Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Intervalo de año de publicación
1.
Environ Sci Pollut Res Int ; 30(48): 106660-106670, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37733200

RESUMEN

Crucial information on the pandemic's spread has been gathered by monitoring the trend of SARS-CoV-2 in wastewater. This surveillance has highlighted that the initial concentration is a critical step of the analytical procedure due to the low viral titer that may be present in this matrix. This paper presents the results of the evaluation of two different wastewater concentration protocols to determine the most efficient and cost-effective. The two methods tested were the following: (a) a biphasic separation system with PEG-dextran and (b) a PEG/NaCl precipitation protocol. Other aspects of the detection method were also investigated including the influence of storage temperature on virus recovery and the heat treatment of pasteurization, which aims to make samples safer for operators and the environment. The PEG/NaCl precipitation method was found to perform better than the biphasic separation system, allowing for more sensitive identification of the presence of the virus and the detection of a higher viral titer than that identified with the biphasic separation in all results. Storage of the samples at 4.3±0.2°C for up to 3 weeks did not adversely affect the virus titer and the pasteurization pre-treatment increases operator safety and maintains the identification of the viral concentration.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Cloruro de Sodio , Aguas Residuales , Pasteurización
2.
Environ Technol Innov ; 28: 102667, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35615435

RESUMEN

This paper highlights the extraordinarily rapid spread of SARS-CoV-2 loads in wastewater that during the Omicron wave in December 2021-February 2022, compared with the profiles acquired in 2020-21 with 410 samples from two wastewater treatment plants (Trento+suburbs, 132,500 inhabitants). Monitoring of SARS-CoV-2 in wastewater focused on: (i) 3 samplings/week and analysis, (ii) normalization to calculate genomic units (GU) inh-1 d-1; (iii) calculation of a 7-day moving average to smooth daily fluctuations; (iv) comparison with the 'current active cases'/100,000 inh progressively affected by the mass vaccination. The time profiles of SARS-CoV-2 in wastewater matched the waves of active cases. In February-April 2021, a viral load of 1.0E+07 GU inh-1 d - 1 corresponded to 700 active cases/100,000 inh. In July-September 2021, although the low current active cases, sewage revealed an appreciable SARS-CoV-2 circulation (in this period 2.2E+07 GU inh-1 d-1 corresponded to 90 active cases/100,000 inh). Omicron was not detected in wastewater until mid-December 2021. The Omicron spread caused a 5-6 fold increase of the viral load in two weeks, reaching the highest peak (2.0-2.2E+08 GU inh-1 d-1 and 4500 active cases/100,000 inh) during the pandemic. In this period, wastewater surveillance anticipated epidemiological data by about 6 days. In winter 2021-22, despite the 4-7 times higher viral loads in wastewater, hospitalizations were 4 times lower than in winter 2020-21 due to the vaccination coverage >80%. The Omicron wave demonstrated that SARS-CoV-2 monitoring of wastewater anticipated epidemiological data, confirming its importance in long-term surveillance.

3.
Environ Res ; 207: 112204, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-34656637

RESUMEN

The fate of Coronaviruses (CoVs) and in particular SARS-CoV-2 in wastewater treatment plants (WWTPs) has not been completely understood yet, but an adequate knowledge on the removal performances in WWTPs could help to prevent waterborne transmission of the virus that is still under debate. CoVs and SARS-CoV-2 are discharged from faeces into the sewer network and reach WWTPs within a few hours. This review presents the fate of SARS-CoV-2 and other CoVs in the primary, secondary and tertiary treatments of WWTPs as well as in sludge treatments. The viral loads decrease progressively along with the treatments from 20 to 3.0E+06 GU/L (Genomic Units/L) in the influent wastewater to concentrations below 2.50E+05 GU/L after secondary biological treatments and finally to negative concentrations (below detection limit) in disinfected effluents. Reduction of CoVs is due to (i) natural decay under unfavourable conditions (solids, microorganisms, temperature) for relatively long hydraulic retention times and (ii) processes of sedimentation, filtration, predation, adsorption, disinfection. In primary and secondary settling, due to the hydrophobic properties, a partial accumulation of CoVs may occur in the separated sludge. In secondary treatment (i.e. activated sludge) CoVs and SARS-CoV-2 loads can be reduced only by about one logarithm (∼90%). To enhance this removal, tertiary treatment with ultrafiltration (Membrane Bioreactors) and chemical disinfection or UV light is needed. CoVs and SARS-CoV-2 in the sludge (1.2E+04-4.6E+08 GU/L) can be inactivated significantly in the thermophilic digestion (55 °C), while mesophilic temperatures (33-37 °C) are not efficient. Additional studies are required to investigate the infectivity of SARS-CoV-2 in WWTPs, especially in view of increasing interest in wastewater reclamation and reuse.


Asunto(s)
COVID-19 , Purificación del Agua , Humanos , SARS-CoV-2 , Aguas del Alcantarillado , Aguas Residuales
4.
Chemosphere ; 164: 488-498, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27614985

RESUMEN

A laboratory-scale sequencing batch reactor (SBR) performing partial nitritation - anammox and denitrification was used to treat anaerobic digester effluents. The SBR cycle consisted of a short mixing filling phase followed by oxic and anoxic reaction phases. Working at 25 °C, an ammonium conversion efficiency of 96.5%, a total nitrogen removal efficiency of 88.6%, and an organic carbon removal efficiency of 63.5% were obtained at a nitrogen loading rate of 0.15 kg N m-3 d-1, and a biodegradable organic carbon to nitrogen ratio of 0.37. The potential contribution of each biological process was evaluated by using a stoichiometric model. The nitritation contribution decreased as the temperature decreased, while the contribution from anammox depended on the wastewater type and soluble carbon to nitrogen ratio. Denitrification improved the total nitrogen removal efficiency, and it was influenced by the biodegradable organic carbon to nitrogen ratio. The characteristic patterns of conductivity, oxidation-reduction potential (ORP) and pH in the SBR cycle were well related to biological processes. Conductivity profiles were found to be directly related to the decreasing profiles of ammonium. Positive ORP values at the end of the anoxic phases were detected for total nitrogen removal efficiency of lower than 85%, and the occurrence of bending points on the ORP curves during the anoxic phases was associated with nitrite depletion by the anammox process.


Asunto(s)
Compuestos de Amonio/análisis , Reactores Biológicos , Nitritos/análisis , Nitrógeno/análisis , Sistemas en Línea , Aguas Residuales/análisis , Contaminantes Químicos del Agua/análisis , Compuestos de Amonio/aislamiento & purificación , Desnitrificación , Monitoreo del Ambiente/métodos , Nitritos/aislamiento & purificación , Nitrógeno/aislamiento & purificación , Contaminantes Químicos del Agua/aislamiento & purificación , Purificación del Agua/métodos
5.
Eng. sanit. ambient ; 10(1): 14-23, jan.-mar. 2005. ilus, tab, graf
Artículo en Portugués | LILACS | ID: lil-406833

RESUMEN

Este trabalho apresenta os atuais métodos respirométricos voltados ao controle biológico em geral, com técnicas desenvolvidas para a aplicação em tratamentos de águas residuárias, principalmente no controle de processos por lodos ativados e recentes desenvolvimentos do método para a aplicação em sistemas de tratamento por fitodepuração (Wetlands). Descreve novos métodos que foram desenvolvidos no Laboratorio di Ingegneria Sanitaria-Ambientale (LISA) da Università di Trento, Itália. Estes métodos baseiam-se em duas metodologias de laboratório para a aplicação da respirometria em fitoderuração: o primeiro caracteriza a atividade bacteriológica do solo com a finalidade de medir a concentração de O2 na fase gasosa, o outro avalia a concentração de O2 na fase aquosa.


Asunto(s)
Lodos Activados , Aguas Residuales , Monitoreo del Ambiente , Fenómenos Biológicos , Monitoreo del Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...