Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Vasc Surg ; 79(3): 562-568, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37979925

RESUMEN

OBJECTIVE: The Harborview Risk Score (HRS) is a simple, accurate 4-point preoperative risk scoring system used to predict 30-day mortality following ruptured abdominal aortic aneurysm (rAAA) repair. The HRS assigns 1 point for each of the following: age >76 years, pH <7.2, creatinine >2 mg/dL, and any episode of severe hypotension (systolic blood pressure <70 mmHg). One potential limitation of this risk scoring system is that arterial blood gas (ABG) analysis is required to determine arterial pH. Because ABG analysis is not routinely performed prior to patient transfer or rAAA repair, we sought to determine if the HRS could be modified by replacing pH with the international normalized ratio (INR), a factor that has been previously shown to have a strong and independent association with 30-day death after rAAA repair. METHODS: A retrospective review of all rAAA repairs done at a single academic medical center between January 2002 and December 2018 was performed. Our traditional HRS was compared with a modified score, in which pH <7.2 was replaced with INR >1.8. Patients were included if they underwent rAAA repair (open or endovascular), and if they had preoperative laboratory values available to calculate both the traditional and modified HRS. RESULTS: During the 17-year study period, 360 of 391 repairs met inclusion criteria. Observed 30-day mortality using the modified scoring system was 17% (18/106) for a score of 0 points, 43% (53/122) for 1 point, 54% (52/96) for 2 points, 84% (27/32) for 3 points, and 100% (4/4) for 4 points. Receiver operating characteristic analysis revealed similar ability of the two scoring systems to predict 30-day death: there was no significant difference in the area under the curve (AUC) comparing the traditional (AUC = 0.74) and modified (AUC = 0.72) HRS (P = .3). CONCLUSIONS: Although previously validated among a modern cohort of patients with rAAA, our traditional 4-point risk score is limited in real-world use by the need for an ABG. Substituting INR for pH improves the usefulness of our risk scoring system without compromising accuracy in predicting 30-day mortality after rAAA repair.


Asunto(s)
Aneurisma de la Aorta Abdominal , Rotura de la Aorta , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Anciano , Técnicas de Apoyo para la Decisión , Factores de Tiempo , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Resultado del Tratamiento , Valor Predictivo de las Pruebas , Factores de Riesgo , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular/efectos adversos , Medición de Riesgo
2.
J Vasc Surg ; 74(5): 1508-1518, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33957228

RESUMEN

OBJECTIVE: Various risk score calculators used to predict 30-day mortality after treatment of ruptured abdominal aortic aneurysms (rAAAs) have produced mixed results regarding their usefulness and reproducibility. We prospectively validated the accuracy of our preoperative scoring system in a modern cohort of patients with rAAAs. METHODS: A retrospective review of all patients wiith rAAAs who had presented to a single academic center from January 2002 to December 2018 was performed. The patients were divided into three cohorts according to when the institutional practice changes had occurred: the pre-endovascular aneurysm repair (EVAR) era (January 2002 to July 2007), the pre-Harbor View risk score era (August 2007 to October 2013), and the modern era (November 2013 to December 2018). The primary outcome measure was 30-day mortality. Our preoperative risk score assigns 1 point for each of the following: age >76 years, pH <7.2, creatinine >2 mg/dL, and any episode of hypotension (systolic blood pressure <70 mm Hg). The previously reported mortality from a retrospective analysis of the first two cohorts was 22% for 1 point, 69% for 2 points, 78% for 3 points, and 100% for 4 points. The goal of the present study was to prospectively validate the Harborview scoring system in the modern era. RESULTS: During the 17-year study period, 417 patients with rAAAs were treated at our institution. Of the 118 patients treated in the modern era, 45 (38.1%) had undergone open aneurysm repair (OAR), 61 (51.7%) had undergone EVAR, and 12 (10.2%) had received comfort measures only. Excluding the 12 patients without aneurysm repair, we found a statistically significant linear trend between the preoperative risk score and subsequent 30-day mortality for all patients combined (P < .0001), for OAR patients alone (P = .0003), and for EVAR patients alone (P < .0001). After adjustment for the Harborview risk score, the 30-day mortality was 41.3% vs 31.6% after OAR vs EVAR, respectively (P = .2). For all repairs, the 30-day mortality was 14.6% for a score of 0, 35.7% for a score of 1, 68.4% for a score of 2, and 100% for a score of 3 or 4. CONCLUSIONS: Our results, representing one of the largest modern series of rAAAs treated at a single institution, have confirmed the accuracy of a simple 4-point preoperative risk score in predicting 30-day mortality in the modern rAAA patient. Such tools should be used when discussing the treatment options with referring physicians, patients, and their family members to help guide transfer and treatment decision-making.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular/mortalidad , Técnicas de Apoyo para la Decisión , Procedimientos Endovasculares/mortalidad , Factores de Edad , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/fisiopatología , Rotura de la Aorta/diagnóstico , Rotura de la Aorta/mortalidad , Rotura de la Aorta/fisiopatología , Biomarcadores/sangre , Presión Sanguínea , Implantación de Prótesis Vascular/efectos adversos , Creatinina/sangre , Bases de Datos Factuales , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Concentración de Iones de Hidrógeno , Hipotensión/fisiopatología , Hipotensión/cirugía , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
3.
J Vasc Surg ; 71(5): 1515-1520, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31635961

RESUMEN

OBJECTIVE: Renal volume has been shown to correlate with renal function. Renal volume and renal function both decline steadily in the sixth decade of life and beyond. We sought to assess (1) the inter-rater reliability for manually measuring renal volume using computed tomography and (2) change in renal volume over time as it relates to renal function in fenestrated endovascular aortic aneurysm repair (FEVAR). METHODS: This study was conducted as part of a physician-sponsored investigational new device (#NCT01538056). First, 30 consecutive kidneys of preoperative FEVAR patients were independently measured by two raters using manual segmentation and three-dimensional modeling software. Renal volumes were calculated and compared. Intraclass correlation was calculated between the two observers. Second, renal volumes were then recorded for 85 patients undergoing FEVAR with follow-up out to 5 years. Demographic data, comorbidities, creatinine, glomerular filtration rate (GFR), renal artery stenosis or occlusion, and bilateral renal volume measurements were analyzed. Multivariate analysis was performed to delineate association of these variables with total renal volume (TRV). RESULTS: The intraclass correlation coefficient for our renal volume measurements was 0.97 (95% confidence interval, 0.81-0.99), indicating excellent correlation. Renal volume was strongly correlated with GFR. Our multivariate analysis model predicts a 17.9 mL/min increase in GFR with each 20% increase in TRV. After adjustment for all other known correlates of renal function, renal volume remained as the only significant predictor of renal function. CONCLUSIONS: Renal volume can be measured with high reliability using manual segmentation and computed tomography scans. In our baseline analysis, TRV was strongly correlated with renal function. These findings support the potential for renal volume as a surrogate for renal function.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Riñón/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Ensayos Clínicos como Asunto , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Imagenología Tridimensional , Riñón/fisiopatología , Masculino , Variaciones Dependientes del Observador , Tamaño de los Órganos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
4.
J Vasc Surg ; 64(5): 1219-1227, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27575815

RESUMEN

OBJECTIVE: The objective of this study was to evaluate the learning curve for fenestrated endovascular aortic aneurysm repair (FEVAR). METHODS: Data were collected prospectively on all FEVAR procedures conducted by a single surgeon between June 2007 and January 2015. During the study period, 136 FEVARs were performed, and this experience was divided into four quartiles each consisting of 34 cases. Clinical outcomes evaluated included perioperative death and major complications. Process outcomes included length of procedure, fluoroscopy time, contrast material use, estimated blood loss, and intensive care unit length of stay. RESULTS: During the study period, there was a statistically significant increase in the complexity of cases as evidenced by an increase in the proportion of cases with two or more fenestrations from 52.9% in the first quartile to 88.2% in the fourth quartile (P = .001). Despite this, there was a steady decrease in the proportion of patients suffering perioperative death or major complications from 23.5% in the first quartile to 8.8% in the fourth quartile. After adjustment for potential confounding factors, the odds of death or major complication were cut by 52.4% per quartile increase (95% confidence interval [CI], 7.8%-75.5%; P = .028). In addition, among cases with two or more fenestrations, geometric mean length of procedure was reduced from 223.8 minutes in the first quartile to 149.6 minutes in the fourth quartile, and geometric mean fluoroscopy time was reduced from 58.6 minutes in the first quartile to 31.5 minutes in the fourth quartile. After adjustment, there was an estimated 9.9% reduction in geometric mean procedure length per quartile increase (95% CI, 3.5%-15.9%; P = .003) and a 17.6% reduction in geometric mean fluoroscopy time per quartile increase (95% CI, 10.9%-23.8%; P < .0001). CONCLUSIONS: Despite an increase in case complexity, there was evidence for significant improvement in important clinical and process outcomes during the study period. We believe that much of this improvement was attributable to several key advances in the FEVAR procedure that were instituted during the study period and are discussed herein.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/métodos , Competencia Clínica , Procedimientos Endovasculares/métodos , Curva de Aprendizaje , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Pérdida de Sangre Quirúrgica , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Medios de Contraste/administración & dosificación , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Fluoroscopía , Mortalidad Hospitalaria , Humanos , Tiempo de Internación , Masculino , Tempo Operativo , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Diseño de Prótesis , Mejoramiento de la Calidad , Indicadores de Calidad de la Atención de Salud , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Washingtón
5.
J Vasc Surg ; 58(2): 529-34, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23642923

