Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-36751306

RESUMEN

Optical coherence tomography (OCT) is a non-contact method for imaging the topological and internal microstructure of samples in three dimensions. OCT can be configured as a conventional microscope, as an ophthalmic scanner, or using endoscopes and small diameter catheters for accessing internal biological organs. In this Primer, we describe the principles underpinning the different instrument configurations that are tailored to distinct imaging applications and explain the origin of signal, based on light scattering and propagation. Although OCT has been used for imaging inanimate objects, we focus our discussion on biological and medical imaging. We examine the signal processing methods and algorithms that make OCT exquisitely sensitive to reflections as weak as just a few photons and that reveal functional information in addition to structure. Image processing, display and interpretation, which are all critical for effective biomedical imaging, are discussed in the context of specific applications. Finally, we consider image artifacts and limitations that commonly arise and reflect on future advances and opportunities.

2.
Opt Lett ; 45(10): 2748-2751, 2020 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-32412457

RESUMEN

Advanced signal reconstruction in polarization-sensitive optical coherence tomography (OCT) frequently relies on an accurate determination of the signal noise floor. However, current methods for evaluating the noise floor are often impractical and subjective. Here we present a method using the degree of polarization uniformity and known speckle intensity statistics to model and estimate the OCT noise floor automatically. We establish the working principle of our method with a series of phantom experiments and demonstrate the robustness of our noise estimation method across different imaging systems and applications in vivo.


Asunto(s)
Relación Señal-Ruido , Tomografía de Coherencia Óptica/métodos , Automatización , Fantasmas de Imagen
3.
Biomed Opt Express ; 3(8): 1947-54, 2012 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-22876357

RESUMEN

Transbronchial needle aspiration (TBNA) is a procedure routinely performed to diagnose peripheral pulmonary lesions. However, TBNA is associated with a low diagnostic yield due to inappropriate needle placement. We have developed a flexible transbronchial optical frequency domain imaging (TB-OFDI) catheter that functions as a "smart needle" to confirm the needle placement within the target lesion prior to biopsy. The TB-OFDI smart needle consists of a flexible and removable OFDI catheter (430 µm dia.) that operates within a standard 21-gauge TBNA needle. The OFDI imaging core is based on an angle polished ball lens design with a working distance of 160 µm from the catheter sheath and a spot size of 25 µm. To demonstrate the potential of the TB-OFDI smart needle for transbronchial imaging, an inflated excised swine lung was imaged through a standard bronchoscope. Cross-sectional and longitudinal OFDI results reveal the detailed network of alveoli in the lung parenchyma suggesting that the TB-OFDI smart needle may be a useful tool for guiding biopsy acquisition to increase the diagnostic yield.

4.
J Microsc ; 239(2): 87-91, 2010 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-20629914

RESUMEN

Spectrally encoded confocal microscopy and optical frequency domain imaging are two non-contact optical imaging technologies that provide images of tissue cellular and architectural morphology, which are both used for histopathological diagnosis. Although spectrally encoded confocal microscopy has better transverse resolution than optical frequency domain imaging, optical frequency domain imaging can penetrate deeper into tissues, which potentially enables the visualization of different morphologic features. We have developed a co-registered spectrally encoded confocal microscopy and optical frequency domain imaging system and have obtained preliminary images from human oesophageal biopsy samples to compare the capabilities of these imaging techniques for diagnosing oesophageal pathology.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Microscopía Confocal/métodos , Patología/métodos , Tomografía de Coherencia Óptica/métodos , Enfermedades del Esófago/diagnóstico , Esófago/patología , Humanos
5.
Opt Express ; 18(11): 11418-27, 2010 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-20589002

RESUMEN

A novel heterodyne Doppler interferometer method for compensating motion artifacts caused by cardiac motion in intracoronary optical frequency domain imaging (OFDI) is demonstrated. To track the relative motion of a catheter with regard to the vessel, a motion tracking system is incorporated with a standard OFDI system by using wavelength division multiplexing (WDM) techniques. Without affecting the imaging beam, dual WDM monochromatic beams are utilized for tracking the relative radial and longitudinal velocities of a catheter-based fiber probe. Our results demonstrate that tracking instantaneous velocity can be used to compensate for distortion in the images due to motion artifacts, thus leading to accurate reconstruction and volumetric measurements with catheter-based imaging.


