1.
J Clin Med ; 13(3)2024 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-38337431

RESUMEN

BACKGROUND: This study investigated whether patient-specific condylar positioning devices (CPDs) are beneficial compared to the conventional manual positioning of the condyles. METHODS: In this prospective, randomized trial, patients undergoing orthognathic surgery with a bilateral sagittal split osteotomy of the mandible were included. The ascending ramus was positioned with computer-aided designed and computer-aided manufactured (CAD/CAM) patient-specific devices in the CPD group and manually in the control group. Postoperatively, cone-beam computed tomography (CBCT) was performed to align the virtually planned position with the postoperative result. RESULTS: Thirty patients were enrolled in the study, with 14 randomized to the CPD group and 16 to the control group. In the CPD group, the ascending ramus differed in the postoperative CBCT scan from the virtually planned position by 0.8 mm in the left/right, 0.8 mm in the front/back, and 1.3 mm in the cranial/caudal direction. The corresponding control-group values were 1.1 mm, 1.3 mm, and 1.6 mm. CPD and controls differed significantly for the left/right movement of the rami (p = 0.04) but not for the other directions or rotations (p > 0.05). CONCLUSIONS: The results demonstrate that both methods are accurate, and postoperative results matched the virtually planned position precisely. It can be assumed that the described CPDs are beneficial when a condylar position different from the preoperative is desired.

2.
J Stomatol Oral Maxillofac Surg ; 125(3): 101725, 2023 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-38048907

RESUMEN

INTRODUCTION: The aim of the study was to investigate the impact of different aminopenicillin administration routes on the antimicrobial effects of platelet-rich fibrin (PRF). METHODS: We enrolled patients undergoing treatment with amoxicillin/clavulanic acid (AMC) orally or ampicillin/sulbactam (SAM) intravenously. AMC was applied in a single oral dose (875/125 mg), or in a double oral dose (1750/250 mg), and SAM in a dose of 2000/1000 mg. Blood was obtained one hour after the intake of AMC or 15 min after the infusion of SAM ended. Antimicrobial effects were investigated in agar diffusion tests with fresh PRF, PRF stored for 24, and PRF stored for 48 h. Agar diffusion tests were performed with Escherichia coli, Staphylococcus aureus, Streptococcus pneumoniae, Haemophilus influenzae, and Porphyromonas gingivalis. Inhibition zones (IZs) around a 6 mm PRF disc were measured after 24 h. RESULTS: IZs for fresh PRF and the single oral dose of AMC were 0.0, 4.7, 15.2, 2.3, and 0.9 mm (E. coli, S. aureus, S. pneumoniae, H. influenzae, and P. gingivalis, respectively). For the double oral dose, these values were 0.0, 11.4, 20.0, 8.1, and 7.4 mm. IZs for SAM were 11.9, 18.2, 24.7, 20.3, and 22.1 mm. Differences between parenteral and oral application as well as between different oral doses were significant (p<0.0001, one-way ANOVA). DISCUSSION: The results of our study demonstrate that oral administration is a suitable route to load PRF with these drugs. This could expand the scope of PRF application to prevent infections at the surgical site, especially in an outpatient setting in which drugs are normally applied orally.

3.
Front Surg ; 10: 1321217, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38162091

RESUMEN

Objective: This study aims to critically evaluate the effectiveness and accuracy of a time safing and cost-efficient open-source algorithm for in-house planning of mandibular reconstructions using the free osteocutaneous fibula graft. The evaluation focuses on quantifying anatomical accuracy and assessing the impact on ischemia time. Methods: A pilot study was conducted, including patients who underwent in-house planned computer-aided design and manufacturing (CAD/CAM) of free fibula flaps between 2021 and 2023. Out of all patient cases, we included all with postoperative 3D imaging in the study. The study utilized open-source software tools for the planning step, and three-dimensional (3D) printing techniques. The Hausdorff distance and Dice coefficient metrics were used to evaluate the accuracy of the planning procedure. Results: The study assessed eight patients (five males and three females, mean age 61.75 ± 3.69 years) with different diagnoses such as osteoradionecrosis and oral squamous cell carcinoma. The average ischemia time was 68.38 ± 27.95 min. For the evaluation of preoperative planning vs. the postoperative outcome, the mean Hausdorff Distance was 1.22 ± 0.40. The Dice Coefficients yielded a mean of 0.77 ± 0.07, suggesting a satisfactory concordance between the planned and postoperative states. Dice Coefficient and Hausdorff Distance revealed significant correlations with ischemia time (Spearman's rho = -0.810, p = 0.015 and Spearman's rho = 0.762, p = 0.028, respectively). Linear regression models adjusting for disease type further substantiated these findings. Conclusions: The in-house planning algorithm not only achieved high anatomical accuracy, as reflected by the Dice Coefficients and Hausdorff Distance metrics, but this accuracy also exhibited a significant correlation with reduced ischemia time. This underlines the critical role of meticulous planning in surgical outcomes. Additionally, the algorithm's open-source nature renders it cost-efficient, easy to learn, and broadly applicable, offering promising avenues for enhancing both healthcare affordability and accessibility.

4.
Int J Prosthodont ; 31(5): 451-452, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30180229

RESUMEN

PURPOSE: To evaluate the load at fracture and influence of artificial aging of posterior teeth occlusal veneers ("table tops") made of two different ceramics. MATERIALS AND METHODS: A total of 80 table tops were produced from feldspathic ceramic (VM) and zirconia-reinforced lithium silicate ceramic (CD) using computer-aided design/computer-assisted manufacturing (CAD/CAM). Half of the specimens from each ceramic were aged prior to the load test. RESULTS: Mean ± standard deviation (SD) load at fracture was significantly higher for CD (1,571.1 N ± 297.0 N) than for VM (573.6 N ± 86.4 N) (P < .001). After aging, load at fracture increased significantly to 1,819.0 N (± 310.6 N) for CD and to 745.2 N (± 168.3 N) for VM. CONCLUSION: The use of zirconia-reinforced lithium silicate ceramic for molar nonprep table tops should be uncomplicated according to the high load-at-fracture values. Mechanical stability of either ceramic is not compromised by aging.