RESUMEN

Endovascular reconstruction of the femoral and popliteal arteries is replacing femoral-popliteal bypass. This is made possible by subintimal recanalization to manage long chronic total occlusions. Re-entry into the true lumen is the most challenging step in this process. This article summarizes the techniques for re-entry into the true lumen in the superficial femoral and above- and below-the-knee popliteal arteries.


Asunto(s)
Arteriopatías Oclusivas/terapia , Procedimientos Endovasculares , Arteria Femoral , Arteria Poplítea , Arteriopatías Oclusivas/diagnóstico por imagen , Constricción Patológica , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Diseño de Equipo , Arteria Femoral/diagnóstico por imagen , Humanos , Arteria Poplítea/diagnóstico por imagen , Radiografía Intervencional , Resultado del Tratamiento , Dispositivos de Acceso Vascular
6.
J Vasc Surg ; 47(5): 960-6; discussion 966, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18372146

RESUMEN

OBJECTIVE: The optimal treatment for hemodynamically significant infrainguinal vein bypass graft stenosis is not known. This study compares three options as first choice for the revision of failing infrainguinal vein grafts: cutting balloon angioplasty (CBA), standard percutaneous transluminal balloon angioplasty (PTA), and open surgical revision (OS). METHODS: Infrainguinal vein bypass graft lesions treated in a single institution during a 12-year period were evaluated. Of these, 161 lesions in 124 infrainguinal bypasses (101 patients) were treated with OS (n = 42), PTA (n = 57), or CBA (n = 62). The initial indication for the bypass in these patients was limb salvage in 73% and claudication in 27%. The primary outcome of interest was the development of vein graft occlusion or significant stenosis (>or=70%) as detected by surveillance duplex ultrasound scanning or arteriography some time after repair. RESULTS: The stenosis-free patency rates at 48 months for OS, CBA, and PTA were 74%, 62%, and 34%, respectively. PTA was associated with an increased risk of treatment failure compared with both OS (hazard ratio [HR], 3.9; P < .0001) and CBA (HR, 3.1; P < .0001). There was no significant difference between OS and CBA (HR, 1.3 for CBA vs OS, P = .6). Pseudoaneurysms developed in two CBA patients. One ruptured and required interposition graft, and one was monitored. CONCLUSION: Cutting balloon angioplasty is a reasonable, initial treatment for infrainguinal vein graft stenosis in most patients. It is a safe, minimally invasive, outpatient procedure with patency rates that are comparable to OS and superior to PTA.


Asunto(s)
Angioplastia de Balón , Oclusión de Injerto Vascular/terapia , Isquemia/cirugía , Extremidad Inferior/irrigación sanguínea , Selección de Paciente , Vena Safena/trasplante , Procedimientos Quirúrgicos Vasculares , Anciano , Anciano de 80 o más Años , Angiografía , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/métodos , Constricción Patológica , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/patología , Oclusión de Injerto Vascular/fisiopatología , Oclusión de Injerto Vascular/cirugía , Humanos , Isquemia/patología , Isquemia/fisiopatología , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Estudios Retrospectivos , Medición de Riesgo , Insuficiencia del Tratamiento , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Grado de Desobstrucción Vascular , Procedimientos Quirúrgicos Vasculares/efectos adversos
7.
Perspect Vasc Surg Endovasc Ther ; 17(2): 97-109, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16110371

RESUMEN

Carotid angioplasty and stenting requires delivery of therapy through a sheath rather than open vascular access. Safe and successful sheath delivery facilitates the carotid angioplasty and stenting procedure and depends upon an ability to assess the aortic arch, catheterize its branches, perform remote access guidewire-catheter manipulation, and place a sheath.


