Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Int J Radiat Oncol Biol Phys ; 105(2): 394-399, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31283978

RESUMEN

PURPOSE: To compare normal tissue dosimetry between hippocampal-avoidance whole brain radiation therapy (HA-WBRT) and stereotactic radiosurgery (SRS) in patients with 10 to 30 brain metastases, and to describe a novel SRS strategy we term Spatially Partitioned Adaptive RadiosurgEry (SPARE). METHODS AND MATERIALS: A retrospective review identified SRS treatment plans with >10 brain metastases located >5 mm from the hippocampi. Our Gamma Knife Icon (GKI) SPARE (GKI-Spr) technique treats multiple metastases with single-fraction SRS partitioned over consecutive days while limiting the total treatment time to ≤60 minutes per day. Hippocampal and normal brain dosimetry were compared among GKI-Spr, single-fraction single-day GKI (GKI-Sfr), and 30 Gy in 10 fractions HA-WBRT. Dose metrics were converted to equivalent dose in 2 Gy fractions. RESULTS: Ten cases were analyzed. Compared with HA-WBRT, GKI-Spr significantly reduced the median equivalent dose in 2 Gy fractions hippocampal maximum point dose, mean dose, and dose to 40% of the hippocampi (D40%) by 86%, 93%, and 93%, respectively, and similarly for GKI-Sfr by 81%, 92%, and 91%, respectively. The normal brain median mean dose was reduced by 95% with GKI-Spr and 94% with GKI-Sfr. Compared with GKI-Sfr, GKI-Spr further reduced all normal brain and hippocampal dose metrics (P ≤ .014). CONCLUSIONS: GKI yields superior hippocampal and normal brain dosimetry compared with HA-WBRT, and GKI-Spr results in further dosimetric advantages.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundario , Irradiación Craneana/métodos , Hipocampo/efectos de la radiación , Tratamientos Conservadores del Órgano/métodos , Órganos en Riesgo/efectos de la radiación , Radiocirugia/métodos , Algoritmos , Encéfalo/efectos de la radiación , Humanos , Dosificación Radioterapéutica , Estudios Retrospectivos
2.
Pract Radiat Oncol ; 8(2): 116-122, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29329996

RESUMEN

INTRODUCTION: Radiation therapy is a standard treatment option for prostate cancer. With growing use of escalated doses and tighter margins, procedures to limit rectal size variation are needed to reduce prostate motion, increase treatment accuracy, and minimize rectal toxicity. This prospective study was done to determine whether the introduction of an antiflatulent medication would decrease rectal distention at computed tomography (CT) simulation and throughout a course of radiation therapy. METHODS AND MATERIALS: Patients undergoing a radical course of radiation therapy to the prostate/prostate bed were eligible to participate. Participants were randomly assigned to the intervention arm (antiflatulent medication) or the control arm (no medication). For each participant, the number of CT simulation rescans was recorded. Rectal diameters were measured on CT simulation and treatment cone beam CT scans. Acute rectal toxicities were assessed at baseline and weekly using National Cancer Institute Common Terminology Criteria for Adverse Events (NCI CTCAE), version 4.0. A χ2 analysis was used to compare the number of participants requiring a rescan in each study arm. Change in rectal diameter over time was assessed using repeated measures analysis of variance. RESULTS: A total of 78 patients participated, with equal numbers assigned to each study arm. There was no significant difference between arms in the number of participants requiring a CT simulation rescan (P = .5551). There was no significant variation in rectal diameter between arms (P = .8999); however, there was a significant effect of time (P = .0017) and a significant interaction effect between study arm and time on rectal diameter (P = .0141). No acute rectal toxicities above grade 2 were reported. CONCLUSIONS: The addition of antiflatulent medication did not affect the frequency of CT simulation rescans. Both time and the interaction between study arm and time had a statistically significant effect on rectal diameter, although neither finding was clinically significant. Instead, standardized bowel preparation education developed for this study may have been sufficient to limit rectal size variation.


Asunto(s)
Antiespumantes/uso terapéutico , Neoplasias de la Próstata/tratamiento farmacológico , Neoplasias de la Próstata/radioterapia , Radioterapia Guiada por Imagen/métodos , Anciano , Antiespumantes/farmacología , Humanos , Masculino
3.
Nurse Pract ; 39(10): 1-10, 2014 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-25225972

RESUMEN

Thirty years ago, Parkinson disease was described as a shortage of the neurotransmitter dopamine. Today, understanding of this disorder includes possible genetic influences, premorbid and nonmotor issues, and a variety of neurologic, cognitive, and psychiatric symptoms. Using a case study, this article presents the current science of Parkinson disease.


Asunto(s)
Enfermedad de Parkinson/enfermería , Humanos , Masculino , Persona de Mediana Edad , Enfermeras Practicantes , Evaluación en Enfermería , Enfermedad de Parkinson/genética , Enfermedad de Parkinson/patología , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...