Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Bioeng Transl Med ; 9(3): e10604, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38818126

RESUMEN

Affecting millions of individuals worldwide, neurodegenerative diseases (NDDs) pose a significant and growing health concern in people over the age of 60 years. Contributing to this trend are the steady increase in the aging population coupled with a persistent lack of disease-altering treatment strategies targeting NDDs. The absence of efficient therapeutics can be attributed to high failure rates in clinical trials and the ineptness of animal models in preceding preclinical studies. To that end, in recent years, significant research effort has been dedicated to the development of human cell-based preclinical disease models characterized by a higher degree of predictive validity. However, a key requirement of any in vitro model constitutes the precise knowledge and replication of the target tissues' (patho-)physiological microenvironment. Herein, microphysiological systems have demonstrated superiority over conventional static 2D/3D in vitro cell culture systems, as they allow for the emulation and continuous monitoring of the onset, progression, and remission of disease-associated phenotypes. This review provides an overview of recent advances in the field of NDD research using organ-on-a-chip platforms. Specific focus is directed toward non-invasive sensing strategies encompassing electrical, electrochemical, and optical sensors. Additionally, promising on- and integrable off-chip sensing strategies targeting key analytes in NDDs will be presented and discussed in detail.

2.
Biosensors (Basel) ; 14(2)2024 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-38392026

RESUMEN

Due to advances in additive manufacturing and prototyping, affordable and rapid microfluidic sensor-integrated assays can be fabricated using additive manufacturing, xurography and electrode shadow masking to create versatile platform technologies aimed toward qualitative assessment of acute cytotoxic or cytolytic events using stand-alone biochip platforms in the context of environmental risk assessment. In the current study, we established a nasal mucosa biosensing platform using RPMI2650 mucosa cells inside a membrane-integrated impedance-sensing biochip using exclusively rapid prototyping technologies. In a final proof-of-concept, we applied this biosensing platform to create human cell models of nasal mucosa for monitoring the acute cytotoxic effect of zinc oxide reference nanoparticles. Our data generated with the biochip platform successfully monitored the acute toxicity and cytolytic activity of 6 mM zinc oxide nanoparticles, which was non-invasively monitored as a negative impedance slope on nasal epithelial models, demonstrating the feasibility of rapid prototyping technologies such as additive manufacturing and xurography for cell-based platform development.


Asunto(s)
Técnicas Biosensibles , Óxido de Zinc , Humanos , Impedancia Eléctrica , Microfluídica
3.
Biosens Bioelectron ; 237: 115491, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37413826

RESUMEN

Glucose is the primary energy source of human cells. Therefore, monitoring glucose inside microphysiological systems (MPS) provides valuable information on the viability and metabolic state of the cultured cells. However, continuous glucose monitoring inside MPS is challenging due to a lack of suitable miniaturized sensors. Here we present an enzymatic, optical glucose sensor element for measurement inside microfluidic systems. The miniaturized glucose sensor (Ø 1 mm) is fabricated together with a reference oxygen sensor onto biocompatible, pressure-sensitive adhesive tape for easy integration inside microfluidic systems. Furthermore, the proposed microfluidic system can be used as plug and play sensor system with existing MPS. It was characterized under cell culture conditions (37 °C and pH 7.4) for five days, exhibiting minor drift (3% day-1). The influence of further cell culture parameters like oxygen concentration, pH, flow rate, and sterilization methods was investigated. The plug-and-play system was used for at-line measurements of glucose levels in (static) cell culture and achieved good agreement with a commercially available glucose sensor. In conclusion, we developed an optical glucose sensor element that can be easily integrated in microfluidic systems and is able to perform stable glucose measurements under cell culture conditions.


Asunto(s)
Técnicas Biosensibles , Técnicas Analíticas Microfluídicas , Humanos , Microfluídica , Técnicas Analíticas Microfluídicas/métodos , Automonitorización de la Glucosa Sanguínea , Técnicas Biosensibles/métodos , Glucemia , Técnicas de Cultivo de Célula/métodos , Glucosa/metabolismo , Oxígeno/metabolismo
4.
Pharmaceutics ; 14(2)2022 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-35214071

RESUMEN

Stem cell technology and embryonic stem cell models are of great interest in biomedical research since they provide deeper insights into, e.g., neurogenesis and early mammalian brain development. Despite their great scientific potential, the reliable establishment of three-dimensional embryoid bodies (EBs) remains a major challenge, and the current lack of standardization and comparability is still limiting a broader application and translation of stem cell technology. Among others, a vital aspect for the reliable formation of EBs is optimizing differentiation protocols since organized differentiation is influenced by soluble inducers and EB size. A microfluidic biochip array was employed to automate cell loading and optimize directed neuronal and astrocytic differentiation protocols using murine P19 embryoid bodies to facilitate reliable embryonic stem cell differentiation. Our gravity-driven microfluidic size-controlled embryoid body-on-a-chip system allows (a) the robust operation and cultivation of up to 90 EBs in parallel and (b) the reproducible generation of five increasing sizes ranging from 300 µm to 1000 µm diameters. A comparative study adds two differentiation-inducers such as retinoic acid and EC23 to size-controlled embryoid bodies to identify the optimal differentiation protocol. Our study revealed a 1.4 to 1.9-fold higher neuron and astrocyte expression in larger embryoid bodies (above 750 µm) over smaller-sized EBs (below 450 µm), thus highlighting the importance of EB size in the establishment of robust neurodevelopmental in vitro models.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...