Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
J Dent ; 143: 104877, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38316199

RESUMEN

OBJECTIVE: This randomized controlled clinical trial evaluated the whitening efficacy, tooth sensitivity (TS), and volunteers' satisfaction following the use of activated charcoal powder and toothpaste. METHODS: Fifty-six volunteers were randomly allocated into 4 groups (n = 14) according to a 14-day toothbrushing or whitening treatment with activated charcoal powder (ACPW), activated charcoal toothpaste (ACT), regular fluoridated toothpaste (RT), and 10 % carbamide peroxide (CP). Objective (ΔE00) and subjective (ΔSGU) color and whiteness index (ΔWID) changes were calculated. Patients self-reported the risk and intensity of TS using a visual analogue scale and the volunteer's satisfaction was determined by a questionnaire. Color assessments were analyzed by Kruskal-Wallis followed by Dwas-Steel-Crithlow-Fligner, and absolute TS risk and volunteer's satisfaction by Fisher exact test (p < 0.05). RESULTS: ACPW and ACT promoted similar effects in ΔE00, ΔSGU, and ΔWID to that observed for RT. No significant difference was found in terms of TS risk intensity. TS risk became high after 7 and 14 days, with higher TS prevalence in CP. Volunteers reported that ACPW exhibited the lowest ease-of-use, comfort, and whitening satisfaction among groups (p < 0.05). CONCLUSION: Activated charcoal-based products presented a minor and unsatisfactory whitening effect while CP resulted in optimal tooth whitening and the highest level of satisfaction among volunteers. Risk was higher from 7 days onwards and was more pronounced in the CP. CLINICAL RELEVANCE: Based on the whitening effect and patient satisfaction, this controlled-randomized clinical evidence supports that the use of activated charcoal-based products should be discouraged.


Asunto(s)
Sensibilidad de la Dentina , Blanqueamiento de Dientes , Humanos , Peróxido de Hidrógeno/uso terapéutico , Carbón Orgánico/uso terapéutico , Pastas de Dientes/uso terapéutico , Polvos , Método Simple Ciego , Blanqueamiento de Dientes/métodos , Peróxido de Carbamida , Sensibilidad de la Dentina/tratamiento farmacológico
2.
Braz. j. oral sci ; 23: e241938, 2024. ilus
Artículo en Inglés | LILACS, BBO | ID: biblio-1532506

RESUMEN

Aim: To evaluate changes in the surface roughness and morphology of a nanofilled composite following toothbrushing with a whitening (WT) or regular toothpaste (RT), alone or combined with 35% hydrogen peroxide bleaching (HP). Methods: Seventy disc-shaped nanofilled composite (Filtek Z350XT) specimens were randomly divided into groups (n=10): WT, RT, TB (without toothpaste ­ control) or the combinations WT/ HP, RT/HP, TB/HP and HP. All groups underwent toothbrushing simulation (60,000 cycles) and bleaching treatment (4 sessions). Mean surface roughness (Ra, µm) was measured before (T0) and after treatments (TB). Surface morphology was assessed by scanning electron microscopy (SEM) at TB. Mean Ra was analyzed using general mixed models and multiple comparisons by the Tukey-Kramer test (α=5%). Results: HP caused no surface roughness changes on the nanofilled composite after treatment (p>0.05). RT toothbrushing, combined or not with HP, increased the surface roughness (p<0.05). WT and WT/ HP protocols had no effect on the surface roughness of the composite (p>0.05). The nanofilled composite submitted to RT toothbrushing combined with HP (RT/HP) presented substantial surface alterations under SEM, showing deep depressions and round-shaped defects. Toothbrushing with RT combined with the bleaching agent increased exposure of the inorganic fillers. Conclusion: WT toothbrushing, regardless of HP combination, or the single HP protocol had no effect on the surface roughness of the nanofilled composite. However, RT combined with HP negatively affected surface roughness and presented the most noticeable surface changes among groups


Asunto(s)
Blanqueamiento de Dientes , Pastas de Dientes , Microscopía Electrónica de Rastreo , Resinas Compuestas , Peróxido de Hidrógeno
3.
Int J Prosthodont ; 36(4): 460-468, 2023 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-37699187

RESUMEN

PURPOSE: To evaluate the performance of fully crystallized zirconia-reinforced lithium silicate (Celtra Duo, ZLS-CD), partially crystallized zirconia-reinforced lithium silicate (Vita Suprinity, ZLS-VS), and partially sintered lithium disilicate-based (IPS e.max CAD, LD) glass-ceramics submitted to polishing, glazing, or no surface treatment after aging. MATERIAL AND METHODS: Samples of each glass-ceramic material were subjected to polishing with rubber cups (POL), glazing (GL), or no treatment (control: unpolished) and afterward aged with 18,000 thermal cycles (5.C to 55.C). The average roughness, 2D and 3D morphology, contact angle, multispecies biofilm formation (Streptococcus mutans and Candida albicans), and mechanical strength were evaluated with atomic force microscopy (AFM, n = 5), sessile-drop goniometry (n = 5), spectrophotometry (n = 5), and the flexural strength test (n = 10), respectively. Data were analyzed using two-way ANOVA and Tukey test (α = 5%). RESULTS: POL produced lower surface roughness than GL, and ZLS-CD presented higher roughness than LD (P < .05). Surfaces without polishing displayed higher roughness than the POL group (P < .001), greater contact angle (P < .001), and significant morphologic changes, regardless of the glass-ceramic material. Irrespective of the treatment, the contact angle was higher in the ZLS-CD group, and regardless of the material, there was higher biofilm formation and lower flexural strength of the unpolished compared to the POL or GL ceramics. CONCLUSIONS: POL promoted lower roughness and minor morphologic surface alterations, but biofilm formation and flexural strength were similar to the GL group. In general, ZLS-CD and ZLS-VS showed more similar behavior than LD, which makes ZLS glass-ceramic a good option for indirect restorations.


Asunto(s)
Cerámica , Litio , Silicatos , Biopelículas
4.
J Mech Behav Biomed Mater ; 144: 105961, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37320893

RESUMEN

AIMS: To evaluate the influence of the type of preparation and mechanical cycling on the fracture load and failure mode of semi-direct posterior resin composite restorations. METHODS: In total, 70 healthy third molars were used; 10 belonging to the control group (C - unprepared teeth) and 60 teeth prepared and restored with nanoparticle resin composite, divided into 3 groups (n = 20): O - exclusively occlusal preparation (Table Top); OV - occlusal preparation with buccal extension (Veneerlay); OVP - Occlusal preparation with chamfer on the proximal and buccal-lingual/palatal surfaces (Overlay). The preparations were performed with diamond burs with a thickness of 1 mm. The restorations were made with nanoparticulate resin composite (Filtek Z350 XT) and subsequently received additional polymerization (thermoprocessing). Cementation was performed with the use of universal adhesive system (Single Bond Universal) on dental substrate and dual resin cement (RelyX ARC). Half of the teeth in each group (n = 10) were submitted to mechanical cycling, simulating 6 months of clinical service (5 × 105 fatigue cycles), under dynamic loading of 130 N, at a frequency of 2Hz. Fracture load tests were performed in a universal testing machine with a 200 kgf load cell. Failure mode was classified using scores. Generalized linear models and Fisher Exact tests were applied to the data (significance level of 5%). RESULTS: There were no significant differences between the types of preparation (p = 0.9435), or relative to cycling (p = 0.3764). The Fisher Exact Test showed a significant association between the groups and the type of failure (p = 0.0006), with preparations O (with cycling) and OVP (with and without cycling) exhibiting most failures with restoration fractures without involvement of the dental remnant. CONCLUSIONS: Semi-direct restorations showed resistance to fracture load similar to that of healthy teeth and were capable of withstanding functional masticatory loads. The type of preparation influenced the failure mode of teeth. The Table Top and Overlay types of preparations were those had fewer catastrophic failures, suggesting that since they are more conservative preparations, they made it possible for the tooth to receive a new restorative procedure in the future in cases of failures.


Asunto(s)
Resinas Compuestas , Cementos de Resina , Ensayo de Materiales , Resinas Compuestas/química , Cementos de Resina/química , Diseño Asistido por Computadora , Análisis del Estrés Dental , Fracaso de la Restauración Dental , Restauración Dental Permanente , Porcelana Dental
5.
J Mech Behav Biomed Mater ; 143: 105919, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37279637

RESUMEN

This study developed an experimental flowable composite incorporated with niobium pentoxide (Nb2O5) combined or not with titanium dioxide co-doped with fluorine and nitrogen (NF_TiO2) and evaluated the mechanical and antibacterial properties. The experimental flowable composite (TEGDMA + BisGMA 1:1 + 60%wt - inorganic filler - borosilicate 0.7 µm) was formulated according to the type and concentration of Nb2O5 and NF_TiO2 (0.5, 1, 1.5 and 2 wt%) or NF_TiO2 + Nb2O5 (0.25, 0.5, 0.75 and 1 wt% - 1:1). The control groups were formed by the experimental composite without the incorporation of Nb2O5 and/or NF_TiO2 (GC-E) and by a commercial flowable composite (GC). The characterization of the surface of the composite and its particles was carried out using scanning electron microscopy (SEM) and energy dispersive x-rays (EDX). Specimens were manufactured and subjected to mechanical tests of flexural strength (FS) (n = 12), flexural modulus (FM) (n = 12), roughness (Ra) (n = 10), microhardness (n = 10), and contact angle (n = 10); and, to evaluate the antibacterial activity, they were submitted to tests of biofilm formation against S. mutans (CFU/mL) (n = 5), biofilm biomass by dry weight (n = 5) and confocal laser microscopy (%LIVE/DEAD) (n = 5). Data were submitted to one-way ANOVA and Tukey's post-hoc and, those that were not homoscedastic, but with normality, were submitted to Welch's ANOVA and Games-Howell's post-hoc. Dunnet's test was used to compare the controls with the other experimental groups (α = 5). The Nb2O5 particles had an average size of 32.4 µm and the nanoparticles (NPs) of NF_TiO2, 10 nm. EDX analysis identified isolated peaks of N, F, Ti, and Nb confirming the presence of these particles in the resin matrix. The 1.5% NF_TiO2 group had a higher FS and FM than the controls (p < 0.05). GC showed higher microhardness between groups (p < 0.05). There was no difference between the experimental groups regarding contact angle and roughness (p > 0.05), except for GC, which had the highest Ra values and the lowest contact angle between groups (p < 0.05). Composites containing 0.5%, 1%, 1.5%, and 2% Nb2O5, 1%, 1.5%, and 2% NF_TiO2 and 2% Nb2O5 + NF_TiO2 showed lower biofilm formation (p < 0.05), lower total biofilm biomass (p < 0.05), and a higher percentage of dead cells (44%, 52%, 52%, 79%, 42% 43%, 62%, 65%, respectively) than GC and GC-E (5% and 1%, respectively). It is concluded that the incorporation of 1.5% NF_TiO2 promoted a greater FS and FM among the experimental composites and that the addition of Nb2O5 particles (0.5%, 1%, 1.5%, and 2%), NF_TiO2 (1%, 1.5% and 2%) and the combination Nb2O5 + NF_TiO2 (2%) showed significant antibacterial effects.


Asunto(s)
Nanopartículas , Niobio , Ensayo de Materiales , Resinas Compuestas , Antibacterianos/farmacología , Propiedades de Superficie
6.
Am J Dent ; 36(3): 136-142, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37364191

RESUMEN

PURPOSE: To determine caries inhibition potential of conventional and bulk-fill bioactive composites around restorations. METHODS: Enamel and dentin blocks were prepared using a diamond saw under water irrigation, finished (SiC, 600- and 800-grit) and polished (SiC 1,200, final polish= 0.2 µm). Blocks were then selected through enamel surface microhardness, and enamel and dentin standard cavities were restored (n=10/group) with conventional bioactive composite (Beautifil II, BTF), bulk-fill bioactive composite (Activa BioACTIVE, ACT), glass-ionomer cement (Ionofil Plus, ION), conventional composite (GrandioSO, GSO), and bulk-fill composite (Admira Fusion X-TRA, ADM). Afterwards, the blocks were subjected to pH cycling: 4 hours in demineralization and 20 hours in remineralization solutions for 7 days, before being cut in the middle. One half was used to calculate the carious lesion area (ΔS) using values obtained by cross-sectional microhardness (CSMH) testing. The other half was submitted to polarized light microscopy (PLM) and scanning electron microscopy (SEM). The % of internal gap formation (GAP) of restorations' replicas were analyzed under SEM. Data were analyzed by ANOVA and Tukey test (α= 5%). RESULTS: In terms of CSMH, ION group exhibited the lowest ΔS values, with no significant difference to ADM. The composites BTF and ACT were similar to each other (P< 0.05) and to their negative controls (GSO and ADM), respectively. ION showed lower caries formation under PLM, whereas the GSO group presented a greater demineralized area. ION presented the highest % of internal GAP formation. Bioactive composites (BTF and ACT) were similar to their corresponding conventional ones (GSO and ADM) in terms of GAP formation. CLINICAL SIGNIFICANCE: The glass-ionomer cement was more effective in inhibiting the formation of caries lesions around restorations. Because of the glass-ionomer cement's limited application in high load-bearing areas, the conventional bioactive composite would be a promising clinical choice.


Asunto(s)
Resinas Compuestas , Caries Dental , Humanos , Susceptibilidad a Caries Dentarias , Caries Dental/prevención & control , Cementos de Ionómero Vítreo/farmacología , Esmalte Dental , Restauración Dental Permanente/efectos adversos , Ensayo de Materiales
7.
Clin Oral Investig ; 27(8): 4827-4841, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37369816

RESUMEN

OBJECTIVES: The objective of the study is to evaluate the bleaching potential of 6% hydrogen peroxide (6% HP) gels containing NF_TiO2 or Nb2O5 irradiated with a violet LED light and the effects on enamel mineral content and surface morphology. METHODS: Particles were synthesized, and experimental gels were chemically analyzed by preliminary and accelerated stability tests, pH, and HP decomposition rate. Bovine enamel blocks were treated with 6% HP gels containing (n = 10): 5% NF_TiO2, 5% Nb2O5, 2.5% NF_TiO2 + 2.5% Nb2O5 or without particles (6% HP), irradiated or not with LED, and the control was treated with 35% HP. Color (∆E00) and whitening index (∆WID) variations, surface microhardness (SH), average roughness (∆Ra), Ca-P concentration (EDS), and enamel morphology (SEM) were assessed. Bleaching was performed in 3 sessions of 30 min and 7-day intervals. Data were submitted to two- (pH, decomposition rate, ∆E00, and ∆WID) or three-way ANOVA and Bonferroni (SH), Kruskal-Wallis (∆Ra), and Dunnet tests (α = 0.05). RESULTS: No changes in the gel's color, odor, or translucency were observed. The pH (6 to 6.5) remained stable over time, and light irradiation boosted the HP decomposition rate. NF_TiO2 and Nb2O5-containing gels displayed higher ∆E00 and ΔWID when light-irradiated (p < 0.05). Nb2O5 and Nb2O5 + NF_TiO2 decreased enamel SH (p < 0.05), but no SH changes were found among groups (p > 0.05). No differences among groups were noted in ∆Ra, Ca-P content, and enamel morphology after treatments (p > 0.05). CONCLUSION: Experimental light-irradiated 6% HP gels containing NF_TiO2 or Nb2O5 were chemically stable and exhibited bleaching potential comparable with 35% HP. CLINICAL RELEVANCE: Low-concentrated HP gels containing NF_TiO2 or Nb2O5 and light-irradiated stand as a possible alternative to in-office bleaching.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Animales , Bovinos , Blanqueadores Dentales/farmacología , Peróxido de Hidrógeno/farmacología , Ácido Hipocloroso , Geles
8.
Photodiagnosis Photodyn Ther ; 42: 103568, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37059164

RESUMEN

PURPOSE: This study evaluated enamel with early-stage erosion/abrasion following bleaching with 20% and 45% carbamide peroxide (CP) gels containing fluoride (F) and irradiated with violet LED (LED). METHODS: Enamel blocks were immersed in 1% citric acid (5 min) and artificial saliva (120 min) three times to produce early-stage enamel erosion. Simulated toothbrushing was performed only after the first saliva immersion, to provoke enamel abrasion. The erosive/abraded enamel samples were submitted to (n=10): LED/CP20, CP20, LED/CP20_F, CP20_F, LED/CP45, CP45, LED/CP45_F, CP45_F, LED, and control (without treatment). The pH of the gels was assessed, and color (ΔE00) and whiteness index (ΔWID) changes were calculated after cycling (T1), and 7 days from bleaching (T2). Enamel surface roughness average (Ra) and Knoop microhardness (kg/mm2, %SHR) were evaluated at baseline (T0) at T1 and T2. Scanning electron microscopy evaluated the enamel surface morphology at T2. RESULTS: The gels' pH was neutral and CP20 and CP45 exhibited no differences in ΔE00 and ΔWID (p>0.05) but LED increased these parameters for CP20_F and CP45. Erosion/abrasion significantly decreased mean kg/mm2, and the LED group was the only one not increasing microhardness after bleaching (p>0.05). None of the groups fully recovered the initial microhardness. All groups exhibited %SHR similar to the control (p>0.05) and the increase in Ra was detected only after erosion/abrasion. CP20_F groups exhibited a more preserved enamel morphology. CONCLUSION: Light irradiation combined with low-concentrated CP gel promoted a bleaching effect comparable to the high-concentrated CP. The bleaching protocols did not adversely impact the surface of early-stage eroded/abraded enamel.


Asunto(s)
Fotoquimioterapia , Blanqueamiento de Dientes , Peróxido de Carbamida , Peróxidos , Fluoruros , Urea , Blanqueamiento de Dientes/efectos adversos , Blanqueamiento de Dientes/métodos , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes , Ácido Hipocloroso , Geles
9.
Dent Mater ; 39(5): 469-477, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36934036

RESUMEN

OBJECTIVE: In this study a dentistry nanocomposite with prolonged antibacterial activity using silica nanoparticles (SNPs) loaded with chlorhexidine (CHX) was developed. METHODS: SNPs were coated with the Layer-by-Layer technique. Dental composites were prepared with organic matrix of BisGMA/TEGDMA and SNPs with or without CHX (0, 10, 20 or 30% w/w). The physicochemical properties of the developed material were evaluated and agar diffusion method was used to test the antibacterial. In addition, the biofilm inhibitory activity of the composites was evaluated against S. mutans. RESULTS: SNPs were rounded with diameters about 50 nm, the organic load increased with increasing deposited layers. Material samples with SNPs loaded with CHX (CHX-SNPs) showed the highest values of post-gel volumetric shrinkage, that ranged from 0.3% to 0.81%. Samples containing CHX-SNPs 30% w/w showed the highest values of flexural strength and modulus of elasticity. Only samples containing SNPs-CHX showed growth inhibition against S. mutans, S. mitis and S. gordonii in a concentration-dependent manner. The composites with CHX-SNPs reduced the biofilm formation of S. mutans biofilm at 24 h and 72 h. SIGNIFICANCE: The nanoparticle studied acted as fillers and did not interfere with the evaluated physicochemical properties while providing antimicrobial activity against streptococci. Therefore, this initial study is a step forward to the synthesis of experimental composites with improved performance using CHX-SNPs.


Asunto(s)
Clorhexidina , Nanopartículas , Clorhexidina/farmacología , Clorhexidina/química , Dióxido de Silicio/farmacología , Dióxido de Silicio/química , Antibacterianos/farmacología , Antibacterianos/química , Nanopartículas/química , Streptococcus mutans
10.
J Mech Behav Biomed Mater ; 138: 105606, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36525873

RESUMEN

OBJECTIVE: To evaluate the effects of simulated gastric acid erosion combined with mechanical toothbrushing abrasion on the mechanical properties, surface topography, and biofilm adhesion of different CAD/CAM materials. MATERIAL AND METHODS: Specimens of zirconia-reinforced lithium silicate glass-ceramic (ZLS), polymer-infiltrated ceramic network (PICN), feldspathic glass-ceramic (FE), and two nanoceramic resins (RK, RG), were submitted to the following challenges: erosion (E), abrasion (A), erosion combined with abrasion (E + A), or remained untreated (control - C). After challenges, flexural strength was evaluated, while microhardness (KHN) and surface roughness (Ra) were tested before and after treatments. The biofilm adhesion (Streptococcus mutans ATCC 700610, Streptococcus sanguinis ATCC 10556 e Candida albicans MYA 2876) was determined by the counting of colonies forming units per milliliters (UFC/mL) after erosive and abrasive challenges. RESULTS: FE showed the lowest flexural strengths, while ZLS and RG exhibited the highest, while PICN and RK, had intermediate values. PICN, ZLS, and FE showed lower microhardness after E and E + A challenges than polymer-based materials (RG and RK). FE surface roughness increased after E and E + A challenges and after A and E + A challenges for RK. Biofilm formation after erosive/abrasive challenges was higher on ZLS than FE, RK, and RG, but no different than PICN. RK and RG exhibited the lowest biofilm formation among the groups. Furthermore, E + A challenges held significant changes in the surface of the materials, which were more severe on the surface of glass ceramics and hybrid materials. CONCLUSION: Erosive challenges combined with abrasion negatively influenced the mechanical properties and surface topography of most CAD/CAM materials and increased the biofilm adhesion on ZLS. Besides, the severity of the damage is related to the type and composition of each material.


Asunto(s)
Ácido Gástrico , Cepillado Dental , Ensayo de Materiales , Diseño Asistido por Computadora , Cerámica , Polímeros , Propiedades de Superficie , Porcelana Dental
11.
Photodiagnosis Photodyn Ther ; 41: 103254, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36572111

RESUMEN

BACKGROUND: The purpose of this study was: 1) to analyze the physical-chemical properties of hydrogen peroxide (HP) agents at 7.5% (HP7) and 35% (HP35), and the association with or without TiO2 nanotubes; 2) to evaluate dental bleaching effectiveness by using HP7 and HP35 together with or without TiO2 nanotubes, and applied with or without violet LED (VL). METHODOLOGY: 80 bovine incisors were treated according to groups (n = 10): HP35; HP35 + VL; HP35T (HP35 + TiO2); HP35T + VL; HP7; HP7 + VL; HP7T (HP7 + TiO2); HP7T + VL. Bleaching effectiveness was measured at 4 time points according to the Vita Classical, CIEL*a*b*, CIEDE2000, and WID parameters. HP35, HP35T, HP7, and HP7T were evaluated for mass change, pH, mean particle size (P), polydispersity (PDI), and zeta potential (ZP), over 6 months of storage. RESULTS: The pH of HP35 thickener was higher when associated to TiO2. At baseline, both of the bleaching gels containing TiO2 had lower P, PDI, and PZ (p < 0.05). All groups showed a significant decrease in Vita Classical color scores (p = 0.0037). There was a higher L* value, and lower b* values for HP7 when associated to VL after the 3rd session. (p < 0.05). HP35T showed higher color change (ΔEab, ΔE00), and lower a* value in the presence of VL (p < 0.05). ΔWID presented lower values for both gels, when TiO2 was incorporated (p ≤ 0.05). CONCLUSION: The incorporation of TiO2 to the bleaching gel showed good stability with minimal variations in physical-chemical properties. The color change in HP35 was more effective than in HP7, but the VL boosted the bleaching effectiveness of HP7, whereas TiO2 did not increase bleaching effectiveness.


Asunto(s)
Fotoquimioterapia , Blanqueadores Dentales , Blanqueamiento de Dientes , Animales , Bovinos , Peróxido de Hidrógeno , Blanqueadores Dentales/farmacología , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes , Geles , Ácido Hipocloroso , Color
12.
Braz. j. oral sci ; 22: e238082, Jan.-Dec. 2023. tab
Artículo en Inglés | LILACS, BBO | ID: biblio-1393422

RESUMEN

Aim: To determine if the artificial staining with black tea (BT) influences the enamel microhardness before in-office bleaching and if BT staining is necessary to evaluate the efficacy of bleaching with 35% hydrogen peroxide Methods: Enamel/dentin blocks were randomized into groups according to the staining protocol (n=5/group): (CO) control ­ maintained in artificial saliva solution (AS); (BT4) immersed in black tea solution for 4 h; (BT24) immersed in black tea solution for 24 h. After the staining protocols, all specimens were kept in AS for one week, followed by bleaching (three sessions of HP application for 40 min). Knoop surface microhardness (kgF/mm2) was determined at baseline (T0), after staining (T1), after 7 days of storage in AS (T2), and after bleaching (T3). The color (∆E00) and coordinate changes (∆L, ∆a, ∆b) were measured using a digital spectrophotometer at T0 and T3. Data were submitted to one-way (∆E00, ∆L, ∆a, ∆b) or two-way ANOVA repeated measures (kgF/mm2) and Tukey's test (a=5%). Results: The staining protocols (BT4 and BT24) promoted significantly lower microhardness (T1 and T2, p<0.05) than CO, whereas CO was the only group to maintain microhardness values over time. Bleaching promoted perceptible ∆E00 without a significant difference among the groups regardless of the staining protocol (p=0.122). CO and BT4 showed no differences in terms of ∆L and ∆a (p>0.05), but BT4 displayed a higher ∆b than CO. Conclusion:The artificial staining with BT negatively affected the enamel surface microhardness and was not essential to evaluate the efficacy of 35% hydrogen peroxide bleaching


Asunto(s)
Coloración y Etiquetado , Té/efectos adversos , Blanqueamiento de Dientes , Color , Esmalte Dental , Blanqueadores , Pruebas de Dureza , Peróxido de Hidrógeno
13.
Braz. j. oral sci ; 22: e239079, Jan.-Dec. 2023. ilus
Artículo en Inglés | LILACS, BBO | ID: biblio-1413365

RESUMEN

Aim: To evaluate the marginal fit of protocol bars milled from digital models obtained by conventional molding followed by bench scanning or digital molding with an intraoral scanner. Methods: Four morse-cone implants and the mini-pillars were installed in a 3D printed mandible model (master model). Digital models of the master model were obtained by (n=10): (Group A - Conventional) conventional (analog) molding of the master model followed by bench scanning or (Group B - Digital) molding of the master model with an intraoral scanner. All-on-four protocol bars were designed and milled from the digital models for both groups and screwed into the master model. Scanning electron microscopy (SEM) images from the distal, central, and mesial regions of each implant were obtained and the implant-protocol bar marginal fit was measured in an image software (Image J). The mean misfit of each region was analyzed by two-factor ANOVA, Tukey test, and Student's t-test (0,05 = 0.05). Results: The digital approach (B) showed higher misadaptation than the conventional approach (A, p < 0.05), regardless of the region evaluated. In group A, the central region showed higher maladjustment than the mesial region (p<0.05), however, there were no differences among regions of group B (p>0.05). Conclusion: The conventional method of acquiring digital models using the bench scanner produced bars for the All-On-Four protocol with better marginal fit than the digital models obtained with an intraoral scanner


Asunto(s)
Microscopía Electrónica de Rastreo , Implantes Dentales , Diseño Asistido por Computadora
14.
Prim Dent J ; 11(4): 78-85, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36533364

RESUMEN

The influence of different surface treatments and ageing on the shear bond strength (SBS) of computer-aided design/computer-aided manufacturing (CAD/CAM) materials is still contentious. Therefore, this study evaluated the effect of surface treatments and ageing on the SBS of resin cement to polymer-infiltrated ceramic network (PICN) and zirconia-reinforced lithium silicate (ZLS) CAD/CAM materials. Specimens of PICN (n=10) and ZLS (n=10) were submitted to four surface treatment groups: 1) 5% hydrofluoric acid etching (HF) + silanisation (SI); 2) Air abrasion (AB)+HF+SI; 3) HF + universal adhesive (UA); 4) AB+HF+SI+UA. The treated specimens were bonded with resin cement cylinders and tested in SBS after 24 h and one year of water storage. Data were assessed by "analysis of variance" (ANOVA) and Tukey test (α=0.05) and failure modes were classified. No significant differences were observed among treatments at each evaluation time (p>0.05). SBS decreased after one year of storage, except for PICN treated with HF+UA (p=0.068). Air-abraded groups displayed a lower SBS reduction for ZLS. PICN and ZLS exhibited predominantly adhesive and mixed failures, but at one year, PICN cohesive failures increased. In conclusion, HF+UA is an effective surface treatment for PICN, while the combination AB+HF+SI+UA was more appropriate for ZLS. The water storage for one year reduced the SBS for most groups.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Humanos , Cementos de Resina/uso terapéutico , Abrasión Dental por Aire , Ensayo de Materiales , Propiedades de Superficie , Cerámica/uso terapéutico , Cerámica/química , Diseño Asistido por Computadora , Agua , Porcelana Dental/química
15.
Nanomaterials (Basel) ; 12(17)2022 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-36080033

RESUMEN

The present study reports on the development and testing of novel bleaching agents containing co-doped metaloxide nanoparticles (NP; 0%, 5%, 10% v/w) and hydrogen peroxide (HP, 0%, 6%, 15%, and 35%). Bovine blocks (n = 200, A = 36 mm2) were obtained and randomly distributed into experimental groups (n = 10/group). NPs were incorporated into gels before bleaching (3 sessions, 7 days apart, 30 min/session, irradiated with violet light-LT). Color changes (ΔE00, ΔWID), mineral content (CO32−, PO43−), and topography were assessed (spectrophotometer, ATR-FTIR, and AFM) before and after bleaching procedures (14 days). Metabolic status and three-dimensional components of non-disrupted Streptococcus mutans biofilms were investigated using a multimode reader and confocal microscopy. The results indicate that ΔE00 and ΔWID significantly increased with NPs' concentrations and LT. The enamel's mineral ratio was adversely impacted by HP, but alterations were less pronounced when using NP-containing gels. The enamel's topography was not damaged by the bleaching protocols tested. The bioluminescence results show that bleaching protocols do not render latent antibacterial properties to enamel, and the confocal microscopy results demonstrate that the 3-dimensional distribution of the components was affected by the protocols. The proposed nanotechnology improved the bleaching efficacy of experimental materials independent of hydrogen peroxide or irradiation and did not adversely impact the enamel's surface properties or its chemical content.

16.
Gels ; 8(3)2022 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-35323291

RESUMEN

This in vitro study evaluated color change, mineral content, and morphology of enamel, pH and cytotoxicity of experimental bleaching agents containing 35% hydrogen peroxide (HP), titanium tetrafluoride (TiF4), Natrosol, and Chemygel. Sixty enamel/dentin blocks were randomly treated with (n = 10) HP; HP+Natrosol+Chemygel with different TiF4 concentrations: 0.05 g HPT0.5, 0.1 g HPT1, 0.2 g HPT2, 0.3 g HPT3, 0.4 g HPT4. Bleaching was performed in three sessions (3 × 15 min application). Color change (CIELab-ΔEab, CIEDE2000-ΔE00, ΔWID) and Knoop microhardness (KHN) were evaluated. Enamel morphology and composition were observed under scanning electron microscopy and energy-dispersive spectrometry (EDS), respectively. Cell viability of keratinocyte cells was evaluated using MTT assay. Data were analyzed by one-way ANOVA and LSD and Tukey tests, and two-way repeated measures ANOVA and Bonferroni (α = 5%). The pH and EDS were analyzed descriptively. Lightness-L* increased, and a* and b* parameters decreased, except for HPT3 and HPT4 (b*). HPT0.5, HPT1, and HPT2 exhibited ΔEab and ΔWID similar to HP. ΔE00 did not present statistical difference. HP, HPT0.5, and HPT1 promoted higher KHN. HPT0.5 exhibited no changes on enamel surface. Keratinocyte cells were viable when treated with T0.5, and weak viable for T1. Experimental agents exhibited acidic pH and Ti elements. HPT0.5 exhibited bleaching efficacy, maintained KHN without enamel alterations, and did not increase cytotoxicity.

17.
J Evid Based Dent Pract ; 22(1): 101682, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35219459

RESUMEN

OBJECTIVE: This systematic review and meta-analyses aimed to evaluate the potential protective effect of titanium tetrafluoride (TiF4) compound compared to sodium fluoride (NaF) on eroded enamel or dentin. METHODS: Two independent reviewers searched PubMed, Scopus, Web of Science, LILACS, Cochrane, EMBASE, and Open gray Literature up to June 2020. MeSH terms, supplementary concepts, synonyms, and free terms were applied based on PICOS strategy (P- population: eroded enamel or dentin; I- intervention: eroded teeth treated with solution or varnish of TiF4; C- comparison: eroded teeth treated with a solution or varnish of NaF; O- outcome: mineral loss measurement; S- study design: in vitro studies). Seven distinct parameters evaluated the risk of bias, and all studies were submitted to 4 meta-analyses (first and second meta-analyses related to enamel loss treated with fluoride solution or varnish, respectively; third and fourth meta-analyses related to dentin loss treated with fluoride solution or varnish, respectively). A sensitivity test was performed by the RevMan software, based on standard mean difference calculation (P < .05). RESULTS: A total of 10,260 studies were retrieved, from which 22 studies were included in systematic review through eligibility criteria, of which 1 study was classified as low risk of bias, 19 as medium, and 3 as high. Seventeen studies were included in 4 different meta-analyses, presenting considerable overall heterogeneity (I2 = 95; 92; 95; and 93%, respectively) with statistical significance for TiF4 on the first meta-analysis, and no statistical significance for second, third, and fourth meta-analyses. CONCLUSIONS: Titanium tetrafluoride compound delivered as solution provided significant effective protection for erosion lesions on the enamel surface compared to sodium fluoride. However, when TiF4 or NaF were applied on enamel or dentin surfaces as varnish, both provided the same effective protection, based on in vitro studies with considerable heterogeneity.


Asunto(s)
Fluoruros , Erosión de los Dientes , Cariostáticos/farmacología , Cariostáticos/uso terapéutico , Fluoruros/farmacología , Humanos , Fluoruro de Sodio/farmacología , Titanio , Erosión de los Dientes/prevención & control
18.
Clin Oral Investig ; 26(5): 3899-3910, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35006294

RESUMEN

OBJECTIVES: This study characterized a violet LED light (V-LED; bright max whitening) tooth whitening device and evaluated its efficacy on stained enamel compared to hydrogen peroxide (HP). MATERIALS AND METHODS: Characterization of the V-LED beam profile was performed using a laser beam-profiler. The irradiance was measured throughout an exposure cycle at 0- and 8-mm distances using an integrating sphere and a spectral radiometer. Bovine enamel/dentin blocks stained with black tea (BT), cigarette smoke (CS), or without staining (CONT) were subjected to V-LED or 40% HP (n = 10/group). Color parameters (ΔL, Δa, Δb, and ΔE00) were measured using a digital spectrophotometer. Light transmission was estimated through 1-mm-thick bovine enamel slices (n = 5). ΔL, Δb, ΔE00, and irradiance were analyzed by two-way ANOVAs and Tukey's tests, Δa by Kruskal-Wallis and Mann-Whitney tests, and light transmission by t-test (α = 5%). RESULTS: Heterogeneous beam distribution was observed for the emitting V-LED chips. After 20 sequential exposures, irradiance levels were reduced 25-50%, regardless of the distance from V-LED. Localized irradiance values were statistically different between beam locations and different distances from the target. V-LED produced lower ΔE00, ΔL, Δa, and Δb values than HP for CONT and BT, with no differences for CS. Light transmittance decreased approximately 98% through 1-mm thick enamel. CONCLUSIONS: V-LED irradiance was heterogeneous and decreased throughout the exposure cycles and was also greatly reduced with increasing tip distance. V-LED produced a significantly lower whitening effect on BT and control teeth. CLINICAL RELEVANCE: This study contributes to the knowledge of V-LED and its clinical use.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Animales , Bovinos , Color , Esmalte Dental , Peróxido de Hidrógeno , Luz , , Blanqueadores Dentales/farmacología
19.
J Esthet Restor Dent ; 34(3): 490-502, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34623017

RESUMEN

OBJECTIVE: To answer the question: "Does the peroxide gel application regimen (single application vs. renewal) influence the efficacy and the tooth sensitivity outcomes of in-office tooth bleaching?" METHODS: The search was done in Pubmed, Cochrane, LILACS, Scopus, Web of Science, and EMBASE in February 2021 (updated in July 2021). Randomized clinical trials (RCT) comparing the single application vs. the renewal protocols of HP were included. The meta-analyses were performed for the objective (ΔEab ), subjective (ΔSGU) color changes, and absolute risk of tooth sensitivity (TS). Heterogeneity was evaluated using Q test (I2 ). Cochrane Collaboration tool assessed the risk of bias (RoB). The GRADE evaluated the certainty of evidence. RESULTS: Five RCT studies remained. Two studies showed high RoB, and three presented some concerns. No significant differences were observed between the protocols in terms of the ΔEab , ΔSGU, and TS. ΔEab exhibited substantial heterogeneity (I2  = 87%), while ΔSGU (I2  = 60%) and the TS (I2  = 62%) presented a moderate one. The certainty of evidence was considered low or very low, depending on the variable response and the evaluation time. CONCLUSION: The application regimen (single vs. renewal of HP) did not impact color change or the absolute risk of TS. CLINICAL SIGNIFICANCE: The renewal of bleaching gel during the in-office appointment may not be necessary. However, there is at least a low certainty of evidence. Because of this, further randomized clinical trials with appropriate methodology on this topic are encouraged.


Asunto(s)
Sensibilidad de la Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Peróxido de Hidrógeno , Peróxidos , Blanqueamiento de Dientes/métodos , Resultado del Tratamiento
20.
Clin Oral Investig ; 26(1): 837-847, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34269885

RESUMEN

OBJECTIVES: To evaluate the long-term outcomes of in-office bleaching with violet LED light (LED) alone or combined with carbamide (CP) or hydrogen (HP) peroxides. METHODS: Volunteers of a previous short-term study were recalled for 6- and 12-month follow-ups, according to the following interventions (n = 18/group): LED, CP, LED/CP, HP, and LED/HP. The objective color (ΔEab, ΔE00) and whiteness index (ΔWID) changes were calculated applying the CIELab coordinates' values obtained using a spectrophotometer. A visual shade guide determined the tooth's subjective color change (ΔSGU). Data were submitted to one-way ANOVA or Welch's ANOVA, following appropriate post hoc tests (α = 5%). RESULTS: The LED and CP groups exhibited the lowest ΔEab, ΔE00, and ΔSGU (p < 0.05), but the LED group displayed a significantly lower ΔWID. After 12 months, the LED/CP group presented a higher ΔEab and ΔE00 than the CP group (p < 0.05). ΔEab, ΔE00, ΔSGU, or ΔWID means did not differ statistically between the LED/CP and HP groups. The LED/HP group presented a higher ΔE00 than the HP group, regardless of the time. CONCLUSIONS: The bleaching efficacy of LED alone was significantly lower compared to the LED/CP and HP-containing protocols. After 12 months, the LED/CP and HP groups did not differ in bleaching efficacy. LED irradiation only increased the objective color change of bleaching gels. CLINICAL RELEVANCE: LED alone promoted a long-term perceptible bleaching, but not compatible with that of high-concentrated HP. The bleaching outcomes of violet irradiation to 37% CP were maintained over time, with LED/CP demonstrating comparable results to HP even after 12 months. NATIONAL CLINICAL TRIALS REGISTRY (REBEC): RBR-5t6bd9.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Colorimetría , Estudios de Seguimiento , Humanos , Peróxido de Hidrógeno , Peróxidos , Urea
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA