Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 148
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-31328049

RESUMEN

Quantitative measurement of functional and anatomical traits of 4D tongue motion in the course of speech or other lingual behaviors remains a major challenge in scientific research and clinical applications. Here, we introduce a statistical multimodal atlas of 4D tongue motion using healthy subjects, which enables a combined quantitative characterization of tongue motion in a reference anatomical configuration. This atlas framework, termed Speech Map, combines cine- and tagged-MRI in order to provide both the anatomic reference and motion information during speech. Our approach involves a series of steps including (1) construction of a common reference anatomical configuration from cine-MRI, (2) motion estimation from tagged-MRI, (3) transformation of the motion estimations to the reference anatomical configuration, and (4) computation of motion quantities such as Lagrangian strain. Using this framework, the anatomic configuration of the tongue appears motionless, while the motion fields and associated strain measurements change over the time course of speech. In addition, to form a succinct representation of the high-dimensional and complex motion fields, principal component analysis is carried out to characterize the central tendencies and variations of motion fields of our speech tasks. Our proposed method provides a platform to quantitatively and objectively explain the differences and variability of tongue motion by illuminating internal motion and strain that have so far been intractable. The findings are used to understand how tongue function for speech is limited by abnormal internal motion and strain in glossectomy patients.

2.
IEEE Trans Med Imaging ; 38(3): 730-740, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30235120

RESUMEN

Muscle coordination patterns of lingual behaviors are synergies generated by deforming local muscle groups in a variety of ways. Functional units are functional muscle groups of local structural elements within the tongue that compress, expand, and move in a cohesive and consistent manner. Identifying the functional units using tagged-magnetic resonance imaging (MRI) sheds light on the mechanisms of normal and pathological muscle coordination patterns, yielding improvement in surgical planning, treatment, or rehabilitation procedures. In this paper, to mine this information, we propose a matrix factorization and probabilistic graphical model framework to produce building blocks and their associated weighting map using motion quantities extracted from tagged-MRI. Our tagged-MRI imaging and accurate voxel-level tracking provide previously unavailable internal tongue motion patterns, thus revealing the inner workings of the tongue during speech or other lingual behaviors. We then employ spectral clustering on the weighting map to identify the cohesive regions defined by the tongue motion that may involve multiple or undocumented regions. To evaluate our method, we perform a series of experiments. We first use two-dimensional images and synthetic data to demonstrate the accuracy of our method. We then use three-dimensional synthetic and in vivo tongue motion data using protrusion and simple speech tasks to identify subject-specific and data-driven functional units of the tongue in localized regions.


Asunto(s)
Algoritmos , Lengua/diagnóstico por imagen , Lengua/fisiología , Análisis por Conglomerados , Humanos , Imagen por Resonancia Magnética/métodos , Habla
3.
J Patient Saf ; 12(1): 40-3, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25136850

RESUMEN

BACKGROUND: In November 2010, the American College of Cardiology Foundation published revised appropriateness criteria (AC) for cardiac computed tomography (CT). We evaluated adherence to these criteria by providers of different subspecialties at a tertiary referral center. METHODS: Reports of 383 consecutive patients who underwent clinically indicated cardiac CT from December 1, 2010, to July 31, 2011, were reviewed by physicians with appropriate training in cardiac CT. Scans were classified as appropriate, inappropriate, or uncertain based on the revised 2010 AC. Studies that did not fall under any of the specified indications were labeled as unclassified. Adherence to the AC was also analyzed as a function of provider type. Research scans were excluded from this analysis. RESULTS: Three hundred eight exams (80%) were classified as appropriate; 26 (7%), as inappropriate; 30 (8%), as uncertain; and 19 (5%), as unclassified. Of the 19 (5%) unclassified cardiac CT exams, the most common indication was for evaluation of suspected aortic dissection. Three hundred five exams (80%) were referred by cardiologists; 73 (19%), by internists; and 5 (1%), by neurologists. Of the 305 cardiology-referred studies, 221 (73%) were ordered by general cardiologists; 28 (9%), by interventional cardiologists; and 56 (19%), by electrophysiologists. There was no significant difference in adherence to the criteria between provider specialties or between cardiology subspecialties (P > 0.05). CONCLUSIONS: high across provider specialties.


Asunto(s)
Cardiología/métodos , Adhesión a Directriz/normas , Centros de Atención Terciaria/normas , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Personal de Salud , Humanos , Derivación y Consulta , Sociedades Médicas , Estados Unidos
4.
Mol Imaging ; 132014.
Artículo en Inglés | MEDLINE | ID: mdl-25248283

RESUMEN

Despite extensive preclinical imaging with radiotracers developed by continuous-flow microfluidics, a positron emission tomographic (PET) radiopharmaceutical has not been reported for human imaging studies by this technology. The goal of this study was to validate the synthesis of the tau radiopharmaceutical 7-(6-fluoropyridin-3-yl)-5H-pyrido[4,3-b]indole ([18F]T807) and perform first-in-human PET scanning enabled by microfluidic flow chemistry. [18F]T807 was synthesized by our modified one-step method and adapted to suit a commercial microfluidic flow chemistry module. For this proof of concept, the flow system was integrated to a GE Tracerlab FXFN unit for high-performance liquid chromatography purification and formulation. Three consecutive productions of [18F]T807 were conducted to validate this radiopharmaceutical. Uncorrected radiochemical yields of 17 ± 1% of crude [18F]T807 (≈ 500 mCi, radiochemical purity 95%) were obtained from the microfluidic device. The crude material was then purified, and > 100 mCi of the final product was obtained in an overall uncorrected radiochemical yield of 5 ± 1% (n  =  3), relative to starting [18F]fluoride (end of bombardment), with high radiochemical purity (≥ 99%) and high specific activities (6 Ci/µmol) in 100 minutes. A clinical research study was carried out with [18F]T807, representing the first reported human imaging study with a radiopharmaceutical prepared by this technology.


Asunto(s)
Encéfalo/diagnóstico por imagen , Carbolinas/farmacocinética , Tomografía de Emisión de Positrones/métodos , Radiofármacos/farmacocinética , Adulto , Carbolinas/síntesis química , Cromatografía Líquida de Alta Presión , Humanos , Masculino , Microfluídica/instrumentación , Radiofármacos/síntesis química
5.
ACS Med Chem Lett ; 5(6): 668-72, 2014 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-24944741

RESUMEN

Bexarotene (Targretin) is a retinoid X receptor (RXR) agonist that has applications for treatment of T cell lymphoma and proposed mechanisms of action in Alzheimer's disease that have been the subject of recent controversy. Carbon-11 labeled bexarotene ([(11)C-carbonyl]4-[1-(3,5,5,8,8-pentamethyltetralin-2-yl)ethenyl]benzoic acid) was synthesized using a Cu-mediated cross-coupling reaction employing an arylboronate precursor 1 and [(11)C]carbon dioxide under atmospheric pressure in 15 ± 2% uncorrected radiochemical yield (n = 3), based on [(11)C]CO2. Judicious choice of solvents, catalysts, and additives, as well as precursor concentration and purity of [(11)C]CO2, enabled the preparation of this (11)C-labeled carboxylic acid. Formulated [(11)C]bexarotene was isolated (>37 mCi) with >99% radiochemical purity in 32 min. Preliminary positron emission tomography-magnetic resonance imaging revealed rapid brain uptake in nonhuman primate in the first 75 s following intravenous administration of the radiotracer (specific activity >0.3 Ci/µmol at time of injection), followed by slow clearance (Δ = -43%) over 60 min. Modest uptake (SUVmax = 0.8) was observed in whole brain and regions with high RXR expression.

6.
Circ Cardiovasc Imaging ; 7(4): 629-38, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24906356

RESUMEN

BACKGROUND: Coronary computed tomographic angiography (CCTA) is an accurate test for the identification of coronary artery disease (CAD), yet the impact of CCTA results on subsequent medical therapy and risk factors has not been widely reported. METHODS AND RESULTS: We identified consecutive patients aged >18 years without prior CAD who underwent CCTA from 2004 to 2011 and had complete data on medications before and after CCTA. CCTA results were categorized as no CAD, <50% stenosis, and ≥50% stenosis. Based on the number of involved segments, extent of disease was categorized as nonextensive (≤4 segments) or extensive CAD (>4 segments). Electronic medical records and patient interviews were reviewed blinded to CCTA findings to assess initiation of aspirin and intensification of lipid-lowering therapies. Survival analysis was performed to evaluate intensification of lipid therapy as a predictor of cardiovascular death or nonfatal myocardial infarction. Among 2839 patients with mean follow-up of 3.6 years, the odds of physician intensification of lipid-lowering therapy significantly increased for those with nonobstructive CAD (odds ratio, 3.6; 95% confidence interval, 2.9-4.9; P<0.001) and obstructive CAD (odds ratio, 5.6; 95% confidence interval, 4.3-7.3; P<0.001). Low-density lipoprotein cholesterol levels declined significantly in association with intensification of lipid-lowering therapy after CCTA in all patient subgroups. In a hypothesis-generating analysis, among patients with nonobstructive but extensive CAD, statin use after CCTA was associated with a reduction in cardiovascular death or myocardial infarction (hazards ratio, 0.18; 95% confidence interval, 0.05-0.66; P=0.01). CONCLUSIONS: Abnormal CCTA findings are associated with downstream intensification in statin and aspirin therapy. In particular, CCTA may lead to increased use of prognostically beneficial therapies in patients identified as having extensive, nonobstructive CAD.


