Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
J Endod ; 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39094780

RESUMEN

AIM: To assess the effect of combinations of two different endodontic sealers used in initial and endodontic retreatment on the bond strength of the secondary obturation and the penetrability of the sealers. METHODS: Forty-eight mandibular premolars were used, receiving standardized endodontic access and biomechanical preparation. Twenty-four teeth received AH Plus sealer (AHP) in primary obturation, and the others received Bio-C® Sealer (BCS) sealer. Retreatment protocol was performed with an R50 instrument. The samples were further subdivided into four groups (n=12) based on the combination of primary/secondary obturation sealers: AHP/AHP; AHP/BCS; BCS/AHP; BCS/BCS. Four samples from each subgroup received the addition of fluorophores to the sealer for penetrability analysis using laser scanning confocal fluorescence microscopy (LSCFM). The root portion on the 8 push-out samples was sectioned into 6 slices of 1.0 mm. Bond strength (BS) was assessed using a universal testing machine until displacement of the filling mass. Failure pattern was evaluated under a stereomicroscope (20x magnification). BS data were analyzed using two-way ANOVA followed by Tukey's test (p<0.05), and the association between the failure pattern and BS value was assessed using the chi-square test (p<0.05). Penetrability was qualitatively evaluated. RESULTS: The highest BS values were observed in the AHP/AHP (4.54±1.5 MPa) and BCS/AHP (5.00±1.0 MPa) groups (p<0.05), with a higher percentage of adhesive failures to the filling material for all groups. LSCFM images indicated greater penetrability of AHP compared to BCS, both in initial treatment and retreatment. CONCLUSION: AHP sealer exhibited higher BS and greater penetrability compared to BCS sealer.

2.
J Endod ; 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39038534

RESUMEN

AIM: To evaluate the volume of dentin removal and volume of remnants of restorative material after removal of aesthetical restorative coronal set and cervical barrier in endodontically treated mandibular molars with aid of different magnification methods, using 3D MicroCT morphometric analysis. METHODS: A sample of 30 mandibular first molars (n=30) were used. All teeth were endodontic treated, and the specimens were initially scanned in MicroCT and reconstructed. The molars were filled by single cone technique, and immediately the material at the initial 2 mm cervical level were removed. Cervical barriers were confected using ionomer glass cement added with fluorescein 0.1%, filling the 2 mm at the cervical level of the canals and 2 additional millimeters as base. Coronal restoration set was performed using aesthetical resin composites. Simulated tooth aging process was performed with 20,000 thermocycling cycles. The sample was distributed in three groups (n=10) for the removal of the restoration set and cervical barrier with diamond burs based on the magnification aid: No magnification aid (naked-eye); Operative microscope aid; REVEAL™ device aid. After removal, final 3D MicroCT scanning and reconstruction were conducted with same parameters as the initial, and superposition of final and initial scanning was done. Morphometric analysis was conducted using CTAn to assess volume of remnant restorative material (mm³), volume of dentin removal (mm³), and the direction and site of dentin removal. Data were analyzed using One-Way ANOVA (p<0.05). RESULTS: REVEAL™ group showed better results regarding the volume of remnant material (3.17 ± 1.65) and the percentage of dentin removal (2.56 ± 1.34). Microscope group showed no statistical difference to the REVEAL™ group of dentin removal (3.30 ± 1.48), and was statistically similar to the naked eye group in volume of remnant material (9.63 ± 4.33). Naked eye group showed the worst results for volume of remnant material (7.60 ± 2.68) and percentage of dentin removal (6.60 ± 3.70). CONCLUSION: The use of fluorescence associated with magnification was the method that presented the best results, with lower percentages of dentin removal and smaller volumes of remaining restorative material. This is an innovative technology in Endodontics that shows potential to overdue the challenge of re-accessing root canals in the context of endodontic retreatment.

3.
Odontology ; 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38514512

RESUMEN

To evaluate the impact on the quality of filling with of low-fusion and conventional gutta-percha cones. Thirty-six maxillary canines were prepared and divided into three groups: I-conventional cone with Downpack at 200 °C at 4 mm from the WL; II-low-fusion cone with Downpack at 100 °C up to 4 mm from the WL; III-low-fusion cone with Downpack at 100 °C up to 7 mm from the WL. Temperature variations were measured in thirds on the external surface of the root. The bond strength was evaluated using the push-out test. The adhesive interface was analyzed by scanning electron microscopy. The bond strength and the temperature variation data were analyzed using analysis of variance and the failure type using the chi-square test. The low-fusion cone group with 7 mm Downpack showed higher bond strength (4.2 ± 2.7) compared with conventional cones (2.8 ± 1.6) and low-fusion cones with 4 mm Downpack (2.9 ± 1.6) (p < 0.05), with occurrence of a higher number of adhesive failures to the filling material and mixed failures. Relative to temperature variation, there was less temperature change in the apical third, in the low-fusion cone with Downpack 7 mm (1.0 ± 1.0) (p < 0.05). The use of low-fusion cones allowed the continuous wave condensation technique to be performed at a lower depth of Downpack at 100 °C at 7 mm, with less heating in the apical third, without compromising the quality of filling. Using gutta-percha cones with low fusion, which permits a lower condensation temperature and reduced Downpack depth, maintains the quality of filling, in order to minimize possible damage to the periapical tissues.

4.
J Mech Behav Biomed Mater ; 151: 106400, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38262184

RESUMEN

AIM: To mensure the physicochemical properties of three ceramic cement endodontic sealers AH Plus Bioceramic, Bio-C Sealer and Bio-C Sealer Ion+ with an epoxy resin sealer, AH Plus. MATERIAL AND METHODS: These properties were measured: hardening time (HT), dimensional change (DC), solubility (SL), flow (FL) and radiopacity (RD). The distilled water obtained from the SL test was analyzed with atomic absorption spectrometry. A sample calculation was made considering n = 5 repetitions for each experimental sealer evaluated. Statistical analysis was performed using one-way ANOVA and post hoc Tukey tests (p < 0.05). RESULTS: For the HT, AH Plus (484 ± 2.76 min) and AH Plus Bioceramic (424 ± 1.23 min) set more slowly than of Bio-C Sealer (370 ± 4.50 min) and Bio-C Sealer Ion+ (380 ± 1.42 min) (p < 0.05). AH Plus Bioceramic (12.56 ± 2.71 %) was more soluble than Bio-C Sealer (6.69 ± 1.67 %), Bio-C Sealer Ion+ (5.67 ± 2.16 %) and AH Plus (0.15 ± 0.01 %) (p < 0.05). AH Plus (0.03 ± 0.01 %) had slight expansion while the cement-based sealers had shrinkage: AH Plus Bioceramic (-1.60 ± 0.63 %) and Bio-C Sealer (-1.38 ± 0.69 %), Bio-C Sealer Ion+ (-5.19 ± 1.23 %) (p < 0.05). Bio-C Sealer Ion+ (59.80 ± 0.86 mm) and Bio-C Sealer (58.60 ± 0.98 mm) had the highest flow compared with AH Plus (56.90 ± 0.56 mm) and AH Plus Bioceramic (49.50 ± 0.63 mm) (p < 0.05). AH Plus (9.17 ± 0.06 mmAl) and AH Plus Bioceramic (8.27 ± 0.84 mmAl) showed radiopacity values when compared with those of Bio-C Sealer (4.90 ± 0.08 mmAl) and Bio-C Sealer Ion+ (4.14 ± 0.05 mmAl) (p > 0.05). CONCLUSION: Ion release is inhered to these cement-based sealers and this result in calcium ion release.


Asunto(s)
Calcio , Materiales de Obturación del Conducto Radicular , Calcio/química , Materiales de Obturación del Conducto Radicular/química , Compuestos de Calcio/química , Resinas Epoxi/química , Silicatos/química , Ensayo de Materiales
5.
Braz Oral Res ; 37: e096, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38055514

RESUMEN

The survival of endodontically treated teeth depends on the remaining tooth structure. The aim of this study was to evaluate the impact of different access cavities on root canal preparation, restorative protocol, and fracture resistance of endodontically treated teeth. Fifty-six mandibular molars were divided into control (n=8) and experimental (n=16) groups according to access cavity: Traditional, Conservative, and Truss; and redistributed (n=8) according to instrumentation protocols: Reciproc Blue and R-motion. After, teeth were scanned in micro-CT and then filled and redistributed according to composite resin restoration (n=8): Filtek One BulkFill and Filtek Z350. A new micro-CT scan was performed to analyze the restorative material. Then, samples were submitted to fracture resistance testing and the failure pattern was determined. Data were analyzed using paired T-test, ANOVA, Tukey, and chi-square tests (α=0.05). In Truss, R-Motion promoted less transportation in different thirds of root canals. Higher percentages of voids (5.05%) and filling material (11.7%) were observed in Truss. Fracture resistance values were higher for the control group, followed by Truss, Conservative, and Traditional. The predominant failure pattern was type-II. In Truss, reciprocating instruments with smaller taper showed less canal transportation. Also, Truss provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material. Thus, in Truss, reciprocating files with smaller taper showed less canal transportation, and these cavities provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material.


Asunto(s)
Caries Dental , Materiales de Obturación del Conducto Radicular , Diente no Vital , Humanos , Preparación del Conducto Radicular/métodos , Diente Molar , Microtomografía por Rayos X , Cavidad Pulpar
6.
Clin Oral Investig ; 27(12): 7919-7933, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38032392

RESUMEN

AIM: To evaluate the bond strength (BS) and analysis of the adhesive interface in root canals filled with bioceramic gutta percha sealers and cones. MATERIAL AND METHODS: Ninety-six maxillary canines were divided into eight groups according to the endodontic sealer (AH Plus, AH Plus Bioceramic, Bio-C Sealer or Bio-C Sealer Ion+ and gutta percha cones (conventional or bioceramic) tested. They were analyzed using the BS test, failure pattern, analysis of the adhesive interface by scanning electron microscopy and confocal laser scanning microscopy. The BS data were compared between groups using the analysis of variance test with the Turkey post-test. The chi-square test was used to assess the type of failure and the non-parametric Mann-Whitney and Kruse-Wallis tests (P < 0.05). RESULTS: Analysis of variance showed higher BS values for the groups of bioceramic gutta percha cones in Bio-C Sealer Ion+ (8.38 ± 4.27), AH Plus Bioceramic (6.19 ± 3.28), Bio-C Sealer (5.70 ± 3.18), AH Plus (4.61 ± 2.11) and for conventional gutta percha cones in AH Plus sealers (4.26 ± 2.35), Bio-C Sealer Ion + (3.63 ± 2.29), Bio-C Sealer (2.94 ± 2.32) and AH Plus Bioceramic (1.19 ± 0.89) (P < 0.05). Relative to the type of failure and adaptation of the types of filling material, a higher percentage of mixed failures was observed (gaps between 1 µm-10 µm) for the group with bioceramic gutta percha cones (P < 0.001). CONCLUSION: The bond between sealers and bioceramic gutta percha cones showed higher bond strength values and greater penetration into the dentin tubules. CLINICAL RELEVANCE: The filling the root canal system with bioceramic sealers should be associated with bioceramic gutta percha cones.


Asunto(s)
Gutapercha , Materiales de Obturación del Conducto Radicular , Gutapercha/química , Materiales de Obturación del Conducto Radicular/química , Resinas Epoxi/química , Cavidad Pulpar , Cementos Dentales , Obturación del Conducto Radicular , Ensayo de Materiales
7.
Animals (Basel) ; 13(16)2023 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-37627438

RESUMEN

Predicting species' ecological responses to landcovers within landscapes could guide conservation practices. Current modelling efforts derived from classic species-area relationships almost always predict richness monotonically increasing as the proportion of landcovers increases. Yet evidence to explain hump-shaped richness-landcover patterns is lacking. We tested predictions related to hypothesised drivers of peaked relationships between richness and proportion of natural landcover. We estimated richness from breeding bird atlases at different spatial scales (25 to 900 km2) in New York State and Southern Ontario. We modelled richness to gradients of natural landcover, temperature, and landcover heterogeneity. We controlled models for sampling effort and regional size of the species pool. Species richness peaks as a function of the proportion of natural landcover consistently across spatial scales and geographic regions sharing similar biogeographic characteristics. Temperature plays a role, but peaked relationships are not entirely due to climate-landcover collinearities. Heterogeneity weakly explains richness variance in the models. Increased amounts of natural landcover promote species richness to a limit in landscapes with relatively little (<30%) natural cover. Higher amounts of natural cover and a certain amount of human-modified landcovers can provide habitats for species that prefer open habitats. Much of the variation in richness among landscapes must be related to variables other than natural versus human-dominated landcovers.

8.
Artículo en Inglés | MEDLINE | ID: mdl-37580223

RESUMEN

OBJECTIVE: The objective of this study was to evaluate 2-dimensional (2D) and 3D morphometric parameters of C-shaped root canals on cone beam computed tomography (CBCT) and microcomputed tomography (microCT) images using nanocomputed tomography (nanoCT) as the reference standard. STUDY DESIGN: Sixty mandibular molars with C-shaped canals were individually scanned using nanoCT and microCT. Cone beam computed tomography acquisitions were then performed with 4 CBCT systems, using high and standard resolutions. The 2D parameters of roundness and major and minor diameters were obtained in the cross sections of the root canals at 1, 2, and 3 mm from the root apex. The 3D parameters of surface area, volume, and structure model index were measured considering the entire extension of the root canals. Absolute error (AE) in measurement was calculated against the nanoCT values. Data were statistically analyzed with the Shapiro-Wilk test and analysis of variance (α = 0.05). RESULTS: No significant differences in AE were discovered for the 2D parameters among microCT and the CBCT scans. The AE values for the 3D parameters of volume and surface area were significantly smaller in microCT compared to all CBCT units (P < .05). Significantly lower AE values for surface area were observed in high resolution compared to standard resolution for all CBCT units (P < .05). Structure model index did not differ significantly among microCT and all CBCT protocols. CONCLUSIONS: Cone beam computed tomography images showed accuracy for evaluating 2D parameters and over- and underestimation for 3D parameters.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Cavidad Pulpar , Humanos , Cavidad Pulpar/diagnóstico por imagen , Microtomografía por Rayos X , Tomografía Computarizada de Haz Cónico/métodos , Diente Molar/diagnóstico por imagen , Raíz del Diente , Mandíbula/diagnóstico por imagen
9.
J Endod ; 49(9): 1154-1160, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37516237

RESUMEN

INTRODUCTION: The aim of this study was to evaluate the influence on bond strength and interface quality of different canal drying protocols in roots filled with Bio-C Sealer (BCS; Angelus, Londrina, Paraná, Brazil). METHODS: Ninety-six roots of upper canines were prepared with an R50 file (Reciproc; VDW GmbH, Munich, Germany) and irrigated with 2.5% sodium hypochlorite and 17% EDTA under ultrasonic agitation. Roots were divided according to the drying protocol as follows: dry, the White Mac tip (Ultradent, Indaiatuba, SP, Brazil) for 5 seconds followed by aspiration with a capillary tip for 5 seconds and paper points; slightly moist, the White Mac tip followed by capillary aspiration without paper points; wet, the White Mac tip followed by a single paper point. The roots were filled with BCS or AH Plus (AHP; Dentsply Maillefer, Ballaigues, Switzerland) (n = 16) and sectioned for the push-out test after 3 months. Failure modes were assessed, and the interface morphology was analyzed under scanning electron microscopy. After 6 months, the other half of the roots were evaluated. Data were analyzed by analysis of variance/Tukey test at 5%. The chi-square test was used in the failure analysis and the Kruskal-Wallis/Dwass-Steel-Critchlow-Fligner for interface analysis. RESULTS: The AHP-filled roots had the highest bond strength when the canal was dried (P < .05). No difference was found for periods (P > .05). For BCS, the highest bond strength was found in the slightly moist canals (P < .05). A predominance of adhesive failures was observed. The dried canals filled with AHP had the highest percentage of good adaptation, whereas BCS had no difference. CONCLUSIONS: The best drying protocol for AHP is using the White Mac tip followed by capillary tip aspiration and paper points until complete dryness, and for BCS, it is using the White Mac tip followed by capillary aspiration without paper points.


Asunto(s)
Recubrimiento Dental Adhesivo , Materiales de Obturación del Conducto Radicular , Materiales de Obturación del Conducto Radicular/química , Resinas Epoxi/química , Recubrimiento Dental Adhesivo/métodos , Dentina , Preparación del Conducto Radicular/métodos , Cementos Dentales
10.
Braz Oral Res ; 37: e056, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37255076

RESUMEN

To investigate the influence of the remaining volume of a new intracanal medication based on bioceramic compounds on the bond strength (BS) and formation of an adhesive interface between calcium silicate-based and epoxy resin-based root canal sealers. For this purpose, the specimens were distributed according to the intracanal medication (n = 26): Bio-C Temp (BCT) and Ultracal XS (UXS). The roots were scanned in microCT, and after 7 days, the medication was removed. Then a new scan was performed to evaluate the volume of medication remaining. Subsequently, 40 specimens were redistributed into 2 subgroups (n = 10) and filled according to the sealer used: AH Plus (AHP) and Bio-C Sealer (BCS), to assess the bond strength by using the push-out test, and the adhesive interface by confocal laser fluorescence microscopy (CLSM) and scanning electron microscopy (SEM). The t test showed a smaller remainder of BCT (1.77 ± 0.86) compared with UXS (10.47 ± 5.78), irrespective of the root third evaluated. The BS showed that teeth with BCT + BCS had higher bond strength values (3.70 ± 1.22) when compared to the other groups: BCT + AHP (2.15 ± 1.07), UXS + BCS (3.18 ± 1.09) and UXS + AHP (2.11 ± 1.02) (p<0.001). The cervical third had higher BS when compared with the middle and apical thirds (p < 0.001), and higher number of adhesive failures. The adhesive interface in SEM and CLSM images showed better adaptation for the association between BCT + BCS. Intracanal medication and silicate-based endodontic sealer appeared to interact chemically by forming a biomineralizing layer, allowing for an increase in the bond strength and forming an adhesive interface between the materials, with no or less gap formation.


Asunto(s)
Recubrimiento Dental Adhesivo , Materiales de Obturación del Conducto Radicular , Materiales de Obturación del Conducto Radicular/química , Cavidad Pulpar , Dentina , Resinas Epoxi/química , Recubrimiento Dental Adhesivo/métodos , Ensayo de Materiales
11.
Aust Endod J ; 49(1): 130-139, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35649116

RESUMEN

Shaping ability evaluation of taper ./01 instruments in large root canals, by microcomputed tomography (micro-CT) and scanning electron microscopy (SEM). Maxillary central incisors with large diameter root canals were divided into two groups (n = 10): XP-Endo Shaper (FKG-Dentaire, Switzerland) and manual instrumentation (FKG-Dentaire). Two- and three-dimensional parameters from cervical to apical root thirds were evaluated by micro-CT. Apical stop was evaluated by SEM images. Data were analysed by ANOVA and Tukey tests (α = 5%). XP-Endo Shaper allowed a regular biomechanical preparation with less dentinal wear compared with manual instrumentation, which showed excessive wear of the thin root canal walls (p < 0.05). Roundness and SMI showed similarity between both protocols (p > 0.05). XP-Endo Shaper SEM showed a regular and well-defined shape of the apical foramen suggesting the formation of the apical stop. Reduced diameter and taper instruments promoted a conservative wear and a well-defined apical stop formation in large root canals.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Cavidad Pulpar/diagnóstico por imagen , Microtomografía por Rayos X , Preparación del Conducto Radicular/métodos , Tratamiento del Conducto Radicular , Ápice del Diente/diagnóstico por imagen
12.
Braz. oral res. (Online) ; 37: e056, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1439745

RESUMEN

Abstract To investigate the influence of the remaining volume of a new intracanal medication based on bioceramic compounds on the bond strength (BS) and formation of an adhesive interface between calcium silicate-based and epoxy resin-based root canal sealers. For this purpose, the specimens were distributed according to the intracanal medication (n = 26): Bio-C Temp (BCT) and Ultracal XS (UXS). The roots were scanned in microCT, and after 7 days, the medication was removed. Then a new scan was performed to evaluate the volume of medication remaining. Subsequently, 40 specimens were redistributed into 2 subgroups (n = 10) and filled according to the sealer used: AH Plus (AHP) and Bio-C Sealer (BCS), to assess the bond strength by using the push-out test, and the adhesive interface by confocal laser fluorescence microscopy (CLSM) and scanning electron microscopy (SEM). The t test showed a smaller remainder of BCT (1.77 ± 0.86) compared with UXS (10.47 ± 5.78), irrespective of the root third evaluated. The BS showed that teeth with BCT + BCS had higher bond strength values (3.70 ± 1.22) when compared to the other groups: BCT + AHP (2.15 ± 1.07), UXS + BCS (3.18 ± 1.09) and UXS + AHP (2.11 ± 1.02) (p<0.001). The cervical third had higher BS when compared with the middle and apical thirds (p < 0.001), and higher number of adhesive failures. The adhesive interface in SEM and CLSM images showed better adaptation for the association between BCT + BCS. Intracanal medication and silicate-based endodontic sealer appeared to interact chemically by forming a biomineralizing layer, allowing for an increase in the bond strength and forming an adhesive interface between the materials, with no or less gap formation.

13.
Braz. oral res. (Online) ; 37: e096, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1520524

RESUMEN

Abstract The survival of endodontically treated teeth depends on the remaining tooth structure. The aim of this study was to evaluate the impact of different access cavities on root canal preparation, restorative protocol, and fracture resistance of endodontically treated teeth. Fifty-six mandibular molars were divided into control (n=8) and experimental (n=16) groups according to access cavity: Traditional, Conservative, and Truss; and redistributed (n=8) according to instrumentation protocols: Reciproc Blue and R-motion. After, teeth were scanned in micro-CT and then filled and redistributed according to composite resin restoration (n=8): Filtek One BulkFill and Filtek Z350. A new micro-CT scan was performed to analyze the restorative material. Then, samples were submitted to fracture resistance testing and the failure pattern was determined. Data were analyzed using paired T-test, ANOVA, Tukey, and chi-square tests (α=0.05). In Truss, R-Motion promoted less transportation in different thirds of root canals. Higher percentages of voids (5.05%) and filling material (11.7%) were observed in Truss. Fracture resistance values were higher for the control group, followed by Truss, Conservative, and Traditional. The predominant failure pattern was type-II. In Truss, reciprocating instruments with smaller taper showed less canal transportation. Also, Truss provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material. Thus, in Truss, reciprocating files with smaller taper showed less canal transportation, and these cavities provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material.

14.
Braz Oral Res ; 36: e115, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36287426

RESUMEN

This study evaluate shaping ability of heat-treated NiTi-alloy instruments associated with different final irrigation protocols in flattened root canals. Thirty human mandibular incisors with flattened root canals were divided into 5 groups (n = 10): (XP) Original Protocol XP-endo Shaper; (XP-WT) Original Protocol XP-endo Shaper with working time variation; (XP-K) XP-endo Shaper with kinematics variation; (XP-WTK) XP-endo Shaper with kinematics and working time variations; (Hyflex) Hyflex CM. For the variation in working time protocols the same sample of the XP-endo Shaper groups with and without kinematic variation were used. To evaluate final irrigation protocols, groups 1, 3 and 5 were submitted to 3 protocols: (NI) No irrigation (n = 2); (CI) conventional irrigation (n = 4), and (EndoVac) irrigation (n = 4). The samples were scanned by microcomputed tomography and prepared for scanning electron microscopy evaluation. Quantitative data were evaluated using the parametric ANOVA test, with statistical significance level set at 5%, and qualitative data obtained were compared to establish the agreement between examiners through the Kappa test. It was observed that in the analysis of XP-endo Shaper protocols, the additional working time did not cause difference in any of parameters evaluated (p > 0.05) in relation to time recommended by manufacturer. Compared to Hyflex, XP-K showed highest mean volume increase (p < 0.05) and lowest percentage of untouched walls (p < 0.05). In the qualitative evaluation, final irrigation protocol with EndoVac provided the best cleaning results when associated with XP-K and with Hyflex. Thus, supplementary techniques are effective tools to enhance cleaning and to promote higher touch of walls during root canal preparation.


Asunto(s)
Cavidad Pulpar , Calor , Humanos , Cavidad Pulpar/diagnóstico por imagen , Microtomografía por Rayos X , Preparación del Conducto Radicular , Aleaciones
15.
Adv Exp Med Biol ; 1370: 267-278, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35882802

RESUMEN

Adaptation of islet ß-cell mass and function under limiting or excess nutrient availability is critical for maintenance of glucose homeostasis. Taurine regulates islet function of obese mice in normal and low dietary protein conditions, but whether this involves remodeling of the endocrine pancreas architecture is not well understood. Here, we carried functional and morphometric evaluation of the endocrine pancreas of normal and protein-restricted mice fed a high-fat diet (HFD) and investigated the role of taurine supplementation. Weaned mice were placed in a normal (C) or a low-protein diet (R) for 6 weeks, followed by HFD for 8 weeks (CH and RH). Half of HFD groups received 5% taurine supplementation since weaning (CHT and RHT) until the end of the experiment. Isolated islets from both CH and RH groups showed increased insulin release in association with increased pancreas weight and independently of changes in islet or ß-cell area. In normal protein CHT mice, taurine supplementation prevented obesity-induced insulin hypersecretion and promoted increased islet and ß-cell areas in association with increased protein expression of the proliferation marker, PCNA. On a low-protein background, taurine effects on islet function and morphology were blunted, but it prevented obesity-induced DNA fragmentation. In summary, taurine regulates islet function and morphology to improve the adaptive response to diet-induced obesity, but these effects are dependent on adequate dietary protein levels.


Asunto(s)
Islotes Pancreáticos , Taurina , Animales , Dieta Alta en Grasa/efectos adversos , Proteínas en la Dieta/metabolismo , Suplementos Dietéticos , Insulina/metabolismo , Islotes Pancreáticos/metabolismo , Ratones , Obesidad/tratamiento farmacológico , Obesidad/metabolismo , Taurina/metabolismo , Taurina/farmacología
16.
Front Cardiovasc Med ; 9: 847809, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35811697

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) employs angiotensin-converting enzyme 2 (ACE2) as its receptor for cell entrance, and studies have suggested that upon viral binding, ACE2 catalytic activity could be inhibited; therefore, impacting the regulation of the renin-angiotensin-aldosterone system (RAAS). To date, only few studies have evaluated the impact of SARS-CoV-2 infection on the blood levels of the components of the RAAS. The objective of this study was to determine the blood levels of ACE, ACE2, angiotensin-II, angiotensin (1-7), and angiotensin (1-9) at hospital admission and discharge in a group of patients presenting with severe or critical evolution of coronavirus disease 2019 (COVID-19). We showed that ACE, ACE2, angiotensin (1-7), and angiotensin (1-9) were similar in patients with critical and severe COVID-19. However, at admission, angiotensin-II levels were significantly higher in patients presenting as critical, compared to patients presenting with severe COVID-19. We conclude that blood levels of angiotensin-II are increased in hospitalized patients with COVID-19 presenting the critical outcome of the disease. We propose that early measurement of Ang-II could be a useful biomarker for identifying patients at higher risk for extremely severe progression of the disease.

17.
Int Endod J ; 55(1): 124-136, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34687053

RESUMEN

AIM: To evaluate the shaping ability of several heat-treated nickel-titanium systems used to prepare root canals with moderate and severe curvature, in extracted mandibular molars, by micro-computed tomography, considering their variation in kinematics and design. METHODOLOGY: Curved-mesial roots of mandibular molars were randomly selected and assigned into 4 balanced experimental groups (n = 10), established by determining homogeneous 3D parameters of volume and surface area: R-Motion (RM) size 30, 0.04 taper (RM; FKG Dentaire), Reciproc Blue (RCB) size 25, 0.08 taper (RCB; VDW GmbH), HyFlex CM (HFX) size 30, 0.04 taper (HFX; Coltène Whaledent) and XP-endo Shaper size (XPS) 30, 0.01 taper (XPS; FKG Dentaire). The volume of irrigation was established at 10 ml of 2.5% NaOCl. Throughout the entire root canal preparation procedures, the samples were fixed in a vice submerged in a container with water monitored at 37°C. Dimensional cross-sectional measures of area, perimeter, roundness, major/minor diameters and 3-dimensional (volume, surface area, structure model index - SMI) parameters as well as the smallest dentine thickness along the cervical and middle root thirds were evaluated by micro-CT. Data were analysed using analysis of variance and post hoc Tukey tests (α = 5%). RESULTS: Reciproc Blue and XPS had significantly greater mean increases in cross-sectional area measurements, only in the middle third, when compared with RM and HFX (p < .05). RM, RCB and XPS had a similar increase in measurements of length and width of perimeter (p > .05), and HFX had significantly lower mean increases in perimeter values only when compared with XPS (p < .05). RCB and XPS had significantly greater mean increases in volume when compared with RM and HFX (p < .05). RM had a significantly lower difference in SMI after preparation, compared with RCB, HFX and XPS (p < .05). The smallest dentine thickness was observed after the use of RCB (p < .05), in the danger and safety zones. CONCLUSIONS: XP-endo Shaper and RM had a shaping ability similar to that of instruments with larger tapers, achieved with less dentine removal in danger and safe zones in curved-mesial canals of extracted molar teeth treated on a laboratory benchtop.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Cavidad Pulpar/diagnóstico por imagen , Diseño de Equipo , Diente Molar/diagnóstico por imagen , Diente Molar/cirugía , Níquel , Titanio , Microtomografía por Rayos X
18.
Braz. oral res. (Online) ; 36: e115, 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1403967

RESUMEN

Abstract This study evaluate shaping ability of heat-treated NiTi-alloy instruments associated with different final irrigation protocols in flattened root canals. Thirty human mandibular incisors with flattened root canals were divided into 5 groups (n = 10): (XP) Original Protocol XP-endo Shaper; (XP-WT) Original Protocol XP-endo Shaper with working time variation; (XP-K) XP-endo Shaper with kinematics variation; (XP-WTK) XP-endo Shaper with kinematics and working time variations; (Hyflex) Hyflex CM. For the variation in working time protocols the same sample of the XP-endo Shaper groups with and without kinematic variation were used. To evaluate final irrigation protocols, groups 1, 3 and 5 were submitted to 3 protocols: (NI) No irrigation (n = 2); (CI) conventional irrigation (n = 4), and (EndoVac) irrigation (n = 4). The samples were scanned by microcomputed tomography and prepared for scanning electron microscopy evaluation. Quantitative data were evaluated using the parametric ANOVA test, with statistical significance level set at 5%, and qualitative data obtained were compared to establish the agreement between examiners through the Kappa test. It was observed that in the analysis of XP-endo Shaper protocols, the additional working time did not cause difference in any of parameters evaluated (p > 0.05) in relation to time recommended by manufacturer. Compared to Hyflex, XP-K showed highest mean volume increase (p < 0.05) and lowest percentage of untouched walls (p < 0.05). In the qualitative evaluation, final irrigation protocol with EndoVac provided the best cleaning results when associated with XP-K and with Hyflex. Thus, supplementary techniques are effective tools to enhance cleaning and to promote higher touch of walls during root canal preparation.

19.
Front Endocrinol (Lausanne) ; 12: 701994, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34552556

RESUMEN

Obesity and insulin resistance (IR) are well-studied risk factors for systemic cardiovascular disease, but their impact on pulmonary hypertension (PH) is not well clarified. This study aims to investigate if diet-induced obesity induces PH and if peroxisome-proliferator-activated receptor (PPAR-γ) and/or endoplasmic reticulum (ER) stress are involved in this process. Mice were maintained on a high-fat diet (HFD) for 4 months, and IR and PH were confirmed. In a separate group, after 4 months of HFD, mice were treated with pioglitazone (PIO) or 4-phenylbutyric acid for the last month. The results demonstrated that HFD for at least 4 months is able to increase pulmonary artery pressure, which is maintained, and this animal model can be used to investigate the link between IR and PH, without changes in ER stress in the pulmonary artery. There was also a reduction in circulating adiponectin and in perivascular adiponectin expression in the pulmonary artery, associated with a reduction in PPAR-γ expression. Treatment with PIO improved IR and PH and reversed the lower expression of adiponectin and PPAR-γ in the pulmonary artery, highlighting this drug as potential benefit for this poorly recognized complication of obesity.


Asunto(s)
Dieta Alta en Grasa/efectos adversos , Estrés del Retículo Endoplásmico , Hipertensión Pulmonar/patología , Resistencia a la Insulina , Obesidad/complicaciones , PPAR gamma/antagonistas & inhibidores , Arteria Pulmonar/patología , Animales , Hipertensión Pulmonar/etiología , Hipertensión Pulmonar/metabolismo , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Obesos , PPAR gamma/genética , PPAR gamma/metabolismo , Arteria Pulmonar/metabolismo
20.
Viruses ; 13(2)2021 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-33669276

RESUMEN

Background: Coronavirus disease 19 (COVID-19) can develop into a severe respiratory syndrome that results in up to 40% mortality. Acute lung inflammatory edema is a major pathological finding in autopsies explaining O2 diffusion failure and hypoxemia. Only dexamethasone has been shown to reduce mortality in severe cases, further supporting a role for inflammation in disease severity. SARS-CoV-2 enters cells employing angiotensin-converting enzyme 2 (ACE2) as a receptor, which is highly expressed in lung alveolar cells. ACE2 is one of the components of the cellular machinery that inactivates the potent inflammatory agent bradykinin, and SARS-CoV-2 infection could interfere with the catalytic activity of ACE2, leading to the accumulation of bradykinin. Methods: In this case control study, we tested two pharmacological inhibitors of the kinin-kallikrein system that are currently approved for the treatment of hereditary angioedema, icatibant, and inhibitor of C1 esterase/kallikrein, in a group of 30 patients with severe COVID-19. Results: Neither icatibant nor inhibitor of C1 esterase/kallikrein resulted in changes in time to clinical improvement. However, both compounds were safe and promoted the significant improvement of lung computed tomography scores and increased blood eosinophils, which are indicators of disease recovery. Conclusions: In this small cohort, we found evidence for safety and a beneficial role of pharmacological inhibition of the kinin-kallikrein system in two markers that indicate improved disease recovery.


Asunto(s)
Bradiquinina/análogos & derivados , Tratamiento Farmacológico de COVID-19 , Proteína Inhibidora del Complemento C1/uso terapéutico , Sistema Calicreína-Quinina/efectos de los fármacos , Calicreínas/antagonistas & inhibidores , Adulto , Anciano , Bradiquinina/uso terapéutico , Estudios de Casos y Controles , Reposicionamiento de Medicamentos , Femenino , Humanos , Pulmón/efectos de los fármacos , Pulmón/patología , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...