Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Ultrasound Med Biol ; 42(8): 1834-47, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27181686

RESUMEN

Noninvasive recordings of electrophysiological activity have limited anatomic specificity and depth. We hypothesized that spatially tagging a small volume of brain with a unique electroencephalography (EEG) signal induced by pulsed focused ultrasound could overcome those limitations. As a first step toward testing this hypothesis, we applied transcranial ultrasound (2 MHz, 200-ms pulses applied at 1050 Hz for 1 s at a spatial peak temporal average intensity of 1.4 W/cm(2)) to the brains of anesthetized rats while simultaneously recording EEG signals. We observed a significant 1050-Hz electrophysiological signal only when ultrasound was applied to a living brain. Moreover, amplitude demodulation of the EEG signal at 1050 Hz yielded measurement of gamma band (>30 Hz) brain activity consistent with direct measurements of that activity. These results represent preliminary support for use of pulsed focused ultrasound as a spatial tagging mechanism for non-invasive EEG-based mapping of deep brain activity with high spatial resolution.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/fisiopatología , Electroencefalografía/métodos , Ultrasonografía/métodos , Animales , Modelos Animales , Fantasmas de Imagen , Ratas , Sensibilidad y Especificidad
2.
PLoS One ; 9(2): e86939, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24504255

RESUMEN

Transcranial ultrasound can alter brain function transiently and nondestructively, offering a new tool to study brain function now and inform future therapies. Previous research on neuromodulation implemented pulsed low-frequency (250-700 kHz) ultrasound with spatial peak temporal average intensities (ISPTA) of 0.1-10 W/cm(2). That work used transducers that either insonified relatively large volumes of mouse brain (several mL) with relatively low-frequency ultrasound and produced bilateral motor responses, or relatively small volumes of brain (on the order of 0.06 mL) with relatively high-frequency ultrasound that produced unilateral motor responses. This study seeks to increase anatomical specificity to neuromodulation with modulated focused ultrasound (mFU). Here, 'modulated' means modifying a focused 2-MHz carrier signal dynamically with a 500-kHz signal as in vibro-acoustography, thereby creating a low-frequency but small volume (approximately 0.015 mL) source of neuromodulation. Application of transcranial mFU to lightly anesthetized mice produced various motor movements with high spatial selectivity (on the order of 1 mm) that scaled with the temporal average ultrasound intensity. Alone, mFU and focused ultrasound (FUS) each induced motor activity, including unilateral motions, though anatomical location and type of motion varied. Future work should include larger animal models to determine the relative efficacy of mFU versus FUS. Other studies should determine the biophysical processes through which they act. Also of interest is exploration of the potential research and clinical applications for targeted, transcranial neuromodulation created by modulated focused ultrasound, especially mFU's ability to produce compact sources of ultrasound at the very low frequencies (10-100s of Hertz) that are commensurate with the natural frequencies of the brain.


Asunto(s)
Encéfalo/anatomía & histología , Encéfalo/fisiología , Ultrasonido/métodos , Animales , Masculino , Ratones Endogámicos C57BL , Actividad Motora/fisiología , Presión , Ultrasonido/instrumentación