Asunto(s)
Aspirina/uso terapéutico , LDL-Colesterol/sangre , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Tomografía Computarizada Multidetector , Medición de Riesgo/métodos , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/prevención & control , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Massachusetts/epidemiología , Persona de Mediana Edad , Oportunidad Relativa , Inhibidores de Agregación Plaquetaria/uso terapéutico , Pronóstico , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad
7.
Med Phys ; 41(4): 041910, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24694141

RESUMEN

PURPOSE: Artifacts caused by head motion present a major challenge in brain positron emission tomography (PET) imaging. The authors investigated the feasibility of using wired active MR microcoils to track head motion and incorporate the measured rigid motion fields into iterative PET reconstruction. METHODS: Several wired active MR microcoils and a dedicated MR coil-tracking sequence were developed. The microcoils were attached to the outer surface of an anthropomorphic(18)F-filled Hoffman phantom to mimic a brain PET scan. Complex rotation/translation motion of the phantom was induced by a balloon, which was connected to a ventilator. PET list-mode and MR tracking data were acquired simultaneously on a PET-MR scanner. The acquired dynamic PET data were reconstructed iteratively with and without motion correction. Additionally, static phantom data were acquired and used as the gold standard. RESULTS: Motion artifacts in PET images were effectively removed by wired active MR microcoil based motion correction. Motion correction yielded an activity concentration bias ranging from -0.6% to 3.4% as compared to a bias ranging from -25.0% to 16.6% if no motion correction was applied. The contrast recovery values were improved by 37%-156% with motion correction as compared to no motion correction. The image correlation (mean ± standard deviation) between the motion corrected (uncorrected) images of 20 independent noise realizations and static reference was R(2) = 0.978 ± 0.007 (0.588 ± 0.010, respectively). CONCLUSIONS: Wired active MR microcoil based motion correction significantly improves brain PET quantitative accuracy and image contrast.


Asunto(s)
Artefactos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/instrumentación , Movimiento , Fantasmas de Imagen , Tomografía de Emisión de Positrones/instrumentación , Encéfalo/diagnóstico por imagen , Factores de Tiempo
8.
Circ Cardiovasc Imaging ; 7(2): 282-91, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24550435

RESUMEN

BACKGROUND: The contribution of plaque extent to predict cardiovascular events among patients with nonobstructive and obstructive coronary artery disease (CAD) is not well defined. Our objective was to evaluate the prognostic value of plaque extent detected by coronary computed tomography angiography. METHODS AND RESULTS: All consecutive patients without prior CAD referred for coronary computed tomography angiography to evaluate for CAD were included. Examination findings were classified as normal, nonobstructive (<50% stenosis), or obstructive (≥50%). Based on the number of segments with disease, extent of CAD was classified as nonextensive (≤4 segments) or extensive (>4 segments). The cohort included 3242 patients followed for the primary outcome of cardiovascular death or myocardial infarction for a median of 3.6 (2.1-5.0) years. In a multivariable analysis, the presence of extensive nonobstructive CAD (hazard ratio, 3.1; 95% confidence interval, 1.5-6.4), nonextensive obstructive (hazard ratio, 3.0; 95% confidence interval, 1.3-6.9), and extensive obstructive CAD (hazard ratio, 3.9; 95% confidence interval, 2.2-7.2) were associated with an increased rate of events, whereas nonextensive, nonobstructive CAD was not. The addition of plaque extent to a model that included clinical probability as well as the presence and severity of CAD improved risk prediction. CONCLUSIONS: Among patients with nonobstructive CAD, those with extensive plaque experienced a higher rate of cardiovascular death or myocardial infarction, comparable with those who have nonextensive disease. Even among patients with obstructive CAD, greater extent of nonobstructive plaque was associated with higher event rate. Our findings suggest that regardless of whether obstructive or nonobstructive disease is present, the extent of plaque detected by coronary computed tomography angiography enhances risk assessment.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Muerte Súbita Cardíaca/etiología , Infarto del Miocardio/diagnóstico por imagen , Medición de Riesgo/métodos , Tomografía Computarizada por Rayos X , Enfermedad de la Arteria Coronaria/complicaciones , Muerte Súbita Cardíaca/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Massachusetts/epidemiología , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Infarto del Miocardio/etiología , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias , Factores de Tiempo
9.
Atherosclerosis ; 233(1): 190-5, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24529143