Asunto(s)
Artefactos , Angiografía Coronaria/instrumentación , Endoscopios , Aumento de la Imagen/instrumentación , Interferometría/instrumentación , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Movimiento (Física) , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
J Voice ; 23(3): 269-76, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-18346865

RESUMEN

Understanding pediatric voice development and laryngeal pathology is predicated on a detailed knowledge of the microanatomy of the layered structure of the vocal fold. Our current knowledge of this microanatomy and its temporal evolution is limited by the lack of pediatric specimen availability. By providing the capability to image pediatric vocal folds in vivo, a noninvasive microscopy technique could greatly expand the existing database of pediatric laryngeal microanatomy and could furthermore make longitudinal studies possible. A variety of natural-contrast optical imaging technologies, including optical frequency domain imaging (OFDI), full-field optical coherence microscopy (FF-OCM), and spectrally encoded confocal microscopy (SECM) have been recently developed for noninvasive diagnosis in adult patients. In this paper, we demonstrate the potential of these three techniques for laryngeal investigation by obtaining images of excised porcine vocal fold samples. In our study, OFDI allowed visualization of the vocal fold architecture deep within the tissue, from the superficial mucosa to the vocalis muscle. The micron-level resolution of SECM allowed investigation of cells and extracellular matrix fibrils from the superficial mucosa to the intermediate layer of the lamina propria (LP) (350 microm penetration depth). The large field of view (up to 700 microm), penetration depth (up to 500 microm), and resolution (2x2x1microm [XxYxZ]) of FF-OCM enabled comprehensive three-dimensional evaluation of the layered structure of the LP. Our results suggest that these techniques provide important and complementary cellular and structural information, which may be useful for investigating pediatric vocal fold maturation in vivo.


Asunto(s)
Pliegues Vocales/crecimiento & desarrollo , Animales , Matriz Extracelular , Interpretación de Imagen Asistida por Computador , Músculos Laríngeos/anatomía & histología , Músculos Laríngeos/crecimiento & desarrollo , Microscopía Confocal , Membrana Mucosa/anatomía & histología , Membrana Mucosa/crecimiento & desarrollo , Porcinos , Tomografía de Coherencia Óptica , Pliegues Vocales/anatomía & histología
7.
Opt Express ; 16(19): 14836-44, 2008 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-18795020

RESUMEN

The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique that utilizes a single optical fiber and miniature diffractive optics to obtain endoscopic images through small diameter probes. Using spectral-domain interferometry, SEE is furthermore capable of three-dimensional volume imaging at video rates. Here we show that by measuring relative spectral phases, this technology can additionally measure Doppler shifts. Doppler SEE is demonstrated in flowing Intralipid phantoms and vibrating middle ear ossicles.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Endoscopios , Tecnología de Fibra Óptica/instrumentación , Imagenología Tridimensional/instrumentación , Interferometría/instrumentación , Flujometría por Láser-Doppler/instrumentación , Refractometría/instrumentación , Humanos , Miniaturización , Fibras Ópticas , Fantasmas de Imagen
8.
Opt Lett ; 33(12): 1330-2, 2008 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-18552948

RESUMEN

We demonstrate a novel high-speed polarization-sensitive optical frequency domain imaging system employing high-speed polarization modulation. Rapid and continuous polarization modulation of light prior to illumination of the sample is accomplished by shifting the frequency of one polarization eigenstate by an amount equal to one quarter of the digitization sampling frequency. This approach enables polarization-sensitive imaging with a single detection channel and overcomes artifacts that may arise from temporal variations of the birefringence in fiber-optic imaging probes and spatial variation of birefringence in the sample.


Asunto(s)
Óptica y Fotónica , Animales , Pollos , Vasos Coronarios/ultraestructura , Microscopía de Polarización/métodos , Músculo Esquelético/ultraestructura , Porcinos
9.
Opt Express ; 16(2): 1096-103, 2008 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-18542183

RESUMEN

Polarization sensitive optical coherence tomography (PS-OCT) provides a cross-sectional image of birefringence in biological samples that is complementary in many applications to the standard reflectance-based image. Recent ex vivo studies have demonstrated that birefringence mapping enables the characterization of collagen and smooth muscle concentration and distribution in vascular tissues. Instruments capable of applying these measurements percutaneously in vivo may provide new insights into coronary atherosclerosis and acute myocardial infarction. We have developed a polarization sensitive optical frequency domain imaging (PS-OFDI) system that enables high-speed intravascular birefringence imaging through a fiber-optic catheter. The novel design of this system utilizes frequency multiplexing to simultaneously measure reflectance of two incident polarization states, overcoming concerns regarding temporal variations of the catheter fiber birefringence and spatial variations in the birefringence of the sample. We demonstrate circular cross-sectional birefringence imaging of a human coronary artery ex vivo through a flexible fiber-optic catheter with an A-line rate of 62 kHz and a ranging depth of 6.2 mm.


Asunto(s)
Vasos Coronarios/ultraestructura , Tecnología de Fibra Óptica/instrumentación , Aumento de la Imagen/instrumentación , Microscopía de Polarización/instrumentación , Tomografía de Coherencia Óptica/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Tecnología de Fibra Óptica/métodos , Humanos , Aumento de la Imagen/métodos , Microscopía de Polarización/métodos , Fibras Ópticas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía de Coherencia Óptica/métodos
10.
Opt Express ; 16(3): 1748-57, 2008 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-18542254

RESUMEN

Endoscopic imaging below tissue surfaces and through turbid media may provide improved diagnostic capabilities and visibility in surgical settings. Spectrally encoded endoscopy (SEE) is a recently developed method that utilizes a single optical fiber, miniature optics and a diffractive grating for high-speed imaging through small diameter, flexible endoscopic probes. SEE has also been shown to provide three-dimensional topological imaging capabilities. In this paper, we have configured SEE to additionally image beneath tissue surfaces, by increasing the system's sensitivity and acquiring the complex spectral density for each spectrally resolved point on the sample. In order to demonstrate the capability of SEE to obtain subsurface information, we have utilized the system to image a resolution target through intralipid solution, and conduct volumetric imaging of a mouse embryo and excised human middle-ear ossicles. Our results demonstrate that real-time subsurface imaging is possible with this miniature endoscopy technique.


Asunto(s)
Compresión de Datos/métodos , Endoscopios , Aumento de la Imagen/instrumentación , Imagenología Tridimensional/instrumentación , Microscopía/instrumentación , Análisis Espectral/instrumentación , Tomografía Óptica/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad
11.
Opt Lett ; 32(19): 2768-70, 2007 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-17909567

RESUMEN

A technique for increasing the ranging depth in optical frequency domain imaging utilizing frequency encoding is presented. Ranging depth is enhanced by using two interferometer reference arms with different path lengths and independent modulation frequencies (25 and 50 MHz). With this configuration, the sensitivity decreases by 6 dB over a depth range of 7 mm, approximately a threefold improvement over the conventional optical frequency domain imaging technique. We demonstrate that the reference arm frequency separation, tuning speed, center wavelength, and instantaneous coherence length determine the signal-to-cross-talk ratio.


Asunto(s)
Algoritmos , Compresión de Datos/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Señales Asistido por Computador , Tomografía de Coherencia Óptica/métodos , Análisis de Fourier , Sensibilidad y Especificidad
12.
Opt Lett ; 32(11): 1560-2, 2007 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-17546188

RESUMEN

Noninvasive measurements of the scattering coefficients of optically turbid media using angle-resolved optical frequency-domain imaging (OFDI) are demonstrated. It is shown that, by incoherently averaging OFDI reflectance signals acquired at different backscattering angles, speckle noise is reduced, allowing scattering coefficients to be extracted from a single A-line with much higher accuracy than with measurements from conventional OFDI and optical coherence tomography systems. Modeling speckle as a random phasor sum, the relationship between the measurement accuracy and the number of compounded angles is derived. The sensitivity analysis is validated with measurements from a tissue phantom.


Asunto(s)
Óptica y Fotónica , Tomografía de Coherencia Óptica/métodos , Calibración , Modelos Lineales , Modelos Estadísticos , Fantasmas de Imagen , Probabilidad , Refractometría , Análisis de Regresión , Reproducibilidad de los Resultados , Dispersión de Radiación
13.
Opt Lett ; 32(9): 1102-4, 2007 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-17410249

RESUMEN

Imaging large tissue areas with microscopic resolution in vivo may offer an alternative to random excisional biopsy. We present an approach for performing confocal imaging of large tissue surface areas using spectrally encoded confocal microscopy (SECM). We demonstrate a single-optical-fiber SECM apparatus, designed for imaging luminal organs, that is capable of imaging with a transverse resolution of 2.1 microm over a subsurface area of 16 cm2 in less than 1 min. Due to the unique probe configuration and scanning geometry, the speed and resolution of this new imaging technology are sufficient for comprehensively imaging large tissues areas at a microscopic scale in times that are appropriate for clinical use.


Asunto(s)
Intestinos/ultraestructura , Animales , Microscopía Confocal/instrumentación , Microscopía Confocal/métodos , Fantasmas de Imagen , Porcinos
14.
Opt Express ; 15(6): 2810-21, 2007 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-19532519

RESUMEN

Recently, we have experimentally demonstrated a new form of cross-sectional, coherence-gated fluorescence imaging referred to as SD-FCT ('spectral-domain fluorescence coherence tomography'). Imaging in SD-FCT is accomplished by spectrally detecting self-interference of the spontaneous emission of fluorophores, thereby providing depth-resolved information on the axial positions of fluorescent probes. Here, we present a theoretical investigation of the factors affecting the detected SD-FCT signal through scattering media. An imaging equation for SD-FCT is derived that includes the effects of defocusing, numerical-aperture, and the optical properties of the medium. A comparison between the optical sectioning capabilities of SD-FCT and confocal microscopy is also presented. Our results suggest that coherence gating in fluorescence imaging may provide an improved approach for depth-resolved imaging of fluorescently labeled samples; high axial resolution (a few microns) can be achieved with low numerical apertures (NA<0.09) while maintaining a large depth of field (a few hundreds of microns) in a relatively low scattering medium (6 mean free paths), whereas moderate NA's can be used to enhance depth selectivity in more highly scattering biological samples.

15.
Opt Express ; 15(10): 6200-9, 2007 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-19546925

RESUMEN

We present a novel method for rapidly acquiring optical coherence tomography (OCT) images at multiple backscattering angles. By angularly compounding these images, high levels of speckle reduction were achieved. Signal-to-noise ratio (SNR) improvements of 3.4 dB were obtained from a homogeneous tissue phantom, which was in good agreement with the predictions of a statistical model of speckle that incorporated the optical parameters of the imaging system. In addition, the fast acquisition rate of the system (10 kHz A-line repetition rate) allowed angular compounding to be performed in vivo without significant motion artifacts. Speckle-reduced OCT images of human dermis show greatly improved delineation of tissue microstructure.

17.
Opt Lett ; 31(6): 760-2, 2006 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-16544615

RESUMEN

Recent results have demonstrated unprecedented wavelength-tuning speed and repetition rate performance of semiconductor ring lasers incorporating scanning filters. However, several unique operational characteristics of these lasers have not been adequately explained, and the lack of an accurate model has hindered optimization. We numerically investigated the characteristics of these sources, using a semiconductor optical amplifier (SOA) traveling-wave Langevin model, and found good agreement with experimental measurements. In particular, we explored the role of the SOA refractive-index nonlinearities in determining the intracavity frequency-shift-broadening and the emitted power dependence on scan speed and direction. Our model predicts both continuous-wave and pulse operation and shows a universal relationship between the output power of lasers that have different cavity lengths and the filter peak frequency shift per round trip, therefore revealing the advantage of short cavities for high-speed biomedical imaging.


Asunto(s)
Amplificadores Electrónicos , Ingeniería Biomédica/instrumentación , Ingeniería Biomédica/métodos , Diseño Asistido por Computadora , Rayos Láser , Refractometría/instrumentación , Refractometría/métodos , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo/métodos , Modelos Teóricos , Dinámicas no Lineales , Óptica y Fotónica , Reproducibilidad de los Resultados , Semiconductores , Sensibilidad y Especificidad
18.
Opt Lett ; 31(3): 362-4, 2006 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-16480209

RESUMEN

A novel optical frequency-domain imaging system is demonstrated that employs a passive optical demodulation circuit and a chirped digital acquisition clock derived from a voltage-controlled oscillator. The demodulation circuit allows the separation of signals from positive and negative depths to better than 50 dB, thereby eliminating depth degeneracy and doubling the imaging depth range. Our system design is compatible with dual-balanced and polarization-diverse detection, important techniques in the practical biomedical application of optical frequency-domain imaging.


Asunto(s)
Aumento de la Imagen/instrumentación , Imagenología Tridimensional/instrumentación , Óptica y Fotónica/instrumentación , Refractometría/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Tomografía de Coherencia Óptica/instrumentación , Conversión Analogo-Digital , Diseño de Equipo , Análisis de Falla de Equipo , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Refractometría/métodos , Tomografía de Coherencia Óptica/métodos
19.
Bull Soc Belge Ophtalmol ; (302): 123-32, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17265794

RESUMEN

We present ultra-high resolution optical coherence tomography (OCT) structural intensity and optical Doppler tomography (ODT) flow velocity images of the human retina in vivo. The ultra-high speed OCT system is based on Spectral Domain or Fourier Domain technology, which provides a sensitivity advantage over conventional OCT of more than 2 orders of magnitude. This sensitivity improvement allows video rate OCT and ODT cross sectional imaging of retinal structures. Images will be presented with axial resolutions of 6 and 3.5 microns. We observed small features in the inner and outer plexiform layers, which are believed to be small blood vessels. Flow velocity images will be presented showing pulsatile flow in retinal arteries and veins.


Asunto(s)
Técnicas de Diagnóstico Oftalmológico/instrumentación , Vasos Retinianos/anatomía & histología , Tomografía de Coherencia Óptica/instrumentación , Tomografía de Coherencia Óptica/métodos , Diagnóstico por Imagen/instrumentación , Diagnóstico por Imagen/métodos , Humanos , Flujometría por Láser-Doppler , Disco Óptico/anatomía & histología , Disco Óptico/citología , Valores de Referencia , Flujo Sanguíneo Regional
20.
Opt Express ; 14(2): 726-35, 2006 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-19503391

RESUMEN

Full-field optical coherence microscopy (FFOCM) is an interferometric technique for obtaining wide-field microscopic images deep within scattering biological samples. FFOCM has primarily been implemented in the 0.8 mum wavelength range with silicon-based cameras, which may limit penetration when imaging human tissue. In this paper, we demonstrate FFOCM at the wavelength range of 0.9 - 1.4 mum, where optical penetration into tissue is presumably greater owing to decreased scattering. Our FFOCM system, comprising a broadband spatially incoherent light source, a Linnik interferometer, and an InGaAs area scan camera, provided a detection sensitivity of 86 dB for a 2 sec imaging time and an axial resolution of 1.9 mum in water. Images of phantoms, tissue samples, and Xenopus Laevis embryos were obtained using InGaAs and silicon camera FFOCM systems, demonstrating enhanced imaging penetration at longer wavelengths.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...