RESUMEN
Objective.The Utah array is widely used in both clinical studies and neuroscience. It has a strong track record of safety. However, it is also known that implanted electrodes promote the formation of scar tissue in the immediate vicinity of the electrodes, which may negatively impact the ability to record neural waveforms. This scarring response has been primarily studied in rodents, which may have a very different response than primate brain.Approach.Here, we present a rare nonhuman primate histological dataset (n= 1 rhesus macaque) obtained 848 and 590 d after implantation in two brain hemispheres. For 2 of 4 arrays that remained within the cortex, NeuN was used to stain for neuron somata at three different depths along the shanks. Images were filtered and denoised, with neurons then counted in the vicinity of the arrays as well as a nearby section of control tissue. Additionally, 3 of 4 arrays were imaged with a scanning electrode microscope to evaluate any materials damage that might be present.Main results.Overall, we found a 63% percent reduction in the number of neurons surrounding the electrode shanks compared to control areas. In terms of materials, the arrays remained largely intact with metal and Parylene C present, though tip breakage and cracks were observed on many electrodes.Significance.Overall, these results suggest that the tissue response in the nonhuman primate brain shows similar neuron loss to previous studies using rodents. Electrode improvements, for example using smaller or softer probes, may therefore substantially improve the tissue response and potentially improve the neuronal recording yield in primate cortex.
Asunto(s)
Corteza Cerebral , Neuronas , Animales , Macaca mulatta , Utah , Microelectrodos , Corteza Cerebral/fisiología , Electrodos ImplantadosRESUMEN
OBJECTIVE: Multimodal measurements at the neuronal level allow for detailed insight into local circuit function. However, most behavioral studies focus on one or two modalities and are generally limited by the available technology. APPROACH: Here, we show a combined approach of electrophysiology recordings, chemical sensing, and histological localization of the electrode tips within tissue. The key enabling technology is the underlying use of carbon fiber electrodes, which are small, electrically conductive, and sensitive to dopamine. The carbon fibers were functionalized by coating with Parylene C, a thin insulator with a high dielectric constant, coupled with selective re-exposure of the carbon surface using laser ablation. MAIN RESULTS: We demonstrate the use of this technology by implanting 16 channel arrays in the rat nucleus accumbens. Chronic electrophysiology and dopamine signals were detected 1 month post implant. Additionally, electrodes were left in the tissue, sliced in place during histology, and showed minimal tissue damage. SIGNIFICANCE: Our results validate our new technology and methods, which will enable a more comprehensive circuit level understanding of the brain.
Asunto(s)
Carbono , Fenómenos Electrofisiológicos , Animales , Fibra de Carbono , Electrodos , Electrofisiología , Microelectrodos , RatasRESUMEN
Neural implants with large numbers of electrodes have become an important tool for examining brain functions. However, these devices typically displace a large intracranial volume compared with the neurons they record. This large size limits the density of implants, provokes tissue reactions that degrade chronic performance, and impedes the ability to accurately visualize recording sites within intact circuits. Here we report next-generation silicon-based neural probes at a cellular scale (5 × 10 µm cross section), with ultra-high-density packing (as little as 66 µm between shanks) and 64 or 256 closely spaced recording sites per probe. We show that these probes can be inserted into superficial or deep brain structures and record large spikes in freely behaving rats for many weeks. Finally, we demonstrate a slice-in-place approach for the precise registration of recording sites relative to nearby neurons and anatomical features, including striatal µ-opioid receptor patches. This scalable technology provides a valuable tool for examining information processing within neural circuits and potentially for human brain-machine interfaces.NEW & NOTEWORTHY Devices with many electrodes penetrating into the brain are an important tool for investigating neural information processing, but they are typically large compared with neurons. This results in substantial damage and makes it harder to reconstruct recording locations within brain circuits. This paper presents high-channel-count silicon probes with much smaller features and a method for slicing through probe, brain, and skull all together. This allows probe tips to be directly observed relative to immunohistochemical markers.
Asunto(s)
Encéfalo/fisiología , Electrodos Implantados , Neuronas/fisiología , Neurofisiología/instrumentación , Neurofisiología/métodos , Animales , Masculino , Ratas Long-Evans , SilicioRESUMEN
OBJECTIVE: Neural recording is important for a wide variety of clinical applications. Until recently, recording from the surface of the brain, even when using micro-electrocorticography (µECoG) arrays, was not thought to enable recording from individual neurons. Recent results suggest that when the surface electrode contact size is sufficiently small, it may be possible to record single neurons from the brain's surface. In this study, we use computational techniques to investigate the ability of surface electrodes to record the activity of single neurons. APPROACH: The computational model included the rat head, µECoG electrode, two existing multi-compartmental neuron models, and a novel multi-compartmental neuron model derived from patch clamp experiments in layer 1 of the cortex. MAIN RESULTS: Using these models, we reproduced single neuron recordings from µECoG arrays, and elucidated their possible source. The model resembles the experimental data when spikes originate from layer 1 neurons that are less than 60 µm from the cortical surface. We further used the model to explore the design space for surface electrodes. Although this model does not include biological or thermal noise, the results indicate the electrode contact area should be 100 µm2 or smaller to maintain a detectable waveform amplitude. Furthermore, the model shows the width of lateral insulation could be reduced, which may reduce scar formation, while retaining 95% of signal amplitude. SIGNIFICANCE: Overall, the model suggests single-unit surface recording is limited to neurons in layer 1 and further improvement in electrode design is needed.