Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
1.
Lancet Digit Health ; 6(3): e201-e210, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38395540

RESUMEN

BACKGROUND: Unwitnessed out-of-hospital cardiac arrest is associated with low survival chances because of the delayed activation of the emergency medical system in most cases. Automated cardiac arrest detection and alarming using biosensor technology would offer a potential solution to provide early help. We developed and validated an algorithm for automated circulatory arrest detection using wrist-derived photoplethysmography from patients with induced circulatory arrests. METHODS: In this prospective multicentre study in three university medical centres in the Netherlands, adult patients (aged 18 years or older) in whom short-lasting circulatory arrest was induced as part of routine practice (transcatheter aortic valve implantation, defibrillation testing, or ventricular tachycardia induction) were eligible for inclusion. Exclusion criteria were a known bilateral significant subclavian artery stenosis or medical issues interfering with the wearing of the wristband. After providing informed consent, patients were equipped with a photoplethysmography wristband during the procedure. Invasive arterial blood pressure and electrocardiography were continuously monitored as the reference standard. Development of the photoplethysmography algorithm was based on three consecutive training cohorts. For each cohort, patients were consecutively enrolled. When a total of 50 patients with at least one event of circulatory arrest were enrolled, that cohort was closed. Validation was performed on the fourth set of included patients. The primary outcome was sensitivity for the detection of circulatory arrest. FINDINGS: Of 306 patients enrolled between March 14, 2022, and April 21, 2023, 291 patients were included in the data analysis. In the development phase (n=205), the first training set yielded a sensitivity for circulatory arrest detection of 100% (95% CI 94-100) and four false positive alarms; the second training set yielded a sensitivity of 100% (94-100), with six false positive alarms; and the third training set yielded a sensitivity of 100% (94-100), with two false positive alarms. In the validation phase (n=86), the sensitivity for circulatory arrest detection was 98% (92-100) and 11 false positive circulatory arrest alarms. The positive predictive value was 90% (95% CI 82-94). INTERPRETATION: The automated detection of induced circulatory arrests using wrist-derived photoplethysmography is feasible with good sensitivity and low false positives. These promising findings warrant further development of this wearable technology to enable automated cardiac arrest detection and alarming in a home setting. FUNDING: Dutch Heart Foundation (Hartstichting).


Asunto(s)
Paro Cardíaco , Fotopletismografía , Adulto , Humanos , Estudios Prospectivos , Paro Cardíaco/diagnóstico , Arritmias Cardíacas , Algoritmos
2.
Cardiol J ; 29(5): 739-750, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35912711

RESUMEN

BACKGROUND: Ion channel inhibition may offer protection against coronavirus disease 2019 (COVID-19). Inflammation and reduced platelet count occur during COVID-19 but precise quantification of risk thresholds is unclear. The Recov ery-SIRIO study aimed to assess clinical effects of amiodarone and verapamil and to relate patient phenotypes to outcomes. METHODS: RECOVERY-SIRIO is a multicenter open-label 1:1:1 investigator-initiated randomized trial with blinded event adjudication. A sample of 804 symptomatic hospitalized nonintensive-care COVID-19 patients, follow-up for 28 days was initially planned. RESULTS: The trial was stopped when a total of 215 patients had been randomized to amiodarone (n = 71), verapamil (n = 72) or standard care alone (n = 72). At 15 days, the hazard ratio (hazard ratio [HR], 95% confidence interval [CI]) for clinical improvement was 0.77 (0.52-1.14) with amiodarone and 0.97 (0.81-1.17) with verapamil as compared to usual care. Clinically relevant associations were found between mortality or lack of clinical improvement and higher peak C-reactive protein (CRP) levels or nadir platelet count at 7, 10 and 15 days. Mortality rate increased by 73% every 5 mg/dL increment in peak CRP (HR 1.73, 95% CI 1.27-2.37) and was two-fold higher for every decrement of 100 units in nadir platelet count (HR 2.19, 95% CI 1.37-3.51). By cluster analysis, thresholds of 5 mg/dL for peak CRP and 187 × 103/mcL for nadir platelet count identified the phenogroup at greatest risk of dying. CONCLUSIONS: In this randomized trial, neither amiodarone nor verapamil were found to significantly accelerate short-term clinical improvement. Peak CRP and nadir platelet counts were associated with increased mortality both in isolation and by cluster analysis.


Asunto(s)
Amiodarona , COVID-19 , Amiodarona/uso terapéutico , Proteína C-Reactiva , Carbidopa , Combinación de Medicamentos , Humanos , Canales Iónicos , Levodopa/análogos & derivados , SARS-CoV-2 , Verapamilo/uso terapéutico
3.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-36030464

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Humanos , Resultado del Tratamiento , Desfibriladores Implantables/efectos adversos
4.
JAMA Netw Open ; 5(5): e2212964, 2022 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-35587346

RESUMEN

Importance: Increased bystander cardiopulmonary resuscitation (CPR) is essential to improve survival after cardiac arrest. Although most studies focus on technical CPR skills, the randomized Lowlands Saves Lives trial prespecified a follow-up survey on other important aspects that affect the widespread performance of CPR. Objective: To investigate bystander willingness to perform CPR on a stranger, theoretical knowledge retention, and dissemination of CPR awareness 6 months after undergoing short face-to-face and virtual reality (VR) CPR trainings. Design, Setting, and Participants: A prespecified 6-month posttraining survey was conducted among 320 participants in the Lowlands Saves Lives trial, a randomized comparison between 20-minute face-to-face, instructor-led CPR training and VR training. Participants were recruited at the Lowlands music festival, with a designated area to conduct scientific projects (August 16-18, 2019; the Netherlands). Statistical analysis was performed from March 1, 2020, to July 31, 2021. Interventions: Two standardized 20-minute protocols on CPR and automated external defibrillator use: instructor-led face-to-face training using CPR manikins or VR training using the Resuscitation Council (UK)-endorsed Lifesaver VR smartphone application and a pillow to practice compressions. Main Outcomes and Measures: Primary outcomes were willingness to perform CPR on a stranger, theoretical knowledge retention, and dissemination of CPR awareness as reported by the entire cohort. As secondary analyses, the results of the 2 training modalities were compared. Results: Of 381 participants, 320 consented to this follow-up survey; 188 participants (115 women [61%]; median age, 26 years [IQR, 22-32 years]) completed the entire survey and were accordingly included in the secondary analysis. The overall proportion of participants willing to perform CPR on a stranger was 77% (144 of 188): 81% (79 of 97) among face-to-face participants and 71% (65 of 91) among VR participants (P = .02); 103 participants (55%) reported feeling scared to perform CPR (P = .91). Regarding theoretical knowledge retention, a median of 7 (IQR, 6-8) of 9 questions were answered correctly in both groups (P = .81). Regarding dissemination of CPR awareness, 65% of participants (123 of 188) told at least 1 to 10 family members or friends about the importance of CPR, and 15% (29 of 188) had participated in certified, instructor-led training at the time of the survey, without differences between groups. Conclusions and Relevance: In this 6-month posttraining survey, young adult participants of short CPR training modules reported high willingness (77%) to perform CPR on a stranger, with slightly higher rates for face-to-face than for VR participants. Theoretical knowledge retention was good, and the high dissemination of awareness suggests that these novel CPR training modules staged at a public event are promising sensitizers for involvement in CPR, although further challenges include mitigating the fear of performing CPR. Trial Registration: ClinicalTrials.gov Identifier: NCT04013633.


Asunto(s)
Reanimación Cardiopulmonar , Paro Cardíaco , Realidad Virtual , Adulto , Reanimación Cardiopulmonar/métodos , Desfibriladores , Femenino , Paro Cardíaco/terapia , Humanos , Encuestas y Cuestionarios , Adulto Joven
5.
Resuscitation ; 174: 62-67, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35351606

RESUMEN

INTRODUCTION: On-scene detection of acute coronary occlusion (ACO) during ongoing ventricular fibrillation (VF) may facilitate patient-tailored triage and treatment during cardiac arrest. Experimental studies have demonstrated the diagnostic potential of the amplitude spectrum area (AMSA) of the VF-waveform to detect myocardial infarction (MI). In follow-up, we performed this clinical pilot study on VF-waveform based discriminative models to diagnose acute MI due to ACO in real-world VF-patients. METHODS: In our registry of VF-patients transported to a tertiary hospital (Nijmegen, The Netherlands), we studied patients with high-quality VF-registrations. We calculated VF-characteristics prior to the first shock, and first-to-second shock changes (Δ-characteristics). Primary aim was to assess the discriminative ability of the AMSA to detect patients with ACO. Secondarily, we investigated the discriminative value of adding ΔAMSA-measures using machine learning algorithms. Model performances were assessed using C-statistics. RESULTS: In total, there were 67 VF-patients with and 34 without an ACO, and baseline characteristics did not differ significantly. Based on the AMSA prior to the first defibrillation attempt, discrimination between ACO and non-ACO was possible, with a C-statistic of 0.66 (0.56-0.75). The discriminative model using AMSA + ΔAMSA yielded a C-statistic of 0.80 (0.69-0.88). CONCLUSION: These clinical pilot data confirm previous experimental findings that early detection of MI using VF-waveform analysis seems feasible, and add insights on the diagnostic impact of accounting for first-to-second shock changes in VF-characteristics. Confirmative studies in larger cohorts and with a variety of VF-algorithms are warranted to further investigate the potential of this innovative approach.


Asunto(s)
Reanimación Cardiopulmonar , Infarto del Miocardio , Paro Cardíaco Extrahospitalario , Algoritmos , Amsacrina , Cardioversión Eléctrica , Electrocardiografía , Humanos , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico , Paro Cardíaco Extrahospitalario/diagnóstico , Paro Cardíaco Extrahospitalario/etiología , Paro Cardíaco Extrahospitalario/terapia , Proyectos Piloto , Fibrilación Ventricular/complicaciones , Fibrilación Ventricular/diagnóstico
6.
J Interv Card Electrophysiol ; 64(1): 9-16, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33629193

RESUMEN

BACKGROUND: Catheter ablation for persistent atrial fibrillation (persAF) is associated with less favorable outcomes than for paroxysmal AF. To improve success rates, left atrial (LA) substrate modification is frequently performed in addition to pulmonary vein isolation (PVI). The purpose of the study was to compare 4 different ablation approaches using radiofrequency catheter ablation (RFCA) or cryoballoon ablation (CB-A) for persAF and to evaluate the respective outcomes on a midterm follow-up of 12 months. METHODS: We did a propensity score-matched comparison of 30 patients undergoing PVI + LA posterior wall isolation (LAPWI) with CB-A, 30 patients who underwent PVI + linear ablation (roof and mitral lines) using RFCA, 60 patients with PVI alone using CB-A, and 60 patients who had PVI alone using RFCA. The endpoint was recurrence of documented atrial tachyarrhythmias (ATas) > 30 s at 1-year follow-up. RESULTS: After 12 months, freedom from ATas after a single procedure was 83.3% in the PVI + LAPWI group, 46.7% in the PVI + linear ablation group, 58.3% in the PVI-alone CB-A group, and 61.6% PVI-alone RFCA (p = 0.03). Moreover, freedom from ATas was significantly higher comparing the PVI + LAPWI group with each of the other groups. CONCLUSIONS: In this propensity-matched comparison of strategies for persAF, LAPW ablation in addition to PVI with CB-A seems to improve 1-year outcome in comparison to PVI + linear ablation using RFCA and to PVI alone using RFCA or CB-A. Randomized comparisons are eagerly awaited.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/métodos , Humanos , Puntaje de Propensión , Venas Pulmonares/cirugía , Recurrencia , Taquicardia/cirugía , Resultado del Tratamiento
7.
Circulation ; 145(5): 321-329, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34779221

RESUMEN

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables/normas , Anciano , Arritmias Cardíacas/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
8.
Europace ; 23(12): 1961-1969, 2021 12 07.
Artículo en Inglés | MEDLINE | ID: mdl-34333631

RESUMEN

AIMS: At present, there are no guideline recommendations for minimally interrupted use of non-vitamin K antagonist oral anticoagulants (mi-NOAC) during catheter ablation (CA) for atrial fibrillation (AF). Current evidence is predominantly based on observational studies, with continuous use of vitamin K antagonist in the control arm. This quantitative summary reflects the first high-level evidence on contemporary regimens, with continuous NOAC use (c-NOAC) as the current gold standard. METHODS AND RESULTS: Meta-analysis (Pubmed, Embase, and Web of Science) on prospective, controlled studies comparing contemporary mi-NOAC (without bridging) with c-NOAC. Net adverse clinical events (major bleeding, thrombo-embolic events) were the primary outcome. In addition, we analysed total bleeding, minor bleeding, and silent cerebral embolism. Eight studies (six randomized, two observational) with 2168 patients were summarized. The primary endpoint occurred in 1.0% (18/1835): 1.1% (11/1005) vs. 0.8% (7/830) for the mi-NOAC and c-NOAC groups, respectively; odds ratio (OR) 1.20 [95% confidence interval (CI) 0.49-2.92, P = 0.64]. The OR for total bleeding on mi-NOAC was 1.26 (95% CI 0.97-1.63, P = 0.07). ORs for minor bleeding and silent cerebral embolism were 1.17 (95% CI 0.80-1.70, P = 0.34) and 2.62 (95% CI 0.54-12.61, P = 0.12), respectively. CONCLUSION: This synopsis provides a quantitative synthesis of high-level evidence on a contemporary strategy of mi-NOAC in CA for AF, and overall clinical outcomes were not different from continuous NOAC use. Despite preprocedural interruption, there was no sign of lower bleeding rates. Additional higher volume datasets are warranted for more precise treatment effect estimations of this everyday alternative anticoagulation strategy in AF ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Administración Oral , Anticoagulantes/efectos adversos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Vitamina K
9.
Resusc Plus ; 6: 100114, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34223374

RESUMEN

AIM: In cardiac arrest, ventricular fibrillation (VF) waveform analysis has identified the amplitude spectrum area (AMSA) as a key predictor of defibrillation success and favorable neurologic survival. New resuscitation protocols are under investigation, where prompt defibrillation is restricted to cases with a high AMSA. Appreciating the variability of in-field pad placement, we aimed to assess the impact of recording direction on AMSA-values, and the inherent defibrillation advice. METHODS: Prospective VF-waveform study on 12-lead surface electrocardiograms (ECGs) obtained during defibrillation testing in ICD-recipients (2010-2017). AMSA-values (mVHz) of simultaneous VF-recordings were calculated and compared between all limb leads, with lead II as reference (proxy for in-field pad position). AMSA-differences between leads I and II were quantified using Bland-Altman analysis. Moreover, we investigated differences between these adjacent leads regarding classification into high (≥15.5), intermediate (6.5-15.5) or low (≤6.5) AMSA-values. RESULTS: In this cohort (n = 243), AMSA-values in lead II (10.2 ± 4.8) differed significantly from the other limb leads (I: 8.0 ± 3.4; III: 12.9 ± 5.6, both p < 0.001). The AMSA-value in lead I was, on average, 2.24 ± 4.3 lower than in lead II. Of the subjects with high AMSA-values in lead II, only 15% were classified as high if based on assessments of lead I. For intermediate and low AMSA-values, concordances were 66% and 72% respectively. CONCLUSIONS: ECG-recording direction markedly affects the result of VF-waveform analysis, with 20-30% lower AMSA-values in lead I than in lead II. Our data suggest that electrode positioning may significantly impact shock guidance by 'smart defibrillators', especially affecting the advice for prompt defibrillation.

10.
Am J Cardiol ; 152: 120-124, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-34130823

RESUMEN

Since the first report of an association between cardiac troponin (cTn) and adverse outcome in hypertrophic cardiomyopathy (HD), there is a paucity in confirmative data. We performed a prospective, prespecified 5-year follow-up cohort study of 135 HC patients who participated in a national multicenter project and underwent clinical evaluation, MRI (cine, LGE and T2-weighted imaging) and biomarker assessment (high-sensitivity cTnT (hs-cTnT), N-terminal pro-B-type natriuretic peptide, soluble tumorgenicity suppressor-2, Galectin-3, Growth differentiation factor-15, C-terminal Propeptide of Type I Collagen (CICP)). An elevated hs-cTnT concentration was defined as ≥14ng/L. Follow-up was systematically performed for the primary endpoint: a composite of sudden cardiac death, heart failure related death, stroke-related death, heart failure hospitalization, hospitalization for stroke, spontaneous sustained ventricular tachycardia (VT) or appropriate ICD discharge, and progression to NYHA class III-IV. Elevated hs-cTnT was present in 33 of 135 (24%) HC patients. During a median follow-up of 5.0 years (IQR: 4.9-5.1) 18 patients reached the primary endpoint. Using Cox regression analysis, elevated hs-cTnT was univariately associated with the primary endpoint (HR: 3.4 (95%CI: 1.4-8.7, p=0.009). Also female sex, previous syncope, previous non-sustained VT, reduced LV ejection fraction (<50%) and CICP were associated with the primary endpoint. In multivariable analysis, elevated hs-cTnT remained independently associated with outcome (aHR: 4.7 (95%CI: 1.8-12.6, p = 0.002). In conclusion, this 5-year follow-up study is the first to prospectively confirm the association of elevated hs-cTnT and adverse outcomes. In addition to established clinical variables, cTn seems the biomarker of interest to further improve risk prediction in HC, which should be evaluated in larger prospective registries.


Asunto(s)
Cardiomiopatía Hipertrófica/sangre , Muerte Súbita Cardíaca/epidemiología , Insuficiencia Cardíaca/mortalidad , Taquicardia Ventricular/epidemiología , Troponina T/sangre , Anciano , Proteínas Sanguíneas , Estudios de Cohortes , Desfibriladores Implantables , Cardioversión Eléctrica/estadística & datos numéricos , Femenino , Estudios de Seguimiento , Galectinas/sangre , Factor 15 de Diferenciación de Crecimiento/sangre , Hospitalización/estadística & datos numéricos , Humanos , Proteína 1 Similar al Receptor de Interleucina-1/sangre , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Procolágeno/sangre , Pronóstico , Estudios Prospectivos , Accidente Cerebrovascular/mortalidad , Taquicardia Ventricular/terapia
12.
Eur Heart J ; 42(45): 4638-4651, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34002203

RESUMEN

AIMS: The value of elective coronary revascularisation plus medical therapy over medical therapy alone in managing stable patients with coronary artery disease is debated. We reviewed all trials comparing the two strategies in this population. METHODS AND RESULTS: From inception through November 2020, MEDLINE, EMBASE, Google Scholar, and other databases were searched for randomised trials comparing revascularisation against medical therapy alone in clinically stable coronary artery disease patients. Treatment effects were measured by rate ratios (RRs) with 95% confidence intervals, using random-effects models. Cardiac mortality was the pre-specified primary endpoint. Spontaneous myocardial infarction (MI) and its association with cardiac mortality were secondary endpoints. Further endpoints included all-cause mortality, any MI, and stroke. Longest follow-up data were abstracted. The study is registered with PROSPERO (CRD42021225598). Twenty-five trials involving 19 806 patients (10 023 randomised to revascularisation plus medical therapy and 9783 to medical therapy alone) were included. Compared with medical therapy alone, revascularisation yielded a lower risk of cardiac death [RR 0.79 (0.67-0.93), P < 0.01] and spontaneous MI [RR 0.74 (0.64-0.86), P < 0.01]. By meta-regression, the cardiac death risk reduction after revascularisation, compared with medical therapy alone, was linearly associated with follow-up duration [RR per 4-year follow-up: 0.81 (0.69-0.96), P = 0.008], spontaneous MI absolute difference (P = 0.01) and percentage of multivessel disease at baseline (P = 0.004). Trial sequential and sensitivity analyses confirmed the reliability of the cardiac mortality findings. All-cause mortality [0.94 (0.87-1.01), P = 0.11], any MI (P = 0.14), and stroke risk (P = 0.30) did not differ significantly between strategies. CONCLUSION: In stable coronary artery disease patients, randomisation to elective coronary revascularisation plus medical therapy led to reduced cardiac mortality compared with medical therapy alone. The cardiac survival benefit after revascularisation improved with longer follow-up times and was associated with fewer spontaneous MIs.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Causas de Muerte , Enfermedad de la Arteria Coronaria/terapia , Humanos , Infarto del Miocardio/terapia , Revascularización Miocárdica , Ensayos Clínicos Controlados Aleatorios como Asunto , Reproducibilidad de los Resultados
13.
Atherosclerosis ; 321: 39-44, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33639478

RESUMEN

BACKGROUND AND AIMS: The impact of advanced age on the optimal duration of dual antiplatelet therapy (DAPT) in patients with acute coronary syndrome (ACS) undergoing percutaneous coronary revascularization (PCI) is still greatly debated. Therefore, the aim of the present sub-analysis of the REDUCE trial was to assess the impact of age on the comparison between a short 3 months vs standard 12 months DAPT in ACS patients treated with the COMBO Dual Stent Therapy. METHODS: The REDUCE trial is a prospective, multicenter, investigator-initiated study that randomized ACS patients undergoing PCI with the COMBO drug eluting stent to either 3 or 12 months of DAPT. The study population was divided according to age (

Asunto(s)
Síndrome Coronario Agudo , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/tratamiento farmacológico , Anciano , Preescolar , Quimioterapia Combinada , Estudios de Seguimiento , Humanos , Lactante , Masculino , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Estudios Prospectivos , Stents , Resultado del Tratamiento
14.
Europace ; 23(6): 887-897, 2021 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-33582797

RESUMEN

AIMS: This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation. METHODS AND RESULTS: We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively. Between 2014 and 2018, we included 1441 consecutive patients in the development and 1450 patients in the validation cohort. During a median follow-up of 2.4 (IQR 2.1-2.8) years, 109 (7.6%) patients received appropriate ICD shock and 193 (13.4%) died in the development cohort. During a median follow-up of 2.7 (IQR 2.0-3.4) years, 105 (7.2%) received appropriate ICD shock and 223 (15.4%) died in the validation cohort. Selected predictors of appropriate ICD shock were gender, NSVT, ACE/ARB use, atrial fibrillation history, Aldosterone-antagonist use, Digoxin use, eGFR, (N)OAC use, and peripheral vascular disease. Selected predictors of all-cause mortality were age, diuretic use, sodium, NT-pro-BNP, and ACE/ARB use. C-statistic was 0.61 and 0.60 at respectively internal and external validation for appropriate ICD shock and 0.74 at both internal and external validation for mortality. CONCLUSION: Although this cohort study was specifically designed to develop prediction models, risk stratification still remains challenging and no large group with insufficient benefit of ICD implantation was found. However, the prediction models have some clinical utility as we present several scenarios where ICD implantation might be postponed.


Asunto(s)
Desfibriladores Implantables , Antagonistas de Receptores de Angiotensina , Inhibidores de la Enzima Convertidora de Angiotensina , Estudios de Cohortes , Muerte Súbita Cardíaca/prevención & control , Humanos , Prevención Primaria , Factores de Riesgo
15.
J Am Heart Assoc ; 10(2): e017367, 2021 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-33442988

RESUMEN

Background Dissemination of cardiopulmonary resuscitation (CPR) skills is essential for cardiac arrest survival. Virtual reality (VR)-training methods are low cost and easily available, but to meet depth requirements adaptations are required, as confirmed in a recent randomized study on currently prevailing CPR quality criteria. Recently, the promising clinical performance of new CPR quality criteria was demonstrated, based on the optimal combination of compression depth and rate. We now study compliance with these newly proposed CPR quality criteria. Methods and Results Post hoc analysis of a randomized trial compared standardized 20-minute face-to-face CPR training with VR training using the Lifesaver VR smartphone application. During a posttraining test, compression depth and rate were measured using CPR mannequins. We assessed compliance with the newly proposed CPR criteria, that is, compression rate within ±20% of 107/minute and depth within ±20% of 47 mm. We studied 352 participants, age 26 (22-31) years, 56% female, and 15% with CPR training ≤2 years. Among VR-trained participants, there was a statistically significant difference between the proportions complying with newly proposed versus the currently prevailing quality criteria (52% versus 23%, P<0.001). The difference in proportions complying with rate requirements was statistically significant (96% for the new versus 50% for current criteria, P<0.001), whereas there was no significant difference with regard to the depth requirements (55% versus 51%, P=0.45). Conclusions Lifesaver VR training, although previously found to be inferior to face-to-face training, may lead to CPR quality compliant with recently proposed, new quality criteria. If the prognostic importance of these new criteria is confirmed in additional studies, Lifesaver VR in its current form would be an easily available vector to disseminate CPR skills.


Asunto(s)
Reanimación Cardiopulmonar/métodos , Educación , Educación en Salud/métodos , Paro Cardíaco/terapia , Masaje Cardíaco/métodos , Realidad Virtual , Adulto , Educación/métodos , Educación/normas , Femenino , Humanos , Masculino , Aplicaciones Móviles , Evaluación de Resultado en la Atención de Salud , Teléfono Inteligente
16.
Clin Chem ; 67(1): 227-236, 2021 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-33418572

RESUMEN

BACKGROUND: Troponin composition characterization has been implicated as a next step to differentiate among non-ST elevation myocardial infarction (NSTEMI) patients and improve distinction from other conditions with troponin release. We therefore studied coronary and peripheral troponin compositions in relation to clinical variables of NSTEMI patients. METHODS: Samples were obtained from the great cardiac vein (GCV), coronary sinus (CS), and peripheral circulation of 45 patients with NSTEMI. We measured total cTnI concentrations, and assessed both complex cTnI (binary cTnIC + all ternary cTnTIC forms), and large-size cTnTIC (full-size and partially truncated cTnTIC). Troponin compositions were studied in relation to culprit vessel localization (left anterior descending artery [LAD] or non-LAD), ischemic time window, and peak CK-MB value. RESULTS: Sampling occurred at a median of 25 hours after symptom onset. Of total peripheral cTnI, a median of 87[78-100]% consisted of complex cTnI; and 9[6-15]% was large-size cTnTIC. All concentrations (total, complex cTnI, and large-size cTnTIC) were significantly higher in the CS than in peripheral samples (P < 0.001). For LAD culprit patients, GCV concentrations were all significantly higher; in non-LAD culprit patients, CS concentrations were higher. Proportionally, more large-size cTnTIC was present in the earliest sampled patients and in those with the highest CK-MB peaks. CONCLUSIONS: In coronary veins draining the infarct area, concentrations of both full-size and degraded troponin were higher than in the peripheral circulation. This finding, and the observed associations of troponin composition with the ischemic time window and the extent of sustained injury may contribute to future characterization of different disease states among NSTEMI patients.


Asunto(s)
Infarto del Miocardio sin Elevación del ST/metabolismo , Troponina C/metabolismo , Troponina I/metabolismo , Troponina T/metabolismo , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Biomarcadores/metabolismo , Seno Coronario/irrigación sanguínea , Femenino , Humanos , Masculino , Infarto del Miocardio sin Elevación del ST/sangre , Flujo Sanguíneo Regional , Índice de Severidad de la Enfermedad , Factores de Tiempo , Troponina C/sangre , Troponina I/sangre , Troponina T/sangre
18.
JACC Cardiovasc Interv ; 13(21): 2453-2466, 2020 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-33153562

RESUMEN

Patients who undergo transcatheter aortic valve replacement often are frail and elderly. Delirium is a frequently observed complication, associated with impaired recovery, prolonged hospital stay, and mortality. In different hospital settings, interventions that reduced the incidence of delirium resulted in improved clinical outcome and reduced costs. In that context, prevention, early recognition, and timely interventions could be the next step toward better outcomes of transcatheter aortic valve replacement. This review is focused on awareness and recognition of delirium, including predisposing "vulnerability" factors (such as cognitive impairment and carotid artery disease) and "trigger" factors (such as anesthesia, hemodynamic imbalance, and complications). For prevention and treatment, clinicians should focus on sleep hygiene, orientation, pain management, and early mobilization. In case of delirium, a thorough search and treatment of trigger factors is warranted. Future studies should focus on risk assessment, preventive and therapeutic interventions, and their potential benefit in terms of costs and clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Delirio , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Delirio/etiología , Humanos , Complicaciones Posoperatorias , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...