RESUMEN

OBJECTIVE: To evaluate the prognostic value and test characteristics of coronary artery calcium (CAC) score for the identification of obstructive coronary artery disease (CAD) in comparison with coronary computed tomography angiography (CCTA) among symptomatic patients. METHODS: Retrospective cohort study at two large hospitals, including all symptomatic patients without prior CAD who underwent both CCTA and CAC. Accuracy of CAC for the identification of ≥ 50% and ≥ 70% stenosis by CCTA was evaluated. Prognostic value of CAC and CCTA were compared for prediction of major adverse cardiovascular events (MACE, defined as non-fatal myocardial infarction, cardiovascular death, late coronary revascularization (>90 days), and unstable angina requiring hospitalization). RESULTS: Among 1145 included patients, the mean age was 55 ± 12 years and median follow up 2.4 (IQR: 1.5-3.5) years. Overall, 406 (35%) CCTA were normal, 454 (40%) had <50% stenosis, and 285 (25%) had ≥ 50% stenosis. The prevalence of ≥ 70% stenosis was 16%. Among 483 (42%) patients with CAC zero, 395 (82%) had normal CCTA, 81 (17%) <50% stenosis, and 7 (1.5%) ≥ 50% stenosis. 2 (0.4%) patients had ≥ 70% stenosis. For diagnosis of ≥ 50% stenosis, CAC had a sensitivity of 98% and specificity of 55%. The negative predictive value (NPV) for CAC was 99% for ≥ 50% stenosis and 99.6% for ≥ 70% stenosis by CCTA. There were no adverse events among the 7 patients with zero calcium and ≥ 50% CAD. For prediction of MACE, the c-statistic for clinical risk factors of 0.62 increased to 0.73 (p < 0.001) with CAC versus 0.77 (p = 0.02) with CCTA. CONCLUSION: Among symptomatic patients with CAC zero, a 1-2% prevalence of potentially obstructive CAD occurs, although this finding was not associated with future coronary revascularization or adverse prognosis within 2 years.


Asunto(s)
Calcinosis/diagnóstico por imagen , Calcio/análisis , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Enfermedades Cardiovasculares/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Sensibilidad y Especificidad
10.
Neuroimage ; 91: 129-37, 2014 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-24418501

RESUMEN

Brain PET scanning plays an important role in the diagnosis, prognostication and monitoring of many brain diseases. Motion artifacts from head motion are one of the major hurdles in brain PET. In this work, we propose to use wireless MR active markers to track head motion in real time during a simultaneous PET-MR brain scan and incorporate the motion measured by the markers in the listmode PET reconstruction. Several wireless MR active markers and a dedicated fast MR tracking pulse sequence module were built. Data were acquired on an ACR Flangeless PET phantom with multiple spheres and a non-human primate with and without motion. Motions of the phantom and monkey's head were measured with the wireless markers using a dedicated MR tracking sequence module. The motion PET data were reconstructed using list-mode reconstruction with and without motion correction. Static reference was used as gold standard for quantitative analysis. The motion artifacts, which were prominent on the images without motion correction, were eliminated by the wireless marker based motion correction in both the phantom and monkey experiments. Quantitative analysis was performed on the phantom motion data from 24 independent noise realizations. The reduction of bias of sphere-to-background PET contrast by active marker based motion correction ranges from 26% to 64% and 17% to 25% for hot (i.e., radioactive) and cold (i.e., non-radioactive) spheres, respectively. The motion correction improved the channelized Hotelling observer signal-to-noise ratio of the spheres by 1.2 to 6.9 depending on their locations and sizes. The proposed wireless MR active marker based motion correction technique removes the motion artifacts in the reconstructed PET images and yields accurate quantitative values.


Asunto(s)
Movimientos de la Cabeza , Procesamiento de Imagen Asistido por Computador/métodos , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/métodos , Tecnología Inalámbrica , Algoritmos , Animales , Artefactos , Electrocardiografía , Humanos , Macaca mulatta , Imagen por Resonancia Magnética/estadística & datos numéricos , Fantasmas de Imagen , Tomografía de Emisión de Positrones/estadística & datos numéricos , Radiofármacos , Relación Señal-Ruido
11.
Eur J Prev Cardiol ; 21(8): 972-9, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23539717

RESUMEN

BACKGROUND: HIV-infected patients are at increased risk of coronary artery disease (CAD). We evaluated the cost-effectiveness of cardiac screening for HIV-positive men at intermediate or greater CAD risk. DESIGN: We developed a lifetime microsimulation model of CAD incidence and progression in HIV-infected men. METHODS: Input parameters were derived from two HIV cohort studies and the literature. We compared no CAD screening with stress testing and coronary computed tomography angiography (CCTA)-based strategies. Patients with test results indicating 3-vessel/left main CAD underwent invasive coronary angiography (ICA) and received coronary artery bypass graft surgery. In the stress testing + medication and CCTA + medication strategies, patients with 1-2-vessel CAD results received lifetime medical treatment without further diagnostics whereas in the stress testing + intervention and CCTA + intervention strategies, patients with these results underwent ICA and received percutaneous coronary intervention. RESULTS: Compared to no screening, the stress testing + medication, stress testing + intervention, CCTA + medication, and CCTA + intervention strategies resulted in 14, 11, 19, and 14 quality-adjusted life days per patient and incremental cost-effectiveness ratios of 49,261, 57,817, 34,887 and 56,518 Euros per quality-adjusted life year (QALY), respectively. Screening only at higher CAD risk thresholds was more cost-effective. Repeated screening was clinically beneficial compared to one-time screening, but only stress testing + medication every 5 years remained cost-effective. At a willingness-to-pay threshold of 83,000 €/QALY (∼ 100,000 US$/QALY), implementing any CAD screening was cost-effective with a probability of 75-95%. CONCLUSIONS: Screening HIV-positive men for CAD would be clinically beneficial and comes at a cost-effectiveness ratio comparable to other accepted interventions in HIV care.


