RESUMEN
PURPOSE: To compare complications in patients with cholangiocarcinoma (CCC) and patients with colorectal liver metastases (CRLMs) after portal vein embolization (PVE) and to identify possible predictive factors. MATERIAL AND METHODS: Retrospective analysis of consecutive patients, who underwent PVE between July 2011 and March 2020. The study groups were matched for sex and age. Multivariable analysis was performed for the endpoints of complications categorized according for their respective effect on surgical treatment: "Minor" complications had no effect on subsequent surgical treatment, while "intermediate" and "severe" complications delayed or prevented surgery. RESULTS: A total of 160 patients with either CCC (n = 80) or CRLMs (n = 80) were included: 34/160 experienced complications: 27 (CCC: 21; CRLMs: 6) "minor", 4 (CCC: 3; CRLMs: 1) "intermediate", and 3 (CCC: 2; CRLMs: 1) "severe" complications respectively (p = .01). Patients with CCC received a biliary drainage 5 days on average before PVE. Baseline bilirubin levels were 1.1 mg/dl in CCC patients and 0.55 mg/dl in CRLMs patients (p < .01). Postinterventional infections were more common in CCC patients. The preintervention future liver remnant volume (odds ratio (OR) 0.93; 95% confidence interval (CI) 0.88-0.99; p = .02), body mass index (OR 1.19; 95% CI 1.04-1.36; p = .01), age (OR 0,91; 95% CI 0.84-0.99; p = .01), chemotherapy before PVE (OR 0.03; 95% CI 0.01-0.23; p < .01) and severe liver steatosis (OR 29.52; 95% CI 1.87-467,13; p = .02) were the only significant predictive factors for the occurrence of (minor) complications. CONCLUSION: PVE can be performed in CCC patients with prior biliary drainage, with similar procedural safety as in patients with CRLMs.
Asunto(s)
Neoplasias de los Conductos Biliares , Colangiocarcinoma , Neoplasias Colorrectales , Embolización Terapéutica , Neoplasias Hepáticas , Vena Porta , Humanos , Masculino , Femenino , Estudios Retrospectivos , Neoplasias Colorrectales/patología , Embolización Terapéutica/métodos , Persona de Mediana Edad , Neoplasias de los Conductos Biliares/patología , Neoplasias de los Conductos Biliares/terapia , Anciano , Colangiocarcinoma/terapia , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/terapia , Complicaciones Posoperatorias , Anciano de 80 o más AñosRESUMEN
STUDY PURPOSE: The DRAGON 1 trial aims to assess training, implementation, safety and feasibility of combined portal- and hepatic-vein embolization (PVE/HVE) to accelerate future liver remnant (FLR) hypertrophy in patients with borderline resectable colorectal cancer liver metastases. METHODS: The DRAGON 1 trial is a worldwide multicenter prospective single arm trial. The primary endpoint is a composite of the safety of PVE/HVE, 90-day mortality, and one year accrual monitoring of each participating center. Secondary endpoints include: feasibility of resection, the used PVE and HVE techniques, FLR-hypertrophy, liver function (subset of centers), overall survival, and disease-free survival. All complications after the PVE/HVE procedure are documented. Liver volumes will be measured at week 1 and if applicable at week 3 and 6 after PVE/HVE and follow-up visits will be held at 1, 3, 6, and 12 months after the resection. RESULTS: Not applicable. CONCLUSION: DRAGON 1 is a prospective trial to assess the safety and feasibility of PVE/HVE. Participating study centers will be trained, and procedures standardized using Work Instructions (WI) to prepare for the DRAGON 2 randomized controlled trial. Outcomes should reveal the accrual potential of centers, safety profile of combined PVE/HVE and the effect of FLR-hypertrophy induction by PVE/HVE in patients with CRLM and a small FLR. TRIAL REGISTRATION: Clinicaltrials.gov: NCT04272931 (February 17, 2020). Toestingonline.nl: NL71535.068.19 (September 20, 2019).
Asunto(s)
Embolización Terapéutica , Neoplasias Hepáticas , Acreditación , Embolización Terapéutica/métodos , Hepatectomía/métodos , Venas Hepáticas/patología , Hepatomegalia , Humanos , Hipertrofia/etiología , Hipertrofia/patología , Hipertrofia/cirugía , Hígado/cirugía , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/terapia , Estudios Multicéntricos como Asunto , Vena Porta/patología , Estudios Prospectivos , Resultado del TratamientoRESUMEN
PURPOSE: To investigate efficacy and patency status of stent graft implantation in the treatment of hepatic artery pseudoaneurysm. MATERIALS AND METHODS: A retrospective analysis of patients who had undergone endovascular treatment of hepatic artery pseudoaneurysms between 2011 and 2020 was performed. Medical records were examined to obtain patients' surgical histories and to screen for active bleeding. Angiographic data on vascular access, target vessel, material used and technical success, defined as the exclusion of the pseudoaneurysm by means of a stent graft with sufficient control of bleeding, were collected. Vessel patency at follow-up CT was analyzed and classified as short-term (< 6 weeks), mid-term (between 6 weeks and 1 year), and long-term patency (> 1 year). In case of stent occlusion, collateralization and signs of hepatic hypoperfusion were examined. RESULTS: In total, 30 patients were included and of these, 25 and 5 had undergone stent graft implantation and coiling, respectively. In patients with implanted stent grafts, technical success was achieved in 23/25 patients (92%). Follow-up CT scans were available in 16 patients, showing stent graft patency in 9/16 patients (56%). Short-term, mid-term, and long-term short-term stent patency was found in 81% (13/16), 40% (4/10), and 50% (2/4). In patients with stent graft occlusion, 86% (6/7) exhibited maintenance of arterial liver perfusion via collaterals and 14% (1/7) exhibited liver abscess during follow-up. CONCLUSION: Stent graft provides an effective treatment for hepatic artery pseudoaneurysms. Even though patency rates decreased as a function of time, stent occlusion was mainly asymptomatic due to sufficient collateralization.
Asunto(s)
Aneurisma Falso , Implantación de Prótesis Vascular , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/cirugía , Prótesis Vascular , Estudios de Seguimiento , Arteria Hepática/diagnóstico por imagen , Arteria Hepática/cirugía , Humanos , Estudios Retrospectivos , Stents , Resultado del Tratamiento , Grado de Desobstrucción VascularRESUMEN
PURPOSE: To investigate whether sarcopenia and myosteatosis correlate with the degree of hypertrophy (DH) and kinetic growth rate (KiGR) of the future liver remnant (FLR) in patients with colorectal liver metastases undergoing portal vein embolization (PVE) in preparation for right hepatectomy. MATERIALS AND METHODS: Forty-two patients were included. Total liver volume and FLR volume were measured before and 2-4 weeks after PVE. KiGR of the FLR was calculated. Sarcopenia was assessed using the total psoas muscle volume (PMV), the psoas muscle cross-sectional area (PMCS) and the total skeletal muscle index (L3SMI) at the level of 3rd lumbar vertebra. Degree of myosteatosis was assessed by mean muscle attenuation at L3 (L3MA). Correlations between muscle indices and DH and KiGR were assessed using simple linear regression analyses. RESULTS: Mean DH was 8.9 ± 5.7%, and mean KiGR was 3.6 ± 2.3. Mean PMV was 55.56 ± 14.19 cm3/m3, mean PMCS was 8.76 ± 2.3 cm2/m2, mean L3SMI was 45.6 ± 9.89 cm2/m2, and mean L3MA was 27.9 ± 18.6 HU. There was a strong positive correlation between PMV and DH (R = 0.503, p = 0.001) and PMV and KiGR (R = 0.545, p < 0.001). Furthermore, there was a moderate correlation between PMCS and KiGR (R = 0.389, p = 0.014). L3SMI and L3MA were neither associated with DH (p = 0.390 and p = 0.768, respectively) nor with KiGR (p = 0.188 and p = 0.929, respectively). CONCLUSION: We identified a positive correlation between PMV and PMCS, as markers for sarcopenia, and the KiGR of the FLR after PVE. PMV and PMCS might therefore aid to identify patients who are poor candidates for FLR augmentation using PVE alone.
Asunto(s)
Neoplasias Colorrectales/patología , Embolización Terapéutica/métodos , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/terapia , Hígado/anatomía & histología , Vena Porta/diagnóstico por imagen , Sarcopenia/fisiopatología , Adulto , Anciano , Femenino , Humanos , Hígado/crecimiento & desarrollo , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Estudios Retrospectivos , Sarcopenia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía Intervencional/métodosRESUMEN
INTRODUCTION: Significant intratumoral shunts between tumor-supplying arteries and portal or liver veins are a contraindication for transarterial therapy of HCC because interventional treatment of these shunts is frequently insufficient. Sorafenib has anti-angiogenic effects and is indicated for palliative treatment of patients with HCC. Here, we report our experience with the use of sorafenib for the closure of intratumoral shunts in patients scheduled for transarterial therapy of HCC. MATERIALS AND METHODS: Three patients with HCC, aged 65, 82 and 79 years, exhibited a significant intratumoral shunting from tumor artery to portal (n = 1) or liver veins (n = 2). In all cases, intratumoral shunting had already been suspected based on pre-interventional CT angiography, and DSA confirmed the shunt. Oral sorafenib (800 mg/day) was administered for at least four weeks, only and specifically to occlude the shunt. Hereafter, patients were re-evaluated by CT and DSA. RESULTS: All patients tolerated the full prescribed dose for at least 4 weeks. In one case, therapy was prolonged with an adapted dose (400 mg/day) due to sorafenib-related hand-foot syndrome. After sorafenib treatment, CT and DSA confirmed a complete closure of intratumoral shunts for all patients. No tumor progression was observed. All three patients hereafter underwent successful transarterial treatment by TACE (n = 2) or TARE (n = 1) without complications. Progression-free survival according to mRECIST was 501, 397 and 599 days, respectively. CONCLUSION: Even short-term oral sorafenib seems to effectively close intratumoral shunts in patients with HCC and thus might enable transarterial treatment of these patients.
Asunto(s)
Antineoplásicos/uso terapéutico , Carcinoma Hepatocelular/irrigación sanguínea , Neoplasias Hepáticas/irrigación sanguínea , Neovascularización Patológica/tratamiento farmacológico , Sorafenib/uso terapéutico , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Antineoplásicos/administración & dosificación , Carcinoma Hepatocelular/complicaciones , Carcinoma Hepatocelular/diagnóstico por imagen , Quimioembolización Terapéutica , Femenino , Humanos , Infusiones Intraarteriales , Hígado/irrigación sanguínea , Hígado/diagnóstico por imagen , Neoplasias Hepáticas/complicaciones , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Neovascularización Patológica/complicaciones , Neovascularización Patológica/diagnóstico por imagen , Estudios Retrospectivos , Sorafenib/administración & dosificación , Tiempo , Tomografía Computarizada por Rayos X , Resultado del TratamientoRESUMEN
BACKGROUND: Carbon dioxide (CO2) is a very good and validated alternative to iodine-containing contrast media in diagnostic and interventional angiography. Nevertheless, its routinely use is still limited to specialized centers. OBJECTIVE: The presentation of the current role and limitations of CO2 in diagnostic and interventional angiography (venous and arterial). MATERIAL AND METHODS: A comprehensive review of the literature regarding CO2 angiography (physical features, indications, contraindications, applications) was carried out. RESULTS: The results show that CO2 can be used as a reliable alternative for diagnostic angiography and to support interventions in many arterial and venous vascular territories. An exception is the intra-arterial use of CO2 above the diaphragm due to the risk of severe myocardial and cerebral complications, which represents the most important contraindication. Moreover, due to its very low viscosity, CO2 is more effective than iodine-containing contrast media in detecting bleeding arising from small vessels. CONCLUSION: The CO2 angiography is a safe and effective technique and can be used as valid alternative. In several clinical cases it even offers some advantages compared to iodine-containing contrast media.
Asunto(s)
Angiografía de Substracción Digital , Dióxido de Carbono , Medios de Contraste , Arterias , Contraindicaciones , HumanosRESUMEN
INTRODUCTION: The purpose of this study was to analyse the value of 3-dimensional computed tomography cholangiography (3D-ERC) compared to conventional retrograde cholangiography in the preoperative diagnosis of hilar cholangiocarcinoma (HC) with special regard to the resection margin status (R0/R1). PATIENTS AND METHODS: All hepatic resections performed between January 2011 and November 2013 in patients with HC at the Department of General, Visceral and Transplant Surgery of the RWTH Aachen University Hospital were analysed. All patients underwent an ERC and contrast-enhanced multiphase CT scan or a 3D-ERC. RESULTS: The patient collective was divided into two groups (group ERC: n = 17 and group 3D-ERC: n = 16). There were no statistically significant differences between the two groups with regard to patient characteristics or intraoperative data. Curative liver resection with R0 status was reached in 88% of patients in group ERC and 87% of patients in group 3D-ERC (p = 1.00). We could not observe any differences with regard to postoperative complications, hospital stay, and mortality rate between both groups. CONCLUSION: Based on our findings, preoperative imaging with 3D-ERC has no benefit for operative planning and R0 resection status. It cannot replace the exploration by an experienced surgeon in a centre for hepatobiliary surgery.
RESUMEN
BACKGROUND: The main limiting factor for major liver resections is the volume and function of the future remnant liver (FLR). Portal vein embolization (PVE) is now standard in most centers for preoperative hypertrophy of FLR. However, it has a failure rate of about 20-30 %. In these cases, the "Associating Liver Partition and Portal Vein Ligation for Staged Hepatectomy" (ALPPS) may represent a suitable and possibly the only alternative. METHODS: We performed a retrospective analysis of nine patients who had ALPPS following an insufficient hypertrophy after PVE. Computed tomography volumetry were performed before and after PVE as well as the first step of ALPPS. Furthermore, complications, 30-day mortality and outcome were analyzed. RESULTS: The FLR volume rose significantly by 77.7 ± 40.7 % (FLR/TLV: 34.9 ± 9.7 %) as early as 9 days after the first stage despite insufficient hypertrophy after preoperative portal vein embolization. Major complications (Grade > IIIb) occurred in 33 % of the patients, and 30-day mortality was 11.1 %. The OS at 1 and 2 years was 78 and 44 %. Four patients are presently still alive at a median of 33.4 (range 15-48) months (survival rate 44.4 %). CONCLUSION: The ALPPS procedure could be a suitable alternative for patients following insufficient PVE or indeed the last chance of a potentially curative treatment in this situation. Nevertheless, the high morbidity and mortality rates and the lack of data on the long-term oncological outcome must also be taken into account.
Asunto(s)
Embolización Terapéutica , Hepatectomía/métodos , Neoplasias Hepáticas/cirugía , Regeneración Hepática , Vena Porta , Adulto , Anciano , Femenino , Humanos , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Complicaciones Posoperatorias , Estudios RetrospectivosRESUMEN
BACKGROUND: By the intensified combination of systemic, surgical and local ablative therapies a significant improvement in therapy results for metastasized colorectal cancer has been achieved in the last decade. Downstaging with subsequent resection is nowadays a standard for oligometastasized primarily unresectable colorectal cancer. MATERIAL AND METHODS: The value of combining resection and local ablation is unclear; therefore, this article gives an overview of the available literature dealing with the combination of surgery and local ablative methods for oligometastasized stage IV colorectal cancer. RESULTS: The best results were obtained following surgical resection alone. Whereas nowadays cryoablation is of minor importance, the most successful results are achieved following local ablative methods by radiofrequency and microwave ablation. In the future irreversible electroporation will be the most promising local ablative method. A combination of surgical resection and local ablation appears to be rational in patients if an R0 resection can be achieved. CONCLUSION: Surgical resection of colorectal liver metastases is the gold standard for oncological therapy whenever possible. The rational combination of non-curative surgical resection and local ablation should be considered in the context of a multimodal therapeutic strategy, particularly in patients with primarily resectable disease.
Asunto(s)
Técnicas de Ablación , Colectomía , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/cirugía , Metastasectomía , Terapia Combinada , Progresión de la Enfermedad , Humanos , Estadificación de NeoplasiasRESUMEN
PURPOSE: Hepatic artery pseudoaneurysms are a rare but potentially life-threatening complication of major pancreaticobiliary surgery. We evaluated the safety and efficacy of endovascular stentgraft implantation for the management of such vascular lesions. MATERIALS AND METHODS: Between May 2013 and October 2015, ten patients with postoperative hepatic artery pseudoaneurysm, of which eight presented with active hemorrhage, were treated with endovascular stentgraft implantation. All patients had undergone major pancreatic or hepatic surgery before (pylorus-preserving pancreaticoduodenectomy, pancreatectomy, hemihepatectomy, extended hemihepatectomy). The pseudoaneurysms were diagnosed 13-202 days after surgery and were associated with postsurgical complications (e.g., leakage of pancreaticojejunal anastomosis). RESULTS: In 9/10 patients, the pseudoaneurysm was completely excluded via stentgraft implantation. In 1/10 patient, the pseudoaneurysm ruptured during the procedure and was successfully treated by immediate open surgery. In 1/10 patient, a second intervention was performed after 6 days because of rebleeding; this was successfully treated by implantation of a second overlapping stentgraft. Mean follow-up time is 51 days. None of the patients died due to stentgraft- or aneurysm-related complications. Further episodes of hemorrhage were not observed. In one patient, clinically asymptomatic complete occlusion of the stentgraft was discovered at follow-up imaging. CONCLUSION: Stentgraft implantation is a safe and effective technique to treat hepatic artery pseudoaneurysms related to major pancreatic or hepatic surgery, especially in the setting of acute hemorrhage.
Asunto(s)
Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/cirugía , Arteria Hepática/diagnóstico por imagen , Arteria Hepática/cirugía , Anciano , Prótesis Vascular , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Persona de Mediana Edad , Cuidados Posoperatorios , Implantación de Prótesis , StentsRESUMEN
PURPOSE: To investigate the safety and feasibility of the use of a vascular closure device (VCD) after endovascular procedures in swine. MATERIAL AND METHODS: In a study on endovascular therapy, VCD (StarClose, Abbott Vascular, Il, USA) was used in 20 female swines to achieve immediate hemostasis after percutaneous right femoral artery (FA) access. 10 animals were sacrificed immediately after the study and 10 animals were sacrificed 28 days after the initial study. To ensure complete hemostasis and patency of the femoral artery, a CT-angiography of the puncture site was performed on day 1 (acute and chronic group) and day 28 (chronic group). After the sacrifice, the femoral artery was explanted and examined macroscopically for signs of VCD dysfunction. RESULTS: Technical success rate was 100% with immediate hemostasis being achieved in all animals. No animals showed evidence of hematoma. During explantation, only small traces of coagulated blood were found in the acute group, while there were no signs of hematoma in the chronic group. CT-angiography immediately after VCD application as well as before sacrifice (chronic group) showed patency of the FA in all cases. CONCLUSION: The use of VCD to achieve hemostasis after endovascular studies in swine is feasible and safe.
Asunto(s)
Procedimientos Endovasculares/métodos , Dispositivos de Cierre Vascular , Animales , Femenino , Arteria Femoral/cirugía , Hematoma/prevención & control , PorcinosRESUMEN
PURPOSE: To evaluate heating efficacy of superparamagnetic iron oxide nanoparticles (SPIO) for electromagnetic ablation (EMA) of osteoid osteoma (OO) using an ex vivo model compared to radiofrequency ablation (RFA) and microwave ablation (MWA). METHODS: A model for OO using sliced bovine tibia and sliced muscle tissue was developed. A bone cavity filled with either a mixture of SPIO and agarose or pure agarose (control group) was established. EMA was performed using an experimental system, RFA and MWA using clinically approved systems, and the ablation protocols recommended by the vendor. For temperature measurements, fiberoptic temperature probes were inserted inside the cavity, on the outside of the periosteum, and at a 5 mm distance to the periosteum. RESULTS: Maximum temperatures with or without SPIO in the nidus were as follows: EMA: 79.9 ± 2.5/22.3 ± 0.7 °C; RFA: 95.1 ± 1.8/98.6 ± 0.9 °C; MWA: 85.1 ± 10.8/83.4 ± 9.62 °C. In RFA with or without SPIO significantly higher temperatures were achieved in the nidus compared to all other groups (p < 0.05). In MWA significantly higher temperatures were observed in the 5 mm distance to the periosteum compared to EMA and RFA with or without SPIO (p < 0.05). In MWA temperature decrease between nidus and the 5 mm distance to the periosteum was significantly lower than in RFA with or without SPIO (p < 0.0001). In MWA without SPIO temperature decrease was significantly lower than in the EMA group (p < 0.05). CONCLUSION: In the experimental setting, ablation of OO is safe and effective using EMA. It is less invasive than RFA and MWA, and it theoretically allows repeated treatments without repeated punctures. In comparison, the highest temperatures in the nidus are reached using RFA.
Asunto(s)
Ablación por Catéter/métodos , Dextranos/farmacología , Microondas/uso terapéutico , Osteoma Osteoide/cirugía , Animales , Bovinos , Modelos Animales de Enfermedad , Campos Electromagnéticos , Diseño de Equipo , Nanopartículas de Magnetita , Temperatura , TibiaRESUMEN
AIM: Before clinical implementation of an approved electromagnetic tracking system (CAPPA IRAD EMT) an experimental trial was performed to investigate the accuracy of the system and its safety in application for transpedicular vertebral punctures in comparison to the classical fluoroscopic method. MATERIAL AND METHODS: A total of 110 transpedicular punctures were performed bilaterally using 11 vertebrae of 5 realistic artificial phantoms and 1 pedicle was punctured with the conventional technique using c-arm fluoroscopy and the other with the electromagnetic tracking system. As a target a radiopaque non-ferromagnetic marker was implanted bilaterally in the anterior wall of the vertebrae. For evaluation of the precision the distance from the end of the puncture to the target and the gradual deviation of the actual channel from the ideal trajectory were assessed in three-dimensional computer tomography. Calculations and statistical analysis were performed according to the Wilcoxon test by means of SPSS 16.0.1 for Windows. RESULTS: The mean distance from the target was 6.6 mm (± 3.9 mm standard deviation SD) with electromagnetic navigation compared to 3.2 mm (± 2.8 mm SD) with fluoroscopic assistance and the mean aberration from the ideal trajectory was 18.4° (± 4.6° SD) compared to 6.5° (± 3.5° SD), respectively. The difference of accuracy was highly significant regarding both parameters (p < 0.001). CONCLUSIONS: The minimum requirement for accuracy of transpedicular punctures could not be achieved with electromagnetic navigation. Unless proven otherwise, the lack of accuracy is attributed to unstable referencing. Despite evidence of successful employment for soft tissue punctures the system cannot currently be recommended for osseous applications of the spine.
Asunto(s)
Magnetismo/instrumentación , Magnetismo/métodos , Punciones/instrumentación , Punciones/métodos , Columna Vertebral/cirugía , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/métodos , Campos Electromagnéticos , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Técnicas In Vitro , Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodosRESUMEN
PURPOSE: To systematically investigate the impact of image acquisition and contrast injection parameters for CO2-enhanced CT angiography (CTA) of the aorto-iliac and peripheral arteries in a pig model using commercially available equipment. The aim was to establish an imaging protocol that is ready for use in human subjects. MATERIALS AND METHODS: Three domestic swine underwent CO2-CTA with varying injection parameters: pitch (1.0, 3.0), injection pressure (0.7 bar, 1.0 bar, 1.3 bar) and scan delay (2 s, 4 s, 6 s). Objective (vessel diameter) and subjective (image quality) parameters and applied radiation doses were systematically evaluated. To ensure clinical applicability of the setting, only approved catheters/injectors and standard injection parameters were evaluated. RESULTS: The image quality scores were superior and the vessel diameter was larger with high pitch in comparison to standard pitch (diameters: 4.7 ± 2.0 mm vs. 3.6 ± 2.1 mm, p = 0.0040, scores: 2.6 ± 1.1 vs. 2.0 ± 1.1, p = 0.0038). High injection pressure (1.3 bar) improved the image quality as assessed by subjective and objective ratings (diameters: 3.6 ± 2.0 mm, 4.0 ± 2.1 mm and 4.6 ± 2.1 mm, for 0.7, 1.0 and 1.3 bar, p-values ≤ 0.0052, scores: 1.9 ± 1.1, 2.3 ± 1.1 and 2.7 ± 1.2, p-values ≤ 0.0017), the same was observed for a shorter injection delay (diameters: 3.5 ± 2.0 mm, 4.2 ± 2.1 mm and 4.8 ± 2.1 mm, for 6 s, 4 s, and 2 s, p ≤ 0.0022, scores: 1.9 ± 1.1, 2.3 ± 1.1 and 2.7 ± 1.1, p-values ≤ 0.0013). The dose length products were 239 ± 47 mGycm (high pitch) and 565 ± 63 mGycm (standard pitch, p-values < 0.0001). CONCLUSION: A higher pitch, shorter delay and higher injection pressure improve image quality in CO2-enhanced CTA. Since commercially available, clinically approved equipment was used. The protocol is now ready for use in human subjects.
Asunto(s)
Angiografía/métodos , Dióxido de Carbono/administración & dosificación , Medios de Contraste/administración & dosificación , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Relación Dosis-Respuesta a Droga , Modelos Animales , Presión , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , PorcinosRESUMEN
PURPOSE: Evaluation of the maximum temperatures and ablation volumes in microwave ablation (MWA) after injection of different concentrations of silicon carbide (SiC) particles in an ex-vivo bovine liver model. MATERIALS AND METHODS: 15 ml of different concentrations of SiC particles (20 vol% SiC; 50 vol% SiC) mixed with 2 % gelatin were injected into an ex-vivo bovine liver. As a reference group, 2 % gelatin without SiC was injected. MWA was performed using a clinical MWA system with different generator settings (10 - 45 W/10 minutes). The temperature was measured at a distance of 5 mm and 10 mm from the applicator. Afterwards the liver tissue was sliced along the short and long axis, the ablation zones were measured on the x, y and z-axis and the ablation volume was calculated. All experiments were performed 5 times (total: 40 experiments). RESULTS: The average maximum temperatures measured at a generator setting of 45 W at a distance of 5 mm from the applicator were 103.4 ± 4.6 °C (20 vol% SiC), 103.3 ± 6.5 °C (50 vol% SiC) and 96.0 ± 4.2 °C in the control group (0 vol% SiC). At 45 W, injection of 20 vol% SIC caused a significantly higher maximum temperature than that achieved in the control group (p = 0.016). No significant temperature increase compared to the control group could be measured using 50 vol% SiC. The mean ablation volumes at 45 W and 20 vol% SiC and 50 vol% SiC were significantly larger (172.7 ± 31.5 ml and 171.0 ± 34.7 ml, respectively) than those achieved in the control group (111.2 ± 23.8 ml) (p = 0.027 and p = 0.045). CONCLUSION: In an ex-vivo bovine liver model, the SiC particles demonstrated an enhancing effect of MWA with respect to maximum temperatures and ablation volume. Therefore, SiC is a promising candidate for enhancing MWA in vivo.
Asunto(s)
Materiales Biocompatibles , Compuestos Inorgánicos de Carbono/administración & dosificación , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Modelos Animales de Enfermedad , Hígado/cirugía , Compuestos de Silicona/administración & dosificación , Animales , Bovinos , Relación Dosis-Respuesta a Droga , Técnicas In Vitro , Inyecciones , Microondas , Tamaño de la Partícula , TemperaturaRESUMEN
PURPOSE: Currently used costing methods such as cost centre accounting do not sufficiently reflect the process-based resource utilization in medicine. The goal of this study was to establish a process-oriented cost assessment of percutaneous radiofrequency (RF) ablation of liver and lung metastases. MATERIAL AND METHODS: In each of 15 patients a detailed task analysis of the primary process of hepatic and pulmonary RF ablation was performed. Based on these data a dedicated cost calculation model was developed for each primary process. The costs of each process were computed and compared with the revenue for in-patients according to the German diagnosis-related groups (DRG) system 2010. RESULTS: The RF ablation of liver metastases in patients without relevant comorbidities and a low patient complexity level results in a loss of EUR 588.44, whereas the treatment of patients with a higher complexity level yields an acceptable profit. The treatment of pulmonary metastases is profitable even in cases of additional expenses due to complications. CONCLUSION: Process-oriented costing provides relevant information that is needed for understanding the economic impact of treatment decisions. It is well suited as a starting point for economically driven process optimization and reengineering. Under the terms of the German DRG 2010 system percutaneous RF ablation of lung metastases is economically reasonable, while RF ablation of liver metastases in cases of low patient complexity levels does not cover the costs.
Asunto(s)
Ablación por Catéter/economía , Costos de la Atención en Salud/estadística & datos numéricos , Neoplasias Hepáticas/economía , Neoplasias Hepáticas/cirugía , Neoplasias Pulmonares/economía , Neoplasias Pulmonares/cirugía , Radiografía Intervencional/economía , Adulto , Anciano , Ablación por Catéter/estadística & datos numéricos , Femenino , Alemania/epidemiología , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios de Casos Organizacionales , Evaluación de Procesos, Atención de Salud/métodos , Evaluación de Procesos, Atención de Salud/estadística & datos numéricos , Radiografía Intervencional/estadística & datos numéricosRESUMEN
Interventional radiological procedures for the treatment of primary and secondary pulmonary malignancies have become increasingly important. In addition to thermally ablative treatment, selective chemoembolisation by a vascular access allows localised therapy. These treatments are considered to be palliative for patients in a reduced general condition which does not allow systemic chemotherapy. In functionally inoperable patients especially the ablative procedures are potentially curative alternatives to surgery. This article provides an overview of the currently used interventional radiological procedures in lung oncology and assesses their importance. Further studies are needed to show whether interventional radiological procedures, which are promising due to their favourable risk-benefit ratio, may represent an alternative to radiotherapy or be effective in multimodal approaches.
Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/terapia , Neoplasias Pulmonares/secundario , Neoplasias Pulmonares/terapia , Radiología Intervencionista/instrumentación , Radiología Intervencionista/métodos , Nódulo Pulmonar Solitario/terapia , Adenocarcinoma/patología , Adenocarcinoma/terapia , Anciano , Neoplasias de la Mama/patología , Neoplasias de la Mama/terapia , Carcinoma de Pulmón de Células no Pequeñas/patología , Ablación por Catéter , Quimioterapia del Cáncer por Perfusión Regional/métodos , Criocirugía/métodos , Diatermia/métodos , Femenino , Humanos , Coagulación con Láser/métodos , Neoplasias Pulmonares/patología , Masculino , Microondas , Imagen Multimodal , Estadificación de Neoplasias , Tomografía de Emisión de Positrones , Nódulo Pulmonar Solitario/patología , Tomografía Computarizada por Rayos X , Resultado del TratamientoRESUMEN
PURPOSE: To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. MATERIALS AND METHODS: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. RESULTS: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. CONCLUSION: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle.