Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(12)2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38931778

RESUMEN

Transition-edge sensor (TES) microcalorimeters are advanced cryogenic detectors that use a superconducting film for particle or photon detection. We are establishing a new production line for TES detectors to serve as cryogenic anticoincidence (i.e., veto) devices. These detectors are made with a superconducting bilayer of titanium (Ti) and gold (Au) thin films deposited via electron beam evaporation in a high vacuum condition on a monocrystalline silicon substrate. In this work, we report on the development of such sensors, aiming to achieve stable sensing performance despite the effects of aging. For this purpose, patterned and non-patterned Ti/Au bilayer samples with varying geometries and thicknesses were fabricated using microfabrication technology. To characterize the detectors, we present and discuss initial results from repeated resistance-temperature (R-T) measurements over time, conducted on different samples, thereby augmenting existing literature data. Additionally, we present a discussion of the sensor's degradation over time due to aging effects and test a potential remedy based on an easy annealing procedure. In our opinion, this work establishes the groundwork for our new TES detector production line.

2.
Micromachines (Basel) ; 14(12)2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38138399

RESUMEN

This paper investigates how the electromechanical response of MEMS/NEMS devices changes when the geometrical characteristics of their embedded flexural hinges are modified. The research is dedicated particularly to MEMS/NEMS devices which are actuated by means of rotary comb-drives. The electromechanical behavior of a chosen rotary device is assessed by studying the rotation of the end effector, the motion of the comb-drive mobile fingers, the actuator's maximum operating voltage, and the stress sustained by the flexure when the flexure's shape, length, and width change. The results are compared with the behavior of a standard revolute joint. Outcomes demonstrate that a linear flexible beam cannot perfectly replace the revolute joint as it induces a translation that strongly facilitates the pull-in phenomenon and significantly increases the risk of ruptures of the comb-drives. On the other hand, results show how curved beams provide a motion that better resembles the revolute motion, preserving the structural integrity of the device and avoiding the pull-in phenomenon. Finally, results also show that the end effector motion approaches most precisely the revolute motion when a fine tuning of the beam's length and width is performed.

3.
Sensors (Basel) ; 23(19)2023 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-37837014

RESUMEN

This work presents a compact and sensitive refractive index sensor able to evaluate the concentration of an analyte in a sample. Its working principle leverages on the changes in the optical absorption features introduced by the sample itself on the evanescent waves of a light beam. The device's high compactness is achieved by embedding the sample-light interaction site and the detector in a 1 cm2 glass substrate, thanks to microelectronics technologies. High sensitivity is obtained by employing a low-noise p-i-n hydrogenated amorphous silicon junction, whose manufacture process requires only four UV lithographic steps on a glass substrate, thus ensuring low production costs. The system's capabilities are investigated by sensing the sugar content in three commercial beverages. Sensitivities of 32, 53 and 80 pA/% and limits of detection of 47, 29 and 18 ppm are achieved. The above performance is comparable with state-of-the-art results available in the literature, where more complex optical setups, expensive instrumentation and bulky devices are used.

4.
Materials (Basel) ; 16(17)2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37687519

RESUMEN

This work focuses on the possible application of gold nanoparticles on flexible cotton fabric as acetone- and ethanol-sensitive substrates by means of impedance measurements. Specifically, citrate- and polyvinylpyrrolidone (PVP)-functionalized gold nanoparticles (Au NPs) were synthesized using green and well-established procedures and deposited on cotton fabric. A complete structural and morphological characterization was conducted using UV-VIS and Fourier transform infrared (FT-IR) spectroscopy, atomic force microscopy (AFM), and scanning electron microscopy (SEM). A detailed dielectric characterization of the blank substrate revealed interfacial polarization effects related to both Au NPs and their specific surface functionalization. For instance, by entirely coating the cotton fabric (i.e., by creating a more insulating matrix), PVP was found to increase the sample resistance, i.e., to decrease the electrical interconnection of Au NPs with respect to citrate functionalized sample. However, it was observed that citrate functionalization provided a uniform distribution of Au NPs, which reduced their spacing and, therefore, facilitated electron transport. Regarding the detection of volatile organic compounds (VOCs), electrochemical impedance spectroscopy (EIS) measurements showed that hydrogen bonding and the resulting proton migration impedance are instrumental in distinguishing ethanol and acetone. Such findings can pave the way for the development of VOC sensors integrated into personal protective equipment and wearable telemedicine devices. This approach may be crucial for early disease diagnosis based on nanomaterials to attain low-cost/low-end and easy-to-use detectors of breath volatiles as disease markers.

5.
Sensors (Basel) ; 23(9)2023 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-37177399

RESUMEN

Zinc oxide (ZnO) thin films have been grown by radio frequency sputtering technique on fused silica substrates. Optical and morphological characteristics of as-grown ZnO samples were measured by various techniques; an X-ray diffraction spectrum showed that the films exhibited hexagonal wurtzite structure and were c-axis-oriented normal to the substrate surface. Scanning electron microscopy images showed the dense columnar structure of the ZnO layers, and light absorption measurements allowed us to estimate the penetration depth of the optical radiation in the 200 to 480 nm wavelength range and the ZnO band-gap. ZnO layers were used as a basic material for surface acoustic wave (SAW) delay lines consisting of two Al interdigitated transducers (IDTs) photolithographically implemented on the surface of the piezoelectric layer. The Rayleigh wave propagation characteristics were tested in darkness and under incident UV light illumination from the top surface of the ZnO layer and from the fused silica/ZnO interface. The sensor response, i.e., the wave velocity shift due to the acoustoelectric interaction between the photogenerated charge carriers and the electric potential associated with the acoustic wave, was measured for different UV power densities. The reversibility and repeatability of the sensor responses were assessed. The time response of the UV sensor showed a rise time and a recovery time of about 10 and 13 s, respectively, and a sensitivity of about 318 and 341 ppm/(mW/cm2) for top and bottom illumination, respectively. The ZnO/fused silica-based SAW UV sensors can be interrogated across the fused silica substrate thanks to its optical transparency in the UV range. The backlighting interrogation can find applications in harsh environments, as it prevents the sensing photoconductive layer from aggressive environmental effects or from any damage caused by cleaning the surface from dust which could deteriorate the sensor's performance. Moreover, since the SAW sensors, by their operating principle, are suitable for wireless reading via radio signals, the ZnO/fused-silica-based sensors have the potential to be the first choice for UV sensing in harsh environments.

6.
Sensors (Basel) ; 24(1)2023 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-38202961

RESUMEN

In the food industry, there is a growing demand for cost-effective methods for the inline inspection of food items able to non-invasively detect small foreign bodies that may have contaminated the product during the production process. Microwave imaging may be a valid alternative to the existing technologies, thanks to its inherently low-cost and its capability of sensing low-density contaminants. In this paper, a simple microwave imaging system specifically designed to enable the inspection of a large variety of food products is presented. The system consists of two circularly loaded antipodal Vivaldi antennas with a very large operative band, from 1 to 15 GHz, thus allowing a suitable spatial resolution for different food products, from mostly fatty to high water-content foods. The antennas are arranged in such a way as to collect a signal that can be used to exploit a recently proposed real-time microwave imaging strategy, leveraging the inherent symmetries that usually characterize food items. The system is experimentally characterized, and the achieved results compare favorably with the design specifications and numerical simulations. Relying on these positive results, the first experimental proof of the effectiveness of the entire system is presented confirming its efficacy.


Asunto(s)
Imágenes de Microonda , Alimentos , Microondas , Tecnología , Agua
7.
Sci Rep ; 12(1): 16796, 2022 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-36207345

RESUMEN

Due to the SARS-CoV-2 outbreak, wearing a disposable face mask has become a worldwide daily routine, not only for medical operators or specialized personnel, but also for common people. Notwithstanding the undeniable positive effect in reducing the risk of virus transmission, it is important to understand if a prolonged usage of the same face mask can have effectiveness on filtering capability and potential health consequences. To this aim, we present three investigations. A survey, carried out in central Italy, offers an overview of the distorted public awareness of face mask usage. A functional study shows how prolonged wearing leads to substantial drops in humid air filtration efficiency. Finally, a morphological analysis reports the proliferation of fungal or bacteria colonies inside an improperly used mask. Our study highlights therefore that wearing a face mask is really beneficial only if it is used correctly.


Asunto(s)
COVID-19 , Máscaras , COVID-19/epidemiología , COVID-19/prevención & control , Filtración , Humanos , Máscaras/efectos adversos , SARS-CoV-2 , Encuestas y Cuestionarios
8.
Sensors (Basel) ; 21(2)2021 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-33430165

RESUMEN

An optoelectronic, integrated system-on-glass for on-chip detection of biomolecules is here presented. The system's working principle is based on the interaction, detected by a hydrogenated amorphous silicon photosensor, between a monochromatic light travelling in a SU-8 polymer optical waveguide and the biological solution under analysis. Optical simulations of the waveguide coupling to the thin-film photodiode with a specific design were carried out. A prototype was fabricated and characterized showing waveguide optical losses of about 0.6 dB/cm, a photodiode shot noise current of about 2.5 fA/Hz and responsivity of 495 mA/W at 532 nm. An electro-optical coupling test was performed on the fabricated device to validate the system. As proof of concept, hemoglobin was studied as analyte for a demonstration scenario, involving optical simulations interpolated with experimental data. The calculated detection limit of the proposed system for hemoglobin concentration in aqueous solution is around 100 ppm, in line with colorimetric methods currently on the market. These results show the effectiveness of the proposed system in biological detection applications and encourage further developments in implementing these kinds of devices in the biomedical field.


Asunto(s)
Vidrio , Silicio , Colorimetría , Estudios de Factibilidad , Hemoglobinas
9.
Micromachines (Basel) ; 11(12)2020 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-33302376

RESUMEN

This paper presents the development of a multi-hinge, multi-DoF (Degrees of Freedom) nanogripper actuated by means of rotary comb drives and equipped with CSFH (Conjugate Surface Flexure Hinges), with the goal of performing complex in-plane movements at the nanoscale. The design approach, the simulation and a specifically conceived single-mask fabrication process are described in detail and the achieved results are illustrated by SEM images. The first prototype presents a total overall area of (550 × 550) µm2, an active clamping area of (2 × 4) µm2, 600 nm-wide circular curved beams as flexible hinges for its motion and an aspect ratio of about 2.5. These features allow the proposed system to grasp objects a few hundred nanometers in size.

10.
Micromachines (Basel) ; 10(7)2019 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-31262087

RESUMEN

The micromanipulation of micro objects is nowadays the focus of several investigations, specially in biomedical applications. Therefore, some manipulation tasks are required to be in aqueous environment and become more challenging because they depend upon observation and actuation methods that are compatible with MEMS Technology based micromanipulators. This paper describes how three grasping-releasing based tasks have been successfully applied to agarose micro beads whose average size is about 60 µ m: (i) the extraction of a single micro bead from a water drop; (ii) the insertion of a single micro bead into the drop; (iii) the grasping of a single micro bead inside the drop. The success of the performed tasks rely on the use of a microgripper previously designed, fabricated, and tested.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...