Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
J Endovasc Ther ; : 15266028231157639, 2023 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-36896884

RESUMEN

PURPOSE: To gain insight into safety and efficacy of in situ and ex-situ fenestration techniques for total endovascular arch repair. The term ex-situ fenestration is referring to physician-modified stent-graft technique where fenestration is performed on a back table. METHODS: Electronic search was conducted according to PRISMA (Preferred Reporting Items for Systematic review and Meta-analyses) guidelines from 2000 to 2020. The main outcomes measured were 30-day mortality, stroke, aortic-related mortality, and reintervention rates. RESULTS: Fifteen studies were eligible: 7 ex-situ fenestration (189 patients) and 8 in-situ fenestration (149 patients). In ex-situ group, dissection was the main pathology treated and proximal sealing zones were Z0 or 1 in 53.5% of patients. In in-situ group, dissection and aneurysm were equally represented in around 40% of cases and proximal sealing zones were Z0 or 1 in 46.5% of patients. Cumulative 30-day all-cause mortality was similar in both groups: 3.8% (95% confidence interval [CI]: 1.7%-8.2%) and 3.8% (95% CI: 1.6%-8.9%), respectively, in ex-situ and in-situ groups and stroke rate of 2.8% (95% CI: 1.1%-7%) and 5.3% (95% CI: 2.6%-10.5%). After a 11.1 ± 2.6 months mean follow-up for ex-situ and 16.7 ± 2.3 months for in-situ group, there were 5.2 and 1.4 reinterventions per 100 patients-years, respectively, for ex-situ and in situ groups. Aortic-related mortality rates of, respectively, 3.2% (95% CI: 1.3%-7.4%) and 2.6% (95% CI: 0.9%-7.3%) were noted in ex-situ and in situ groups. CONCLUSION: The reported data show favorable short-term results of both ex-situ and in-situ fenestration techniques with low mortality and strokes rates. However, durability is still questionable given the lack of long-term data. Both options may have their place in arch repair beyond the spectrum of emergent and urgent cases, on condition that results stand the test of time. CLINICAL IMPACT: In situ and ex-situ fenestration techniques have been initially developed to overcome emergency or as a bail out techniques however giving the promessing favorable short term results indications of these techniques may be extended to elective patients ineligible to customized stent-grafts and possibly in the futur to more elective cases as an option for total endovascular arch repair.

2.
Ann Vasc Surg ; 93: 149-156, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36906127

RESUMEN

BACKGROUND: Infrainguinal vascular injuries (IIVIs) are emergencies involving both functional and vital prognosis. The choice between saving the limb or doing a first-line amputation is difficult even for an experienced surgeon. The aims of this work are to analyze early outcomes in our center and to identify predictive factors for amputation. METHODS: Between 2010 and 2017, we reviewed retrospectively patients with IIVI. The main criteria for judgment were as follows: primary, secondary, and overall amputation. Two groups of potential risk factors of amputation were analyzed: Those related to the patient: age, shock, ISS score and those related to the lesion: mechanism, above or below the knee, bone lesions, venous lesions and skin decay. A univariate and multivariate analysis were performed to determine the risk factor(s) independently associated with the occurrence of amputation. RESULTS: Fifty-seven IIVIs were found in 54 patients. The mean ISS was 32,3 ± 21. A primary amputation was performed in 19%, and secondary in 14% of cases. Overall amputation rate was 35% (n = 19). Multivariate analysis reveals that the ISS is the only predictor of primary (P = 0.009; odds ratio (OR):1.07; confidence interval (CI):1.01-1.12) and global (P = 0.04; OR:1.07; IC:1.02-1.13) amputation. A threshold value of 41 was selected as a primary amputation risk factor with a negative predictive value of 97%. CONCLUSIONS: The ISS is a good predictor of the risk of amputation in IIVI. A threshold of 41 is an objective criterion helping to decide for a first-line amputation. Advanced age and hemodynamic instability should not be important in the decision tree.


Asunto(s)
Lesiones del Sistema Vascular , Humanos , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Pronóstico , Factores de Riesgo , Amputación Quirúrgica , Recuperación del Miembro
4.
J Vasc Surg ; 74(2): 681-682, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34303482
5.
J Vasc Surg ; 74(1): 346-347, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34172197
6.
J Vasc Surg ; 73(4): 1445-1455, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33098944

RESUMEN

BACKGROUND: Encouraging recent reports on endovascular treatment of common femoral artery (CFA) atherosclerotic disease has rendered the question regarding the place of this technique evermore pertinent and legitimizes the performance of randomized trials. The present comprehensive review focused on the early and midterm outcomes to help assess the benefit/risk balance of endovascular vs open repair for CFA treatment. METHODS: Embase and Medline searches were conducted according to the PRISMA (Preferred Reporting Items for Systematic review and Meta-Analyses) standards to identify studies from 2000 to 2018 reporting on endovascular repair (ER), open surgery (OS), and comparisons of both techniques for CFA atherosclerosis treatment. The outcomes measured were 30-day mortality, morbidity, reintervention rates, midterm patency, late reintervention, and restenosis rates. RESULTS: Twenty-eight studies were eligible: 14 OS (1920 patients), 12 ER (1900 patients), and 2 comparative randomized trials (197 patients). The meta-analysis of the comparative studies revealed no differences in 30-day mortality or reintervention rates but improved 30-day morbidity after ER. At 1 year, the primary patency rates did not differ between ER and OS, nor did the late reintervention rate. In the noncomparative studies, with a mean follow-up period of 23.8 months for ER and 66 months for OS, the restenosis rate was 14.4% and 4.7%, respectively. The reported stent fracture rate was 3.6%. In the ER cohort, the overall primary patency at 1, 2, and 3 years was 81.9%, 77.8%, and 75.1%, respectively. For the OS cohort, the overall primary patency rate at 1, 2, and 3 years was 93.4%, 91.4%, and 90.5%, respectively. CONCLUSIONS: Despite expectations, our analysis of the reported data suggests that the perioperative mortality is not in favor of ER; however, the perioperative morbidity showed an advantage for ER compared with OS. Also, although comparable in the first year, the long-term primary patency rate was much greater after OS. At present, the place of ER for CFA treatment still requires further definition. Additional clarification of the indications and more research are both required to determine the optimal endovascular technology and femoral bifurcation reconstruction with stenting.


Asunto(s)
Procedimientos Endovasculares , Arteria Femoral/cirugía , Enfermedad Arterial Periférica/terapia , Procedimientos Quirúrgicos Vasculares , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Arteria Femoral/fisiopatología , Humanos , Enfermedad Arterial Periférica/mortalidad , Enfermedad Arterial Periférica/fisiopatología , Enfermedad Arterial Periférica/cirugía , Recurrencia , Retratamiento , Medición de Riesgo , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular , Procedimientos Quirúrgicos Vasculares/efectos adversos , Procedimientos Quirúrgicos Vasculares/mortalidad
8.
J Biomech ; 94: 138-146, 2019 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-31400813

RESUMEN

Mechanical characteristics of both the healthy ascending aorta and acute type A aortic dissection were investigated using in vitro biaxial tensile tests, in vivo measurements via transoesophageal echocardiography and histological characterisations. This combination of analysis at tissular, structural and microstructural levels highlighted the following: (i) a linear mechanical response for the dissected intimomedial flap and, conversely, nonlinear behaviour for both healthy and dissected ascending aorta; all showed anisotropy; (ii) a stiffer mechanical response in the longitudinal than in the circumferential direction for the healthy ascending aorta, consistent with the histological quantification of collagen and elastin fibre density; (iii) a link between dissection and ascending aorta stiffening, as revealed by biaxial tensile tests. This result was corroborated by in vivo measurements with stiffness index, ß, and Peterson modulus, Ep, higher for patients with dissection than for control patients. It was consistent with histological analysis on dissected samples showing elastin fibre dislocations, reduced elastin density and increased collagen density. To our knowledge, this is the first study to report biaxial tensile tests on the dissected intimomedial flap and in vivo stiffness measurements of acute type A dissection in humans.


Asunto(s)
Aorta/fisiología , Aneurisma de la Aorta/fisiopatología , Disección Aórtica/fisiopatología , Anciano , Disección Aórtica/patología , Anisotropía , Aorta/anatomía & histología , Aneurisma de la Aorta/patología , Fenómenos Biomecánicos , Colágeno , Ecocardiografía Transesofágica , Elastina , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estrés Mecánico , Resistencia a la Tracción
10.
Ann Thorac Surg ; 107(5): 1559-1570, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30481516

RESUMEN

BACKGROUND: The respective place of endovascular repair (ER) versus open surgery (OS) in thoracic dissecting aneurysm treatment remains debatable. This comprehensive review seeks to compare the outcomes of ER versus OS in chronic type B aortic dissection treatment. METHODS: Embase and Medline searches (2000 to 2017) were performed following PRISMA (Preferred Reporting Items for Systematic Review and Meta-Analyses) guidelines. Outcomes data extracted comprised (1) early mortality and major complications: stroke, spinal cord ischemia (SCI), dialysis, and respiratory complications; and (2) late survival and reinterventions. Reintervention causes were divided into proximal, adjacent, and distal. Comparative studies allowed comparative meta-analysis. Noncomparative studies were analyzed in pooled proportion meta-analyses for each group. RESULTS: A total of 39 studies were identified after exclusions, of which 4 were comparative. Comparative meta-analysis demonstrated lower early mortality for ER (odds ratio [OR], 4.13; 95% confidence interval [CI], 1.10 to 15.4), stroke (OR, 4.33; 95% CI, 1.02 to 18.35), SCI (OR, 3.3; 95% CI, 0.97 to 11.25), and respiratory complications (OR, 6.88; 95% CI,1.52 to 31.02), but higher reintervention rate (OR, 0.34; 95% CI, 0.16 to 0.69). Midterm survival was similar (OR, 1.19; 95% CI, 0.42 to 3.32). Noncomparative studies demonstrated that most reinterventions were related to the aortic segment distal to primary intervention in both groups (OS 73%, ER 59%). Reintervention procedures were mainly surgical for OS (85%), mainly endovascular for ER (75%). Rupture rates were 1.2% (OS) and 3% (ER). CONCLUSIONS: Endovascular repair is associated with significant early benefits, but this is not sustained at midterm. Reintervention is more frequent, but the OS is not exempt from reintervention or late rupture. Both techniques have their place, but patient selection is key.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Enfermedad Crónica , Humanos , Resultado del Tratamiento
11.
J Surg Res ; 225: 21-28, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29605031

RESUMEN

BACKGROUND: Animal modeling is a prerequisite for clinical transfer of new therapies. This study targets an acute in vivo animal model of type A dissection using endovascular approach with a view to test future stent grafts dedicated to this aortic segment. METHODS: Experiments were conducted on 13 swine. Two arterial accesses, femoral and percutaneous transapical, were required. Entry tear was created by endovascular instrumental means inserted through transapical access with either Outback catheter (group 1, n = 3) or EchoTip Endoscopic Ultrasound Needle (group 2, n = 10). Afterward, dissection extension was obtained in antegrade direction by looped guidewire technique, and, as often as possible, re-entry tear was created with either looped guidewire or Outback catheter. Finally, entry tear, dissected space, and re-entry tear when existing were dilated with 8-mm balloon. In our acute model, animals were euthanized at the end of the experiment day, and aortas were explanted for macroscopic and histologic examination. RESULTS: The model was successfully created in 10 out of 13 animals. In group 1, dissection was limited to arch with 23 mm average length and no possibility of achieving re-entry tear. One aortic perforation was observed. In group 2, dissection was extended up to descending thoracic or thoracoabdominal aorta, with 110 mm average length (range 40-165 mm), and re-entry tear was created in seven cases. Histologic examination confirmed the presence of intimo-medial flap. CONCLUSIONS: The present experiment validates a new type A dissection animal model, which morphologically reproduces human aortic dissection features. As such, it provides an advantageous basis for testing future stent grafts.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Disección Aórtica/cirugía , Modelos Animales de Enfermedad , Procedimientos Endovasculares/métodos , Enfermedad Aguda , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/etiología , Animales , Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Ecocardiografía , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Stents , Porcinos
12.
Eur J Vasc Endovasc Surg ; 55(4): 492-502, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29307756

RESUMEN

OBJECTIVE/BACKGROUND: Increasingly, reports show that compliance rates with endovascular aneurysm repair (EVAR) surveillance are often suboptimal. The aim of this study was to determine the safety implications of non-compliance with surveillance. METHODS: The study was carried out according to the Preferred Items for Reporting of Systematic Reviews and Meta-Analyses (PRISMA) guidelines. An electronic search was undertaken by two independent authors using Embase, MEDLINE, Cochrane, and Web of Science databases from 1990 to July 2017. Only studies that analysed infrarenal EVAR and had a definition of non-compliance described as weeks or months without imaging surveillance were analysed. Meta-analysis was carried out using the random-effects model and restricted maximum likelihood estimation. RESULTS: Thirteen articles (40,730 patients) were eligible for systematic review; of these, seven studies (14,311 patients) were appropriate for comparative meta-analyses of mortality rates. Three studies (8316 patients) were eligible for the comparative meta-analyses of re-intervention rates after EVAR and four studies (12,995 patients) eligible for meta-analysis for abdominal aortic aneurysm related mortality (ARM). The estimated average non-compliance rate was 42.0% (95% confidence interval [CI] 28-56%). Although there is some evidence that non-compliant patients have better survival rates, there was no statistically significant difference in all cause mortality rates (year 1: odds ratio [OR] 5.77, 95% CI 0.74-45.14; year 3: OR 2.28, 95% CI 0.92-5.66; year 5: OR 1.81, 95% CI 0.88-3.74) and ARM (OR 1.47, 95% CI 0.99-2.19) between compliant and non-compliant patients in the first 5 years after EVAR. The re-intervention rate was statistically significantly higher in compliant patients from 3 to 5 years after EVAR (year 1: OR 6.36, 95% CI 0.23-172.73; year 3: OR 3.94, 85% CI 1.46-10.69; year 5: OR 5.34, 95% CI 1.87-15.29). CONCLUSION: This systematic review and meta-analysis suggests that patients compliant with EVAR surveillance programmes may have an increased re-intervention rate but do not appear to have better survival rates than non-compliant patients.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Cooperación del Paciente , Complicaciones Posoperatorias/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Humanos , Estimación de Kaplan-Meier , Oportunidad Relativa , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Valor Predictivo de las Pruebas , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
13.
Ann Vasc Surg ; 48: 141-150, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29225128

RESUMEN

BACKGROUND: Technical and clinical success of thoracic aortic endovascular procedures relies mainly on the choice of the proximal sealing zone (PSZ). The latter can be affected by multiple complications, all of them having a potential gravity and a direct link with the quality of the PSZ. The objective of this study was to analyze the risk factors of PSZ complications occurrence. METHODS: Between 2007 and 2015, all the patients treated by a thoracic stent graft in zones 2, 3, or 4 were retrospectively reviewed, with analysis of the preoperative and postoperative angio-computed tomography. Proximal sealing zone complications are type Ia endoleaks, bird beak ≥20 mm, malposition ≥11 mm, migration ≥10 mm, and retrograde dissection. Three types of potential risk factors were analyzed: (1) related to the patients (age, gender, pathology, urgency, hybrid surgery); (2) related to the stent graft (bare or covered proximal stent, degree of oversizing, number of stents, generation); (3) related to the morphology (radius of curvature, diameter, degree of conicity, calcifications and thrombus of the neck, depth of the arch, angulation of the proximal sealing zone, and tortuosity index of the arch and the thoracic aorta. RESULTS: Seventy-six patients (mean age: 54 years, 17-93 years) were treated for traumatic aortic rupture (n = 27, 35.5%), aortic dissection (n = 26, 34%), aneurysm (n = 15, 20%), and other diseases (floating thrombus, aortoesophageal fistula) (n = 8, 10.5%). A hybrid surgery was carried out in 18 patients (24%). Primary technical success was 93.5% (n = 71). With a mean follow-up of 29 months, 30 PSZ complications were observed in 21 patients (28%): type Ia endoleaks (n = 3, 4%), bird beak (n = 7, 9%), malposition (n = 3, 4%), migration (n = 1, 1.5%), retrograde dissection (n = 1, 1.5%), or several complications (n = 6, 7.8%). Among the morphological factors, 2 parameters were significantly associated with the occurrence of complications: tortuosity index (group without PSZ complications 1.62 ± 0.2 vs. group with PSZ complications 1.72 ± 0.2, P = 0.042), and the diameter of the proximal neck (group without PSZ complications 25.7 ± 5 vs. group with PSZ complications 31 ± 6.0, P = 0.001). Neither the demographic factors nor those related to the stent graft presented a statistically significant relation with the occurrence of complications. CONCLUSIONS: This work clearly highlights the relation between PSZ complications, independently of their type, and the local and global aortic morphology. A wide proximal neck, > 34 mm, and an important aortic tortuosity, > 1.8, are situations at risk.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Disección Aórtica/diagnóstico por imagen , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/lesiones , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Rotura de la Aorta/diagnóstico por imagen , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Angiografía por Tomografía Computarizada , Endofuga/etiología , Procedimientos Endovasculares/instrumentación , Femenino , Migración de Cuerpo Extraño/etiología , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
14.
Circ Res ; 122(4): 616-623, 2018 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-29242238

