Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros












Intervalo de año de publicación
1.
Restor Dent Endod ; 48(1): e4, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36875808

RESUMEN

Objectives: This study aimed to compare the torsional and cyclic fatigue resistance of ProGlider (PG), WaveOne Gold Glider (WGG), and TruNatomy Glider (TNG). Materials and Methods: A total of 15 instruments of each glide path system (n = 15) were used for each test. A custom-made device simulating an angle of 90° and a radius of 5 millimeters was used to assess cyclic fatigue resistance, with calculation of number of cycles to failure. Torsional fatigue resistance was assessed by maximum torque and angle of rotation. Fractured instruments were examined by scanning electron microscopy (SEM). Data were analyzed with Shapiro-Wilk and Kruskal-Wallis tests, and the significance level was set at 5%. Results: The WGG group showed greater cyclic fatigue resistance than the PG and TNG groups (p < 0.05). In the torsional fatigue test, the TNG group showed a higher angle of rotation, followed by the PG and WGG groups (p < 0.05). The TNG group was superior to the PG group in torsional resistance (p < 0.05). SEM analysis revealed ductile morphology, typical of the 2 fracture modes: cyclic fatigue and torsional fatigue. Conclusions: Reciprocating WGG instruments showed greater cyclic fatigue resistance, while TNG instruments were better in torsional fatigue resistance. The significance of these findings lies in the identification of the instruments' clinical applicability to guide the choice of the most appropriate instrument and enable the clinician to provide a more predictable glide path preparation.

2.
Braz Dent J ; 34(1): 12-18, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36888838

RESUMEN

This study aimed to evaluate the influence of temperature on torsional strength and angular deflection of two experimental NiTi rotary instruments manufactured from Blue and Gold thermal treatments and with identical cross-sections. A total of 40 experimental NiTi instruments 25.06 and with a triangular cross-section and manufactured from Blue and Gold thermal treatments were used (n=20). The torsional test was performed in the 3 mm from the tip of the instrument according to ISO 3630-1. The torsional test evaluated the torsional strength and angular deflection to failure at room temperature (21°C ± 1° C) and body temperature (36°C ±1°C). The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). Data were analyzed using an unpaired t test for inter and intra-group comparison and the level of significance was set at 5%. The results showed that the body temperature did not affect the torsional strength and angular deflection of the instruments when compared with room temperature (P>0.05). However, at body temperature, the Blue NiTi instruments presented significantly lower angular deflection in comparison with Gold NiTi instruments (P<0.05). There was no significant difference regarding the torsional strength of the instruments at body temperature (P>0.05). The temperature did not affect the torsional strength of the instruments manufactured from Blue and Gold technology. However, the Blue NiTi instruments presented significantly lower angular deflection than Gold instruments at 36°C temperature.


Asunto(s)
Instrumentos Dentales , Preparación del Conducto Radicular , Estrés Mecánico , Temperatura , Diseño de Equipo , Ensayo de Materiales , Titanio , Oro , Torsión Mecánica
3.
J Endod ; 49(5): 544-548, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36841383

RESUMEN

INTRODUCTION: The obturation quality of the mandibular molar mesial canals and isthmuses with two thermoplastic techniques, ultrasonic vertical condensation (UVC) and continuous wave of condensation (CWC), was evaluated using computed microtomography (µCT). METHODS: Thirty-six human mandibular molars had been previously scanned and analyzed using µCT for mesial roots with morphologically similar isthmuses for this study. Coronal access and confirmation of foraminal patency were performed, and the actual length of the teeth was established using a clinical microscope (40X magnification). The canals were prepared using ProTaper Gold instruments up to #F3, with 2.5% sodium hypochlorite as the irrigant solution, followed by a passive ultrasonic irrigation protocol. The specimens were randomly divided into the UVC and CWC groups based on the obturation technique to be used. Obturation was performed with #F3 gutta-percha cones cemented using AH Plus Jet sealer. The µCT scans were performed after 15 days, and the images were evaluated by a calibrated examiner blinded to the experimental groups to determine the filling rate of the entire canal area, including the main canal and isthmus. Student's t-test was used for statistical analysis; P values ≤0.05 were considered significant. RESULTS: Neither of the thermoplastic obturation techniques achieved complete filling of the canals (86.3% for UVC and 91.4% for CWC), with a statistically significant difference between them (P = .029). CONCLUSIONS: Under the conditions of the study, it can be concluded that none of the techniques completely filled the canal/isthmus of the mandibular molars; however, the CWC exhibited better performance.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Humanos , Cavidad Pulpar/diagnóstico por imagen , Cavidad Pulpar/anatomía & histología , Gutapercha , Diente Molar/diagnóstico por imagen , Diente Molar/anatomía & histología , Materiales de Obturación del Conducto Radicular/uso terapéutico , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular , Ultrasonido , Microtomografía por Rayos X
4.
Braz. dent. j ; 34(1): 12-18, Jan.-Feb. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1420578

