Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
2.
Iowa Orthop J ; 44(1): 179-184, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38919353

RESUMEN

Background: Provisional stabilization of high-energy tibia fractures using temporary plate fixation (TPF) or external fixation (ex-fix) prior to definitive medullary nailing (MN) is a strategy common in damage control orthopaedics. There is a lack of comprehensive data evaluating outcomes between these methods. This study compares outcomes of patients stabilized with either TPF or ex-fix, and with early definitive MN only, assessing complications including nonunion and deep infection. Methods: A retrospective review was performed on adult patients with tibia fractures treated with MN followed until fracture union (≥3 months) at a single level-1 trauma center from 2014 to 2022. Medical records were evaluated for nonunion and deep infection. Demographics, injury characteristics, and fixation methods were recorded. Significance between patients who underwent TPF and ex-fix was compared with a matched cohort of early MN using Pearson's exact tests, independent t-tests, and one-way ANOVA, depending on the appropriate variable. Results: 81 patients were included; 27 were temporized with TPF (n = 12) or ex-fix (n = 15). 54 early MN cases defined the matched cohort. All groups had similar patient and fracture characteristics. The difference in rates of nonunion between groups was significant, with TPF, ex-fix, and early MN groups at 17, 40, and 11% respectively (p = 0.027). Early MN had lower rates of nonunion (11% vs. 40%, p = 0.017) and deep infection (13% vs. 40%, p = 0.028) compared to ex-fix. Conclusion: Temporary ex-fix followed by staged MN was associated with higher rates of nonunion and deep infection. There was no difference in complication rates between TPF and early definitive MN. These data suggest that ex-fix followed by MN of tibia fractures should be avoided in favor of early definitive MN when possible. If temporization is needed, TPF may be a better option than ex-fix. Level of Evidence: IV.


Asunto(s)
Placas Óseas , Fracturas de la Tibia , Humanos , Fracturas de la Tibia/cirugía , Masculino , Estudios Retrospectivos , Femenino , Adulto , Persona de Mediana Edad , Resultado del Tratamiento , Fijación de Fractura/métodos , Fijadores Externos , Fijación Intramedular de Fracturas/métodos , Curación de Fractura , Anciano , Fracturas no Consolidadas/cirugía
3.
Injury ; 55(8): 111662, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38897069

RESUMEN

PURPOSE: To identify a cohort of isolated medial tibial plateau fractures treated with surgical fixation and to categorize them by Moore and Wahlquist classifications in order to determine the rate of complications with each fracture morphology and the predictive value of each classification system. We hypothesized there would be high rates of neurovascular injury, compartment syndrome, and complications overall with a higher incidence of neurovascular injury in Moore type III rim avulsion fractures and Wahlquist type C fractures that enter the plateau lateral to the tibial spines. METHODS: Patients who presented to six Level I trauma centers between 2010 and 2021 who underwent surgical fixation for isolated medial tibial plateau fractures were retrospectively reviewed. Data including demographics, radiographs, complications, and functional outcomes were collected. RESULTS: One hundred and fifty isolated medial tibial plateau fractures were included. All patients were classified by the Wahlquist classification of medial tibial plateau fractures, and 139 patients were classifiable by the Moore classification of tibial plateau fracture-dislocations. Nine percent of fractures presented with neurovascular injury: 5 % with isolated vascular injury and 6 % with isolated nerve injury. There were no significant differences in neurovascular injury by fracture type (Wahlquist p = 0.16, Moore p = 0.33). Compartment syndrome developed in two patients (1.3 %). The average final range of motion was 0.8-122° with no difference by Wahlquist or Moore classifications (p = 0.11, p = 0.52). The overall complication rate was 32 % without differences by fracture morphology. The overall rate of return to the operating room (OR) was 25 %. CONCLUSIONS: Isolated medial tibial plateau fractures often represent fracture-dislocations of the knee and should receive a meticulous neurovascular exam on presentation with a high suspicion for neurovascular injury. No specific fracture pattern was found to be predictive of neurovascular injuries, complications, or final knee range of motion. Patients should be counseled pre-operatively regarding high rates of return to the OR after the index surgery.


Asunto(s)
Fijación Interna de Fracturas , Rango del Movimiento Articular , Fracturas de la Tibia , Humanos , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/complicaciones , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Adulto , Fijación Interna de Fracturas/métodos , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Anciano , Lesiones del Sistema Vascular/fisiopatología , Lesiones del Sistema Vascular/cirugía , Síndromes Compartimentales/etiología , Síndromes Compartimentales/cirugía , Centros Traumatológicos , Radiografía , Fracturas de la Meseta Tibial
4.
Eur J Orthop Surg Traumatol ; 34(6): 2909-2913, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38806688

RESUMEN

PURPOSE: The retrograde femoral nailing advanced (RFNA) system (DePuy synthes) is a commonly used implant for the fixation of low distal femur and periprosthetic fractures. There is concern that the rate of distal interlock screw back-out may be higher for the RFNA compared to other nails (ON). The purpose of this study was to evaluate the incidence of interlock screw back-out and associated screw removal for RFNA versus ON, along with associated risk factors. METHODS: A retrospective comparative study of patients who underwent retrograde nailing for a distal femur fracture at an academic level one trauma center was performed. The incidence of distal interlock screw back-out and need for screw removal were compared for RFNA versus a propensity score matched cohort who received other nails. RESULTS: One hundred and ten patients underwent retrograde nailing with the RFNA for a distal femur fracture from 2015 to 2022 (average age: 66, BMI: 32, 52.7% smokers, 54.5% female, 61.8%). There was a significantly higher rate of interlock back-out in the RFNA group compared to the ON (27 patients, 24.5% vs 12 patients, 10.9%, p = 0.01), which occurred 6.3 weeks postoperatively. Screw removal rates for back-out were not significantly different for the RFNA group versus ON (8 patients, 7.3% vs 3 patients, 2.7%, p = 0.12). CONCLUSION: In this retrospective comparative study of distal femur fractures treated with retrograde nailing, the RFNA implant was associated with an increased risk of distal interlock screw back-out compared to other nails.


Asunto(s)
Clavos Ortopédicos , Tornillos Óseos , Remoción de Dispositivos , Fracturas del Fémur , Fijación Intramedular de Fracturas , Humanos , Femenino , Fracturas del Fémur/cirugía , Masculino , Estudios Retrospectivos , Anciano , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/efectos adversos , Remoción de Dispositivos/estadística & datos numéricos , Remoción de Dispositivos/métodos , Persona de Mediana Edad , Factores de Riesgo , Puntaje de Propensión , Fracturas Femorales Distales
5.
Am J Clin Pathol ; 162(3): 297-301, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-38639326

RESUMEN

OBJECTIVES: Voxelotor can increase hemoglobin levels in patients living with sickle cell disease (SCD). A clinician who is monitoring voxelotor response may want to know whole-blood voxelotor concentration, but this cannot be measured in most clinical settings. However, voxelotor has been demonstrated to cause "peak splitting" in common methods of hemoglobin measurement such as capillary zone electrophoresis (CZE) and high-performance liquid chromatography (HPLC). We hypothesized that we could use the size of the peak split to estimate the whole-blood concentration. METHODS: Blood from people with SCD was dosed with known concentrations of voxelotor, and multiparameter regression was used to derive the relationship of voxelotor concentration to the degree of peak splitting observed. To validate these equations, 21 patients started on voxelotor at 1500 mg/d had blood samples drawn at days 0, 14, 30, and 60. Samples were sent out for gold standard voxelotor concentration testing. The derived equations were then used to calculate voxelotor concentration. RESULTS: Calculated concentrations correlated strongly with measured concentrations for both CZE (R2 = 0.83, P < .001) and HPLC (R2 = 0.76, P < .001). Voxelotor concentration also had a significant effect on increases in hemoglobin (R2 = 0.40, P < .001). CONCLUSIONS: Thus, peak splitting CZE and HPLC can be used to estimate voxelotor concentration.


Asunto(s)
Anemia de Células Falciformes , Humanos , Anemia de Células Falciformes/sangre , Cromatografía Líquida de Alta Presión/métodos , Electroforesis Capilar/métodos , Pirazinas/sangre , Adulto , Masculino , Femenino , Hemoglobinas/análisis , Benzaldehídos , Pirazoles
6.
J Orthop Trauma ; 38(7): e272-e276, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38578647

RESUMEN

SUMMARY: Tibial plateau fractures with severely displaced articular injuries and significant deformity to the surrounding metaphyseal bone (including the hyperextension varus bicondylar pattern) can be challenging to stabilize due to resulting large bone voids uncontained by metaphyseal cortex. The purpose of this report was to describe a technique to support the plateau articular surface in these cases and report on outcomes of a small series. This technique uses a small or mini fragment plate, contoured to function as an intraosseous shelf plate, with the "shelf" portion inserted into the bone beneath the articular surface to support it. This technique provides fixed-angle support to the fragment. There are some advantages of this technique compared to structural allograft, large volume ceramic bone void filler, a spine cage, or other trabecular metal object, including the ability to remove the plate later, ability to tension the plate against the depressed articular surface, ability to place screws or other allograft near the implant, wide availability of the implant, and familiarity of orthopaedic trauma surgeons with placing plates and screws to hold reductions. The technique is particularly useful in patterns with uncontained articular depression and a large metaphyseal void.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Fracturas de la Tibia , Humanos , Fracturas de la Tibia/cirugía , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Masculino , Persona de Mediana Edad , Femenino , Adulto , Resultado del Tratamiento , Anciano , Adulto Joven , Fracturas de la Meseta Tibial
7.
Trauma Case Rep ; 51: 100999, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38550962

RESUMEN

We describe a trifocal femur injury with intracapsular femoral neck fracture, diaphyseal fracture with bone loss, and distal complete articular (AO/OTA C type) fracture, an injury rarely described in the literature. Surgical management utilized a not-yet-reported implant combination: screw-side plate device for the intracapsular femoral neck, retrograde nail for the diaphysis, and lag screws plus mini fragment buttress plating for the distal fracture. The patient had uneventful fracture union with no changes in alignment. Given the rarity and complexity of this injury, there is little consensus on surgical technique and implant choice. This case demonstrates a modernized approach that may be useful for surgeons who encounter similar fracture patterns in their practice.

8.
Artículo en Inglés | MEDLINE | ID: mdl-37319362

RESUMEN

OBJECTIVES: The sagittal plane of the distal tibia has not been well-described. This study sought to characterize sagittal plane morphology, determine symmetry from side to side, and identify differences based on hindfoot alignment. METHODS: One hundred twelve bilateral lateral weight-bearing ankle radiographs were retrospectively evaluated (224 ankles). Hindfoot alignment was classified as neutral, planus, or cavus using the Meary angle. The angle between the diaphyseal and distal tibia axes was measured, and the apex location relative to the plafond was recorded. RESULTS: A mean distal tibia apex posterior angulation (DTAPA) of 2.0° (range -2° to 7°, SD = 2.06°) was located 8.0 cm proximal to the plafond. No difference was observed from side to side in DTAPA magnitude (P = 0.36) or location (P = 0.90). Planus alignment was associated with a significantly greater DTAPA (3.05°) as compared with neutral (1.89°) (P = 0.002) and cavus (1.25°) (P < 0.001) alignment. CONCLUSION: The distal tibia has an apex posterior angulation, suggesting that the true anatomic axis of the tibia terminates just posterior to the plafond center. Hindfoot alignment is related to distal tibia morphology. DTAPA symmetry indicates that contralateral imaging can be used to guide reconstruction of patient-specific anatomy and alignment. Knowledge of the DTAPA may help mitigate sagittal malalignment during distal tibia fracture surgery.


Asunto(s)
Pie , Tibia , Humanos , Tibia/diagnóstico por imagen , Tibia/cirugía , Estudios Retrospectivos , Extremidad Inferior , Tobillo
9.
Eur J Orthop Surg Traumatol ; 33(8): 3299-3305, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37284986

RESUMEN

PURPOSE: Interfragmentary strain influences whether a fracture will undergo direct and indirect fracture healing. Orthopedic trauma surgeons modulate strain and create optimal biomechanical environments for specific fracture patterns using fixation constructs. However, objective intraoperative interfragmentary strain measurement does not currently inform fixation strategy in common practice. This review identifies potential methods and technologies to enable intraoperative strain measurement for guiding optimal fracture fixation strategies. METHODS: PubMed, Scopus, and Web of Science were methodologically queried for manuscripts containing terms related to "bone fracture," "strain," "measurement," and "intraoperative." Manuscripts were systematically screened for relevance and adjudicated by three reviewers. Relevant articles describing methods to measure interfragmentary strain intraoperatively were summarized. RESULTS: After removing duplicates, 1404 records were screened initially. There were 49 manuscripts meeting criteria for in-depth review. Of these, four reports were included in this study that described methods applicable to measuring interfragmentary strain intraoperatively. Two of these reports described a method using instrumented staples, one described optical tracking of Kirschner wires, and one described using a digital linear variable displacement transducer with a custom external fixator. CONCLUSION: The four reports identified by this review describe potential methods to quantify interfragmentary strain after fixation. However, further studies are needed to confirm the precision and accuracy of these measurements across a range of fractures and fixation methods. Additionally, described methods require the insertion and likely removal of additional implants into the bone. Ideally, innovations that measure interfragmentary strain intraoperatively would provide dynamic biomechanical feedback for the surgeon to proactively modulate construct stability.


