Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
ACS Sens ; 9(6): 3307-3315, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38826054

RESUMEN

Fluorescent nanosensors have revolutionized diagnostics and our ability to monitor cellular dynamics. Yet, distinguishing sensor signals from autofluorescence remains a challenge. Here, we merged optode-based sensing with near-infrared-emitting ZnGa2O4:Cr3+ persistent luminescence nanoparticles (PLNPs) to create nanocomposites for autofluorescence-free "glow-in-the-dark" sensing. Hydrophobic modification and incorporation of the persistent luminescence nanoparticles into an optode-based nanoparticle core yielded persistent luminescence nanosensors (PLNs) for five analytes (K+, Na+, Ca2+, pH, and O2) via two distinct mechanisms. We demonstrated the viability of the PLNs by quantifying K+ in fetal bovine serum, calibrating the pH PLNs in the same, and ratiometrically monitoring O2 metabolism in cultures of Saccharomyces cerevisiae, all the while overcoming their respective autofluorescence signatures. This highly modular platform allows for facile tuning of the sensing functionality, optical properties, and surface chemistry and promises high signal-to-noise ratios in complex optical environments.


Asunto(s)
Saccharomyces cerevisiae , Saccharomyces cerevisiae/química , Oxígeno/química , Nanopartículas/química , Concentración de Iones de Hidrógeno , Animales , Mediciones Luminiscentes/métodos , Técnicas Biosensibles/métodos , Luminiscencia , Potasio/análisis , Bovinos
2.
J Microbiol Biol Educ ; : e0021223, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38814091

RESUMEN

Winogradsky columns were invented by Sergei Winogradsky in the 1880s and have commonly been used as a microbiology classroom learning tool in K-12 and collegiate education. However, they can be challenging to examine with microscopy. We scaled down Winogradsky columns into nuclear magnetic resonance (NMR) tubes and replaced the natural sediment with a transparent soil substitute toward the goal of observing the microbial growth under a bright-field microscope without column disassembly. Using this "Mini Winnie" approach, students can practice their microscopy skills while observing microbial growth inside the column after only days of incubation on the laboratory windowsill. Overall, we believe that the Mini Winnies provide a simple method for maximizing student engagement while giving them a greater understanding of how microorganisms interact in the environment.

3.
PLoS One ; 19(3): e0299875, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38498588

RESUMEN

The widespread availability and diversity of open-source microcontrollers paired with off-the-shelf electronics and 3D printed technology has led to the creation of a wide range of low-cost scientific instruments, including microscopes, spectrometers, sensors, data loggers, and other tools that can be used for research, education, and experimentation. These devices can be used to explore a wide range of scientific topics, from biology and chemistry to physics and engineering. In this study, we designed and built a multifunction fluorescent open source in vivo/in vitro imaging system (openIVIS) system that integrates a Raspberry Pi with commercial cameras and LEDs with 3D printed structures combined with an acrylic housing. Our openIVIS provides three excitation wavelengths of 460 nm, 520 nm, and 630 nm integrated with Python control software to enable fluorescent measurements across the full visible light spectrum. To demonstrate the potential applications of our system, we tested its performance against a diverse set of experiments including laboratory assays (measuring fluorescent dyes, using optical nanosensors, and DNA gel electrophoresis) to potentially fieldable applications (plant and mineral imaging). We also tested the potential use for a high school biology environment by imaging small animals and tracking their development over the course of ten days. Our system demonstrated its ability to measure a wide dynamic range fluorescent response from millimolar to picomolar concentrations in the same sample while measuring responses across visible wavelengths. These results demonstrate the power and flexibility of open-source hardware and software and how it can be integrated with customizable manufacturing to create low-cost scientific instruments with a wide range of applications. Our study provides a promising model for the development of low-cost instruments that can be used in both research and education.


Asunto(s)
Electrónica , Microscopía , Animales , Luz , Programas Informáticos , Tecnología
4.
ACS Sens ; 8(8): 3043-3050, 2023 08 25.
Artículo en Inglés | MEDLINE | ID: mdl-37540503

RESUMEN

Autofluorescence is one of the many challenges in bioimaging as it can mask the emission from fluorescent probes or markers, a limitation that can be overcome via upconversion. Herein, we have developed a nanosensor that uses triplet-triplet annihilation upconversion to optically report changes in the dissolved oxygen concentration. Using a sensitizer-annihilator dye pairing of platinum(II) octaethylporphyrin and 9,10-diphenylanthracene, we monitored the oxygen consumption (as a proxy for metabolic activity) over time in a biological system─Saccharomyces cerevisiae (brewing yeast). The nanosensor demonstrated good reversibility over multiple cycles and showed good signal and colloidal stability when tested over the course of 7 days, and it was sensitive to dissolved oxygen from 0.00 to 3.17 mg/L O2. Additionally, there was no signal overlap between the nanosensor emission and S. cerevisiae autofluorescence, thus underscoring the utility of upconversion as a facile and economical means of overcoming autofluorescence.


Asunto(s)
Colorantes Fluorescentes , Saccharomyces cerevisiae , Oxígeno
5.
ACS Sens ; 7(9): 2606-2614, 2022 09 23.
Artículo en Inglés | MEDLINE | ID: mdl-36053212

RESUMEN

Flash nanoprecipitation (FNP) is an efficient and scalable nanoparticle synthesis method that has not previously been applied to nanosensor fabrication. Current nanosensor fabrication methods have traditionally exhibited poor replicability and consistency resulting in high batch-to-batch variability, highlighting the need for a more tunable and efficient method such as FNP. We used FNP to fabricate nanosensors to sense oxygen based on an oxygen-sensitive dye and a reference dye, as a tool for measuring microbial metabolism. We used fluorescence spectroscopy to optimize nanosensor formulations, calibrate the nanosensors for oxygen concentration determination, and measure oxygen concentrations through oxygen-sensitive dye luminescence. FNP provides an effective platform for making sensors capable of responding to oxygen concentration in gas-bubbled solutions as well as in microbial environments. The environments we tested the sensors in arePseudomonas aeruginosa biofilms andSaccharomyces cerevisiae liquid cultures─both settings where oxygen concentration is highly dependent on microbial activity. With FNP now applied to nanosensor fabrication, future nanosensor applications can take advantage of improved product quality through better replicability and consistency while maintaining the original function of the nanosensor.


Asunto(s)
Nanopartículas , Oxígeno , Luminiscencia , Nanopartículas/química , Espectrometría de Fluorescencia
6.
Analyst ; 147(1): 120-129, 2021 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-34854441

RESUMEN

We developed a ratiometric oxygen-sensitive nanosensor and demonstrated application in monitoring metabolic oxygen consumption in microbial samples over time. Based on a near-infrared (NIR) emitting oxygen-quenched luminophore, platinum(II) octaethylporphine ketone (PtOEPK), along with a stable dioctadecyl dicarbocyanine reference dye (DiD), this nanosensor system provides an advantageous approach for overcoming imaging issues in biological systems, such as autofluorescence and optical scattering in the visible wavelength region. The dyes are encapsulated within a polymer-based nanoparticle matrix to maintain them at a constant ratio in biological samples, precluding the need for complex synthetic approaches. With this constant ratio of the two dyes, the nanosensor response can be measured as a ratio of their two signals, accounting for nanosensor concentration artifacts in measurements. The nanosensors are reversible, which enabled us to temporally monitor systems in which dissolved oxygen concentrations both increase and decrease. These sensors were applied for the monitoring of oxygen in samples of Saccharomyces cerevisiae (brewing yeast) in a 96-well optical fluorescence plate reader format over 60 h. By mixing the nanosensors directly into the sample well with the yeast, we were able to dynamically track metabolic activity changes over time due to varying cell concentration and exposure to an antimicrobial agent. This system could be a potential platform for high-throughput screening of various species or variants of microbes with unknown metabolic rates in response to external stimuli (antimicrobials, metabolites, etc.).


Asunto(s)
Técnicas Biosensibles , Nanotecnología , Oxígeno/análisis
7.
ACS Sens ; 6(12): 4408-4416, 2021 12 24.
Artículo en Inglés | MEDLINE | ID: mdl-34793121

RESUMEN

Traditional liquid phase extraction techniques that use optically responsive ligands provide benefits that enable cost-efficient and rapid measurements. However, these approaches have limitations in their excessive use of organic solvents and multistep procedures. Here, we developed a simple, nanoscale extraction approach by replacing the macroscopic organic phase with hydrophobic polymeric nanoparticles that are dispersed in an aqueous feed. The concentration of analytes in polymeric nanoparticle suspensions is governed by similar partition principles to liquid-liquid phase extraction techniques. By encasing optically responsive metal ligands inside polymeric nanoparticles, we introduce a one-step metal quantification assay based on traditional two-phase extraction methodologies. As an initial proof of concept, we encapsulated bathophenanthroline (BP) inside the particles to extract then quantify Fe2+ with colorimetry in a dissolved supplement tablet and creek water. These Fe2+ nanosensors are sensitive and selective and report out with fluorescence by adding a fluorophore (DiO) into the particle core. To show that this new rapid extraction assay is not exclusive to measuring Fe2+, we replaced BP with either 8-hydroxyquinoline or bathocuproine to measure Al3+ or Cu+, respectively, in water samples. Utilizing this nanoscale extraction approach will allow users to rapidly quantify metals of interest without the drawbacks of larger-scale phase extraction approaches while also allowing for the expansion of phase extraction methodologies into areas of biological research.


Asunto(s)
Extracción Líquido-Líquido , Nanopartículas , Interacciones Hidrofóbicas e Hidrofílicas , Solventes , Agua
8.
Nat Chem ; 13(5): 392-393, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33931749
9.
Biosensors (Basel) ; 10(9)2020 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-32927619

RESUMEN

Ionophore-based nanosensors (IBNS) are tools that enable quantification of analytes in complex chemical and biological systems. IBNS methodology is adopted from that of bulk optodes where an ion exchange event is converted to a change in optical output. While valuable, an important aspect for application is the ability to intentionally tune their size with simple approaches, and ensure that they contain compounds safe for application. Lipidots are a platform of size tunable lipid nanoemulsions with a hydrophobic lipid core typically used for imaging and drug delivery. Here, we present LipiSensors as size tunable IBNS by exploiting the Lipidot model as a hydrophobic structural support for the sensing moieties that are traditionally encased in plasticized PVC nanoparticles. The LipiSensors we demonstrate here are sensitive and selective for calcium, reversible, and have a lifetime of approximately one week. By changing the calcium sensing components inside the hydrophobic core of the LipiSensors to those sensitive for oxygen, they are also able to be used as ratiometric O2 sensitive nanosensors via a quenching-based mechanism. LipiSensors provide a versatile, general platform nanosensing with the ability to directly tune the size of the sensors while including biocompatible materials as the structural support by merging sensing approaches with the Lipidot platform.


Asunto(s)
Técnicas Biosensibles , Ionóforos/química , Lípidos/análisis , Materiales Biocompatibles , Calcio , Nanopartículas
10.
Analyst ; 145(11): 3996-4003, 2020 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-32342070

RESUMEN

In clinical environments, many serious antibiotic-resistant infections are caused by biofilm-forming species. This presents issues when attempting to determine antimicrobial dosing as traditional antibiotic susceptibility tests (ASTs) are typically designed around planktonic bacteria and thus offer information that is not relevant to the biofilm phenotype present in the patient. Even the popular Calgary biofilm device may provide inaccurate minimum biofilm inhibitory concentrations (MBICs) and can be time- and material-intensive. In this work, we present a method utilizing oxygen-sensitive nanosensor technology to monitor the oxygen consumption dynamics of living biofilms as they are exposed to antibiotics. We incorporated our nanosensors into biofilms grown from P. aeruginosa strains of varying sensitivity to traditional classes of antibiotics. Through measuring nanosensor response under antibiotic administration we determined the concentrations able to cease biofilm metabolism. This method provides information on the MBIC as well as kinetic response information in a manner that requires fewer materials and is more reflective of biofilm behavior than a traditional AST.


Asunto(s)
Antibacterianos/farmacología , Biopelículas/efectos de los fármacos , Oxígeno/análisis , Oxígeno/metabolismo , Pseudomonas aeruginosa/efectos de los fármacos , Pseudomonas aeruginosa/metabolismo , Colistina/farmacología , Relación Dosis-Respuesta a Droga , Pruebas de Sensibilidad Microbiana , Nanopartículas/química , Porfirinas/química , Pseudomonas aeruginosa/fisiología , Compuestos de Piridinio/química , Estirenos/química , Tobramicina/farmacología
11.
ACS Sens ; 5(2): 474-480, 2020 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-31912733

RESUMEN

Typical ionophore-based nanosensors use Nile blue derived indicators called chromoionophores, which must contend with strong background absorption, autofluorescence, and scattering in biological samples that limit their usefulness. Here, we demonstrate potassium-selective nanosensors that utilize triplet-triplet annihilation upconversion to minimize potential optical interference in biological media and a pH-sensitive quencher molecule to modulate the upconversion intensity in response to changes in analyte concentration. A triplet-triplet annihilation dye pair (platinum(II) octaethylporphyrin and 9,10-diphenylanthracene) was integrated into nanosensors containing an analyte binding ligand (ionophore), charge-balancing additive, and a pH indicator quencher. The nanosensor response to potassium was shown to be reversible and stable for 3 days. In addition, the nanosensors are selective against sodium, calcium, and magnesium (selectivity coefficients in log10 units of -2.2 for calcium, -2.0 for sodium, and -2.4 for magnesium), three interfering ions found in biological samples. The lack of signal overlap between the upconversion nanosensors and GFP, a common biological fluorescent indicator, is demonstrated in confocal microscope images of sensors embedded in a bacterial biofilm.


Asunto(s)
Nanotecnología/métodos , Potasio/química , Espectrometría de Fluorescencia/métodos , Humanos
12.
Appl Environ Microbiol ; 85(20)2019 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-31420335

RESUMEN

Bacterial biofilms can form persistent infections on wounds and implanted medical devices and are associated with many chronic diseases, such as cystic fibrosis. These infections are medically difficult to treat, as biofilms are more resistant to antibiotic attack than their planktonic counterparts. An understanding of the spatial and temporal variation in the metabolism of biofilms is a critical component toward improved biofilm treatments. To this end, we developed oxygen-sensitive luminescent nanosensors to measure three-dimensional (3D) oxygen gradients, an application of which is demonstrated here with Pseudomonas aeruginosa biofilms. The method was applied here and improves on traditional one-dimensional (1D) methods of measuring oxygen profiles by investigating the spatial and temporal variation of oxygen concentration when biofilms are challenged with antibiotic attack. We observed an increased oxygenation of biofilms that was consistent with cell death from comparisons with antibiotic kill curves for PAO1. Due to the spatial and temporal nature of our approach, we also identified spatial and temporal inhomogeneities in the biofilm metabolism that are consistent with previous observations. Clinical strains of P. aeruginosa subjected to similar interrogation showed variations in resistance to colistin and tobramycin, which are two antibiotics commonly used to treat P. aeruginosa infections in cystic fibrosis patients.IMPORTANCE Biofilm infections are more difficult to treat than planktonic infections for a variety of reasons, such as decreased antibiotic penetration. Their complex structure makes biofilms challenging to study without disruption. To address this limitation, we developed and demonstrated oxygen-sensitive luminescent nanosensors that can be incorporated into biofilms for studying oxygen penetration, distribution, and antibiotic efficacy-demonstrated here with our sensors monitoring antibiotic impacts on metabolism in biofilms formed from clinical isolates. The significance of our research is in demonstrating not only a nondisruptive method for imaging and measuring oxygen in biofilms but also that this nanoparticle-based sensing platform can be modified to measure many different ions and small molecule analytes.


Asunto(s)
Técnicas Bacteriológicas , Biopelículas , Mediciones Luminiscentes/métodos , Oxígeno/metabolismo , Infecciones por Pseudomonas/prevención & control , Pseudomonas aeruginosa/fisiología
13.
RSC Adv ; 9(56): 32821-32825, 2019 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-35529711

RESUMEN

Optical sensors have numerous positive attributes such as low invasiveness, miniaturizability, biocompatibility, and ease of signal transduction. Recently, there has been a strong research focus on using phosphorescent readout mechanisms, specifically from long-lifetime phosphorescent or 'persistent luminescence' particles, for in vitro and in vivo sensors. Persistent luminescence readouts can avoid cellular autofluorescence during biological monitoring, leading to an improved signal-to-noise ratio over a more traditional fluorescence readout. In this study, we show for the first time an ionophore-based optical bulk optode sensor that utilizes persistent luminescence microparticles for ion detection. To achieve this, we combined long-lifetime strontium aluminate-based 'glow-in-the-dark' microparticles with a non-fluorescent pH-responsive dye in a hydrophobic plasticized polymer membrane along with traditional ionophore-based optical sensor components to create a phosphorescent 'Glow Sensor'. The non-fluorescent pH indicator dye gates the strontium aluminate luminescence signal so that it decreases in magnitude with increasing sodium concentration. We characterized the Glow Sensor in terms of emission lifetime, dynamic range, response time, reversibility, selectivity, and stability.

14.
ACS Nano ; 9(2): 1692-8, 2015 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-25588028

RESUMEN

Personalized medicine could revolutionize how primary care physicians treat chronic disease and how researchers study fundamental biological questions. To realize this goal, we need to develop more robust, modular tools and imaging approaches for in vivo monitoring of analytes. In this report, we demonstrate that synthetic nanosensors can measure physiologic parameters with photoacoustic contrast, and we apply that platform to continuously track lithium levels in vivo. Photoacoustic imaging achieves imaging depths that are unattainable with fluorescence or multiphoton microscopy. We validated the photoacoustic results that illustrate the superior imaging depth and quality of photoacoustic imaging with optical measurements. This powerful combination of techniques will unlock the ability to measure analyte changes in deep tissue and will open up photoacoustic imaging as a diagnostic tool for continuous physiological tracking of a wide range of analytes.


Asunto(s)
Monitoreo de Drogas/métodos , Litio/uso terapéutico , Nanotecnología/métodos , Fenómenos Ópticos , Técnicas Fotoacústicas , Animales , Litio/metabolismo , Masculino , Ratones
15.
Analyst ; 139(20): 5230-8, 2014 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-25126649

RESUMEN

The advanced functionality of portable devices such as smart phones provides the necessary hardware to potentially perform complex diagnostic measurements in any setting. Recent research and development have utilized cameras and data acquisition properties of smart phones to create diagnostic approaches for a variety of diseases or pollutants. However, in concentration measurements, such as blood glucose, the performance of handheld diagnostic devices depends largely on the sensing mechanism. To expand measurements to multiple components, often necessary in medical tests, with a single diagnostic device, robust platform based sensors are needed. Here, we developed a suite of dual wavelength fluorescent sensors with response characteristics necessary to measure each component of a basic metabolic panel, a common clinical measurement. Furthermore, the response of these sensors could be measured with a simple optical setup to convert a smart phone into a fluorescence measurement instrument. This approach could be used as a mobile basic metabolic panel measurement system for point of care diagnostics.


Asunto(s)
Teléfono Celular/instrumentación , Metaboloma , Metabolómica/instrumentación , Espectrometría de Fluorescencia/instrumentación , Concentración de Iones de Hidrógeno , Microesferas , Sistemas de Atención de Punto
16.
Anal Chem ; 85(13): 6312-8, 2013 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-23767828

RESUMEN

Continuously tracking bioanalytes in vivo will enable clinicians and researchers to profile normal physiology and monitor diseased states. Current in vivo monitoring system designs are limited by invasive implantation procedures and biofouling, limiting the utility of these tools for obtaining physiologic data. In this work, we demonstrate the first success in optically tracking histamine levels in vivo using a modular, injectable sensing platform based on diamine oxidase and a phosphorescent oxygen nanosensor. Our new approach increases the range of measurable analytes by combining an enzymatic recognition element with a reversible nanosensor capable of measuring the effects of enzymatic activity. We use these enzyme nanosensors (EnzNS) to monitor the in vivo histamine dynamics as the concentration rapidly increases and decreases due to administration and clearance. The EnzNS system measured kinetics that match those reported from ex vivo measurements. This work establishes a modular approach to in vivo nanosensor design for measuring a broad range of potential target analytes. Simply replacing the recognition enzyme, or both the enzyme and nanosensor, can produce a new sensor system capable of measuring a wide range of specific analytical targets in vivo.


Asunto(s)
Técnicas Biosensibles/métodos , Histamina/análisis , Mediciones Luminiscentes/métodos , Nanotecnología/métodos , Animales , Masculino , Ratones , Ratones Desnudos
17.
Sensors (Basel) ; 12(9): 11922-32, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23112690

RESUMEN

In this communication we discuss the development of ionophore based nanosensors for the detection and monitoring of histamine levels in vivo. This approach is based on the use of an amine-reactive, broad spectrum ionophore which is capable of recognizing and binding to histamine. We pair this ionophore with our already established nanosensor platform, and demonstrate in vitro and in vivo monitoring of histamine levels. This approach enables capturing rapid kinetics of histamine after injection, which are more difficult to measure with standard approaches such as blood sampling, especially on small research models. The coupling together of in vivo nanosensors with ionophores such as nonactin provide a way to generate nanosensors for novel targets without the difficult process of designing and synthesizing novel ionophores.


Asunto(s)
Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Histamina/metabolismo , Animales , Ionóforos/metabolismo , Cinética , Nanopartículas
18.
Anal Chem ; 84(2): 1098-103, 2012 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-22145706

RESUMEN

The diagnosis, prevention, and treatment of many illnesses, including infectious and autoimmune diseases, would benefit from the ability to measure specific antibodies directly at the point of care. Thus motivated, we designed a wash-free, electrochemical method for the rapid, quantitative detection of specific antibodies directly in undiluted, unprocessed blood serum. Our approach employs short, contiguous polypeptide epitopes coupled to the distal end of an electrode-bound nucleic acid "scaffold" modified with a reporting methylene blue. The binding of the relevant antibody to the epitope reduces the efficiency with which the redox reporter approaches, and thus exchanges electrons with, the underlying sensor electrode, producing readily measurable change in current. To demonstrate the versatility of the approach, we fabricated a set of six such sensors, each aimed at the detection of a different monoclonal antibody. All six sensors are sensitive (subnanomolar detection limits), rapid (equilibration time constants ∼8 min), and specific (no appreciable cross reactivity with the targets of the other five). When deployed in a millimeter-scale, an 18-pixel array with each of the six sensors in triplicate support the simultaneous measurement of the concentrations of multiple antibodies in a single, submilliliter sample volume. The described sensor platform thus appears be a relatively general approach to the rapid and specific quantification of antibodies in clinical materials.


Asunto(s)
Anticuerpos Monoclonales/análisis , Anticuerpos Monoclonales/química , Técnicas Biosensibles , ADN/química , Electroquímica/instrumentación , Suero/química , Humanos
19.
J Diabetes Sci Technol ; 5(1): 68-75, 2011 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-21303627

RESUMEN

BACKGROUND: The advent of fluorescent nanosensors has enabled intracellular monitoring of several physiological analytes, which was previously not possible with molecular dyes or other invasive techniques. We have extended the capability of these sensors to include the detection of small molecules with the development of glucose-sensitive nano-optodes. Herein, we discuss the design and development of glucose-sensitive nano-optodes, which have been proven functional both in vitro and in vivo. METHODS: Throughout the design process, each of the sensor formulations was evaluated based on their response to changes in glucose levels. The percent change in signal, sensor reversibility, and the overall fluorescence intensity were the specific parameters used to assess each formulation. RESULTS: A hydrophobic boronic acid was selected that yielded a fully reversible fluorescence response to glucose in accordance with the sensor mechanism. The change in fluorescence signal in response to glucose was approximately 11%. The use of different additives or chromophores did not improve the response; however, modifications to the plasticized polymeric membrane extended sensor lifetime. CONCLUSIONS: Sensors were developed that yielded a dynamic response to glucose and through further modification of the components, sensor lifetime was improved. By following specific design criteria for the macrosensors, the sensors were miniaturized into nano-optodes that track changes in glucose levels in vivo.


Asunto(s)
Técnicas Biosensibles/instrumentación , Glucemia/análisis , Diabetes Mellitus/sangre , Técnicas de Diagnóstico Endocrino/instrumentación , Colorantes Fluorescentes , Técnicas Biosensibles/métodos , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/terapia , Relación Dosis-Respuesta a Droga , Electrodos , Diseño de Equipo , Humanos , Modelos Biológicos , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Nanopartículas , Plastificantes/química , Plastificantes/farmacología , Polímeros/química , Polímeros/farmacología
20.
Trends Mol Med ; 16(12): 584-93, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20869318

RESUMEN

Worldwide, diabetes is a rapidly growing problem that is managed at the individual level by monitoring and controlling blood glucose levels to minimize the negative effects of the disease. Because of limitations in diagnostic methods, significant research efforts are focused on developing improved methods to measure glucose. Nanotechnology has impacted these efforts by increasing the surface area of sensors, improving the catalytic properties of electrodes and providing nanoscale sensors. Here, we discuss developments in the past several years on both nanosensors that directly measure glucose and nanomaterials that improve glucose sensor function. Finally, we discuss challenges that must be overcome to apply these developments in the clinic.


Asunto(s)
Técnicas Biosensibles/métodos , Glucemia/análisis , Diabetes Mellitus/sangre , Nanoestructuras , Nanotecnología/métodos , Animales , Técnicas Biosensibles/instrumentación , Diabetes Mellitus/diagnóstico , Humanos , Nanotecnología/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...