RESUMEN

Abstract This study aimed to evaluate the influence of temperature on torsional strength and angular deflection of two experimental NiTi rotary instruments manufactured from Blue and Gold thermal treatments and with identical cross-sections. A total of 40 experimental NiTi instruments 25.06 and with a triangular cross-section and manufactured from Blue and Gold thermal treatments were used (n=20). The torsional test was performed in the 3 mm from the tip of the instrument according to ISO 3630-1. The torsional test evaluated the torsional strength and angular deflection to failure at room temperature (21°C ± 1° C) and body temperature (36°C ±1°C). The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). Data were analyzed using an unpaired t test for inter and intra-group comparison and the level of significance was set at 5%. The results showed that the body temperature did not affect the torsional strength and angular deflection of the instruments when compared with room temperature (P>0.05). However, at body temperature, the Blue NiTi instruments presented significantly lower angular deflection in comparison with Gold NiTi instruments (P<0.05). There was no significant difference regarding the torsional strength of the instruments at body temperature (P>0.05). The temperature did not affect the torsional strength of the instruments manufactured from Blue and Gold technology. However, the Blue NiTi instruments presented significantly lower angular deflection than Gold instruments at 36°C temperature.


Resumo O objetivo deste estudo foi avaliar a influência da temperatura nas propriedades de torção (resistência à torção e deflexão angular) de dois instrumentos rotatórios experimentais de NiTi fabricados com secção triangu.ar e tratamentos térmicos Blue e Gold. Quarenta instrumentos experimentais de NiTi 25.06 com tratamento térmico Blue e Gold foram usados (n= 20). Foi avaliada a resistência torcional e a deflexão angular até a fratura na temperatura ambiente (21°C ± 1°C) e corporal (36°C ± 1°C). O teste torcional foi realizado nos 3 mm da ponta dos instrumentos de acordo com a ISO 3630-1. A superfície fraturada de cada instrumento foi observada pelo microscópio eletrônico de varredura (MEV). Os dados foram analisados por meio do teste t não pareado para a comparação inter e intragrupos e o nível de significância à 5%. Os resultados demonstraram que a temperatura corporal não afetou a resistência a torção e deflexão angular quando comparada com a temperatura ambiente (P>0.05). No entanto, na temperatura de 36°C o instrumento com tratamento térmico Blue apresentou menor deflexão angular quando comparado com o Gold (P<0.05). Não houve diferença significante entre os dois instrumentos em relação a resistência à torção. A temperatura corporal não modificou a resistência torcional dos instrumentos fabricados com tecnologia Blue e Gold. No entanto, os instrumentos com NiTi Blue apresentaram menor deflexão angular do que o Gold a 36°C.

5.
Eur Endod J ; 7(3): 217-222, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36217638

RESUMEN

OBJECTIVE: To evaluate the solubility, pH, antimicrobial action, and cytotoxicity of ambroxol hydrochloride (AMB), N-acetylcysteine (NAC), and calcium hydroxide (CH) pastes for use as intracanal medications. METHODS: Solubility was determined by micro-CT, based on the paste volume remaining after immersion in water for 7 days. pH was measured by immersing acrylic tubes containing the pastes in ultrapure water and then measuring pH after 3 hours, 3 days, and 7 days. Antimicrobial action against Enterococcus faecalis was assessed based on the percentage of living cells, using the live/dead staining method under confocal microscopy. Cytotoxicity was assessed based on the cell viability of L929 fibroblast-like cells after 6, 24, and 48 hours. Cytotoxicity data were compared using the ANOVA and Tukey tests, and the antimicrobial data were compared using the Kruskal-Wallis and Dunn tests. The significance level used was 5% (α=0.05). RESULTS: The solubility values for all the study groups were significantly different (P<0.05), where the highest values were for NAC, followed by AMB, and then CH. Likewise, the pH levels were all significantly different (P<0.05), where NAC and AMB levels were acidic, and CH levels were alkaline. The antimicrobial action of AMB was significantly higher than that of CH (P<0.05), and that of NAC was also higher than that of CH, albeit not significantly. AMB and NAC were more cytotoxic than CH, and higher dilutions of CH promoted higher cell viability levels than lower dilutions of the same paste (P<0.05). CONCLUSION: The NAC and AMB pastes were more soluble and cytotoxic than the CH paste and had acidic pH levels. The AMB paste displayed the highest antimicrobial action against Enterococcus faecalis biofilm.


Asunto(s)
Ambroxol , Antiinfecciosos , Acetilcisteína/farmacología , Ambroxol/farmacología , Antiinfecciosos/farmacología , Hidróxido de Calcio/toxicidad , Fenómenos Químicos , Enterococcus faecalis , Agua
6.
J. res. dent ; 10(2): 1-6, apr.-jun2022.
Artículo en Inglés | LILACS, BBO | ID: biblio-1395871

RESUMEN

Background: The aim of this study was to evaluate the cyclic fatigue and torsional fatigue resistance of three thermally treated rotary instruments, such as: Logic 2 25.05 (LOG 25.05), Edge Taper Platinum 25.06 (EDT 25.06) and ProTaper Gold 25.08 (PTG 25.08).Methods: A total of 60 rotary instruments of LOG 25.05, EDT 25.06 and PTG 25.08 were used (n=20). Cyclic fatigue tests were performed at 36°C using an artificial stainless steel canal with a 60ºangle and a 5-mm radius of curvature. The time (in seconds) and number of cycles to fracture (NCF) was recorded. The torsional test evaluated the torque and angle of rotation to failure at 3 mm from the tip according to ISO 3630-1. The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). Data were analyzed using one-way ANOVA and Holm-Sidak's tests for multiple comparison, the level of significance was set at 5%.Results: EDT 25.06 had highest cyclic fatigue resistance (time and NFC), followed by LOG 25.05 and PTG 25.08 (P<0.05). There were no significantly difference between LOG 25.05 and ETP 25.06 regarding the NCF (P>0.05). In relation the torsional test, the LOG 25.05 and ETP 25.06 presented similar torque (P>0.05). The PTG presented greater torque than the other groups (P<0.05). The PTG 25.08 presented the lowest angular rotation to fracture than the other groups (P<0.05). The SEM images demonstrated typical features of cyclic and torsional fracture.Conclusion: In conclusion, the LOG 25.05 and ETP 25.06 presented similar cyclic and torsional properties. The PTG 25.08 showed greater torsional strength.


Asunto(s)
Humanos , Endodoncia
7.
Int Endod J ; 55(1): 103-112, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34561894

RESUMEN

AIM: To evaluate the influence of the design of endodontic access cavities on the percentage of unprepared areas of canal walls and flexural fatigue of instruments activated by reciprocating movement in oval-shaped straight root canals of extracted teeth. METHODOLOGY: Forty-two mandibular incisors with oval canals were scanned by a microcomputed tomography (micro-CT) device for homogeneous selection and distribution of the samples. Then, the teeth were divided into two groups (n = 21) according to the design of access cavity being tested: ultraconservative endodontic access cavity (UltraAC) and traditional access cavity. The canals were accessed with the aid of a surgical microscope, instrumented with the WaveOne Gold Medium system and irrigated with 2.5% NaOCl and 17% EDTA. The unprepared areas of the canal wall were analysed by overlaying images before and after instrumentation and expressed as percentages. micro-CT data were analysed using t-test, Mann-Whitney and Wilcoxon tests. The endodontic instruments used during instrumentation were subjected to static flexural fatigue testing using an artificial stainless steel canal with a 60° angle of curvature and a radius of 5 mm, located 5 mm from the tip of the instrument. The instruments were activated until fracture occurred, and the time in seconds for the fracture was recorded using a digital timer. The number of cycles to fracture was calculated and analysed statistically. For flexural fatigue data, an anova test complemented by a Tukey range test was used. The significance level of 5% was used for all analyses. RESULTS: There was no significant difference between the groups related to unprepared areas by the instrument during canal preparation (p > .05). The difference in flexural fatigue resistance between the groups was not significant. CONCLUSION: The use of UltraAC did not interfere with the canal instrumentation of extracted mandibular incisors with straight and oval canals. There was no difference in the flexural fatigue resistance of the instruments in relation to access cavity design.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Cavidad Pulpar/diagnóstico por imagen , Incisivo/diagnóstico por imagen , Acero Inoxidable , Microtomografía por Rayos X
8.
Eur Endod J ; 6(3): 284-289, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34967334

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the bending and torsional resistance of the following instruments: Mtwo 25/.07 (MT - VDW, Munich, Germany), Navigator W-XN 25.07 (WXN - Wizard Navigator, Medin, Nové Mesto na Morave, Czech Republic), ProTaper Universal SX 19/.04 (PSX - Dentsply Tulsa Dental Specialties, Tulsa, USA), MK Orifice Shapper 17/.08 (OS - MK Life Medical and Dental Products, Porto Alegre, Brazil) and MK Sequence 17.12 (MKS - MK Life Medical and Dental Products, Porto Alegre, Brazil). METHODS: One hundred instruments were used (n=20). Resistance to bending (n=10), torque and angular deflection (n=10) at the failure of new instruments were measured according to ISO 3630-1. Metal mass volume at 3 mm from the tip was evaluated using micro-computed tomography (micro-CT). The fractured surface of each fragment was examined by scanning electron microscopy (SEM). Data were analysed using 1-way analysis of variance and Tukey tests. RESULTS: Torsional resistance values of MK Sequence were higher than the other groups (P<0.05). No differences were observed among MT, WXN and OS (P>0.05) and PTS, which presented the lowest values (P<0.05). MT showed the highest angular deflection (P<0.05). WXN and PSX presented no significant difference (P>0.05). PSX and OS also showed no significant differences (P>0.05). MKS instruments had the lowest angular deflection values (P<0.05). There were significant differences among all the groups in bending stiffness test (P<0.05), but PSX had the lowest torque to bend (P<0.05). MKS had the larger metal mass volume at 3 mm from the tip (P<0.05). SEM analysis showed similar and typical features of torsional failure for all instruments tested. CONCLUSION: In conclusion, MK Sequence 17/.12 had the highest torsional fracture resistance. Mtwo 25/.07 showed higher angular deflection capacity, and ProTaper Universal SX the 19/.04 lower bending stiffness.


Asunto(s)
Níquel , Titanio , Aleaciones Dentales , Preparación del Conducto Radicular , Torsión Mecánica , Microtomografía por Rayos X
9.
Braz Oral Res ; 35: e064, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34076189

RESUMEN

Sixty moderately curved canals of mandibular molars classified as Vertucci's type IV canal configuration were selected by micro-CT 1174. The teeth were divided into two groups according to the kinematics used, whether reciprocating or rotary motion (n=30, totaling 60 mesial root canals). The instruments used to perform the glide path procedures had identical features (0.15 mm of tip size, 0.04 mm/mm taper, thermal treatment, and square cross-section), but differed in the direction of the cutting blade. The duration of the procedure and the absolute and percentage frequency of the instruments to reach the full working length were recorded. The torsional test (3630-1; 1992) was performed on both used and unused instruments, to evaluate a possible reduction in the torsional resistance when using the glide path procedure. Statistical analysis was performed using the unpaired t-test and the chi-square test, and the level of significance was set at 5%. The type of kinematics used affected the duration of glide path procedures, and the reciprocating motion seemed to induce less torsional stress during glide path procedures.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Fenómenos Biomecánicos , Diseño de Equipo , Diente Molar/diagnóstico por imagen , Microtomografía por Rayos X
10.
Aust Endod J ; 47(3): 544-549, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33913601

RESUMEN

This study evaluated the resistance to flexural fatigue and torsional strength of files for glide path preparation in continuous rotation or Optimum Glide Path motion (OGP). ScoutRace 15.02 and ProGlider 16.02 files were used in a dynamic testing device during preparation of simulating curved root canals (40-degree curvature and 5 mm radius). For the torsional test, a machine was used to test torsion measured maximum torsional strength (N.cm). Two-way anova and Tukey's multiple comparisons test were used for statistical analysis. Files in OGP motion had a statistically better resistance to flexural fatigue (P < 0.05). ProGlider files took longer time to failure than ScoutRace files only when OGP was used (P < 0.05). The torsional test revealed that OGP produced significantly less torsional stress than rotary motions for both types of glide path files (P < 0.05) In conclusion, OGP motion increased substantially the mechanical safety of endodontic glide path files.


Asunto(s)
Deportes , Proyectos de Investigación
11.
Aust Endod J ; 47(2): 265-272, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33296137

RESUMEN

This study investigated the cyclic fatigue, bending, torsional resistance and angular deflection of Pro-R 25.08, Logic RT 25.08, MK Retreatment 25.08 (MK RT) and ProTaper Retreatment D2 instruments. Cyclic fatigue test was performed until fracture in a custom stainless-steel device with water bath equipment to simulate body temperature. Fracture time was recorded. A number of cycles were calculated. Resistance to bending at 45°, torsional resistance and angular deflection were evaluated. The fracture surfaces were examined by scanning electron microscopy. Statistical analysis was performed with one-way ANOVA and Tukey and Kruskal-Wallis and Dunn tests. Pro-R and Logic RT presented the highest cyclic fatigue (P < 0.05). D2 had higher strength to bend than Pro-R and Logic RT (P < 0.05). Logic RT showed the highest torque and angular deflection (P < 0.05), without differences when compared to D2 (P > 0.05). Instrument performances were dependent on their geometrical features and heat treatments.


Asunto(s)
Níquel , Titanio , Aleaciones Dentales , Diseño de Equipo , Falla de Equipo , Ensayo de Materiales , Retratamiento , Preparación del Conducto Radicular , Estrés Mecánico , Torsión Mecánica
12.
Rev. Salusvita (Online) ; 40(3): 166-172, 2021.
Artículo en Portugués | LILACS | ID: biblio-1412375

RESUMEN

O objetivo do presenteestudo foi avaliar a atividade antibacteriana dos cimentos endodôn-ticos MTA Fillapex, Sealapex, Sealer 26 e Endofill puros e acrescidos de amoxicilina e ci-profloxacina frente a duas linhagens ATCC de Enterococcus faecalis (ATCC 29212 e ATCC 4083). Os testes foram realizados pela técnica de difusão radial dos cimentos aplicados di-retamente no ágar e impregnados em discos de papel e pelo teste de contato direto. Para a análise estatística, utilizaram-se os testes de ANOVA e Tukey com nível de significância de 5%. Os resultados mostraram que pela técnica da difusão radial, considerando os cimentos puros, o Sealapex foi o único que apresentou halos de inibição frente às duas linhagens. Já quando da associação de amoxicilina e ciprofloxacina, o MTA Fillapex revelou os melhores halos de inibição para as duas linhagens. Todos os cimentos tiveram a ação potencializada pela adição dos antibióticos (p<0,05). Pela técnica de difusão dos cimentos impregnados em discos de papel, o cimento Sealapex puro fresco demonstrou atividade antimicrobiana em todas as variáveis de tempo. Quando acrescidos dos antibióticos, todos os cimentos ti-veram a ação antimicrobiana potencializada pelas drogas, em todas as variáveis de tempo. Esse mesmo resultado foi observado na técnica do contato direto dos cimentos com ambas as linhagens. A atividade antibacteriana, frente ao E. faecalis, dos cimentos MTA Fillapex, Endofill, Sealer e Sealapex, acrescidos dos antibióticos amoxicilina e ciprofloxacina, foi potencializada mesmo após um longo período da presa dos cimentos.


The objective of this study was to evaluate the antibacterial activity of different endodon-tic cements (MTA Fillapex, Sealapex, Sealer 26, and Endofill), both pure and mixed with 5% of amoxicillin or ciprofloxacin, against two strains of Enterococcus faecalis (ATCC 29212 and ATCC 4083). Bacterial susceptibility testing was conducted by radial diffusion methods and direct contact test after different periods. Data were subjected to ANO-VA and Tukey test with a significance level of 5%. Sealapex was the only pure sealer to promote the inhibition of bacterial growth against both strains in different experimental periods. However, all cements present an increase in antibacterial activity by the addition of antibiotics (p<0.05). MTA Fillapex and Sealapex associated with amoxicillin promoted increased values for bacterial growth against ATCC 29212 and ATCC 4083 in comparison to other groups (p<0.001), including extended periods after setting time. The association of antibiotic agents increased the antibacterial effect of the evaluated sealers against the strains of E. faecalis.


Asunto(s)
Endodoncia/instrumentación , Enterococcus faecalis
13.
Microsc Res Tech ; 82(5): 494-500, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30597714

RESUMEN

Enterococcus faecalis and Candida albicans have been associated with cases of secondary and persistent root canal infections, been resistant to calcium hydroxide. So, the evaluation of the susceptibility of these microorganisms biofilms to new drugs is an important practice for establishing the best drug and consequently success of treatment. For this, in vitro biofilm formation of E. faecalis and C. albicans was induced separately on blocks obtained from bovine teeth. After the period of specimen incubation for biofilm maturation, the samples were immersed in the pastes: 1 - calcium hydroxide (CH), 2 - chlorhexidine (C), 3 - ciprofloxacin (CP), 4 - metronidazole (MT), 5 - ketoconazole (KE), 6 - double antibiotic (DB), 7 - triple antibiotic (TA), 8 - ciprofloxacin + ketoconazole (CPKE); 9 - ciprofloxacin + metronidazole + ketoconazole (CPMTKE), 10 - metronidazole + ketoconazole (MTKE), and 11 - control (CO) for 7 days. Next, the specimens were live/dead stained for analysis by confocal microscopy. By means of the Bioimage program, the biovolume and percentage of live cells were measured. The data were statistically compared (p = .05). For the C. albicans biofilm, the best antimicrobial action was found for MTKE, CPKE, and MT groups. Whereas for E. faecalis biofilm, the lowest percentage of live bacteria was found in TA, DB, and CP groups; however, KE, CPKE, CPMTKE, and MTKE groups shown to be effective. The authors concluded calcium hydroxide paste and chlorhexidine was not effective for both biofilms. The MTKE and CPKE pastes presented effectiveness for both biofilms. TA and DB pastes were effective just in the E. faecalis biofilms.


Asunto(s)
Antiinfecciosos/farmacología , Biopelículas/efectos de los fármacos , Candidiasis/tratamiento farmacológico , Infecciones por Bacterias Grampositivas/tratamiento farmacológico , Tratamiento del Conducto Radicular/métodos , Enfermedades Estomatognáticas/tratamiento farmacológico , Animales , Candida albicans/efectos de los fármacos , Bovinos , Enterococcus faecalis/efectos de los fármacos , Procesamiento de Imagen Asistido por Computador , Incisivo , Microscopía Confocal , Modelos Teóricos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...