RESUMEN

RATIONALE: Short telomere length (TL) in leukocytes is associated with atherosclerotic cardiovascular disease (ASCVD). It is unknown whether this relationship stems from having inherently short leukocyte TL (LTL) at birth or a faster LTL attrition thereafter. LTL represents TL in the highly proliferative hematopoietic system, whereas TL in skeletal muscle represents a minimally replicative tissue. OBJECTIVE: We measured LTL and muscle TL (MTL) in the same individuals with a view to obtain comparative metrics for lifelong LTL attrition and learn about the temporal association of LTL with ASCVD. METHODS AND RESULTS: Our Discovery Cohort comprised 259 individuals aged 63±14 years (mean±SD), undergoing surgery with (n=131) or without (n=128) clinical manifestation of ASCVD. In all subjects, MTL adjusted for muscle biopsy site (MTLA) was longer than LTL and the LTL-MTLA gap similarly widened with age in ASCVD patients and controls. Age- and sex-adjusted LTL (P=0.005), but not MTLA (P=0.90), was shorter in patients with ASCVD than controls. The TL gap between leukocytes and muscle (LTL-MTLA) was wider (P=0.0003), and the TL ratio between leukocytes and muscle (LTL/MTLA) was smaller (P=0.0001) in ASCVD than in controls. Findings were replicated in a cohort comprising 143 individuals. CONCLUSIONS: This first study to apply the blood-and-muscle TL model shows more pronounced LTL attrition in ASCVD patients than controls. The difference in LTL attrition was not associated with age during adulthood suggesting that increased attrition in early life is more likely to be a major explanation of the shorter LTL in ASCVD patients. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02176941.


Asunto(s)
Aterosclerosis/genética , Acortamiento del Telómero , Anciano , Aterosclerosis/patología , Femenino , Humanos , Leucocitos/metabolismo , Masculino , Persona de Mediana Edad , Fibras Musculares Esqueléticas/metabolismo
15.
J Cardiovasc Surg (Torino) ; 58(6): 818-827, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28920634

RESUMEN

BACKGROUND: This study aimed to identify patient, pathology and procedure-related factors affecting perioperative and mid-term mortality of thoracic aorta emergencies. METHODS: Between 2007 and 2014, patients treated emergently with thoracic stent-graft were retrospectively reviewed. Variables analyzed were: age, renal insufficiency, shock, cardiac arrest, transfer status, pathology, debranching procedures, operation duration, vascular access and European System for Cardiac Operative Risk Evaluation (EuroSCORE). Seventy-four patients (54.5±22 years) were treated for traumatic rupture (N.=31), aneurysm (TAA) (N.=16), acute aortic syndrome (N.=18), aorto-esophageal fistula (N.=2), floating thrombus (N.=7). Thirty-four patients (46%) were in shock, including 3 suffering preoperative cardiac arrest. Proximal landing zones were: zone 0 (N.=4), zone 1 (N.=4), zone 2 (N.=37), zone 3 (N.=21) and zone 4 (N.=8). Debranching procedures were performed in 16 cases (22%). RESULTS: Perioperative all-cause- mortality was 18.9% (N.=14). Univariable analysis identified age, renal insufficiency, shock, transfer status, cardiac arrest, debranching procedures in zones 0 or 4 and EuroSCORE as predictors of death (P=0.002, P=0.001, P=0.002, P=0.05, P=0.006, P=0.028, P<0.001 respectively). Multivariable analysis pinpointed shock and renal insufficiency as independent risk factors. Over a mean 41 months follow-up, survival was 72% at both 1 and 3 years and was impacted by pathology and debranching procedures. Aortic re-intervention rate was 12% (N.=9), significantly higher in TAA group (P=0.004). CONCLUSIONS: Hemorrhagic shock remains highly lethal for endovascular repair. Hybrid procedures in zones 0 or 4 should be avoided to improve short and mid-term outcomes. TAA groups require close surveillance to detect late events.


Asunto(s)
Aorta Torácica/cirugía , Enfermedades de la Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Aorta Torácica/efectos de los fármacos , Enfermedades de la Aorta/complicaciones , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Distribución de Chi-Cuadrado , Urgencias Médicas , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Francia , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , Choque Hemorrágico/etiología , Choque Hemorrágico/mortalidad , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
16.
Ann Thorac Surg ; 103(6): 1992-2004, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28434549

RESUMEN

This review analyzed the incidence, mechanisms, and risk factors of aortic-related reintervention after endovascular repair of chronic dissections. The systematic review identified 28 studies describing 1,249 patients at median 27 months follow-up (range, 10.3 to 64.4). There were six reinterventions, 0.7 ruptures, and 1.2 surgical conversions per 100 patient-years of follow-up. Stent-related reinterventions were more frequent than nonstent related (80.2% vs 19.8%). Distal false lumen perfusion was the most common complication (40.5%). No individual risk factor-treatment timing, disease extent, covered aorta length, or remodelling-was associated with reintervention. Further investigation based on consistent reporting standards is required.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Procedimientos Endovasculares , Reoperación , Aorta/cirugía , Femenino , Humanos , Masculino , Factores de Riesgo , Stents , Procedimientos Quirúrgicos Torácicos
18.
J Biomech ; 49(10): 2031-2037, 2016 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-27211783

RESUMEN

One of the aims of this work is to develop an original custom built biaxial set-up to assess mechanical behavior of soft tissues. Stretch controlled biaxial tensile tests are performed and stereoscopic digital image correlation (SDIC) is implemented to measure the 3D components of the generated displacements. Using this experimental device, the main goal is to investigate the mechanical behavior of porcine ascending aorta in the more general context of human ascending aorta pathologies. The results highlight that (i) SDIC arrangement allows accurate assessment of displacements and so stress strain curves, (ii) porcine ascending aorta has a nearly linear and anisotropic mechanical behavior until 30% of strain, (iii) porcine ascending aorta is stiffer in the circumferential direction than in the longitudinal one, (iv) the material coefficient representing the interaction between the two loading directions is thickness dependent, (v) taking into account the variability of the samples the stress values are independent of the stretch rate in the range of values from 10(-3) to 10(-1)s(-1) and finally, (vi) unlike other segments of the aorta, 4-month-old pigs ascending aorta is definitely not a relevant model to investigate the mechanical behavior of the human ascending aorta.


Asunto(s)
Aorta/fisiología , Animales , Anisotropía , Fenómenos Biomecánicos , Estrés Mecánico , Porcinos , Resistencia a la Tracción
19.
Intensive Care Med ; 41(4): 667-76, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25731634

RESUMEN

BACKGROUND: In the intensive care unit (ICU), the outcomes of patients with acute mesenteric ischemia (AMI) are poorly documented. This study aimed to determine the risk factors for death in ICU patients with AMI. METHODS: A retrospective, observational, non-interventional, multicenter study was conducted in 43 ICUs of 38 public institutions in France. From January 2008 to December 2013, all adult patients with a diagnosis of AMI during their hospitalization in ICU were included in a database. The diagnosis was confirmed by at least one of three procedures (computed tomography scan, gastrointestinal endoscopy, or upon surgery). To determine factors associated with ICU death, we established a logistic regression model. Recursive partitioning analysis was applied to construct a decision tree regarding risk factors and their interactions most critical to determining outcomes. RESULTS: The death rate of the 780 included patients was 58 %. Being older, having a higher sequential organ failure assessment (SOFA) severity score at diagnosis, and a plasma lactate concentration over 2.7 mmol/l at diagnosis were independent risk factors of ICU mortality. In contrast, having a prior history of peripheral vascular disease or an initial surgical treatment were independent protective factors against ICU mortality. Using age and SOFA severity score, we established an ICU mortality score at diagnosis based on the cutoffs provided by recursive partitioning analysis. Probability of survival was statistically different (p < 0.001) between patients with a score from 0 to 2 and those with a score of 3 and 4. CONCLUSION: Acute mesenteric ischemia in ICU patients was associated with a 58 % ICU death rate. Age and SOFA severity score at diagnosis were risk factors for mortality. Plasma lactate concentration over 2.7 mmol/l was also an independent risk factor, but values in the normal range did not exclude the diagnosis of AMI.


Asunto(s)
Unidades de Cuidados Intensivos , Isquemia Mesentérica/mortalidad , Factores de Edad , Anciano , Anciano de 80 o más Años , Femenino , Francia , Mortalidad Hospitalaria , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Insuficiencia Multiorgánica/mortalidad , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...