Asunto(s)
Angiografía Coronaria/economía , Enfermedad de la Arteria Coronaria/diagnóstico , Ecocardiografía de Estrés/economía , Electrocardiografía/economía , Infecciones por VIH/complicaciones , Tamizaje Masivo/economía , Tomografía Computarizada por Rayos X/economía , Adulto , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/fisiopatología , Análisis Costo-Beneficio , Progresión de la Enfermedad , Humanos , Incidencia , Masculino , Cadenas de Markov , Persona de Mediana Edad , Prevalencia , Años de Vida Ajustados por Calidad de Vida , Factores de Riesgo
13.
Pediatr Cardiol ; 35(1): 171-9, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23872908

RESUMEN

Cardiac CT angiography (cCTA) has become an established method for the assessment of congenital heart disease. However, the potential harmful effects of ionizing radiation must be considered, particularly in younger, more radiosensitive patients. In this study, we sought to assess the temporal change in radiation doses from pediatric cCTA during an 8-year period at a tertiary medical center. This retrospective study included all patients ≤18 years old who were referred to electrocardiography (ECG)-gated cCTA for the assessment of congenital heart disease or inflammatory disease (Kawasaki disease) from November 2004 to September 2012. During the study period, 95 patients were scanned using 3 different scanner models-64-slice multidetector CT (64-MDCT) and first- (64-DSCT) and second-generation (128-DSCT) dual-source CT-and 3 scan protocols-retrospective ECG-gated helical scanning (RG), prospective ECG-triggered axial scanning (PT), or prospective ECG-triggered high-pitch helical scanning (HPH). Effective dose (ED) was calculated with the dose length product method with a conversion factor (k) adjusted for age. ED was then compared among scan protocols. Image quality was extracted from clinical cCTA reports when available. Overall, 94 % of scans were diagnostic (80 % for 64-slice MDCT, 93 % for 64-slice DSCT, and 97 % for 128-slice DSCT).With 128-DSCT, median ED (1.0 [range 0.6-2.0] mSv) decreased by 85.8 % and 66.8 % compared with 64-MDCT (6.8 [range 2.9-13.6] mSv) and 64-DSCT (2.9 [range 0.9-4.1] mSv), respectively. With HPH, median ED (0.9 [range 0.6-1.8] mSv) decreased by 59.4 % and 85.4 % compared with PT (2.2 [range 0.9-3.4] mSv) and RG (6.1 [range 2.5-10.6] mSv). cCTA can now be obtained at very low radiation doses in pediatric patients using the latest dual-source CT technology in combination with prospective ECG-triggered HPH acquisition.


Asunto(s)
Angiografía , Cardiopatías Congénitas/diagnóstico por imagen , Síndrome Mucocutáneo Linfonodular/diagnóstico por imagen , Traumatismos por Radiación/prevención & control , Radiación Ionizante , Tomografía Computarizada por Rayos X , Adolescente , Angiografía/efectos adversos , Angiografía/métodos , Angiografía/normas , Preescolar , Relación Dosis-Respuesta en la Radiación , Electrocardiografía , Femenino , Humanos , Recién Nacido , Masculino , Intensificación de Imagen Radiográfica , Salud Radiológica/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Estados Unidos
14.
Diabetes Care ; 37(2): 555-64, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24130364

RESUMEN

OBJECTIVE: Our purpose was to evaluate coronary artery disease (CAD) prevalence and prognosis according to cardiometabolic (CM) risk. RESEARCH DESIGN AND METHODS: Registry of all patients without prior CAD referred for coronary computed tomography angiography (CCTA). Patients were stratified by groups of increasing CM risk factors (hypertension, low HDL, hypertriglyceridemia, obesity, and dysglycemia) as follows: patients without type 2 diabetes mellitus (T2DM) with fewer than three or with three or more CM risk factors, patients with T2DM not requiring insulin, or those with T2DM requiring insulin. Patients were followed for a primary end point of major adverse cardiovascular events (MACE) composed of unstable angina, late coronary revascularization, myocardial infarction (MI), and cardiovascular mortality. RESULTS: Among 1,118 patients (mean age 57 ± 13 years) followed for a mean 3.1 years, there were 21 (1.9%) cardiovascular deaths and 13 (1.2%) MIs. There was a stepwise increase in the prevalence of obstructive CAD with increasing CM risk, from 15% in those without diabetes and fewer than three CM risk factors to as high as 46% in patients with T2DM requiring insulin (P < 0.001). Insulin exposure was associated with the highest adjusted hazard of MACE (hazard ratio 3.29 [95% CI 1.28-8.45], P = 0.01), whereas both T2DM without insulin (1.35, P = 0.3) and three or more CM risk factors without T2DM (1.48, P = 0.3) were associated with a similar rate of MACE. CONCLUSIONS: Patients without diabetes who have multiple metabolic risk factors have a similar prognosis and burden of CAD as those with T2DM not requiring insulin. Among patients with diabetes, the need for insulin therapy is associated with greater burden of CAD as well as worse prognosis.


Asunto(s)
Aterosclerosis/epidemiología , Enfermedad de la Arteria Coronaria/epidemiología , Diabetes Mellitus Tipo 2/epidemiología , Anciano , Aterosclerosis/diagnóstico por imagen , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Pronóstico , Sistema de Registros , Factores de Riesgo , Tomografía Computarizada por Rayos X/métodos
15.
J Labelled Comp Radiopharm ; 56(14): 736-40, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24339014

RESUMEN

Fluorine-18 labeled 7-(6-fluoropyridin-3-yl)-5H-pyrido[4,3-b]indole ([(18) F]T807) is a potent and selective agent for imaging paired helical filaments of tau and is among the most promising PET radiopharmaceuticals for this target in early clinical trials. The present study reports a simplified one-step method for the synthesis of [(18) F]T807 that is broadly applicable for routine clinical production using a GE TRACERlab™ FXFN radiosynthesis module. Key facets of our optimized radiosynthesis include development and use of a more soluble protected precursor, tert-butyl 7-(6-nitropyridin-3-yl)-5H-pyrido[4,3-b]indole-5-carboxylate, as well as new HPLC separation conditions that enable a facile one-step synthesis. During the nucleophilic fluorinating reaction with potassium cryptand [(18) F]fluoride (K[(18) F]/K222 ) in DMSO at 130 °C over 10 min the precursor is concurrently deprotected. Formulated [(18) F]T807 was prepared in an uncorrected radiochemical yield of 14 ± 3%, with a specific activity of 216 ± 60 GBq/µmol (5837 ± 1621 mCi/µmol) at the end of synthesis (60 min; n = 3) and validated for human use. This methodology offers the advantage of faster synthesis in fewer steps, with simpler automation that we anticipate will facilitate widespread clinical use of [(18) F]T807.


Asunto(s)
Carbolinas/síntesis química , Radioisótopos de Flúor/química , Marcaje Isotópico/métodos , Radiofármacos/síntesis química , Tomografía de Emisión de Positrones , Proteínas tau/metabolismo
16.
JACC Cardiovasc Imaging ; 6(12): 1250-9, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24269261

RESUMEN

OBJECTIVES: This study sought to determine whether arterial inflammation measured by (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG-PET) improves prediction of cardiovascular disease (CVD) beyond traditional risk factors. BACKGROUND: It is unknown whether arterial (18)F-FDG uptake measured with routine PET imaging provides incremental value for predicting CVD events beyond Framingham risk score (FRS). METHODS: We consecutively identified 513 individuals from 6,088 patients who underwent (18)F-FDG-PET and computed tomography (CT) imaging at Massachusetts General Hospital between 2005 and 2008 and who met additional inclusion criteria: ≥30 years of age, no prior CVD, and free of cancer. CVD events were independently adjudicated, while blinded to clinical data, using medical records to determine incident stroke, transient ischemic attack, acute coronary syndrome, revascularization, new-onset angina, peripheral arterial disease, heart failure, or CVD death. FDG uptake was measured in the ascending aorta (as target-to-background-ratio [TBR]), while blinded to clinical data. RESULTS: During follow-up (median 4.2 years), 44 participants developed CVD (2 per 100 person-years at risk). TBR strongly predicted subsequent CVD independent of traditional risk factors (hazard ratio: 4.71; 95% confidence interval [CI]: 1.98 to 11.2; p < 0.001) and (hazard ratio: 4.13; 95% CI: 1.59 to 10.76; p = 0.004) after further adjustment for coronary calcium score. Addition of arterial PET measurement to FRS scores improved the C-statistic (mean ± standard error 0.62 ± 0.03 vs. 0.66 ± 0.03). Further, incorporation of TBR into a model with FRS variables resulted in an integrated discrimination of 5% (95% CI: 0.36 to 9.87). Net reclassification improvements were 27.48% (95% CI: 16.27 to 39.92) and 22.3% (95% CI: 11.54 to 35.42) for the 10% and 6% intermediate-risk cut points, respectively. Moreover, TBR was inversely associated with the timing of CVD (beta -0.096; p < 0.0001). CONCLUSIONS: Arterial FDG uptake, measured from routinely obtained PET/CT images, substantially improved incident CVD prediction beyond FRS among individuals undergoing cancer surveillance and provided information on the potential timing of such events.


Asunto(s)
Arteritis/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones , Radiofármacos , Tomografía Computarizada por Rayos X , Adulto , Anciano , Arteritis/mortalidad , Boston , Progresión de la Enfermedad , Femenino , Hospitales Generales , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Calcificación Vascular/diagnóstico por imagen
17.
Circ Cardiovasc Imaging ; 6(5): 747-54, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23833282

RESUMEN

BACKGROUND: Arterial calcium (Ca) deposition has been identified as an active inflammatory process. We sought to test the hypothesis that local vascular inflammation predisposes to subsequent arterial calcium deposition in humans. METHODS AND RESULTS: From a hospital database, we identified 137 patients (age, 61 ± 13 years; 48.1% men) who underwent serial positron-emission tomography/computed tomography (1-5 years apart). Focal arterial inflammation was prospectively determined by measuring 18F-flourodeoxyglucose uptake (using baseline positron-emission tomography) within predetermined locations of the thoracic aortic wall and was reported as a standardized uptake value. A separate, blinded investigator evaluated calcium deposition (on the baseline and follow-up computed tomographic scans) along the same standardized sections of the aorta. New calcification was prospectively defined using square root-transformed difference of calcium volume score, with a cutoff value of 2.5. Accordingly, vascular segment was classified as either with or without subsequent calcification. Overall, 67 (9%) of aortic segments demonstrated subsequent calcification. Baseline median (interquartile range) standardized uptake value was higher in segments with versus without subsequent calcification (2.09 [1.84-2.44] versus 1.92 [1.72-2.20], P=0.002). This was also true in the subset of segments with Ca present at baseline (2.08 [1.81-2.40] versus 1.86 [1.66-2.09], P=0.02), as well as those without (2.17 [1.87-2.51] versus 1.93 [1.73-2.20], P=0.04). Furthermore, across all patients, subsequent Ca deposition was associated with the underlying 18F-flourodeoxyglucose uptake (inflammatory signal), measured as standardized uptake value (odds ratio [95% confidence interval]=2.94 [1.27-6.89], P=0.01) or target-to-background ratio (2.59 [1.18-5.70], =0.02), after adjusting for traditional cardiovascular risk factors. CONCLUSIONS: Here, we provide first-in-man evidence that arterial inflammation precedes subsequent Ca deposition, a marker of plaque progression, within the underlying location in the artery wall.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Aortitis/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Imagen Multimodal , Tomografía de Emisión de Positrones , Radiofármacos , Calcificación Vascular/diagnóstico por imagen , Adulto , Anciano , Aortografía/métodos , Distribución de Chi-Cuadrado , Progresión de la Enfermedad , Femenino , Humanos , Modelos Logísticos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Relación Señal-Ruido , Factores de Tiempo , Tomografía Computarizada por Rayos X
18.
Acad Radiol ; 20(8): 1015-23, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23830607

RESUMEN

RATIONALE AND OBJECTIVES: Numerous protocols have been developed to reduce cardiac computed tomography angiography (cCTA) radiation dose while maintaining image quality. However, cCTA practice is highly dependent on physician and technologist experience and education. In this study, we sought to evaluate the incremental value of real-time feedback via weekly dose reports on a busy cCTA service. MATERIALS AND METHODS: This time series analysis consisted of 450 consecutive patients whom underwent physician-supervised cCTA for clinically indicated native coronary evaluation between April 2011 and January 2013, with 150 patients before the initiation of weekly dose report (preintervention period: April-September 2011) and 150 patients after the initiation (postintervention period: September 2011-February 2012). To assess whether overall dose reductions were maintained over time, results were compared to a late control group consisting of 150 consecutive cCTA exams, which were performed after the study (September 2012-January 2013). Patient characteristics and effective radiation were recorded and compared. RESULTS: Total radiation dose was significantly lower in the postintervention period (3.4 mSv [1.7-5.7] and in the late control group (3.3 mSv [2.0-5.3] versus the preintervention period (4.1 mSv [2.1-6.6] (P = .005). The proportion of high-dose outliers was also decreased in the postintervention period and late control period (exams <10 mSv were 88.0% preintervention vs. 97.3% postintervention vs. 95.3% late control; exams <15 mSv were 98.0% preintervention vs. 100.0% postintervention vs. 98.7% late control; exams <20.0 mSv were 98.7% preintervention vs. 100.0% postintervention vs. 100.0% late control). CONCLUSION: Weekly dose report feedback of site radiation doses to patients undergoing physician-supervised cCTA resulted in significant overall dose reduction and reduction of high-dose outliers. Overall dose reductions were maintained beyond the initial study period.


Asunto(s)
Angiografía Coronaria/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Mejoramiento de la Calidad/estadística & datos numéricos , Dosis de Radiación , Centros de Atención Terciaria/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Angiografía Coronaria/normas , Femenino , Humanos , Masculino , Massachusetts/epidemiología , Persona de Mediana Edad , Prevalencia , Protección Radiológica , Radiometría/normas , Radiometría/estadística & datos numéricos , Reproducibilidad de los Resultados , Medición de Riesgo , Sensibilidad y Especificidad , Centros de Atención Terciaria/normas , Tomografía Computarizada por Rayos X/normas
19.
Int J Cardiovasc Imaging ; 29(6): 1361-70, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23526082

RESUMEN

In this study, we sought to evaluate the image quality and effective radiation dose of prospectively ECG-triggered adaptive systolic (PTA-systolic) dual-source CTA versus prospectively triggered adaptive diastolic (PTA-diastolic) dual-source CTA in patients of unselected heart rate and rhythm. This retrospective cohort study consisted of 41 PTA-systolic and 41 matched PTA-diastolic CTA patients whom underwent clinically indicated 128-slice dual source CTA between December 2010 to June 2012. Image quality and motion artifact score (both on a Likert scale 1-4 with 4 being the best), effective dose, and CTDIvol were compared. The effect of heart rate (HR) and heart rate variability [HRV] on image motion artifact score and CTDIvol was analyzed with Pearson's correlation coefficient. All 82 exams were considered diagnostic with 0 non-diagnostic segments. PTA-systolic CTA patients had a higher maximum HR, wider HRV, were less likely to be in sinus rhythm, and received less beta-blocker vs. PTA-diastolic CTA patients. No difference in effective dose was observed (PTA-systolic vs. PTA-diastolic CTA: 2.9 vs. 2.2 mSv, p = 0.26). Image quality score (3.3 vs. 3.5, p < 0.05) and motion artifact score (3.5 vs. 3.8, p < 0.05) were lower in PTA-systolic CTAs than in PTA-diastolic CTAs. For PTA-systolic CTAs, an increase in HR was not associated with a negative impact on motion artifact score nor CTDIvol. For PTA-diastolic CTA, an increase in HR was associated with increased motion artifacts and CTDIvol. HRV demonstrated no correlation with motion artifact and CTDIvol for both PTA-systolic and PTA-diastolic CTAs. In conclusion, both PTA-diastolic CTA and PTA-systolic CTA yielded diagnostic examinations at unselected heart rates and rhythms with similar effective radiation, but PTA-systolic CTA resulted in more consistent radiation exposure and image quality across a wide range of rates and rhythms.


Asunto(s)
Algoritmos , Arritmias Cardíacas/complicaciones , Técnicas de Imagen Sincronizada Cardíacas/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Diástole , Electrocardiografía , Tomografía Computarizada Multidetector , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Sístole , Adulto , Anciano , Arritmias Cardíacas/fisiopatología , Artefactos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos
20.
J Nucl Cardiol ; 20(3): 385-95, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23526296

RESUMEN

BACKGROUND: Bronchial asthma is a chronic inflammatory condition associated with increased cardiovascular (CV) events. Here, we assess arterial inflammation, using 18F-fluorodeoxyglucose positron emission tomography/computed tomography imaging (FDG-PET/CT), in patients with bronchial asthma and low to intermediate Framingham risk scores (FRS). METHODS: A total of 102 patients underwent FDG-PET/CT imaging for clinical indications. Thirty-four patients (mean age 54.9 ± 16.1) with mild asthma and no known atherosclerotic disease were compared to 2 non-asthmatic groups. The first control group (n = 34) were matched by age, gender, and FRS. The second control group (n = 34) had clinical atherosclerosis and were matched by gender. Thereafter, arterial FDG uptake on PET images was determined, while blinded to patient identifiers. RESULTS: Target-to-background-ratio (TBR) in the aorta was higher in asthmatics vs non-asthmatic FRS-matched controls (1.96 ± 0.26 vs 1.76 ± 0.20; P < .001). The aortic TBR remained elevated in asthmatics vs non-asthmatic controls after adjusting traditional CV risk factors (P < .001). An inverse correlation was observed between FDG uptake and lung function, FEV1 (P = .02) and peak flow (P = .03). CONCLUSIONS: Bronchial asthma is associated with increased arterial inflammation beyond that estimated by current risk stratification tools. Further studies are required to evaluate whether attenuation of systemic inflammation will decrease CV events.


Asunto(s)
Arteritis/patología , Asma/patología , Adulto , Anciano , Aorta/patología , Arteritis/complicaciones , Asma/complicaciones , Aterosclerosis/complicaciones , Femenino , Fluorodesoxiglucosa F18 , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones/métodos , Estudios Prospectivos , Radiofármacos , Pruebas de Función Respiratoria , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...