Asunto(s)
Fijación Interna de Fracturas , Fracturas Óseas , Humanos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Hilos Ortopédicos , Curación de Fractura , Toma de Decisiones , Fenómenos Biomecánicos
10.
J Am Acad Orthop Surg ; 31(13): 669-675, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37294617

RESUMEN

Modern blocking techniques are useful to achieve anatomic alignment and stable fixation during end-segment nailing. Whether with screws or drill bits, blocking implants can correct both angular and translational deformities. Understanding the biomechanics of blocking implants allows the surgeon to properly plan their placement based on principles rather than dogma. We use case examples to highlight updates in blocking techniques during acute surgical fixation and chronic deformity correction.


Asunto(s)
Fijación Intramedular de Fracturas , Humanos , Fijación Intramedular de Fracturas/métodos , Tornillos Óseos , Extremidad Inferior
11.
Trauma Case Rep ; 45: 100836, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37200771

RESUMEN

Case report: Traumatic hip dislocations require prompt diagnosis and reduction to preserve the native joint. The classic irreducible posterior hip fracture-dislocation has been described as an immobile, slightly flexed, and internally rotated hip on physical exam. Classically, this irreducible pattern is associated with an ipsilateral femoral head fracture. The purpose of our report is to present an irreducible posterior hip dislocation with preserved motion in the setting of an unstable pelvic ring injury without associated femoral head pathology. Despite lacking clinical features of an irreducible hip, closed reduction in the emergency and operating rooms was unsuccessful, even after frame application for pelvis stability. Persistent irreducibility necessitated open reduction, where the femoral head was found to be buttonholed through the posterior hip capsule and blocking reduction. Conclusion: A posteriorly dislocated hip with preserved motion in the setting of a concomitant unstable pelvic ring injury may belie the true locked nature of the femoroacetabular dislocation and high suspicion for femoral head incarceration is required. The description of this unique irreducible fracture pattern and the stepwise approach used for reduction may be useful for other surgeons who may encounter similar patterns of injury.

12.
Injury ; 54(2): 578-583, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36503839

RESUMEN

INTRODUCTION: An understanding of the sagittal plane morphology of the humerus is relevant during surgical fixation of humeral fractures but is not well described in the literature. The purpose of this study was to better characterize the native sagittal plane morphology of the humerus. MATERIALS AND METHODS: 170 patients with uninjured full length lateral humerus radiographs were retrospectively evaluated. The angle between the proximal humeral diaphyseal axis and the distal humeral diaphyseal axis was identified and measured. The proximal axis was defined by two points equidistant from the anterior and posterior cortex 10 mm and 100 mm distal to the metaphyseal flare, and the distal axis by two points at 10 mm and 50 mm proximal to the capitellum/trochlea. The relative location of the center of rotation of angulation (CORA) was calculated as a percentage of humeral length. RESULTS: 114 radiographs were included in the analysis (66 right humeri, 48 left humeri). The average apex posterior angulation was 6.5 +/- 2.9°. The CORA occurred at an average of 80% (SD+/-13%) of the length of the humerus (proximal to distal). Total humeral length and absolute distance to CORA were greater in males compared to females (364 ± 50 mm versus 326 ± 30 mm; p<0.001; 290 ± 68 mm versus 260 ± 48 mm; p=0.003), but there were no significant sex differences with respect to magnitude of the apex posterior angulation (p=0.077) or location of CORA as a percentage of total humeral length (p=0.916). There were no statistically significant associations between age and total humeral length (p=0.056), distance to CORA (p=0.130), location of CORA as percentage of total humeral length (p=0.753), or magnitude of angulation (p=0.075). CONCLUSION: An apex posterior bow consistently exists in the distal one-quarter of the humerus that is consistent across ages and between sexes. This normal anatomic bow is important to recognize to avoid an extension malreduction and has implications for implant fit and contouring.


