Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Microsc Microanal ; 30(4): 671-680, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-38993166

RESUMEN

We report application of the knife-edge technique at the sharp edges of WS2 and MoS2 monolayer flakes for lateral and axial resolution assessment in all three modalities of nonlinear laser scanning microscopy: two-photon excited fluorescence (TPEF), second- and third-harmonic generation (SHG, THG) imaging. This technique provides a high signal-to-noise ratio, no photobleaching effect and shows good agreement with standard resolution measurement techniques. Furthermore, we assessed both the lateral resolution in TPEF imaging modality and the axial resolution in SHG and THG imaging modality directly via the full-width at half maximum parameter of the corresponding Gaussian distribution. We comprehensively analyzed the factors influencing the resolution, such as the numerical aperture, the excitation wavelength and the refractive index of the embedding medium for the different imaging modalities. Glycerin was identified as the optimal embedding medium for achieving resolutions closest to the theoretical limit. The proposed use of WS2 and MoS2 monolayer flakes emerged as promising tools for characterization of nonlinear imaging systems.

2.
J Funct Biomater ; 15(1)2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-38248673

RESUMEN

Y0.8-xGdxF3:Yb/Er mesocrystals with a biocompatible surface and diverse morphological characteristics were successfully synthesized using chitosan-assisted solvothermal processing. Their structural properties, studied using X-ray powder diffraction, Fourier transform infrared spectroscopy, scanning and transmission electron microscopy and energy dispersive X-ray analysis, were further correlated with the up-conversion emission (λexc = 976 nm) recorded in function of temperature. Based on the change in the visible green emissions originating from the thermally coupled 2H11/2 and 4S3/2 levels of Er3+, the corresponding LIR was acquired in the physiologically relevant range of temperatures (25-50 °C). The detected absolute sensitivity of about 0.0042 °C-1, along with the low cytotoxicity toward both normal human lung fibroblasts (MRC-5) and cancerous lung epithelial (A549) cells, indicate a potential for use in temperature sensing in biomedicine. Additionally, their enhanced internalization in cells, without suppression of cell viability, enabled in vitro labeling of cancer and healthy cells upon 976 nm laser irradiation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...