Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
Diagnostics (Basel) ; 14(4)2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38396455

RESUMEN

BACKGROUND: In metastatic breast cancer (MBC), [18F]fluorodeoxyglucose positron emission tomography/computed tomography ([18F]FDG-PET/CT) can be used for staging. We evaluated the correlation between BC histopathological characteristics and [18F]FDG uptake in corresponding metastases. PATIENTS AND METHODS: Patients with non-rapidly progressive MBC of all subtypes prospectively underwent a baseline histological metastasis biopsy and [18F]FDG-PET. Biopsies were assessed for estrogen, progesterone, and human epidermal growth factor receptor 2 (ER, PR, HER2); Ki-67; and histological subtype. [18F]FDG uptake was expressed as maximum standardized uptake value (SUVmax) and results were expressed as geometric means. RESULTS: Of 200 patients, 188 had evaluable metastasis biopsies, and 182 of these contained tumor. HER2 positivity and Ki-67 ≥ 20% were correlated with higher [18F]FDG uptake (estimated geometric mean SUVmax 10.0 and 8.8, respectively; p = 0.0064 and p = 0.014). [18F]FDG uptake was lowest in ER-positive/HER2-negative BC and highest in HER2-positive BC (geometric mean SUVmax 6.8 and 10.0, respectively; p = 0.0058). Although [18F]FDG uptake was lower in invasive lobular carcinoma (n = 31) than invasive carcinoma NST (n = 146) (estimated geometric mean SUVmax 5.8 versus 7.8; p = 0.014), the metastasis detection rate was similar. CONCLUSIONS: [18F]FDG-PET is a powerful tool to detect metastases, including invasive lobular carcinoma. Although BC histopathological characteristics are related to [18F]FDG uptake, [18F]FDG-PET and biopsy remain complementary in MBC staging (NCT01957332).

2.
NPJ Breast Cancer ; 10(1): 4, 2024 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-38184611

RESUMEN

Efficacy of the human epidermal growth factor receptor (HER)2-targeting trastuzumab emtansine (T-DM1) in breast cancer (BC) relies on HER2 status determined by immunohistochemistry or fluorescence in-situ hybridization. Heterogeneity in HER2 expression, however, generates interest in "whole-body" assessment of HER2 status using molecular imaging. We evaluated the role of HER2-targeted molecular imaging in detecting HER2-positive BC lesions and patients unlikely to respond to T-DM1. Patients underwent zirconium-89 (89Zr) trastuzumab (HER2) PET/CT and [18F]-2-fluoro-2-deoxy-D-glucose (FDG) PET/CT before T-DM1 initiation. Based on 89Zr-trastuzumab uptake, lesions were visually classified as HER2-positive (visible/high uptake) or HER2-negative (background/close to background activity). According to proportion of FDG-avid tumor load showing 89Zr-trastuzumab uptake (entire/dominant part or minor/no part), patients were classified as HER2-positive and HER2-negative, respectively. Out of 265 measurable lesions, 93 (35%) were HER2-negative, distributed among 42 of the 90 included patients. Of these, 18 (19%) lesions belonging to 11 patients responded anatomically (>30% decrease in axial diameter from baseline) after three T-DM1 cycles, resulting in an 81% negative predictive value (NPV) of the HER2 PET/CT. In combination with early metabolic response assessment on FDG PET/CT performed before the second T-DM1 cycle, NPVs of 91% and 100% were reached in predicting lesion-based and patient-based (RECIST1.1) response, respectively. Therefore, HER2 PET/CT, alone or in combination with early FDG PET/CT, can successfully identify BC lesions and patients with a low probability of clinical benefit from T-DM1.

3.
Eur J Nucl Med Mol Imaging ; 51(4): 1050-1059, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37975887

RESUMEN

PURPOSE: Accurate preoperative localization is imperative to guide surgery in primary hyperparathyroidism (pHPT). It remains unclear which second-line imaging technique is most effective after negative first-line imaging. In this study, we compare the diagnostic effectiveness of [11C]methionine PET/CT, [11C]choline PET/CT, and four dimensional (4D)-CT head-to-head in patients with pHPT, to explore which of these imaging techniques to use as a second-line scan. METHODS: We conducted a powered, prospective, blinded cohort study in patients with biochemically proven pHPT and prior negative or discordant first-line imaging consisting of ultrasonography and 99mTc-sestamibi. All patients underwent [11C]methionine PET/CT, [11C]choline PET/CT, and 4D-CT. At first, all scans were interpreted by a nuclear medicine physician, and a radiologist who were blinded from patient data and all imaging results. Next, a non-blinded scan reading was performed. The scan results were correlated with surgical and histopathological findings. Serum calcium values at least 6 months after surgery were used as gold standard for curation of HPT. RESULTS: A total of 32 patients were included in the study. With blinded evaluation, [11C]choline PET/CT was positive in 28 patients (88%), [11C]methionine PET/CT in 23 (72%), and 4D-CT in 15 patients (47%), respectively. In total, 30 patients have undergone surgery and 32 parathyroid lesions were histologically confirmed as parathyroid adenomas. Based on the blinded evaluation, lesion-based sensitivity of [11C]choline PET/CT, [11C]methionine PET/CT, and 4D-CT was respectively 85%, 67%, and 39%. The sensitivity of [11C]choline PET/CT differed significantly from that of [11C]methionine PET/CT and 4D-CT (p = 0.031 and p < 0.0005, respectively). CONCLUSION: In the setting of pHPT with negative first-line imaging, [11C]choline PET/CT is superior to [11C]methionine PET/CT and 4D-CT in localizing parathyroid adenomas, allowing correct localization in 85% of adenomas. Further studies are needed to determine cost-benefit and efficacy of these scans, including the timing of these scans as first- or second-line imaging techniques.


Asunto(s)
Hiperparatiroidismo Primario , Neoplasias de las Paratiroides , Humanos , Neoplasias de las Paratiroides/complicaciones , Neoplasias de las Paratiroides/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Hiperparatiroidismo Primario/diagnóstico por imagen , Hiperparatiroidismo Primario/cirugía , Metionina , Colina , Estudios de Cohortes , Estudios Prospectivos , Glándulas Paratiroides , Tecnecio Tc 99m Sestamibi , Racemetionina
4.
Med Phys ; 51(1): 139-155, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38047554

RESUMEN

BACKGROUND: The use of computed tomography (CT) for attenuation correction (AC) in whole-body PET/CT can result in a significant contribution to radiation exposure. This can become a limiting factor for reducing considerably the overall radiation exposure of the patient when using the new long axial field of view (LAFOV) PET scanners. However, recent CT technology have introduced features such as the tin (Sn) filter, which can substantially reduce the CT radiation dose. PURPOSE: The purpose of this study was to investigate the ultra-low dose CT for attenuation correction using the Sn filter together with other dose reduction options such as tube current (mAs) reduction. We explore the impact of dose reduction in the context of AC-CT and how it affects PET image quality. METHODS: The study evaluated a range of ultra-low dose CT protocols using five physical phantoms that represented a broad collection of tissue electron densities. A long axial field of view (LAFOV) PET/CT scanner was used to scan all phantoms, applying various CT dose reduction parameters such as reducing tube current (mAs), increasing the pitch value, and applying the Sn filter. The effective dose resulting from the CT scans was determined using the CTDIVol reported by the scanner. Several voxel-based and volumes of interest (VOI)-based comparisons were performed to compare the ultra-low dose CT images, the generated attenuation maps, and corresponding PET images against those images acquired with the standard low dose CT protocol. Finally, two patient datasets were acquired using one of the suggested ultra-low dose CT settings. RESULTS: By incorporating the Sn filter and adjusting mAs to the lowest available value, the radiation dose in CT images of PBU-60 phantom was significantly reduced; resulting in an effective dose of nearly 2% compared to the routine low dose CT protocols currently in clinical use. The assessment of PET images using VOI and voxel-based comparisons indicated relative differences (RD%) of under 6% for mean activity concentration (AC) in the torso phantom and patient dataset and under 8% for a source point in the CIRS phantom. The maximum RD% value of AC was 14% for the point source in the CIRS phantom. Increasing the tube current from 6 mAs to 30 mAs in patients with high BMI, or with arms down, can suppress the photon starvation artifact, whilst still preserving a dose reduction of 90%. CONCLUSIONS: Introducing a Sn filter in CT imaging lowers radiation dose by more than 90%. This reduction has minimal effect on PET image quantification at least for patients without Body Mass Index (BMI) higher than 30. Notably, this study results need validation using a larger clinical PET/CT dataset in the future, including patients with higher BMI.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Tomógrafos Computarizados por Rayos X , Tomografía de Emisión de Positrones/métodos , Fantasmas de Imagen
5.
Cancers (Basel) ; 15(21)2023 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-37958347

RESUMEN

The latest technical development in the field of positron emission tomography/computed tomography (PET/CT) imaging has been the extension of the PET axial field-of-view. As a result of the increased number of detectors, the long axial field-of-view (LAFOV) PET systems are not only characterized by a larger anatomical coverage but also by a substantially improved sensitivity, compared with conventional short axial field-of-view PET systems. In clinical practice, this innovation has led to the following optimization: (1) improved overall image quality, (2) decreased duration of PET examinations, (3) decreased amount of radioactivity administered to the patient, or (4) a combination of any of the above. In this review, novel applications of LAFOV PET in oncology are highlighted and future directions are discussed.