Asunto(s)
Fracturas del Húmero , Húmero , Humanos , Masculino , Femenino , Estudios Retrospectivos , Húmero/diagnóstico por imagen , Húmero/cirugía , Húmero/anatomía & histología , Fracturas del Húmero/diagnóstico por imagen , Fracturas del Húmero/cirugía , Radiografía , Fijación Interna de Fracturas/métodos
13.
J Clin Med ; 11(22)2022 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-36431255

RESUMEN

In order to determine the impact of COVID-19 on the treatment and outcomes in patients with proximal femoral fracture's (PFF), we analyzed a national US sample. This is a retrospective review of American College of Surgery's (ACS) National Surgical Quality Improvement Program (NSQIP) for patients with proximal femoral fractures. A total of 26,830 and 26,300 patients sustaining PFF and undergoing surgical treatment were sampled during 2019 and 2020, respectively. On multivariable logistic regression, patients were less likely to have 'presence of non-healing wound' (p < 0.001), functional status 'independent' (p = 0.012), undergo surgical procedures of 'hemiarthroplasty'(p = 0.002) and 'ORIF IT, Peritroch, Subtroch with plates and screws' (p < 0.001) and to be 'alive at 30-days post-op' (p = 0.001) in 2020 as compared to 2019. Patients were more likely to have a case status 'emergent', 'loss of ≥10% body weight', discharge destination of 'home' (p < 0.001 for each) or 'leaving against medical advice' (p = 0.026), postoperative 'acute renal failure (ARF)' (p = 0.011), 'myocardial infarction (MI)' (p = 0.006), 'pulmonary embolism (PE)' (p = 0.047), and 'deep venous thrombosis (DVT)' (p = 0.049) in 2020 as compared to 2019. Patients sustaining PFF and undergoing surgical treatment during pandemic year 2020 differed significantly in preoperative characteristics and 30-day postoperative complications when compared to patients from the previous year.

14.
J Orthop Trauma ; 36(12): 610-614, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36399672

RESUMEN

OBJECTIVE: To evaluate whether a single proximal interlocking bolt was sufficient during the treatment of extra-articular femur fractures with retrograde medullary nailing. DESIGN: Retrospective comparative study. SETTING: Academic Level 1 trauma center. PATIENTS: The study included 136 patients with extra-articular femur fractures treated with retrograde medullary nailing who met inclusion and follow-up criteria. INTERVENTION: The intervention included surgical treatment for a femur fracture with retrograde medullary nailing, with comparisons made between those treated with a single proximal interlocking (1 IL) bolt and those treated with 2 proximal interlocking bolts (2 IL). MAIN OUTCOME MEASUREMENT: The main outcome measurements were as follows: (1) rate of nonunion and (2) rate of catastrophic implant failure. RESULTS: There was no difference in the rate of nonunion requiring surgical intervention between the 2 groups. There were no catastrophic failures in either group. CONCLUSIONS: A single proximal interlocking bolt may be sufficient when using retrograde nailing for the treatment of extra-articular femur fractures. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Fracturas del Fémur , Fijación Intramedular de Fracturas , Humanos , Fijación Intramedular de Fracturas/efectos adversos , Estudios Retrospectivos , Fracturas del Fémur/cirugía , Fracturas del Fémur/etiología , Fémur
15.
Foot Ankle Orthop ; 7(3): 24730114221126719, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36199379

RESUMEN

Background: The prevalence, indications, and preferred methods for gastrocnemius recession and tendo-Achilles lengthening-grouped as triceps surae lengthening (TSL) procedures-in foot and ankle trauma are supported by a scarcity of clinical evidence. We hypothesize that injury, practice environment, and training heritage are significantly associated with probability of performing adjunctive TSL in the operative management of foot and ankle trauma. Methods: A survey was distributed to members of the American Orthopaedic Foot & Ankle Society and the Orthopaedic Trauma Association. Participants rated how likely they would be to perform TSL at initial management, definitive fixation, and after weightbearing in the presence and absence of a positive Silfverskiöld test in 10 clinical scenarios of closed foot and ankle trauma. Results: A total of 258 surgeons with median 14 years' experience responded. Eighty-five percent reported foot and ankle fellowship training, 24% reported traumatology fellowship training, 13% both, and 4% no fellowship. Ninety-nine percent reported performing TSL with a median 25 TSL procedures per year, 72% open gastrocnemius recession, and 17% percutaneous tendo-Achilles lengthening). Across all scenarios, we observed low overall 8% probability with fair agreement (κ = 0.246) of performing TSL (range, 1% at initial management of an unstable Weber B bimalleolar ankle fracture with negative contralateral Silfverskiöld test to 29% at definitive fixation of tongue-type calcaneus fracture with positive contralateral Silfverskiöld test). Silfverskiöld testing significantly influenced TSL probability at all time points. University of Washington training (ß = 1.5, P = .007) but not trauma vs foot fellowship training, years in practice, academic practice, urban setting, or facility trauma designation were significantly associated with likelihood of performing TSL. Conclusion: Orthopaedic traumatology and foot and ankle surgeons report similar indications, methods, and low perceived propensity to use TSL in the management of foot and ankle trauma. We found that graduates of 1 fellowship training site were more likely to perform TSL in the setting of acute trauma potentially indicating the need for better scientific data to support this practice. Level of Evidence: Level V, therapeutic.

17.
J Am Acad Orthop Surg ; 30(15): e1015-e1024, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-35862213

RESUMEN

Talus fractures can be challenging injuries to treat because of complex talar shape, an abundance of articular cartilage, a potentially unforgiving soft-tissue envelope, and an easily injured blood supply. In addition, the spectra of energy involved, soft-tissue injury, and the fracture pattern are wide. Temporizing treatment is sometimes required, including débridement of open fractures, reduction of dislocations, and occasionally spanning external fixation. Definitive treatment first requires an understanding of the fracture pattern, including location and fracture line orientation. Multiple options for surgical exposure exist and are selected based on the fracture pattern and condition of the soft tissues. Newer fixation techniques, including the use of fixed-angle and minifragment implants, are useful in achieving stable fixation.


Asunto(s)
Fracturas de Tobillo , Fracturas Óseas , Luxaciones Articulares , Astrágalo , Fracturas de Tobillo/cirugía , Fijación de Fractura/métodos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Humanos , Astrágalo/lesiones , Astrágalo/cirugía
18.
Artículo en Inglés | MEDLINE | ID: mdl-35651664

RESUMEN

Musculoskeletal (MSK) education is underemphasized in medical school curricula, which can lead to decreased confidence in treating MSK conditions and suboptimal performance on orthopaedic surgery elective rotations or subinternships. Given the low amount of formalized education in MSK medicine, students aiming to learn about orthopaedic surgery must gain much of their foundational knowledge from other resources. However, there are currently no centralized introductory educational resources to fill this need. We provide a framework for navigating the different types of resources available for trainees and highlight the unaddressed needs in this area.

19.
Arch Orthop Trauma Surg ; 142(6): 955-959, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33417025

RESUMEN

INTRODUCTION: Septic arthritis following surgical treatment of a tibial plateau fracture is a rare complication, but it does occur, and the impact on long-term function is relatively unknown. The purpose of this study was to determine the long-term sequelae of septic arthritis among patients treated with internal fixation for a tibial plateau fracture and to determine the effect of timing (early or late infection) on the rate of such sequela. MATERIALS AND METHODS: A retrospective comparative study was designed using the trauma database of a single level I academic trauma center. Patients who developed culture-positive septic knee arthritis after internal fixation of a tibial plateau fracture, with 1-year follow-up, were included in the study. The number of debridement procedures required was recorded. Rates of long-term complications and implant removal were identified. Complications rates were compared between patients who developed early (within 30 days of definitive fixation) and late (more than 30 days) septic arthritis. RESULTS: The mean number of debridement procedures per patient was six. Fourteen patients (88%) required implant removal, and thirteen (81%) developed knee arthritis. There was a significantly lower rate of complications in the early septic arthritis group compared to the late group (3 of 6 patients or 50%, vs 10 of 10 patients or 100%; p = 0.036). CONCLUSIONS: Patients who developed septic arthritis following internal fixation of a tibial plateau fracture were likely to endure long-term sequelae. Early infection and detection led to fewer complications. Surgeons treating infectious complications in tibial plateau fracture patients should specifically seek to rule out septic arthritis, anticipate that implant removal may be necessary, and counsel these patients appropriately regarding the anticipated natural history of their condition. LEVEL OF EVIDENCE: III.


Asunto(s)
Artritis Infecciosa , Fracturas de la Tibia , Artritis Infecciosa/etiología , Artritis Infecciosa/cirugía , Fijación de Fractura/métodos , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Humanos , Reoperación , Estudios Retrospectivos , Fracturas de la Tibia/complicaciones , Fracturas de la Tibia/cirugía
20.
Cancer Cell ; 40(1): 3-5, 2022 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-34838186
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...