Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Int J Cardiol ; 417: 132569, 2024 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-39303924

RESUMEN

BACKGROUND: Raphe-type bicuspid aortic valve (BAV) is a potential hostile scenario in trans-catheter aortic valve replacement (TAVR) due to pronounced calcium burden, possibly associated with tapered valve configuration. Trans-Catheter heart valve (THV) sizing strategy (annular vs. supra-annular) is controversial in this valve subtype. OBJECTIVES: To describe the phenotypical characteristics of severe, tapered, raphe-type, BAV stenosis undergoing TAVR and to explore safety and efficacy of modern-generation THVs, analysing the impact of annular and supra-annular sizing strategies on short- and mid-terms outcomes. METHODS: This is a retrospective, multicenter registry enrolling consecutive stenotic Sievers type 1 BAV treated with TAVR. Study population was divided into tapered and non-tapered configuration according to MSCT analysis. Matched comparison between annular and supra-annular sizing groups was performed in tapered population. RESULTS: From January 2016 to June 2023, 897 patients were enrolled. Of them, 696 patients displayed a tapered configuration. Of those, 510 received a THV according to annular sizing. After propensity score matching 186 matched pairs were selected. Technical success (96.2 % vs 94.1 %, OR 1.61 [0.61-4.24], p = 0.34), 30-day device success (83.6 % in both groups, OR 1.42 [0.78-2.57], p = 0.25) and 30-day early safety (71.8 % vs 70.5 %, OR 1.07 [0.68-1.68], p = 0.78) were similar between the annular and supra-annular sizing groups; a higher post-TAVR gradient was observed in supra-annular group, although it was only 2 mmHg mean. At mid-term follow-up, the rate of clinical efficacy was 84.7 %. CONCLUSIONS: TAVR with modern-generation devices is safe and effective for tapered raphe-type BAV, showing comparable results for annular and supra-annular sizing strategies.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Anciano , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Anciano de 80 o más Años , Resultado del Tratamiento , Diseño de Prótesis , Prótesis Valvulares Cardíacas , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Estudios de Seguimiento
2.
G Ital Cardiol (Rome) ; 25(6): 8-15, 2024 Jun.
Artículo en Italiano | MEDLINE | ID: mdl-38912742

RESUMEN

Coronary calcific disease represents one of the main challenges for the interventional cardiologist, for whom optimal lesion preparation and percutaneous coronary intervention optimization are paramount for correct management. In this perspective, intravascular imaging using optical coherence tomography (OCT) is becoming an increasingly indispensable tool. This work aims to provide a detailed overview of the complexity of calcified lesions, first analyzing their various morphologies and their clinical impact: spotty calcium seems to be more present in plaques at higher risk of destabilization, while diffuse calcification is typical of stable coronary stenosis; the eruptive calcific nodule is one of the three culprit lesion phenotypes responsible for acute coronary syndromes.In the second part of this review, the available technologies for the treatment of calcified lesions are described, with the aid of illustrative OCT images. Intravascular lithotripsy causes fractures at various levels of the calcified plaque, both circumferentially and longitudinally, with an improvement in vessel compliance; atherectomy acts by modifying the composition of the plaque with selective action on the hard calcific component. OCT, providing a comprehensive overview of lesion characteristics, can guide in the selection of the most appropriate therapeutic strategy, while also offering important information on the effectiveness of the chosen treatment.


Asunto(s)
Enfermedad de la Arteria Coronaria , Tomografía de Coherencia Óptica , Calcificación Vascular , Humanos , Tomografía de Coherencia Óptica/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia , Aterectomía Coronaria/métodos , Litotricia/métodos , Intervención Coronaria Percutánea/métodos , Placa Aterosclerótica/diagnóstico por imagen
3.
Am J Cardiol ; 224: 26-35, 2024 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-38844197

RESUMEN

New-generation transcatheter heart valves have significantly improved technical success and procedural safety of transcatheter aortic valve implantation (TAVI) procedures; however, the incidence of permanent pacemaker implantation (PPI) remains a concern. This study aimed to assess the role of anatomic annulus features in determining periprocedural conduction disturbances leading to new PPI after TAVI using the last-generation Edwards SAPIEN balloon-expandable valves. In the context of a prospective single-center registry, we integrated the clinical and procedural predictors of PPI with anatomic data derived from multislice computed tomography. A total of 210 consecutive patients treated with balloon-expandable Edwards transcatheter heart valve were included in the study from 2015 to 2023. Technical success was achieved in 197 procedures (93.8%), and 26 patients (12.4%) required new PPI at the 30-day follow-up (median time to implantation 3 days). At the univariable logistic regression analysis, preprocedural right bundle branch block (odds ratio [OR] 2.24, 95% confidence interval [CI] 1.01 to 4.97, p = 0.047), annulus eccentricity ≥0.25 (OR 5.43, 95% CI 2.21 to 13.36, p <0.001), calcium volume at annulus of the right coronary cusp >48 mm3 (OR 2.60, 95% CI 1.13 to 5.96, p = 0.024), and prosthesis implantation depth greater than membranous septum length (OR 2.17, 95% CI 1.10 to 4.28, p = 0.026) were associated with new PPI risk. In the multivariable analysis, preprocedural right bundle branch block (OR 2.81, 95% CI 1.01 to 7.85, p = 0.049), annulus eccentricity ≥0.25 (OR 4.14, 95% CI 1.85 to 9.27, p <0.001), and annulusright coronary cusp calcium >48 mm3 (OR 2.89, 95% CI 1.07 to 7.82, p = 0.037) were confirmed as independent predictors of new PPI. In conclusion, specific anatomic features of the aortic valve annulus might have an additive role in determining the occurrence of conduction disturbances in patients who underwent TAVI with balloon-expandable valves. This suggests the possibility to use multislice computed tomography to improve the prediction of post-TAVI new PPI risk.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Tomografía Computarizada Multidetector , Marcapaso Artificial , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Anciano de 80 o más Años , Tomografía Computarizada Multidetector/métodos , Estudios Prospectivos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Anciano , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Bloqueo de Rama/terapia , Bloqueo de Rama/etiología , Sistema de Registros
4.
Artículo en Inglés | MEDLINE | ID: mdl-38880697

RESUMEN

AIMS: The valve-in-valve transcatheter-aortic-valve-implantation (VIV-TAVI) represents an emerging procedure for the treatment of degenerated aortic bio-prostheses, and the occurrence of patient-prosthesis mismatch (PPM) after VIV-TAVI might affect its clinical efficacy. This study aimed to test a multimodal imaging approach to predict PPM risk during the TAVI planning phase and assess its clinical predictivity in VIV-TAVI procedures. METHODS: Consecutive patients undergoing VIV-TAVI procedures at our Institution over 6 years were screened and those treated by self-expandable supra-annular valves were selected. The effective orifice area (EOA) was calculated with a hybrid Gorlin equation combining echocardiographic data with invasive hemodynamic assessment. Severe PPM was defined according to such original multimodality assessment as EOAi≤0.65 cm2/m2 (if BMI < 30 kg/m2) or < 0.55 cm2/m2 (if BMI ≥ 30 kg/m2). The primary endpoint was a composite of all-cause mortality and valve-related re-hospitalization during the clinical follow-up. RESULTS: A total of 40 VIV-TAVI was included in the analysis. According to the pre-specified multimodal imaging modality assessment, 18 patients (45.0 %) had severe PPM. Among all baseline clinical and anatomical characteristics, estimated glomerular filtration rate before VIV-TAVI (OR 0.872, 95%CI[0.765-0.994],p = 0.040), the echocardiographic pre-procedural ≥moderate AR (OR 0.023, 95%CI[0.001-0.964],p = 0.048), the MSCT-derived effective internal area (OR 0.958, 95%CI[0.919-0.999],p = 0.046) and the implantation depth (OR 2.050, 95%CI[1.028-4.086],p = 0.041) resulted as independent predictors of severe PPM at multivariable logistic analysis. At a mean follow-up of 630 days, patients with severe PPM showed a higher incidence of the primary endpoint (9.1%vs.44.4 %;p = 0.023). CONCLUSION: In VIV-TAVI using self-expandable supra-annular valves, a multimodal imaging approach might improve clinical outcome predicting severe PPM occurrence.

5.
Int J Cardiol ; 410: 132218, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38815673

RESUMEN

BACKGROUND: The possibility to resheath some transcatheter heart valves (THV) facilitates the optimization of self-expandable devices implantation. However, resheating manoeuvres (expecially when repeated) increase the interaction between the transcatheter prosthesis and the patient's tissues potentially causing side-effects. AIMS: To assess the clinical outcomes of resheathing at midterm follow-up with a focus on the safety of multiple resheathing. METHODS: This retrospective observational study included all consecutive patients who underwent TAVI with a self-expandable supra-annular THV between December 2018 and December 2022. Primary endpoint was a composite of cardiovascular (CV) mortality, neurological events, non-fatal acute myocardial infarction and CV rehospitalizations. All clinical endpoints were assessed according to VARC-3 criteria. RESULTS: 469 TAVI procedures with self-expandable supra-annular THV were included in the study. The attempt to resheath and the resheath manoeuvres number was prospectively recorded into an electronic database. Resheating was attempted in 253 (53.9%) cases; 1, 2 and ≥ 3 resheathing were performed in respectively 122 (26.0%), 63 (13.4%) and 68 (14.5%) procedures. At a median follow-up of 640 days (interquartile range 340-1033 days), the incidence of the primary endpoint did not differ between 0 vs. ≥1 (22.7 vs. 26.1%, LogRank p = 0.584) and < 3 vs. ≥3 resheathing groups (24.2 vs. 26.5% LogRank p = 0.963). Furthermore, no significant differences in the primary endpoint were observed between 0, 1-2 and ≥ 3 resheathing (p = 0.84). CONCLUSIONS: Our study found that resheathing of self-expandable THVs during TAVI did not result in worse clinical outcomes compared with no resheathing at mid-term follow-up. These results are independent from the number of resheathing, underling the safety of multiple resheathing in terms of peri-procedural and mid-term outcome. CONDENSED ABSTRACT: In this retrospective observational study of 469 patients undergoing transcatheter aortic valve implantation (TAVI) for symptomatic severe aortic stenosis with self-expanding valves, we investigated the influence of resheathing on mid-term clinical outcomes. Specifically, we focused on the safety of multiple resheathing procedures. Our findings revealed no significant impact of resheathing on medium-term outcomes. The primary endpoint, a composite of cardiovascular mortality, neurological events, non-fatal acute myocardial infarction, and cardiovascular rehospitalizations, did not show statistically significant differences between no resheathing, single resheathing and multiple resheathing groups. Our study suggests that resheathing, even when performed multiple times, does not appear to significantly affect clinical outcomes at mid-term follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Masculino , Femenino , Estudios Retrospectivos , Anciano de 80 o más Años , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estudios de Seguimiento , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...