6.
J Nucl Med ; 64(11): 1815-1820, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37536740

RESUMEN

The purpose of this study was to quantify any differences between the SUVs of 89Zr immuno-PET scans obtained using a PET/CT system with a long axial field of view (LAFOV; Biograph Vision Quadra) compared to a PET/CT system with a short axial field of view (SAFOV; Biograph Vision) and to evaluate how LAFOV PET scan duration affects image noise and SUV metrics. Methods: Five metastatic breast cancer patients were scanned consecutively on SAFOV and LAFOV PET/CT scanners. Four additional patients were scanned using only LAFOV PET/CT. Scans on both systems lasted approximately 30 min and were acquired 4 d after injection of 37 MBq of 89Zr-trastuzumab. LAFOV list-mode data were reprocessed to obtain images acquired using shorter scan durations (15, 10, 7.5, 5, and 3 min). Volumes of interest were placed in healthy tissues, and tumors were segmented semiautomatically to compare coefficients of variation and to perform Bland-Altman analysis on SUV metrics (SUVmax, SUVpeak, and SUVmean). Results: Using 30-min images, 2 commonly used lesion SUV metrics were higher for SAFOV than for LAFOV PET (SUVmax, 16.2% ± 13.4%, and SUVpeak, 10.1% ± 7.2%), whereas the SUVmean of healthy tissues showed minimal differences (0.7% ± 5.8%). Coefficients of variation in the liver derived from 30-min SAFOV PET were between those of 3- and 5-min LAFOV PET. The smallest SUVmax and SUVpeak differences between SAFOV and LAFOV were found for 3-min LAFOV PET. Conclusion: LAFOV 89Zr immuno-PET showed a lower SUVmax and SUVpeak than SAFOV because of lower image noise. LAFOV PET scan duration may be reduced at the expense of increasing image noise and bias in SUV metrics. Nevertheless, SUVpeak showed only minimal bias when reducing scan duration from 30 to 10 min.


Asunto(s)
Neoplasias de la Mama , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Femenino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Trastuzumab , Tomografía de Emisión de Positrones/métodos , Neoplasias de la Mama/diagnóstico por imagen
7.
Eur J Nucl Med Mol Imaging ; 50(9): 2736-2750, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37039901

RESUMEN

PURPOSE: Patient-tailored management of thyroid nodules requires improved risk of malignancy stratification by accurate preoperative nodule assessment, aiming to personalize decisions concerning diagnostics and treatment. Here, we perform an exploratory pilot study to identify possible patterns on multispectral optoacoustic tomography (MSOT) for thyroid malignancy stratification. For the first time, we directly correlate MSOT images with histopathology data on a detailed level. METHODS: We use recently enhanced data processing and image reconstruction methods for MSOT to provide next-level image quality by means of improved spatial resolution and spectral contrast. We examine optoacoustic features in thyroid nodules associated with vascular patterns and correlate these directly with reference histopathology. RESULTS: Our methods show the ability to resolve blood vessels with diameters of 250 µm at depths of up to 2 cm. The vessel diameters derived on MSOT showed an excellent correlation (R2-score of 0.9426) with the vessel diameters on histopathology. Subsequently, we identify features of malignancy observable in MSOT, such as intranodular microvascularity and extrathyroidal extension verified by histopathology. Despite these promising features in selected patients, we could not determine statistically relevant differences between benign and malignant thyroid nodules based on mean oxygen saturation in thyroid nodules. Thus, we illustrate general imaging artifacts of the whole field of optoacoustic imaging that reduce image fidelity and distort spectral contrast, which impedes quantification of chromophore presence based on mean concentrations. CONCLUSION: We recommend examining optoacoustic features in addition to chromophore quantification to rank malignancy risk. We present optoacoustic images of thyroid nodules with the highest spatial resolution and spectral contrast to date, directly correlated to histopathology, pushing the clinical translation of MSOT.


Asunto(s)
Técnicas Fotoacústicas , Nódulo Tiroideo , Humanos , Nódulo Tiroideo/diagnóstico por imagen , Proyectos Piloto , Técnicas Fotoacústicas/métodos , Tomografía/métodos , Tomografía Computarizada por Rayos X
8.
Eur J Nucl Med Mol Imaging ; 50(8): 2258-2270, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36947185

RESUMEN

PURPOSE: Monoclonal antibody (mAb)-based PET (immunoPET) imaging can characterise tumour lesions non-invasively. It may be a valuable tool to determine which patients may benefit from treatment with a specific monoclonal antibody (mAb) and evaluate treatment response. For 89Zr immunoPET imaging, higher sensitivity of state-of-the art PET/CT systems equipped with silicon photomultiplier (SiPM)-based detector elements may be beneficial as the low positron abundance of 89Zr causes a low signal-to-noise level. Moreover, the long physical half-life limits the amount of activity that can be administered to the patients leading to poor image quality even when using long scan durations. Here, we investigated the difference in semiquantitative performance between the PMT-based Biograph mCT, our clinical reference system, and the SiPM-based Biograph Vision PET/CT in 89Zr immunoPET imaging. Furthermore, the effects of scan duration reduction using the Vision on semiquantitative imaging parameters and its influence on image quality assessment were evaluated. METHODS: Data were acquired on day 4 post 37 MBq 89Zr-labelled mAb injection. Five patients underwent a double scan protocol on both systems. Ten patients were scanned only on the Vision. For PET image reconstruction, three protocols were used, i.e. one camera-dependent protocol and European Association of Nuclear Medicine Research Limited (EARL) standards 1 and 2 compliant protocols. Vision data were acquired in listmode and were reprocessed to obtain images at shorter scan durations. Semiquantitative PET image parameters were derived from tumour lesions and healthy tissues to assess differences between systems and scan durations. Differently reconstructed images obtained using the Vision were visually scored regarding image quality by two nuclear medicine physicians. RESULTS: When images were reconstructed using 100% acquisition time on both systems following EARL standard 1 compliant reconstruction protocols, results regarding semiquantification were comparable. For Vision data, reconstructed images that conform to EARL1 standards still resulted in comparable semiquantification at shorter scan durations (75% and 50%) regarding 100% acquisition time. CONCLUSION: Scan duration of 89Zr immunoPET imaging using the Vision can be decreased up to 50% compared with using the mCT while maintaining image quality using the EARL1 compliant reconstruction protocol.


Asunto(s)
Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias/diagnóstico por imagen , Estándares de Referencia , Anticuerpos Monoclonales , Tomografía de Emisión de Positrones/métodos , Procesamiento de Imagen Asistido por Computador
9.
J Clin Endocrinol Metab ; 108(9): 2435-2445, 2023 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-36948598

RESUMEN

CONTEXT: Imaging plays an important role in the characterization of adrenal tumors, but findings might be inconclusive. The clinical question is whether 18F fluodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) is of diagnostic value in this setting. OBJECTIVE: This meta-analysis was aimed at the diagnostic value of 18F-FDG PET/CT in differentiating benign from malignant adrenal tumors discovered either as adrenal incidentaloma or during staging or follow-up of oncologic patients. DATA SOURCES: PubMed, EMBASE, Web of Science, and Cochrane Library were searched to select articles between 2000 and 2021. STUDY SELECTION: We included studies describing the diagnostic value of 18F-FDG PET/CT in adult patients with an adrenal tumor. Exclusion criteria were 10 or fewer participants, insufficient data on histopathology, clinical follow-up, or PET results. After screening of title and abstract by 2 independent reviewers, 79 studies were retrieved, of which 17 studies met the selection criteria. DATA EXTRACTION: Data extraction using a protocol and quality assessment according to QUADAS-2 was performed independently by at least 2 authors. DATA SYNTHESIS: A bivariate random-effects model was applied using R (version 3.6.2.). Pooled sensitivity and specificity of 18F-FDG PET/CT for identifying malignant adrenal tumors was 87.3% (95% CI, 82.5%-90.9%) and 84.7% (95% CI, 79.3%-88.9%), respectively. The pooled diagnostic odds ratio was 9.20 (95% CI, 5.27-16.08; P < .01). Major sources of heterogeneity (I2, 57.1% [95% CI, 27.5%-74.6%]) were in population characteristics, reference standard, and interpretation criteria of imaging results. CONCLUSIONS: 18F-FDG PET/CT had good diagnostic accuracy for characterization of adrenal tumors. The literature, however, is limited, in particular regarding adrenal incidentalomas. Large prospective studies in well-defined patient populations with application of validated cutoff values are needed.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Tomografía Computarizada por Tomografía de Emisión de Positrones , Adulto , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Fluorodesoxiglucosa F18 , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Estudios Prospectivos , Sensibilidad y Especificidad , Radiofármacos , Tomografía de Emisión de Positrones/métodos
10.
Clin Cancer Res ; 29(3): 592-601, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36394882

RESUMEN

PURPOSE: Watchful waiting (WW) can be considered for patients with metastatic clear-cell renal cell carcinoma (mccRCC) with good or intermediate prognosis, especially those with <2 International Metastatic RCC Database Consortium criteria and ≤2 metastatic sites [referred to as watch and wait ("W&W") criteria]. The IMaging PAtients for Cancer drug SelecTion-Renal Cell Carcinoma study objective was to assess the predictive value of [18F]FDG PET/CT and [89Zr]Zr-DFO-girentuximab PET/CT for WW duration in patients with mccRCC. EXPERIMENTAL DESIGN: Between February 2015 and March 2018, 48 patients were enrolled, including 40 evaluable patients with good (n = 14) and intermediate (n = 26) prognosis. Baseline contrast-enhanced CT, [18F]FDG and [89Zr]Zr-DFO-girentuximab PET/CT were performed. Primary endpoint was the time to disease progression warranting systemic treatment. Maximum standardized uptake values (SUVmax) were measured using lesions on CT images coregistered to PET/CT. High and low uptake groups were defined on the basis of median geometric mean SUVmax of RECIST-measurable lesions across patients. RESULTS: The median WW time was 16.1 months [95% confidence interval (CI): 9.0-31.7]. The median WW period was shorter in patients with high [18F]FDG tumor uptake than those with low uptake (9.0 vs. 36.2 months; HR, 5.6; 95% CI: 2.4-14.7; P < 0.001). Patients with high [89Zr]Zr-DFO-girentuximab tumor uptake had a median WW period of 9.3 versus 21.3 months with low uptake (HR, 1.7; 95% CI: 0.9-3.3; P = 0.13). Patients with "W&W criteria" had a longer median WW period of 21.3 compared with patients without: 9.3 months (HR, 1.9; 95% CI: 0.9-3.9; Pone-sided = 0.034). Adding [18F]FDG uptake to the "W&W criteria" improved the prediction of WW duration (P < 0.001); whereas [89Zr]Zr-DFO-girentuximab did not (P = 0.53). CONCLUSIONS: In patients with good- or intermediate-risk mccRCC, low [18F]FDG uptake is associated with prolonged WW. This study shows the predictive value of the "W&W criteria" for WW duration and shows the potential of [18F]FDG-PET/CT to further improve this.


Asunto(s)
Carcinoma de Células Renales , Humanos , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/terapia , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluorodesoxiglucosa F18/uso terapéutico , Radioisótopos/uso terapéutico , Circonio , Espera Vigilante , Pronóstico , Radiofármacos/uso terapéutico
11.
Mol Imaging Biol ; 25(2): 435-441, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36195742

RESUMEN

PURPOSE: As novel tracers are continuously under development, it is important to obtain reliable radiation dose estimates to optimize the amount of activity that can be administered while keeping radiation burden within acceptable limits. Organ segmentation is required for quantification of specific uptake in organs of interest and whole-body dosimetry but is a time-consuming task which induces high interobserver variability. Therefore, we explored using manual segmentations versus an artificial intelligence (AI)-based automated segmentation tool as a pre-processing step for calculating whole-body effective doses to determine the influence of variability in volumetric whole-organ segmentations on dosimetry. PROCEDURES: PET/CT data of six patients undergoing imaging with 89Zr-labelled pembrolizumab were included. Manual organ segmentations were performed, using in-house developed software, and biodistribution information was obtained. Based on the activity biodistribution information, residence times were calculated. The residence times served as input for OLINDA/EXM version 1.0 (Vanderbilt University, 2003) to calculate the whole-body effective dose (mSv/MBq). Subsequently, organ segmentations were performed using RECOMIA, a cloud-based AI platform for nuclear medicine and radiology research. The workflow for calculating residence times and whole-body effective doses, as described above, was repeated. RESULTS: Data were acquired on days 2, 4, and 7 post-injection, resulting in 18 scans. Overall analysis time per scan was approximately 4 h for manual segmentations compared to ≤ 30 min using AI-based segmentations. Median Jaccard similarity coefficients between manual and AI-based segmentations varied from 0.05 (range 0.00-0.14) for the pancreas to 0.78 (range 0.74-0.82) for the lungs. Whole-body effective doses differed minimally for the six patients with a median difference in received mSv/MBq of 0.52% (range 0.15-1.95%). CONCLUSION: This pilot study suggests that whole-body dosimetry calculations can benefit from fast, automated AI-based whole organ segmentations.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Humanos , Tomografía de Emisión de Positrones/métodos , Inteligencia Artificial , Distribución Tisular , Proyectos Piloto , Radiometría/métodos
12.
Cancer Imaging ; 22(1): 69, 2022 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-36527149

RESUMEN

This review describes the main benefits of using long axial field of view (LAFOV) PET in clinical applications. As LAFOV PET is the latest development in PET instrumentation, many studies are ongoing that explore the potentials of these systems, which are characterized by ultra-high sensitivity. This review not only provides an overview of the published clinical applications using LAFOV PET so far, but also provides insight in clinical applications that are currently under investigation. Apart from the straightforward reduction in acquisition times or administered amount of radiotracer, LAFOV PET also allows for other clinical applications that to date were mostly limited to research, e.g., dual tracer imaging, whole body dynamic PET imaging, omission of CT in serial PET acquisition for repeat imaging, and studying molecular interactions between organ systems. It is expected that this generation of PET systems will significantly advance the field of nuclear medicine and molecular imaging.


Asunto(s)
Electrones , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Radioisótopos
13.
Nat Med ; 28(12): 2601-2610, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36471036

RESUMEN

Immune checkpoint inhibitors (ICIs), by reinvigorating CD8+ T cell mediated immunity, have revolutionized cancer therapy. Yet, the systemic CD8+ T cell distribution, a potential biomarker of ICI response, remains poorly characterized. We assessed safety, imaging dose and timing, pharmacokinetics and immunogenicity of zirconium-89-labeled, CD8-specific, one-armed antibody positron emission tomography tracer 89ZED88082A in patients with solid tumors before and ~30 days after starting ICI therapy (NCT04029181). No tracer-related side effects occurred. Positron emission tomography imaging with 10 mg antibody revealed 89ZED88082A uptake in normal lymphoid tissues, and tumor lesions across the body varying within and between patients two days after tracer injection (n = 38, median patient maximum standard uptake value (SUVmax) 5.2, IQI 4.0-7.4). Higher SUVmax was associated with mismatch repair deficiency and longer overall survival. Uptake was higher in lesions with stromal/inflamed than desert immunophenotype. Tissue radioactivity was localized to areas with immunohistochemically confirmed CD8 expression. Re-imaging patients on treatment showed no change in average (geometric mean) tumor tracer uptake compared to baseline, but individual lesions showed diverse changes independent of tumor response. The imaging data suggest enormous heterogeneity in CD8+ T cell distribution and pharmacodynamics within and between patients. In conclusion, 89ZED88082A can characterize the complex dynamics of CD8+ T cells in the context of ICIs, and may inform immunotherapeutic treatments.


Asunto(s)
Inmunoconjugados , Neoplasias , Humanos , Linfocitos T CD8-positivos , Neoplasias/diagnóstico por imagen , Neoplasias/tratamiento farmacológico , Tomografía de Emisión de Positrones/métodos , Inmunoterapia/efectos adversos , Inmunoterapia/métodos
14.
Stem Cell Reports ; 17(11): 2518-2530, 2022 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-36306782

RESUMEN

Parathyroid diseases are characterized by dysregulation of calcium homeostasis and alterations in parathyroid hormone (PTH) excretion. The development of parathyroid-targeted treatment and imaging tracers could benefit from in vitro models. Therefore, we aim to establish a patient-derived parathyroid organoid model representing human parathyroid tissue. Hyperplastic parathyroid tissue was dispersed, and parathyroid organoids (PTOs) were cultured and characterized. PTO-derived cells exhibited self-renewal over several passages, indicative of the presence of putative stem cells. Immunofluorescence and RNA sequencing confirmed that PTOs phenocopy hyperplastic parathyroid tissue. Exposure of PTOs to increasing calcium concentrations and PTH-lowering drugs resulted in significantly reduced PTH excretion. PTOs showed specific binding of the imaging tracers 11C-methionine and 99mTc-sestamibi. These data show the functionality of PTOs resembling the parathyroid. This PTO model recapitulates the originating tissue on gene and protein expression and functionality, paving the way for future physiology studies and therapeutic target and tracer discovery.


Asunto(s)
Hiperparatiroidismo Primario , Organoides , Humanos , Calcio , Glándulas Paratiroides , Tecnecio Tc 99m Sestamibi
15.
EJNMMI Phys ; 9(1): 74, 2022 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-36308568

RESUMEN

BACKGROUND: Excellent performance characteristics of the Vision Quadra PET/CT, e.g. a substantial increase in sensitivity, allow for precise measurements of image-derived input functions (IDIF) and tissue time activity curves. Previously we have proposed a method for a reduced 30 min (as opposed to 60 min) whole body 18F-FDG Patlak PET imaging procedure using a previously published population-averaged input function (PIF) scaled to IDIF values at 30-60 min post-injection (p.i.). The aim of the present study was to apply this method using the Vision Quadra PET/CT, including the use of a PIF to allow for shortened scan durations. METHODS: Twelve patients with suspected lung malignancy were included and received a weight-based injection of 18F-FDG. Patients underwent a 65-min dynamic PET acquisition which were reconstructed using European Association of Nuclear Medicine Research Ltd. (EARL) standards 2 reconstruction settings. A volume of interest (VOI) was placed in the ascending aorta (AA) to obtain the IDIF. An external PIF was scaled to IDIF values at 30-60, 40-60, and 50-60 min p.i., respectively, and parametric 18F-FDG influx rate constant (Ki) images were generated using a t* of 30, 40 or 50 min, respectively. Herein, tumour lesions as well as healthy tissues, i.e. liver, muscle tissue, spleen and grey matter, were segmented. RESULTS: Good agreement between the IDIF and corresponding PIF scaled to 30-60 min p.i. and 40-60 min p.i. was obtained with 7.38% deviation in Ki. Bland-Altman plots showed excellent agreement in Ki obtained using the PIF scaled to the IDIF at 30-60 min p.i. and at 40-60 min p.i. as all data points were within the limits of agreement (LOA) (- 0.004-0.002, bias: - 0.001); for the 50-60 min p.i. Ki, all except one data point fell in between the LOA (- 0.021-0.012, bias: - 0.005). CONCLUSIONS: Parametric whole body 18F-FDG Patlak Ki images can be generated non-invasively on a Vision Quadra PET/CT system. In addition, using a scaled PIF allows for a substantial (factor 2 to 3) reduction in scan time without substantial loss of accuracy (7.38% bias) and precision (image quality and noise interference).

16.
Eur Thyroid J ; 11(6)2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36169927

RESUMEN

Objective: Thyroglobulin (Tg) is an established tumor marker for differentiated thyroid carcinoma (DTC) patients. However, Tg immunoassays can be subject to Tg autoantibody (TgAb) interference resulting in incorrect Tg values. Therefore, Tg measurement with liquid chromatography-tandem mass spectrometry (LC-MS/MS) could be promising in patients with TgAbs. In this study, we compared Tg IRMA and Tg-LC-MS/MS analytically in the presence of TgAbs. Furthermore, we compared the clinical interpretation of results obtained by both Tg assays in DTC patients with lower TgAbs titers (<10 U/mL) during 131I ablation therapy. Methods: Totally 118 DTC patients diagnosed between 2006 and 2014 in a University Medical Center were followed with the Tg-IRMA (Thermo Fischer Scientific) and ARCHITECT anti-Tg (Abbott Laboratories) assays. We re-analyzed their samples with a sensitive Tg-LC-MS/MS method (Labcorp, limit of quantification of 0.02 ng/mL). Passing-Bablok regression analysis was performed on samples obtained during 131I ablation therapy and follow-up. Results: In 304 samples with lower TgAb titers, a good analytical agreement was found between both Tg assays (slope of 1.09 (95% CI: 1.05-1.16)). Fifty-five samples with potentially interfering TgAbs showed higher Tg-LC-MS/MS values than Tg-IRMA (slope of 1.45 (95% CI: 1.12->>100)). In patients(n = 91) with lower TgAb titers at the time of 131I ablation therapy, the Tg assays showed a clinical concordance of 91.2, 87.9, and 98.9%, respectively, using a Tg cut-off value of 1.0, 2.0, and 5.0 ng/mL. Conclusions: In DTC patients with lower titer TgAbs, Tg-IRMA is still a reliable and useful tumor marker. In DTC patients with potentially interfering TgAbs, Tg-IRMA values decreased due to TgAb interference.

17.
EJNMMI Phys ; 9(1): 53, 2022 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-35943622

RESUMEN

BACKGROUND: Machine learning studies require a large number of images often obtained on different PET scanners. When merging these images, the use of harmonized images following EARL-standards is essential. However, when including retrospective images, EARL accreditation might not have been in place. The aim of this study was to develop a convolutional neural network (CNN) that can identify retrospectively if an image is EARL compliant and if it is meeting older or newer EARL-standards. MATERIALS AND METHODS: 96 PET images acquired on three PET/CT systems were included in the study. All images were reconstructed with the locally clinically preferred, EARL1, and EARL2 compliant reconstruction protocols. After image pre-processing, one CNN was trained to separate clinical and EARL compliant reconstructions. A second CNN was optimized to identify EARL1 and EARL2 compliant images. The accuracy of both CNNs was assessed using fivefold cross-validation. The CNNs were validated on 24 images acquired on a PET scanner not included in the training data. To assess the impact of image noise on the CNN decision, the 24 images were reconstructed with different scan durations. RESULTS: In the cross-validation, the first CNN classified all images correctly. When identifying EARL1 and EARL2 compliant images, the second CNN identified 100% EARL1 compliant and 85% EARL2 compliant images correctly. The accuracy in the independent dataset was comparable to the cross-validation accuracy. The scan duration had almost no impact on the results. CONCLUSION: The two CNNs trained in this study can be used to retrospectively include images in a multi-center setting by, e.g., adding additional smoothing. This method is especially important for machine learning studies where the harmonization of images from different PET systems is essential.

18.
Eur J Endocrinol ; 187(4): 497-505, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-35947635

RESUMEN

Background: Pediatric differentiated thyroid cancer (DTC) has an excellent prognosis but unknown late effects of treatment. The initial cardiac evaluation showed subclinical diastolic dysfunction in 20% of adult survivors. The objective of this follow-up study was to determine the clinical course of this finding. Methods: This multicenter study, conducted between 2018 and 2020, re-evaluated survivors after 5 years. The primary endpoint was echocardiographic diastolic cardiac function (depicted by the mean of the early diastolic septal and early diastolic lateral tissue velocity (e' mean)). Secondary endpoints were other echocardiographic parameters and plasma biomarkers. Results: Follow-up evaluation was completed in 47 (71.2%) of 66 survivors who had completed their initial evaluation. Of these 47 survivors, 87.2% were women. The median age was 39.8 years (range: 18.8-60.3), and the median follow-up after the initial diagnosis was 23.4 years (range: 10.2-48.8). Between the first and second evaluation, the e' mean significantly decreased by 2.1 cm/s (s.d. 2.3 cm/s, P < 0.001). The median left ventricular ejection fraction did not significantly change (58.0% vs 59.0%, P= NS). In the best explanatory model of e' mean, multivariate linear regression analysis showed that BMI and age were significantly associated with e' mean (ß coefficient: -0.169, 95% CI: -0.292; -0.047, P = 0.008 and ß coefficient: -0.177, 95% CI: -0.240; -0.113, P < 0.001, respectively). Conclusions and relevance: In these relatively young survivors of pediatric DTC, diastolic function decreased significantly during 5-year follow-up and is possibly more pronounced than in normal aging. This finding requires further follow-up to assess clinical consequences.


Asunto(s)
Neoplasias de la Tiroides , Disfunción Ventricular Izquierda , Adulto , Niño , Diástole , Femenino , Estudios de Seguimiento , Humanos , Masculino , Volumen Sistólico , Sobrevivientes , Función Ventricular Izquierda
19.
J Immunother Cancer ; 10(8)2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35922089

RESUMEN

The advent of immune checkpoint inhibitors has reinvigorated the field of immuno-oncology. These monoclonal antibody-based therapies allow the immune system to recognize and eliminate malignant cells. This has resulted in improved survival of patients across several tumor types. However, not all patients respond to immunotherapy therefore predictive biomarkers are important. There are only a few Food and Drug Administration-approved biomarkers to select patients for immunotherapy. These biomarkers do not consider the heterogeneity of tumor characteristics across lesions within a patient. New molecular imaging tracers allow for whole-body visualization with positron emission tomography (PET) of tumor and immune cell characteristics, and drug distribution, which might guide treatment decision making. Here, we summarize recent developments in molecular imaging of immune checkpoint molecules, such as PD-L1, PD-1, CTLA-4, and LAG-3. We discuss several molecular imaging approaches of immune cell subsets and briefly summarize the role of FDG-PET for evaluating cancer immunotherapy. The main focus is on developments in clinical molecular imaging studies, next to preclinical studies of interest given their potential translation to the clinic.


Asunto(s)
Inmunoterapia , Neoplasias , Anticuerpos Monoclonales/uso terapéutico , Humanos , Inmunoterapia/métodos , Imagen Molecular , Neoplasias/tratamiento farmacológico , Neoplasias/terapia , Tomografía de Emisión de Positrones/métodos
20.
Eur J Nucl Med Mol Imaging ; 49(13): 4652-4660, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35876867

RESUMEN

PURPOSE: Current European Association of Nuclear Medicine (EANM) Research Ltd. (EARL) guidelines for the standardisation of PET imaging developed for conventional systems have not yet been adjusted for long axial field-of-view (LAFOV) systems. In order to use the LAFOV Siemens Biograph Vision Quadra PET/CT (Siemens Healthineers, Knoxville, TN, USA) in multicentre research and harmonised clinical use, compliance to EARL specifications for 18F-FDG tumour imaging was explored in the current study. Additional tests at various locations throughout the LAFOV and the use of shorter scan durations were included. Furthermore, clinical data were collected to further explore and validate the effects of reducing scan duration on semi-quantitative PET image biomarker accuracy and precision when using EARL-compliant reconstruction settings. METHODS: EARL compliance phantom measurements were performed using the NEMA image quality phantom both in the centre and at various locations throughout the LAFOV. PET data (maximum ring difference (MRD) = 85) were reconstructed using various reconstruction parameters and reprocessed to obtain images at shorter scan durations. Maximum, mean and peak activity concentration recovery coefficients (RC) were obtained for each sphere and compared to EARL standards specifications. Additionally, PET data (MRD = 85) of 10 oncological patients were acquired and reconstructed using various reconstruction settings and reprocessed from 10 min listmode acquisition into shorter scan durations. Per dataset, SUVs were derived from tumour lesions and healthy tissues. ANOVA repeated measures were performed to explore differences in lesion SUVmax and SUVpeak. Wilcoxon signed-rank tests were performed to evaluate differences in background SUVpeak and SUVmean between scan durations. The coefficient of variation (COV) was calculated to characterise noise. RESULTS: Phantom measurements showed EARL compliance for all positions throughout the LAFOV for all scan durations. Regarding patient data, EARL-compliant images showed no clinically meaningful significant differences in lesion SUVmax and SUVpeak or background SUVmean and SUVpeak between scan durations. Here, COV only varied slightly. CONCLUSION: Images obtained using the Vision Quadra PET/CT comply with EARL specifications. Scan duration and/or activity administration can be reduced up to a factor tenfold without the interference of increased noise.


Asunto(s)
Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Fluorodesoxiglucosa F18 , Fantasmas de Imagen , Biomarcadores
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA