Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(14)2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39066077

RESUMEN

In the manufacturing process of electrical devices, ensuring the cleanliness of technical surfaces, such as direct bonded copper substrates, is crucial. An in-line monitoring system for quality checking must provide sufficiently resolved lateral data in a short time. UV hyperspectral imaging is a promising in-line method for rapid, contactless, and large-scale detection of contamination; thus, UV hyperspectral imaging (225-400 nm) was utilized to characterize the cleanliness of direct bonded copper in a non-destructive way. In total, 11 levels of cleanliness were prepared, and a total of 44 samples were measured to develop multivariate models for characterizing and predicting the cleanliness levels. The setup included a pushbroom imager, a deuterium lamp, and a conveyor belt for laterally resolved measurements of copper surfaces. A principal component analysis (PCA) model effectively differentiated among the sample types based on the first two principal components with approximately 100.0% explained variance. A partial least squares regression (PLS-R) model to determine the optimal sonication time showed reliable performance, with R2cv = 0.928 and RMSECV = 0.849. This model was able to predict the cleanliness of each pixel in a testing sample set, exemplifying a step in the manufacturing process of direct bonded copper substrates. Combined with multivariate data modeling, the in-line UV prototype system demonstrates a significant potential for further advancement towards its application in real-world, large-scale processes.

2.
Chemphyschem ; : e202400374, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38837881

RESUMEN

The peripherical protons of the dye molecule hypericin can undergo structural interconversion (tautomerization) between different isomers separated by a low energy barrier with rates that depends sensitively on the interaction with local chemical environment defined by the nature of host material. We investigate the deuterium (D) isotope effect of hypericin tautomerism at the single-molecule level to avoid ensemble averaging in different polymer matrices by a combined spectroscopic and computational approach. In the 'innocent' PMMA matrix only intramolecular isotope effects on the internal conversion channel and tautomerization are observed; while PVA specifically interacts with the probe via H- and D-bonding. This establishes a single molecular picture on intra- and intermolecular nano-environment effects to control chromophore photophysics and -chemistry.

3.
Diagnostics (Basel) ; 14(1)2023 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-38201401

RESUMEN

Salivary gland tumors (SGTs) are a relevant, highly diverse subgroup of head and neck tumors whose entity determination can be difficult. Confocal Raman imaging in combination with multivariate data analysis may possibly support their correct classification. For the analysis of the translational potential of Raman imaging in SGT determination, a multi-stage evaluation process is necessary. By measuring a sample set of Warthin tumor, pleomorphic adenoma and non-tumor salivary gland tissue, Raman data were obtained and a thorough Raman band analysis was performed. This evaluation revealed highly overlapping Raman patterns with only minor spectral differences. Consequently, a principal component analysis (PCA) was calculated and further combined with a discriminant analysis (DA) to enable the best possible distinction. The PCA-DA model was characterized by accuracy, sensitivity, selectivity and precision values above 90% and validated by predicting model-unknown Raman spectra, of which 93% were classified correctly. Thus, we state our PCA-DA to be suitable for parotid tumor and non-salivary salivary gland tissue discrimination and prediction. For evaluation of the translational potential, further validation steps are necessary.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...