Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Front Microbiol ; 13: 910156, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35783392

RESUMEN

During the first few months of the global Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) pandemic, the medical research community had to expeditiously develop, select, and deploy novel diagnostic methods and tools to address the numerous testing challenges presented by the novel virus. Integrating a systematic approach to diagnostic selection with a rapid validation protocol in a clinical setting can shorten the timeline to bring new technologies to practice. In response to the urgent need to provide tools for identifying SARS-CoV-2-positive individuals, we developed a framework for assessing technologies against a set of prioritized performance metrics to guide device selection. We also developed and proposed clinical validation frameworks for the rapid screening of new technologies. The rubric described here represents a versatile approach that can be extended to future technology assessments and can be implemented in preparation for future emerging pathogens.

2.
Front Physiol ; 12: 691074, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34552498

RESUMEN

Background and Objectives: Early warning of bacterial and viral infection, prior to the development of overt clinical symptoms, allows not only for improved patient care and outcomes but also enables faster implementation of public health measures (patient isolation and contact tracing). Our primary objectives in this effort are 3-fold. First, we seek to determine the upper limits of early warning detection through physiological measurements. Second, we investigate whether the detected physiological response is specific to the pathogen. Third, we explore the feasibility of extending early warning detection with wearable devices. Research Methods: For the first objective, we developed a supervised random forest algorithm to detect pathogen exposure in the asymptomatic period prior to overt symptoms (fever). We used high-resolution physiological telemetry data (aortic blood pressure, intrathoracic pressure, electrocardiograms, and core temperature) from non-human primate animal models exposed to two viral pathogens: Ebola and Marburg (N = 20). Second, to determine reusability across different pathogens, we evaluated our algorithm against three independent physiological datasets from non-human primate models (N = 13) exposed to three different pathogens: Lassa and Nipah viruses and Y. pestis. For the third objective, we evaluated performance degradation when the algorithm was restricted to features derived from electrocardiogram (ECG) waveforms to emulate data from a non-invasive wearable device. Results: First, our cross-validated random forest classifier provides a mean early warning of 51 ± 12 h, with an area under the receiver-operating characteristic curve (AUC) of 0.93 ± 0.01. Second, our algorithm achieved comparable performance when applied to datasets from different pathogen exposures - a mean early warning of 51 ± 14 h and AUC of 0.95 ± 0.01. Last, with a degraded feature set derived solely from ECG, we observed minimal degradation - a mean early warning of 46 ± 14 h and AUC of 0.91 ± 0.001. Conclusion: Under controlled experimental conditions, physiological measurements can provide over 2 days of early warning with high AUC. Deviations in physiological signals following exposure to a pathogen are due to the underlying host's immunological response and are not specific to the pathogen. Pre-symptomatic detection is strong even when features are limited to ECG-derivatives, suggesting that this approach may translate to non-invasive wearable devices.

3.
SLAS Technol ; 23(2): 164-171, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29186668

RESUMEN

Gut-on-a-chip in vitro modeling is an emerging field, as the human gut epithelium and gut microbiome have been recently identified as novel drug targets for a wide variety of diseases. Realistic in vitro gut models require a variety of precise environmental cues, such as chemical and gas gradients, in combination with substrates like mucus that support the growth of microbial communities. This technical brief describes a microfluidic architecture capable of developing a physiologically relevant oxygen gradient that emulates the oxygen profile proximal to the epithelial inner lining of the human colon. The device generates stable and repeatable defined oxygen gradients from 0% to 4 % partial pressure O2 over a length scale of hundreds of microns, and was applied to study the effects of oxygenation on the structure of native mucus that lines the colon wall. Using simulation as a design tool for hybrid gas-liquid microfluidic devices enables on-chip creation of defined, physiologically oxygen gradients. These microfluidic architectures have powerful potential applications for gut physiology, including providing optimal oxygenation conditions for the culture of mammalian epithelial cells in the gut lining, as well as creating a realistic mimic of the oxygen gradient found in the intestinal lumen for complex microbiome cultures.


Asunto(s)
Colon/química , Colon/fisiología , Dispositivos Laboratorio en un Chip , Oxígeno/metabolismo , Humanos , Modelos Biológicos , Moco/química , Presión Parcial
4.
Adv Drug Deliv Rev ; 55(3): 349-77, 2003 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-12628321

RESUMEN

Significant advances have been made in the development of micro-scale technologies for biomedical and drug discovery applications. The first generation of microfluidics-based analytical devices have been designed and are already functional. Microfluidic devices offer unique advantages in sample handling, reagent mixing, separation, and detection. We introduce and review microfluidic concepts, microconstruction techniques, and methods such as flow-injection analysis, electrokinesis, and cell manipulation. Advances in micro-device technology for proteomics, sample preconditioning, immunoassays, electrospray ionization mass spectrometry, and polymerase chain reaction are also reviewed.


Asunto(s)
Microquímica/instrumentación , Microquímica/métodos , Tecnología Farmacéutica/instrumentación , Tecnología Farmacéutica/métodos , Animales , Humanos , Microquímica/tendencias , Tecnología Farmacéutica/tendencias
5.
Electrophoresis ; 23(16): 2642-52, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12210168

RESUMEN

The formation of the liquid junction potential (LJP) is a well-studied phenomenon that occurs in the presence of ionic concentration gradients. Although the LJP has been well characterized, its impact has generally been overlooked in microfluidic applications. The characteristics of flow in microfluidic channels cause this phenomenon to be particularly important, both as a source of deviation from anticipated results and as a tool capable of being harnessed to perform useful tasks. It is demonstrated that LJPs formed in microchannels can induce appreciable electrophoretic transport of charged species without the use of electrodes or an external power supply. This process is demonstrated in an H-filter (an H-shaped microfluidic channel used to bring two fluids into contact allowing extraction of diffusing species from one stream to another) by generating junction potentials between two flowing streams containing different concentrations of strong electrolytes and observing the mass transport of the charged dye fluorescein between those streams. It is shown that the LJP can be controlled to either accelerate or decelerate mass transport across a fluid interface in the absence of an interposed membrane. A preliminary mathematical description of the phenomena is offered to support the hypothesis that the observed mass transport is a result of the LJP. Possible practical microfluidic applications of electrophoretic transport without electrodes are discussed.


Asunto(s)
Electrólitos/química , Electroforesis Capilar/instrumentación , Electroforesis Capilar/métodos , Difusión , Fluoresceína/análisis , Procesamiento de Imagen Asistido por Computador , Miniaturización , Reología , Silicio , Cloruro de Sodio/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...