Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Int J Infect Dis ; 139: 168-170, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38151115

RESUMEN

We evaluated the performance of 12 lateral flow devices by assessing their analytical sensitivity for SARS-CoV-2 variant BA.2.86. Kits from ACON, Orient Gene, Xiamen Biotime, Getein, and SureScreen detected variant BA.2.86 to sufficient sensitivity levels, comparable to those observed with previous Omicron variants. The stocks of lateral flow devices currently held by the UK government do not currently need changing for deployment for this variant.


Asunto(s)
COVID-19 , Humanos , SARS-CoV-2 , Gobierno
2.
J Clin Pathol ; 76(11): 770-777, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36041815

RESUMEN

BACKGROUND: Serological tests are widely used in various medical disciplines for diagnostic and monitoring purposes. Unfortunately, the sensitivity and specificity of test systems are often poor, leaving room for false-positive and false-negative results. However, conventional methods were used to increase specificity and decrease sensitivity and vice versa. Using SARS-CoV-2 serology as an example, we propose here a novel testing strategy: the 'sensitivity improved two-test' or 'SIT²' algorithm. METHODS: SIT² involves confirmatory retesting of samples with results falling in a predefined retesting zone of an initial screening test, with adjusted cut-offs to increase sensitivity. We verified and compared the performance of SIT² to single tests and orthogonal testing (OTA) in an Austrian cohort (1117 negative, 64 post-COVID-positive samples) and validated the algorithm in an independent British cohort (976 negatives and 536 positives). RESULTS: The specificity of SIT² was superior to single tests and non-inferior to OTA. The sensitivity was maintained or even improved using SIT² when compared with single tests or OTA. SIT² allowed correct identification of infected individuals even when a live virus neutralisation assay could not detect antibodies. Compared with single testing or OTA, SIT² significantly reduced total test errors to 0.46% (0.24-0.65) or 1.60% (0.94-2.38) at both 5% or 20% seroprevalence. CONCLUSION: For SARS-CoV-2 serology, SIT² proved to be the best diagnostic choice at both 5% and 20% seroprevalence in all tested scenarios. It is an easy to apply algorithm and can potentially be helpful for the serology of other infectious diseases.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Estudios Seroepidemiológicos , Técnicas de Laboratorio Clínico/métodos , Prueba de COVID-19 , Sensibilidad y Especificidad
3.
Microbiol Spectr ; 10(1): e0228921, 2022 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-35196807

RESUMEN

In March 2020, the Rare and Imported Pathogens Laboratory at the UK Health Security Agency (UKHSA) (formerly Public Health England [PHE]) Porton Down, was tasked by the Department of Health and Social Care with setting up a national surveillance laboratory facility to study SARS-CoV-2 antibody responses and population-level sero-surveillance in response to the growing SARS-CoV-2 outbreak. In the following 12 months, the laboratory tested more than 160,000 samples, facilitating a wide range of research and informing UKHSA, DHSC, and UK government policy. Here we describe the implementation and use of the Euroimmun anti-SARS-CoV-2 IgG assay and provide an extended evaluation of its performance. We present a markedly improved overall sensitivity of 91.39% (≥14 days 92.74%, ≥21 days 93.59%) compared to our small-scale early study, and a specificity of 98.56%. In addition, we detail extended characteristics of the Euroimmun assay: intra- and interassay precision, correlation to neutralization, and assay linearity. IMPORTANCE Serology assays have been useful in determining those with previous SARS-CoV-2 infection in a wide range of research and serosurveillance projects. However, assays vary in their sensitivity at detecting SARS-CoV-2 antibodies. Here, we detail an extended evaluation and characterization of the Euroimmun anti-SARS-CoV-2 IgG assay, one that has been widely used within the United Kingdom on over 160,000 samples to date.


Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/métodos , COVID-19/sangre , Inmunoglobulina G/sangre , SARS-CoV-2/inmunología , COVID-19/diagnóstico , COVID-19/epidemiología , COVID-19/virología , Humanos , Salud Pública , Juego de Reactivos para Diagnóstico , SARS-CoV-2/genética , Sensibilidad y Especificidad , Reino Unido/epidemiología
4.
BMC Infect Dis ; 21(1): 1170, 2021 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-34800996

RESUMEN

BACKGROUND: Convalescent plasma has been widely used to treat COVID-19 and is under investigation in numerous randomized clinical trials, but results are publicly available only for a small number of trials. The objective of this study was to assess the benefits of convalescent plasma treatment compared to placebo or no treatment and all-cause mortality in patients with COVID-19, using data from all available randomized clinical trials, including unpublished and ongoing trials (Open Science Framework, https://doi.org/10.17605/OSF.IO/GEHFX ). METHODS: In this collaborative systematic review and meta-analysis, clinical trial registries (ClinicalTrials.gov, WHO International Clinical Trials Registry Platform), the Cochrane COVID-19 register, the LOVE database, and PubMed were searched until April 8, 2021. Investigators of trials registered by March 1, 2021, without published results were contacted via email. Eligible were ongoing, discontinued and completed randomized clinical trials that compared convalescent plasma with placebo or no treatment in COVID-19 patients, regardless of setting or treatment schedule. Aggregated mortality data were extracted from publications or provided by investigators of unpublished trials and combined using the Hartung-Knapp-Sidik-Jonkman random effects model. We investigated the contribution of unpublished trials to the overall evidence. RESULTS: A total of 16,477 patients were included in 33 trials (20 unpublished with 3190 patients, 13 published with 13,287 patients). 32 trials enrolled only hospitalized patients (including 3 with only intensive care unit patients). Risk of bias was low for 29/33 trials. Of 8495 patients who received convalescent plasma, 1997 died (23%), and of 7982 control patients, 1952 died (24%). The combined risk ratio for all-cause mortality was 0.97 (95% confidence interval: 0.92; 1.02) with between-study heterogeneity not beyond chance (I2 = 0%). The RECOVERY trial had 69.8% and the unpublished evidence 25.3% of the weight in the meta-analysis. CONCLUSIONS: Convalescent plasma treatment of patients with COVID-19 did not reduce all-cause mortality. These results provide strong evidence that convalescent plasma treatment for patients with COVID-19 should not be used outside of randomized trials. Evidence synthesis from collaborations among trial investigators can inform both evidence generation and evidence application in patient care.


Asunto(s)
COVID-19 , COVID-19/terapia , Humanos , Inmunización Pasiva , Ensayos Clínicos Controlados Aleatorios como Asunto , SARS-CoV-2 , Resultado del Tratamiento , Sueroterapia para COVID-19
5.
Nat Commun ; 12(1): 1951, 2021 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-33782398

RESUMEN

Serological detection of antibodies to SARS-CoV-2 is essential for establishing rates of seroconversion in populations, and for seeking evidence for a level of antibody that may be protective against COVID-19 disease. Several high-performance commercial tests have been described, but these require centralised laboratory facilities that are comparatively expensive, and therefore not available universally. Red cell agglutination tests do not require special equipment, are read by eye, have short development times, low cost and can be applied at the Point of Care. Here we describe a quantitative Haemagglutination test (HAT) for the detection of antibodies to the receptor binding domain of the SARS-CoV-2 spike protein. The HAT has a sensitivity of 90% and specificity of 99% for detection of antibodies after a PCR diagnosed infection. We will supply aliquots of the test reagent sufficient for ten thousand test wells free of charge to qualified research groups anywhere in the world.


Asunto(s)
Anticuerpos Antivirales/análisis , Prueba de COVID-19/métodos , COVID-19/diagnóstico , Pruebas de Hemaglutinación/métodos , SARS-CoV-2/aislamiento & purificación , Glicoproteína de la Espiga del Coronavirus/inmunología , Pruebas de Aglutinación/métodos , Anticuerpos Monoclonales/inmunología , Anticuerpos Antivirales/sangre , Anticuerpos Antivirales/inmunología , COVID-19/sangre , COVID-19/inmunología , COVID-19/virología , Ensayo de Inmunoadsorción Enzimática/métodos , Humanos , Sistemas de Atención de Punto , Reacción en Cadena de la Polimerasa , SARS-CoV-2/inmunología , Sensibilidad y Especificidad , Seroconversión
6.
Transfus Med ; 31(3): 167-175, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33333627

RESUMEN

INTRODUCTION: The lack of approved specific therapeutic agents to treat coronavirus disease (COVID-19) associated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection has led to the rapid implementation of convalescent plasma therapy (CPT) trials in many countries, including the United Kingdom. Effective CPT is likely to require high titres of neutralising antibody (nAb) in convalescent donations. Understanding the relationship between functional neutralising antibodies and antibody levels to specific SARS-CoV-2 proteins in scalable assays will be crucial for the success of a large-scale collection. We assessed whether neutralising antibody titres correlated with reactivity in a range of enzyme-linked immunosorbent assays (ELISA) targeting the spike (S) protein, the main target for human immune response. METHODS: Blood samples were collected from 52 individuals with a previous laboratory-confirmed SARS-CoV-2 infection. These were assayed for SARS-CoV-2 nAbs by microneutralisation and pseudo-type assays and for antibodies by four different ELISAs. Receiver operating characteristic (ROC) analysis was used to further identify sensitivity and specificity of selected assays to identify samples containing high nAb levels. RESULTS: All samples contained SARS-CoV-2 antibodies, whereas neutralising antibody titres of greater than 1:20 were detected in 43 samples (83% of those tested) and >1:100 in 22 samples (42%). The best correlations were observed with EUROimmun immunoglobulin G (IgG) reactivity (Spearman Rho correlation coefficient 0.88; p < 0.001). Based on ROC analysis, EUROimmun would detect 60% of samples with titres of >1:100 with 100% specificity using a reactivity index of 9.1 (13/22). DISCUSSION: Robust associations between nAb titres and reactivity in several ELISA-based antibody tests demonstrate their possible utility for scaled-up production of convalescent plasma containing potentially therapeutic levels of anti-SARS-CoV-2 nAbs.


Asunto(s)
Anticuerpos Neutralizantes/sangre , COVID-19/terapia , SARS-CoV-2/inmunología , Anticuerpos Antivirales/sangre , Donantes de Sangre , COVID-19/diagnóstico , Prueba de COVID-19 , Ensayo de Inmunoadsorción Enzimática/métodos , Humanos , Inmunización Pasiva/métodos , Masculino , Curva ROC , Sensibilidad y Especificidad , Sueroterapia para COVID-19
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...