, flubromazolam, nimetazepam, phenazepam, and pyrazolam) was developed. A non-aqueous running electrolyte consisting of 25mM ammonium acetate with 100mM trifluoroacetic acid in acetonitrile was used. The separation was carried out using a semipermanent coated capillary (successive multiple ionic-polymer coating) with a strong anodic electroosmotic flow at a negative separation voltage within twelve minutes. Electrospray ionization with a triple quadrupole mass spectrometry was utilized for the identification and quantification of selected designer benzodiazepines in a positive ionization mode. The developed method was validated and applied on the analysis of spiked serum sample following a simple liquid-liquid extraction. The LODs of the designer benzodiazepines were between 1.5 and 15.0ngmL-1.


Asunto(s)
Benzodiazepinas/sangre , Drogas de Diseño/análisis , Electroforesis Capilar , Bromuro de Hexadimetrina/química , Humanos , Límite de Detección , Extracción Líquido-Líquido , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem