1.
Hand Surg Rehabil ; 43(3): 101686, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38583707

RESUMEN

De Quervain's tenosynovitis is the most common complication after total trapeziometacarpal joint replacement. Etiology is unclear. Implantation of a ball-in-socket implant changes the biomechanics of the normal trapeziometacarpal saddle joint and increases its range of motion. The present study demonstrates that this procedure also significantly increases excursion of the abductor pollicis longus and extensor pollicis brevis tendons during thumb flexion-extension, and not during thumb abduction-adduction. Increased tendon gliding under the retinaculum of the first extensor tendon compartment could predispose to the development frictional tenosynovitis and play a role in the development of de Quervain's syndrome after total trapeziometacarpal joint replacement. LEVEL OF EVIDENCE: Not applicable (laboratory study).


Asunto(s)
Artroplastia de Reemplazo , Articulaciones Carpometacarpianas , Enfermedad de De Quervain , Tendones , Humanos , Tendones/fisiopatología , Tendones/cirugía , Articulaciones Carpometacarpianas/fisiopatología , Articulaciones Carpometacarpianas/cirugía , Enfermedad de De Quervain/fisiopatología , Enfermedad de De Quervain/cirugía , Fenómenos Biomecánicos , Femenino , Rango del Movimiento Articular , Masculino , Persona de Mediana Edad , Hueso Trapecio/cirugía , Hueso Trapecio/fisiopatología , Anciano , Prótesis Articulares , Complicaciones Posoperatorias/fisiopatología
2.
Acta Orthop Belg ; 90(1): 67-71, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38669652

RESUMEN

The goal of the present study was to evaluate the incidence of infection after perioperative intra-articular steroid injection during elbow arthroscopy. Starting from May 2019, we prospectively included all patients that underwent an elbow arthroscopy for various indications. All patients received preoperative antibiotics intravenously and a corticosteroid injection immediately after portal closure. Patients who needed ligamentous repair and aged below 18 years old were excluded. Final follow up of all patients was 3 months. In total, 108 elbow arthroscopies were performed in 100 patients. No major complications and 1 minor complication were seen. One patient developed a seroma that resolved spontaneously after 14 days without intervention or antibiotics. In this patient group, a perioperative corticosteroid injection following elbow arthroscopy did not increase the chance of infection.


Asunto(s)
Artroscopía , Articulación del Codo , Humanos , Artroscopía/métodos , Artroscopía/efectos adversos , Articulación del Codo/cirugía , Masculino , Inyecciones Intraarticulares , Femenino , Adulto , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven , Corticoesteroides/administración & dosificación , Corticoesteroides/efectos adversos , Anciano , Adolescente , Atención Perioperativa/métodos , Infección de la Herida Quirúrgica/prevención & control , Infección de la Herida Quirúrgica/epidemiología , Glucocorticoides/administración & dosificación
3.
Acta Orthop Belg ; 89(4): 691-694, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38205762

RESUMEN

Fractures of the phalanges may result in a challenging complication known as malrotation, which can adversely affect the functionality of the fingers during flexion, leading to scissoring. The standard surgical approach for correcting this condition involves open corrective osteotomy and derotation, often at the level of the metacarpal, which includes the use of different techniques for osteotomy and fixation. However, postoperative complications such as finger stiffness and hardware irritation are common. To overcome these limitations, we present a novel and minimally invasive corrective osteotomy technique for malunited proximal phalanx fractures with rotational malalignment, which offers several advantages, such as accelerated rehabilitation and no prominent hardware.


Asunto(s)
Fracturas Óseas , Osteotomía , Humanos , Ácido Dioctil Sulfosuccínico , Dedos , Fenolftaleína
4.
Acta Orthop Belg ; 89(4): 695-700, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38205763

RESUMEN

Complete distal biceps tendon ruptures are relatively uncommon. Conservative treatment may result in persistent pain and weakness. Therefore, surgical repair is usually indicated in order to restore strength. Different surgical techniques and fixation methods have been described. The most reported complications after surgery are iatrogenic nerve damage, heterotopic ossification (HO) and re-rupture. Heterotopic ossification can be variable in size. Significant HO can limit range of motion while minor HO often remains asymptomatic. The overall presence of HO is likely underreported in literature, as imaging is reserved for symptomatic patients. The purpose of this study is to report the prevalence and clinical implications of heterotopic ossification after surgical repair of the distal biceps tendon. This retrospective study assessed the prevalence and clinical relevance of postoperative HO after distal biceps tendon repair. CT-scans were used to evaluate size and location of the HO. VAS scores, DASH scores, MEPI, and range of motion (ROM) were assessed to evaluate pain, patient satisfaction and elbow function. HO was observed on CT images of 19 out of 35 patients (54%). The use of interference screws, timing of surgery after rupture and timing of radiographic assessment postoperatively did not influence the prevalence of HO. The presence of HO had no statistically significant impact on the VAS scores, ROM measurements and MEPI and DASH scores. According to our findings, the overall incidence of HO is higher than previously reported but there are no differences in clinical outcomes when compared to patients without HO.


Asunto(s)
Codo , Dolor , Humanos , Prevalencia , Estudios Retrospectivos , Tendones
7.
Hand Surg Rehabil ; 39(5): 413-416, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32387691

RESUMEN

It has been suggested that trapeziometacarpal total joint arthroplasty be combined with complete release of the joint capsule to prevent ligament tethering and implant dislocation. Our goal was to evaluate the consequences of capsular release on range of motion. Trapeziometacarpal joint motion was measured with a 3D motion tracking system in seven fresh frozen human cadaver hands before and after capsular release and total joint arthroplasty with subsequently longer neck lengths. Relative to the native trapeziometacarpal joint with intact joint capsule, mean flexion-extension was significantly increased after the arthroplasty with released capsule and lengthening up to 6 mm. Mean abduction-adduction did not increase significantly. Total joint replacement combined with capsular release increases the trapeziometacarpal joint's range of motion, but not beyond the limits of most trapeziometacarpal implant designs. Lengthening of the implant neck progressively decreases the excess motion.


Asunto(s)
Artroplastia de Reemplazo , Articulaciones Carpometacarpianas/cirugía , Liberación de la Cápsula Articular , Rango del Movimiento Articular , Anciano , Anciano de 80 o más Años , Cadáver , Femenino , Humanos , Masculino
8.
J Hand Surg Eur Vol ; 41(9): 939-943, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26896453

RESUMEN

In trapeziometacarpal arthroplasty, correct implant position may be necessary to prevent complications such as dislocation, component loosening and premature wear. The metacarpal stem more easily fits anatomically. However, the cup in the trapezium is not anatomical and guidelines for its orientation are not uniformly defined. We determined the centre of the range of motion of the trapeziometacarpal joint in 30 healthy patients on postero-anterior and lateral radiographs and its relationship to the proximal articular surface of the trapezium. Our study suggests that in thumb carpo-metacarpal total joint arthroplasty, the prosthetic cup in the trapezium should be placed parallel to the proximal articular surface of the trapezium and combined with a metacarpal neck with 7° palmar offset. This should optimize arthroplasty ranges of motion and may minimize the risk of postoperative complications. Our study provides a reference for the surgeon to check correct cup alignment intra-operatively with fluoroscopy.


Asunto(s)
Artroplastia de Reemplazo , Articulaciones Carpometacarpianas/anatomía & histología , Articulaciones Carpometacarpianas/diagnóstico por imagen , Pulgar , Hueso Trapecio/anatomía & histología , Hueso Trapecio/diagnóstico por imagen , Adulto , Anciano , Articulaciones Carpometacarpianas/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Rango del Movimiento Articular , Valores de Referencia , Hueso Trapecio/cirugía , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...