Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Healthcare (Basel) ; 12(10)2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38786411

RESUMEN

BACKGROUND: Evidence suggests the plantar fascia and its interphase with the flexor digitorum brevis muscle can play a relevant role in plantar heel pain. Needling interventions could offer an appropriate treatment strategy to addressing this interface. OBJECTIVE: We compared the accuracy and safety of ultrasound-guided versus palpation-guided procedures for the proper targeting of the interface between the plantar fascia and the flexor digitorum brevis with a solid needle. METHODS: A crossover cadaveric study was conducted. Five experienced therapists performed a series of 20 needle insertions each (n = 100 in total, 10 landmark-guided and 10 ultrasound-guided) on 10 anatomical samples. The therapists were instructed to accurately place the needle on the interface between the plantar fascia and the flexor digitorum brevis muscle. The distance of the tip of the needle to the identified target (accuracy), the surrounding sensitive structures targeted (safety), the time needed for the procedure, the number of needle passes, and the needle length outside the skin were assessed. RESULTS: The ultrasound-guided technique was associated with a significantly higher accuracy (p < 0.001) but without differences in safety (p = 0.249) as compared to the palpation-guided procedure. CONCLUSION: Our results suggest that ultrasound-guided insertion exhibits greater accuracy but not greater safety than palpation-guided insertion when targeting the interface between the plantar fascia and the flexor digitorum brevis.

2.
Life (Basel) ; 13(10)2023 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-37895441

RESUMEN

For decades, needling interventions have been performed based on manual palpation and anatomic knowledge. The increasing use of real-time ultrasonography in clinical practice has improved the accuracy and safety of needling techniques. Although currently ultrasound-guided procedures are routinely used for patellar tendon pathology, e.g., during percutaneous electrolysis, the accuracy of these procedures is still unknown. This study used a cadaveric model to compare and evaluate both the accuracy and safety of ultrasound-guided and palpation-guided needling techniques for the patellar tendon. A total of five physical therapists performed a series of 20 needle insertion task each (n = 100), 10 insertions based on manual palpation (n = 50) and 10 insertions guided with ultrasound (n = 50) to place a needle along the interface between the patellar tendon and Hoffa's fat pad. All procedures were performed on cryopreserved knee specimens. Distance to the targeted tissue, time of the procedure, accurate rate of insertions, number of passes, and unintentional punctured structures between both applications (with and without ultrasound guiding) were compared. The results revealed higher accuracy (100% vs. 80%), a lower distance from needle to the targeted tissue (0.25 ± 0.65 vs. 2.5 ± 1.9 mm), longer surface of contact with the needle (15.5 ± 6.65 vs. 4.7 ± 7.5 mm), and a lower frequency of patellar tendon puncture (16% vs. 52%, p < 0.001) with the ultrasound-guided procedure as opposed to palpation-guided one. Nevertheless, the ultrasound-guided procedure took longer (54.8 ± 26.8 vs. 23.75 ± 15.4 s) and required more passes (2.55 ± 1.9 vs. 1.5 ± 0.95) to be conducted than the palpation-guided procedure (all, p < 0.001). According to these findings, the accuracy of invasive procedures applied on the patellar tendon is higher when conducted with ultrasound guidance than when conducted just on manual palpation or anatomical landmark. These results suggest that ultrasound could improve the clinical application of invasive procedures at the fat-patellar tendon interface. Due to the anatomical features of the targeted tissue, some procedures require this precision, so the use of ultrasound is recommended.

3.
Pain Res Manag ; 2023: 1523834, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37664417

RESUMEN

The purpose of this systematic review and meta-analysis was to assess the short-, mid-, and long-term effectiveness of dry needling in improving pain and functional capacity of patients with chronic neck pain. Search strategy was performed on PubMed, Web of Science, Scopus, PEDro, and Cochrane Library Plus biomedical databases. The risk of bias was assessed using the RoB2 tool. Randomised controlled clinical trials in which at least 1 of the groups received dry needling were included. 662 studies were found; 14 clinical trials were selected for qualitative analysis and 13 for quantitative analysis. The quality of most of the studies included was "high." All the studies reported improvements in cervical pain and/or disability, regardless of the protocol followed and the muscles targeted. No serious adverse effects were reported. Dry needling showed to be more effective when compared with other therapies in both women and men, without differences by sex. When the analysis was carried out by age, patients over 40 years old benefitted more than those below 40 years old. Our meta-analysis supports the use of dry needling to improve pain and functional capacity in patients with chronic neck pain at short- and mid-term intervals.


Asunto(s)
Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Punción Seca , Masculino , Humanos , Femenino , Adulto , Dolor de Cuello/terapia , Bases de Datos Factuales , Músculos
4.
Am J Phys Med Rehabil ; 102(12): 1091-1096, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37205741

RESUMEN

OBJECTIVES: The aims of the study are to analyze and describe the accuracy of an ultrasound-guided approach to target the L5 root in cadaveric specimens and evaluate whether gender differences exist. DESIGN: A cross-anatomical study on 40 cadaver L5 nerve roots was performed. A needle was introduced until contacting the L5 nerve root using ultrasound guidance. After that, specimens were frozen and studied by a cross-anatomical view to see the needle's path. The angulation, length, distance from the vertebral spine, the relevant ultrasound anatomical references, and the accuracy of the procedure were evaluated. RESULTS: The needle tip reached the L5 root at a 72.5% rate. The mean angulation degrees of the needle relative to the skin surface were 75.53 ± 10.17 degrees, the length of the needle inserted was 5.83 ± 0.82 cm, and the distance from the vertebral spine to the point of entry of the needle was 5.39 ± 1.44 cm. CONCLUSIONS: An ultrasound-guided technique can potentially be an accurate technique to perform invasive procedures on the L5 root. There were statistically significant differences between males and females in the length of the needle introduced. If the L5 root is not clearly visualized, ultrasound will not be the technique of choice.


Asunto(s)
Vértebras Lumbares , Raíces Nerviosas Espinales , Masculino , Femenino , Humanos , Raíces Nerviosas Espinales/diagnóstico por imagen , Ultrasonografía , Vértebras Lumbares/diagnóstico por imagen , Ultrasonografía Intervencional/métodos , Cadáver
5.
Artículo en Inglés | MEDLINE | ID: mdl-36497812

RESUMEN

Percutaneous needle electrolysis (PNE) consists of the ultrasound-guided application of a galvanic electrical current through a solid filament needle. One proposed therapeutic mechanism for this intervention is a potential thermal effect. The aim of this study was to investigate if the application of PNE induces changes in temperature in different cadaveric musculoskeletal tissues. A repeated measure experimental cadaveric study was designed with 10 cryopreserved knees (5 men, 5 women). Sterile stainless-steel needles of 40 mm length and 0.30 mm caliber were used in this study. An ultrasound-guided needling puncture was performed in the targeted tissue (patellar tendon, infra-patellar fat, and vastus medialis muscle). Additionally, the tip of the needle was placed next to the thermometer sensor at the minimum possible distance without direct contact with it. The temperature differences before and after different applications were measured. The applications were: three applications for 3 s of 3 mA of intensity (3:3:3) when the tendon was the targeted tissue, three applications for 3 s of 1.5 mA of intensity (1.5:3:3) when the fat or muscle was the targeted tissue, and 24 s of 1 mA of intensity (1:24:1) in all tissues. No statistically significant Group*Time interactions were found in any tissue (tendon: F = 0.571, p = 0.459, ŋ2 = 0.03; fat pad: F = 0.093; p = 0.764, ŋ2 = 0.01; muscle: F = 0.681; p = 0.420, ŋ2 = 0.04). Overall, no changes in temperature were observed between both applications in the tendon (3:3:3 vs. 1:24:1) and fat/muscle (1.5:3:3 vs. 1:24:1) tissues. The application of two different percutaneous needle electrolysis protocols did not produce appreciable thermal changes in the tendon, fat, and muscle tissues of human cadavers. The results from the current cadaver study support that a thermal effect should not be considered as a mechanism of clinical action regardless of the targeted human tissue when applying percutaneous needle electrolysis since no changes in temperature after its application were observed.


Asunto(s)
Electrólisis , Ligamento Rotuliano , Masculino , Humanos , Femenino , Electrólisis/métodos , Proyectos de Investigación , Temperatura , Cadáver
6.
Biomed Res Int ; 2021: 9936981, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34189141

RESUMEN

BACKGROUND: Cervical radiculopathy is defined as a disorder involving dysfunction of the cervical nerve roots characterised by pain radiating and/or loss of motor and sensory function towards the root affected. There is no consensus on a good definition of the term. In addition, the evidence regarding the effectiveness of manual therapy in radiculopathy is contradictory. OBJECTIVE: To assess the effectiveness of manual therapy in improving pain, functional capacity, and range of motion in treating cervical radiculopathy with and without confirmation of altered nerve conduction. METHODS: Systematic review of randomised clinical trials on cervical radiculopathy and manual therapy, in PubMed, Web of Science, Scopus, PEDro, and Cochrane Library Plus databases. The PRISMA checklist was followed. Methodological quality was evaluated using the PEDro scale and RoB 2.0. tool. RESULTS: 17 clinical trials published in the past 10 years were selected. Manual therapy was effective in the treatment of symptoms related to cervical radiculopathy in all studies, regardless of the type of technique and dose applied. CONCLUSIONS: This systematic review did not establish which manual therapy techniques are the most effective for cervical radiculopathy with electrophysiological confirmation of altered nerve conduction. Without this confirmation, the application of manual therapy, regardless of the protocol applied and the manual therapy technique selected, appears to be effective in reducing chronic cervical pain and decreasing the index of cervical disability in cervical radiculopathy in the short term. However, it would be necessary to agree on a definition and diagnostic criteria of radiculopathy, as well as the definition and standardisation of manual techniques, to analyse the effectiveness of manual therapy in cervical radiculopathy in depth.


Asunto(s)
Vértebras Cervicales/fisiopatología , Manipulaciones Musculoesqueléticas/métodos , Dolor de Cuello/fisiopatología , Radiculopatía/fisiopatología , Ensayos Clínicos como Asunto , Electromiografía , Humanos , Rango del Movimiento Articular
7.
J Back Musculoskelet Rehabil ; 34(2): 243-249, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32831191

RESUMEN

BACKGROUND: The straight leg raise test (SLR) is one of the most performed physical tests for mechanosensitivity and impairment of the nervous system. According to the anatomy of the tibial nerve, ankle dorsiflexion and eversion movements could be used to perform the tibial neurodynamic test (TNT). To date, no study has documented the normal responses of the TNT. OBJECTIVE: To document normal responses of the TNT in asymptomatic individuals and to investigate influences from sex and leg dominance. METHODS: A cross-sectional study with 44 asymptomatic volunteer subjects, a total of 88 lower limbs, was carried out. The range of motion (ROM), quality, and distribution of sensory responses were recorded. The hip flexion ROM was measured when subjects reported an intensity of their symptoms of 2/10 (P1) and 8/10 (P2). RESULTS: The mean ROM for hip flexion at P1 was 44.22 ± 13.13∘ and 66.73 ± 14.30∘ at P2. Hip flexion was significantly greater at P2 than P1 (p< 0.001). However, it was not different between sex or limbs (p> 0.05). The descriptor of the quality of sensory responses most often used by participants was stretching (88.6% and 87.5% for P1 and P2, respectively) in the popliteal fossa and posterior calf. CONCLUSIONS: This study describes the sensory responses of asymptomatic subjects resulting from the TNT. Our findings indicate that TNT responses are independent of the influence of sex or leg dominance.


Asunto(s)
Articulación de la Cadera/fisiología , Pierna/fisiología , Rango del Movimiento Articular/fisiología , Nervio Tibial/fisiología , Adulto , Estudios Transversales , Femenino , Voluntarios Sanos , Humanos , Masculino , Movimiento/fisiología , Examen Neurológico , Valores de Referencia
8.
Musculoskelet Sci Pract ; 50: 102258, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32966955

RESUMEN

BACKGROUND: Neurodynamic tests (NDTs) consist of a combination of movements aimed to stress different parts of the nervous system and are considered to be able to detect increased nerve mechanosensitivity. Currently, there are no studies in healthy subjects that define the normal response to sural neurodynamic test (NDTSUR). OBJECTIVES: The main aim of this study was to document normal responses of the NDTSUR in asymptomatic participants. The secondary aim was to investigate potential gender and leg dominance influences. DESIGN: A cross-sectional study was designed. METHODS: NDTSUR was performed on 44 asymptomatic participants with a total of 88 lower limbs. The range of motion at the point of first appearance of symptoms (S1) and the point of pain tolerance (S2), quality and distribution of sensory responses were recorded. RESULTS: Hip flexion was significantly greater (p < 0.001) at S2 (63.6 ± 13.1°) than S1 (42.5 ± 12°) and the mean difference was 21.8° (95% CI: 21.8; 22.8) (p < 0.001). However, hip flexion was not different between gender nor dominance (p > 0.05). The descriptor of the quality of the sensory responses more often used by participants was stretching (87% and 76% for S1 and S2, respectively) in the posterior knee and lateral leg. CONCLUSIONS: This study describes the sensory responses of asymptomatic participants resulting from the NDTSUR. The findings indicate that NDTSUR responses are independent of the influence of gender or leg dominance.


Asunto(s)
Movimiento , Estudios Transversales , Humanos , Examen Neurológico , Rango del Movimiento Articular , Valores de Referencia
9.
Musculoskelet Sci Pract ; 43: 117-121, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31272895

RESUMEN

BACKGROUND: Neurodynamic tests (NDTs) have shown to be useful in evaluating neural tissue involvement. Peroneal nerve reaches high importance in ankle injuries. However, up to date, no study has documented the normal responses for this nerve. OBJECTIVES: The objective of this study was to document normal responses of the peroneal neurodynamic test (NDTPER) in asymptomatic subjects. Differences in sensory response depending on sex and leg dominance were also examined. DESIGN: A cross-sectional study was designed. METHOD: Forty-four asymptomatic subjects with a total of 88 lower limbs were tested. The range of motion (ROM) at the point of first appearance of symptoms (S1) and the point of symptoms tolerance (S2), quality and distribution of sensory responses were recorded. RESULTS: Hip flexion was significantly higher at S2 than S1 (mean difference, 27.22°; 95% CI: 25.29°, 29.14°; p < 0.001). However, it was not different between sex, nor dominance (p > 0.05). The descriptor of the quality of sensory responses more often used by subjects was stretching (90.9%) in the external foot (74.6%). CONCLUSIONS: This study provides the normal hip flexion angle and quality and distribution of sensory responses to the NDTPER in asymptomatic subjects. Responses were independent of the influence of sex or leg dominance.


Asunto(s)
Examen Neurológico/métodos , Nervio Peroneo/fisiología , Adulto , Estudios Transversales , Femenino , Humanos , Masculino , Rango del Movimiento Articular , Valores de Referencia , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...