Asunto(s)
Angioplastia de Balón/métodos , Arterias Carótidas , Estenosis Carotídea/terapia , Cateterismo/métodos , Angioplastia de Balón/instrumentación , Arterias Carótidas/anatomía & histología , Cateterismo/instrumentación , Humanos
8.
J Vasc Surg ; 41(2): 238-45, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15768005

RESUMEN

OBJECTIVE: Carotid arteriography (CA) is an important method of assessing carotid artery occlusive disease and is the best method of planning for carotid angioplasty and stent placement (CAS). This study compared the results of CA performed by vascular surgeons in a contemporary series against widely recognized interdisciplinary quality standards for this procedure. Although many vascular surgeons perform CA, there is a paucity of data about its safety, efficacy, and compliance with quality standards in vascular practice. The importance of quality CA will likely increase as CAS emerges to assume a broader clinical role. METHOD: Carotid arteriograms performed by seven vascular surgeons at three institutions from September 2000 to May 2004 were reviewed. These results were compared with quality standards for the performance of CA. RESULTS: Five hundred three carotid arteriograms were performed over 45 months. Indications for the procedure were extracranial cerebrovascular disease (86%), trauma (5%), and other conditions (9%). Indications for the procedure were appropriate in 100% of patients (as determined by guidelines document) and exceeded the recommended standard of appropriate indications in 99%. All procedures successfully provided the information required, exceeding the threshold of 98% for procedural success. Reversible neurologic deficits occurred in 0.6% (two transient ischemic attacks and one stroke) compared with the threshold of 2.5%. A permanent neurologic deficit occurred in 0.2% (1 patient) compared with the published guideline of 1% after carotid arteriography. Major non-neurologic complications occurred in 1.2% (6 patients), less than the standard of 2.0%. CONCLUSIONS: The safety and efficacy of a contemporary series of CA performed in vascular surgery practice compared favorably with recognized interdisciplinary quality standards for this procedure. Ensuring safe and effective CA is likely to support the successful growth of CAS as a treatment option.


Asunto(s)
Angiografía/normas , Estenosis Carotídea/diagnóstico por imagen , Cirugía General/normas , Anciano , Anciano de 80 o más Años , Arterias Carótidas/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Estándares de Referencia , Resultado del Tratamiento
9.
J Vasc Surg ; 40(1): 24-9, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15218458

RESUMEN

INTRODUCTION: There are no published reports on the association between ethnicity and outcome after aortoiliac stent grafting to treat aneurismal disease. Because Hawaii is a state with an ethnically diverse population, we conducted a retrospective study to examine this potential association. We hypothesized that individuals of Asian ancestry may have higher complication rates after endovascular repair compared with non-Asians. METHODS: All endovascular devices placed to treat aneurysm disease from 1996 to 2003 were evaluated in two institutions. The association between ethnicity and access-related and device-related complications, both periprocedural and delayed, was examined with logistic regression analysis. RESULTS: Ninety-two aortoiliac endografts were placed during the study period, including 87 in patients with abdominal aortic aneurysms with or without iliac aneurysm disease, and five patients with isolated iliac artery aneurysms. Forty-four percent of patients were categorized as Asian, 39% as white, 16% as Pacific Islander, and 1% as African American. Access-related and device-related complications (ADRCs) occurred in 11 of 92 (12%) of these patients. The following parameters were significantly associated with ADRCs: Asian ethnicity (P =.015), age greater than 80 years (P =.02), and external iliac diameter smaller than 7.5 mm (P =.01). Asian patients were more likely to have experienced ADRCs than were non-Asian patients (odds ratio, 7.3; 95% confidence interval, 1.5-35.8; P =.015). Asians also had smaller external iliac artery diameters (P =.0003) and more tortuous iliac arteries (P =.03) compared with non-Asians. After adjusting for iliac artery diameter and tortuosity, the association between Asian ethnicity and ARDCs became nonsignificant (P =.074), which suggests that the association between race and complications may be at least in part due to small and tortuous iliac arteries. There was no association between age, gender, or ethnicity and postoperative detection of endoleak. CONCLUSION: Our data indicate that individuals of Asian ancestry are far more likely to experience adverse access-related and device-related complications after aortoiliac stent grafting than are non-Asians. We found that this association is at least partly attributable to the smaller and more tortuous iliac arteries in persons of Asian ancestry.


Asunto(s)
Aneurisma de la Aorta Abdominal/etnología , Aneurisma de la Aorta Abdominal/cirugía , Pueblo Asiatico , Implantación de Prótesis Vascular/efectos adversos , Aneurisma Ilíaco/etnología , Aneurisma Ilíaco/cirugía , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Femenino , Arteria Femoral , Hawaii , Humanos , Arteria Ilíaca/anatomía & histología , Masculino , Persona de Mediana Edad , Factores de Riesgo , Stents/efectos adversos , Resultado del Tratamiento
10.
J Diabetes Complications ; 16(2): 165-71, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12039400

RESUMEN

STATEMENT OF THE PROBLEM: Medial arterial calcinosis (MAC) is associated with neuropathy, amputation, and mortality through an unknown mechanism. We hypothesized that MAC was a marker of autonomic neuropathy rather than a risk factor and that the outcomes were due to autonomic neuropathy. METHODS: All subjects in an ongoing prospective study of diabetic foot conditions in a diabetic veteran cohort who received a foot radiograph between 11/7/90 and 11/5/93 were included. Autonomic neuropathy measured as either heart rate variability with timed respiration or postural hypotension. A logistic model predicted the presence of MAC at baseline and Cox proportional models assessed the relative contribution of autonomic neuropathy and traditional risk factors for the outcomes of ulceration, amputation, and death. RESULTS: MAC was identified in 181 subjects, no MAC in 253 subjects, and 39 were excluded due to disagreement between observers. Both measures of autonomic neuropathy were independent predictors of MAC at baseline, even after adjustment for vibration sensation loss in a logistic model. MAC was associated with an increased risk for ulceration (hazards ratio, HR: 2.1, 95% confidence intervals, CI, 1.4-3.1), amputation (HR 3.3, 95% CI 1.5-7.4), and mortality (HR 1.6, 95% CI 1.1-2.2). The addition of either autonomic measure of neuropathy did not change the MAC HR or significantly improved the fit of the model. CONCLUSIONS: Our hypothesis that the excess mortality, amputation, and ulceration in persons with MAC could be explained by autonomic neuropathy measured as postural hypotension or heart rate variability with measured respiration was not supported.


Asunto(s)
Arteriosclerosis/fisiopatología , Diabetes Mellitus/fisiopatología , Neuropatías Diabéticas/fisiopatología , Veteranos , Edad de Inicio , Amputación Quirúrgica/estadística & datos numéricos , Complicaciones de la Diabetes , Pie Diabético/epidemiología , Etnicidad , Humanos , Estudios Longitudinales , Persona de Mediana Edad , Examen Neurológico , Pronóstico , Fumar , Cese del Hábito de Fumar , Resultado del Tratamiento , Estados Unidos
11.
J Trauma ; 52(1): 112-6, 2002 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11791060

RESUMEN

BACKGROUND: Although epidemiologic studies of the general population have demonstrated a deficit of blood group O among patients with deep venous thrombosis (DVT), few studies have evaluated the importance of blood group in high-risk patients. The purpose of this study was to evaluate the importance of ABO blood group as a thrombotic risk factor in injured patients. METHODS: Injured patients with a discharge diagnosis of DVT were identified from an institutional trauma registry and compared with control patients matched for age and Injury Severity Score. ABO blood types of patients and controls were obtained from the regional blood center database. RESULTS: Three hundred forty-three case-control pairs were identified from a total of 401 consecutive cases of DVT. Blunt injury was the predominant mechanism of injury, accounting for 90.4% of cases. Chest (p = 0.01) and extremity (p < 0.001) Abbreviated Injury Scale scores were independent predictors of DVT. However, there was no significant difference in blood group distribution or the A to O ratio between patients with and without DVT. For non-type O patients, the odds ratio for developing DVT was 1.1 (95% confidence interval, 0.8-1.5; p = 0.5) in comparison with type O patients. CONCLUSION: These data do not support a clinically relevant association between blood type and DVT in trauma patients. Injury-associated derangements of coagulation may be more important than any hypercoagulability related to blood type in this population.


Asunto(s)
Sistema del Grupo Sanguíneo ABO/efectos adversos , Sistema del Grupo Sanguíneo ABO/sangre , Trombosis de la Vena/sangre , Trombosis de la Vena/etiología , Heridas y Lesiones/sangre , Heridas y Lesiones/complicaciones , Escala Resumida de Traumatismos , Adulto , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Puntaje de Gravedad del Traumatismo , Tiempo de Internación , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA