Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Magn Reson Imaging ; 111: 15-20, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38579974

RESUMEN

BACKGROUND: In patients who have difficulty holding their breath, a free breathing (FB) respiratory-triggered (RT) bSSFP cine technique may be used. However, this technique may have inferior image quality and a longer scan time than breath-hold (BH) bSSFP cine acquisitions. This study examined the effect of an audiovisual breathing guidance (BG) system on RT bSSFP cine image quality, scan time, and ventricular measurements. METHODS: This study evaluated a BG system that provides audiovisual instructions and feedback on the timing of inspiration and expiration to the patient during image acquisition using input from the respiratory bellows to guide them toward a regular breathing pattern with extended end-expiration. In this single-center prospective study in patients undergoing a clinical cardiac magnetic resonance examination, a ventricular short-axis stack of bSSFP cine images was acquired using 3 techniques in each patient: 1) FB and RT (FBRT), 2) BG system and RT (BGRT), and 3) BH. The 3 acquisitions were compared for image quality metrics (endocardial edge definition, motion artifact, and blood-to-myocardial contrast) scored on a Likert scale, scan time, and ventricular volumes and mass. RESULTS: Thirty-two patients (19 females; median age 21 years, IQR 18-32) completed the study protocol. For scan time, BGRT was faster than FBRT (163 s vs. 345 s, p < 0.001). Endocardial edge definition, motion artifact, and blood-to-myocardial contrast were all better for BGRT than FBRT (p < 0.001). Left ventricular (LV) end-systolic volume (ESV) was smaller (3%, p = 0.02) and LV ejection fraction (EF) was larger (0.5%, p = 0.003) with BGRT than with FBRT. There was no significant difference in LV end-diastolic volume (EDV), LV mass, right ventricular (RV) EDV, RV ESV, and RV EF. Scan times were shorter for BGRT compared to BH. Endocardial edge definition and blood-to-myocardial contrast were better for BH than BGRT. Compared to BH, the LV EDV, LV ESV, RV EDV, and RV ESV were mildly smaller (all differences <7%) for BGRT. CONCLUSIONS: The addition of a BG system to RT bSSFP cine acquisitions decreased the scan time and improved image quality. Further exploration of this BG approach is warranted in more diverse populations and with other free breathing sequences.


Asunto(s)
Imagen por Resonancia Cinemagnética , Humanos , Imagen por Resonancia Cinemagnética/métodos , Femenino , Masculino , Adulto , Estudios Prospectivos , Respiración , Persona de Mediana Edad , Técnicas de Imagen Sincronizada Respiratorias/métodos , Corazón/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Contencion de la Respiración , Artefactos , Reproducibilidad de los Resultados , Recursos Audiovisuales , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...