RESUMEN
Background: Canadian Arctic communities have experienced sustained syphilis transmission, with diagnoses rates 18-times higher than the national average. Remoteness from laboratory facilities leads to delays between syphilis screening and treatment, contributing to onward transmission. Rapid diagnostic tests can eliminate treatment delays via testing at the point-of-care. This study aims to describe syphilis diagnostic gaps and to estimate the impact of introducing rapid diagnostic tests at the point-of-care on syphilis transmission. Methods: To assess the population-level impact of deploying rapid diagnostic tests, an individual-based model was developed using detailed surveillance data, population surveys, and a prospective diagnostic accuracy field study. The model was calibrated to syphilis diagnoses (2017-2022) from a community of approximately 1,050 sexually active individuals. The impacts of implementing rapid diagnostic tests using whole blood (sensitivity: 92% for infectious and 81% for non-infectious syphilis; specificity: 99%) from 2023 onward was calculated using the annual median fraction of cumulative new syphilis infections averted over 2023-2032. Findings: The median modeled syphilis incidence among sexually active individuals was 44 per 1,000 in 2023. Males aged 16-30 years exhibited a 51% lower testing rate than that of their female counterparts. Maintaining all interventions constant at their 2022 levels, implementing rapid diagnostic tests could avert a cumulative 33% (90% credible intervals: 18-43%) and 37% (21-46%) of new syphilis infections over 5 and 10 years, respectively. Increasing testing rates and contact tracing may enhance the effect of rapid diagnostic tests. Interpretation: Implementing rapid diagnostic tests for syphilis in Arctic communities could reduce infections and enhance control of epidemics. Such effective diagnostic tools could enable rapid outbreak responses by providing same-day testing and treatment at the point-of-care. Funding: Canadian Institutes of Health Research.
RESUMEN
Background: Essential non-healthcare workers experienced higher rates of SARS-CoV-2 infection compared to non-essential workers. Objective: Identify characteristics associated with SARS-CoV-2 testing, infection and vaccine uptake among essential non-healthcare workers in Montréal, Québec. Methods: Secondary, cross-sectional analysis of data collected from participants prospectively recruited in two observational studies (first study, Onsite Testing Study, January-March 2021; second study, Self-Testing Study, July-October 2021) of essential non-healthcare workers in 2021. Logistic regression with generalized linear mixed models was used to explore characteristics associated with our outcomes (previous SARS-CoV-2 testing, exposure and vaccination). Results: Overall, 2,755 participants were included (first study, Onsite Testing Study, n=2,128; and second study, Self-Testing Study, n=627). A higher proportion of participants identified as male (n=1,601; 58%), non-White (n=1,527; 55%) and worked in the manufacturing/supplier sector (n=1,706; 62%). Relative to the first study, Onsite Testing Study, participants in the second study, Self-Testing Study, had higher odds (78% vs. 46%; aOR 4.1, 95% CI: 3.2-5.2) of previous SARS-CoV-2 testing and of testing positive prior to study enrolment (6.2% vs. 4.3%; aOR 1.7, 95% CI: 1.1-2.6). Individuals reporting recent SARS-CoV-2 exposure had higher odds of previous SARS-CoV-2 testing (aOR 4.0, 95% CI: 3.0-5.4), while older age (aOR 0.98, 95% CI: 0.98-0.99 per one-year increase) and being male (aOR 0.6, 95% CI: 0.5-0.7) were associated with lower odds of previous testing. Results were similar in stratified analyses. Participants from businesses with more than 50 employees had higher odds of having received a SARS-CoV-2 vaccine (91% vs. 80%; aOR 2.6, 95% CI: 1.4-4.8). Conclusion: Consideration of individual and business characteristics associated with testing and vaccination programs for SARS-CoV-2 could improve equity, uptake and impact.
RESUMEN
Importance: Rapid tests for respiratory viruses, including multiplex panels, are increasingly available in emergency departments (EDs). Their association with patient outcomes remains unclear. Objective: To determine if ED rapid respiratory virus testing in patients with suspected acute respiratory infection (ARI) was associated with decreased antibiotic use, ancillary tests, ED length of stay, and ED return visits and hospitalization and increased influenza antiviral treatment. Data Sources: Ovid MEDLINE, Embase (Ovid), Scopus, and Web of Science from 1985 to November 14, 2022. Study Selection: Randomized clinical trials of patients of any age with ARI in an ED. The primary intervention was rapid viral testing. Data Extraction and Synthesis: Preferred Reporting Items for Systematic Reviews and Meta-Analyses reporting guidelines were followed. Two independent reviewers (T.S. and K.W.) extracted data and assessed risk of bias using the Cochrane Risk of Bias, version 2.0. Estimates were pooled using random-effects models. Quality of evidence was assessed using the Grading of Recommendations, Assessment, Development, and Evaluations framework. Main Outcomes and Measures: Antibiotic use and secondary outcomes were pooled separately as risk ratios (RRs) and risk difference estimates with 95% CIs. Results: Of 7157 studies identified, 11 (0.2%; n = 6068 patients) were included in pooled analyses. Routine rapid viral testing was not associated with antibiotic use (RR, 0.99; 95% CI, 0.93-1.05; high certainty) but was associated with higher use of influenza antivirals (RR, 1.33; 95% CI, 1.02-1.75; moderate certainty) and lower use of chest radiography (RR, 0.88; 95% CI, 0.79-0.98; moderate certainty) and blood tests (RR, 0.81; 95% CI, 0.69-0.97; moderate certainty). There was no association with urine testing (RR, 0.95; 95% CI, 0.77-1.17; low certainty), ED length of stay (0 hours; 95% CI, -0.17 to 0.16; moderate certainty), return visits (RR, 0.93; 95%, CI 0.79-1.08; moderate certainty) or hospitalization (RR, 1.01; 95% CI, 0.95-1.08; high certainty). Adults represented 963 participants (16%). There was no association of viral testing with antibiotic use in any prespecified subgroup by age, test method, publication date, number of viral targets, risk of bias, or industry funding. Conclusions and Relevance: The results of this systematic review and meta-analysis suggest that there are limited benefits of routine viral testing in EDs for patients with ARI. Further studies in adults, especially those with high-risk conditions, are warranted.
Asunto(s)
Servicio de Urgencia en Hospital , Infecciones del Sistema Respiratorio , Humanos , Servicio de Urgencia en Hospital/estadística & datos numéricos , Infecciones del Sistema Respiratorio/diagnóstico , Infecciones del Sistema Respiratorio/tratamiento farmacológico , Infecciones del Sistema Respiratorio/virología , Antibacterianos/uso terapéutico , Antivirales/uso terapéutico , Tiempo de Internación/estadística & datos numéricos , Hospitalización/estadística & datos numéricosRESUMEN
BACKGROUND AND OBJECTIVES: In this proof-of-concept study, which included blood donor samples, we aimed to demonstrate how Bayesian latent class models (BLCMs) could be used to estimate SARS-CoV-2 seroprevalence in the absence of a gold standard assay under a two-phase sampling design. MATERIALS AND METHODS: To this end, 6810 plasma samples from blood donors who resided in Québec (Canada) were collected from May to July 2020 and tested for anti-SARS-CoV-2 antibodies using seven serological assays (five commercial and two non-commercial). RESULTS: SARS-CoV-2 seroprevalence was estimated at 0.71% (95% credible interval [CrI] = 0.53%-0.92%). The cPass assay had the lowest sensitivity estimate (88.7%; 95% CrI = 80.6%-94.7%), while the Héma-Québec assay had the highest (98.7%; 95% CrI = 97.0%-99.6%). CONCLUSION: The estimated low seroprevalence (which indicates a relatively limited spread of SARS-CoV-2 in Quebec) might change rapidly-and this tool, developed using blood donors, could enable a rapid update of the prevalence estimate in the absence of a gold standard. Further, the present analysis illustrates how a two-stage BLCM sampling design, along with blood donor samples, can be used to estimate the performance of new diagnostic tests and inform public health decisions regarding a new or emerging disease for which a perfect reference standard does not exist.
Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , COVID-19/epidemiología , SARS-CoV-2 , Análisis de Clases Latentes , Teorema de Bayes , Estudios Seroepidemiológicos , Sensibilidad y Especificidad , Anticuerpos Antivirales , Pruebas Diagnósticas de Rutina , Prueba de COVID-19RESUMEN
OBJECTIVES: We evaluated the field diagnostic accuracy of a syphilis rapid test (RDT), using serum and whole blood by non-laboratorians in two Canadian Arctic communities. METHODS: We implemented a multisite prospective field evaluation wherein patients were screened by an RDT containing treponemal and non-treponemal components (Chembio DPP® Syphilis Screen & Confirm) between January 2020 and December 2021. Venous whole blood and serum were collected for rapid testing and compared with laboratory-based serology reference testing using a reverse sequence algorithm of treponemal and rapid plasma reagin (RPR) testing. RESULTS: Overall, 135 whole blood and 139 serum specimens were collected from 161 participants during clinical encounters. Treponemal-RDT sensitivity against a treponemal-reference standard (38/161 confirmed cases) was similar for serum (78% [95% CI: 61-90%]) and whole blood (81% [95% CI: 63-93%]). In those with RPR titres ≥1:8 (i.e. suggestive of recent/active infection), sensitivity increased to 93% (95% CI: 77-99%) for serum and 92% (95% CI: 73-99%) for whole blood. Treponemal-RDT specificity was excellent (99% [95% CI: 95-100%]) for both specimen types. Non-treponemal-RDT sensitivity against RPR was 94% (95% CI: 80-99%) for serum and 79% (95% CI: 60-92%) for whole blood. Sensitivity increased to 100% (95% CI: 88-100%) for serum and 92% (95% CI: 73-99%) for whole blood when RPR titres ≥1:8. RDT performance with whole blood was similar to that with serum. DISCUSSION: Non-laboratorians using the RDT accurately identified individuals with infectious syphilis under real-world conditions in an intended-use setting at the point of care. Implementing the RDT can eliminate treatment delays and may enhance disease control.
Asunto(s)
Sífilis , Humanos , Prueba de Diagnóstico Rápido , Sensibilidad y Especificidad , Canadá , Serodiagnóstico de la Sífilis , Treponema pallidumRESUMEN
Prolonged eosinophilia is characteristic of trichinellosis. To determine the optimal eosinophil threshold for reflex Trichinella testing, we examined all 43 cases in Nunavik, Quebec, Canada, during 2009-2019. Using receiver operating characteristic analysis, we determined that eosinophil counts >0.8 × 109 cells/L should prompt consideration of trichinellosis and testing to rapidly identify potential outbreaks.
Asunto(s)
Eosinofilia , Trichinella , Triquinelosis , Animales , Quebec/epidemiología , Triquinelosis/diagnóstico , Triquinelosis/epidemiología , Canadá , Eosinofilia/diagnóstico , Eosinofilia/epidemiologíaRESUMEN
BACKGROUND: Intense transmission of syphilis has emerged in some Canadian Arctic communities despite screening and prevention efforts. The remoteness of most communities and limited diagnostic infrastructure yield long delays (≥14 days) between screening and treatment of cases. These hamper syphilis control efforts and may contribute to sustained transmission. Syphilis rapid diagnostic tests (RDTs) have been developed to make screening more accessible and to inform clinical decision-making within the same clinical encounter. These RDTs have been successfully deployed in several countries, but not yet in Canada. METHODS AND DESIGN: We describe the methodology of the "Stopping Syphilis Transmission in Arctic Communities Through Rapid Diagnostic Testing" (STAR) study, wherein the clinical and epidemiological impact of deploying a dual syphilis RDT in the context of ongoing transmission in Nunavut and Nunavik will be evaluated. In this prospective multisite field evaluation, sexually active individuals aged ≥14 years at risk for syphilis will be offered screening by an RDT at the point-of-care by non-laboratory trained registered nurses. Whole blood and serum specimens will be concurrently collected, when feasible, for rapid testing with an RDT containing both treponemal and non-treponemal components (Chembio DPP® Syphilis Screen & Confirm) and compared to laboratory-based reference testing according to a reverse sequence algorithm. The diagnostic accuracy of the RDT, using both whole blood and centrifuged serum specimens, will be validated under real-world conditions in remote Northern settings, outside of specialized laboratories. Additionally, screening-to-treatment time, case detection rates, and the number of infectious contacts averted by using the RDT relative to reference testing will be estimated. The impact of both diagnostic approaches on syphilis transmission dynamics will also be modeled. DISCUSSION: This study will provide much needed evidence for strengthening rapid responses to emerging syphilis outbreaks in remote Arctic regions, by supplementing traditional diagnostic strategies with an RDT to rapidly triage patients likely in need of treatment. These results will also inform the development and tailoring of future diagnostic strategies and public health responses to emerging outbreaks in the North.
Asunto(s)
Sífilis , Regiones Árticas , Canadá/epidemiología , Humanos , Estudios Prospectivos , Sífilis/diagnóstico , Sífilis/epidemiología , Serodiagnóstico de la Sífilis/métodosRESUMEN
OBJECTIVE: To identify risk factors for severe disease in children hospitalised for SARS-CoV-2 infection. DESIGN: Multicentre retrospective cohort study. SETTING: 18 hospitals in Canada, Iran and Costa Rica from 1 February 2020 to 31 May 2021. PATIENTS: Children<18 years of age hospitalised for symptomatic PCR-positive SARS-CoV-2 infection, including PCR-positive multisystem inflammatory syndrome in children (MIS-C). MAIN OUTCOME MEASURE: Severity on the WHO COVID-19 Clinical Progression Scale was used for ordinal logistic regression analyses. RESULTS: We identified 403 hospitalisations. Median age was 3.78 years (IQR 0.53-10.77). At least one comorbidity was present in 46.4% (187/403) and multiple comorbidities in 18.6% (75/403). Eighty-one children (20.1%) met WHO criteria for PCR-positive MIS-C. Progression to WHO clinical scale score ≥6 occurred in 25.3% (102/403). In multivariable ordinal logistic regression analyses adjusted for age, chest imaging findings, laboratory-confirmed bacterial and/or viral coinfection, and MIS-C diagnosis, presence of a single (adjusted OR (aOR) 1.90, 95% CI 1.13 to 3.20) or multiple chronic comorbidities (aOR 2.12, 95% CI 1.19 to 3.79), obesity (aOR 3.42, 95% CI 1.76 to 6.66) and chromosomal disorders (aOR 4.47, 95% CI 1.25 to 16.01) were independent risk factors for severity. Age was not an independent risk factor, but different age-specific comorbidities were associated with more severe disease in age-stratified adjusted analyses: cardiac (aOR 2.90, 95% CI 1.11 to 7.56) and non-asthma pulmonary disorders (aOR 3.07, 95% CI 1.26 to 7.49) in children<12 years old and obesity (aOR 3.69, 1.45-9.40) in adolescents≥12 years old. Among infants<1 year old, neurological (aOR 10.72, 95% CI 1.01 to 113.35) and cardiac disorders (aOR 10.13, 95% CI 1.69 to 60.54) were independent predictors of severe disease. CONCLUSION: We identified risk factors for disease severity among children hospitalised for PCR-positive SARS-CoV-2 infection. Comorbidities predisposing children to more severe disease may vary by age. These findings can potentially guide vaccination programmes and treatment approaches in children.
Asunto(s)
COVID-19 , Adolescente , COVID-19/complicaciones , COVID-19/diagnóstico , Prueba de COVID-19 , Niño , Niño Hospitalizado , Preescolar , Humanos , Lactante , Obesidad/epidemiología , Reacción en Cadena de la Polimerasa , Estudios Retrospectivos , Factores de Riesgo , SARS-CoV-2/genética , Síndrome de Respuesta Inflamatoria SistémicaRESUMEN
BACKGROUND: The incidence of hospitalizations for acute respiratory infections (ARI) among young Indigenous children from Northern Canada is consistently high. ARIs requiring urgent air transfer can be life-threatening and costly. We aimed to describe their epidemiology, estimate age-specific incidences, and explore factors associated with level of care required. METHODS: We undertook a retrospective cohort study of children <5 years old from Northern Canada transferred by urgent air transport for ARI from 2005 through 2014 to 5 pediatric tertiary care centers in Vancouver, Edmonton, Winnipeg, Ottawa and Montreal. Admissions were identified via ARI-related ICD-9/10 coding and forward sortation area. Descriptive statistics and univariable analyses were performed. RESULTS: Among 650 urgent air transfers, the majority were from Nunavut (n = 349, 53.7%) or Nunavik (n = 166, 25.5%), <6 months old (n = 372, 57.2%), and without underlying comorbidity (n = 458; 70.5%). Estimated annual tertiary care ARI admission rates in infants <1 year old from Nunavut (40.7/1000) and Nunavik (44.5/1000) were tenfold higher than in children aged 1 to 4 years. Bronchiolitis (n = 333, 51.2%) and pneumonia (n = 208, 32.0%) were the most common primary discharge diagnoses. Nearly half required critical care (n = 316, 48.6%); mechanical ventilation rates ranged from 7.2% to 55.9% across centres. The most common primary pathogen was respiratory syncytial virus (n = 196, 30.1%). Influenza A or B was identified in 35 cases (5.4%) and vaccine-preventable bacterial infections in 27 (4.1%) cases. INTERPRETATION: Urgent air transfers for ARI from Northern Canada are associated with high acuity. Variations in levels of care were seen across referral centers, age groups and pathogens.
Asunto(s)
Infecciones por Virus Sincitial Respiratorio , Virus Sincitial Respiratorio Humano , Infecciones del Sistema Respiratorio , Niño , Preescolar , Hospitalización , Humanos , Incidencia , Lactante , Estudios RetrospectivosRESUMEN
BACKGROUND: Rapid and accurate diagnosis of herpes simplex virus (HSV)-1 and -2 (HSV1/2) in cerebrospinal fluid (CSF) is important for patient management. OBJECTIVES: Summarize the diagnostic accuracy of commercial rapid sample-to-answer PCR assays (results in <90 minutes, without a separate nucleic acid extraction step) for HSV1/2 detection in CSF. DATA SOURCES: Four databases (MEDLINE, EMBASE, Scopus, and CENTRAL) and five conference abstract datasets from January 2012 to March 2022. STUDY ELIGIBILITY CRITERIA: Eligible diagnostic accuracy studies provided sufficient data for the construction of a standard diagnostic accuracy two-by-two table. PARTICIPANTS: Patients with suspected meningitis and/or encephalitis. TESTS: FilmArray Meningitis-Encephalitis Panel and Simplexa HSV 1&2 Direct Kit PCR. REFERENCE STANDARD: Real-time PCR assay. ASSESSMENT OF RISK OF BIAS: Two investigators independently extracted data, rated risk of bias, and assessed quality using QUADAS-2. METHODS OF DATA SYNTHESIS: Accuracy estimates were pooled using Bayesian random effects models. RESULTS: Thirty-one studies were included (27 FilmArray; 4 Simplexa), comprising 9924 samples, with 95 HSV-1 and 247 HSV-2 infections. Pooled FilmArray sensitivities were 84.3% (95% credible interval, 72.3-93.0) and 92.9% (95% credible interval (CrI), 82.0-98.5) for HSV-1 and HSV-2, respectively; specificities were 99.8% (95% CrI, 99.6-99.9) and 99.9% (95% CrI, 99.9-100). Pooled Simplexa sensitivities were 97.1% (95% CrI, 88.1-99.6) and 97.9% (95% CrI, 89.6-99.9), respectively; specificities were 98.9% (95% CrI, 96.8-99.7) and 98.9% (95% CrI, 97.1-99.7). Pooled FilmArray sensitivities favoured industry-sponsored studies by 10.0 and 13.0 percentage points for HSV-1 and HSV-2, respectively. Incomplete reporting frequently led to unclear risk of bias. Several FilmArray studies did not fully report true negative data leading to their exclusion. CONCLUSIONS: Our results suggest Simplexa is accurate for HSV1/2 detection in CSF. Moderate FilmArray sensitivity for HSV-1 suggests additional testing and/or repeat CSF sampling is required for suspected HSV encephalitis when the HSV-1 result is negative. Low prevalence of HSV-1 infections limited summary estimates' precision. Underreporting of covariates limited exploration of heterogeneity.
Asunto(s)
Encefalitis por Herpes Simple , Herpesvirus Humano 1 , Meningitis , Humanos , Herpesvirus Humano 1/genética , Teorema de Bayes , Sensibilidad y Especificidad , Encefalitis por Herpes Simple/diagnóstico , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Meningitis/diagnóstico , Líquido CefalorraquídeoRESUMEN
Importance: Longitudinal mass testing using rapid antigen detection tests (RADT) for serial screening of asymptomatic persons has been proposed for preventing SARS-CoV-2 community transmission. The feasibility of this strategy relies on accurate self-testing. Objective: To quantify the adequacy of serial self-performed SARS-CoV-2 RADT testing in the workplace, in terms of the frequency of correct execution of procedural steps and accurate interpretation of the range of possible RADT results. Design, Setting, and Participants: This prospective repeated cross-sectional study was performed from July to October 2021 at businesses with at least 2 active cases of SARS-CoV-2 infection in Montreal, Canada. Participants included untrained persons in their workplace, not meeting Public Health quarantine criteria (ie, required quarantine for 10 days after a moderate-risk contact with someone infected with SARS-CoV-2). Interpretation and performance were compared between participants who received instructions provided by the manufacturer vs those who received modified instructions that were informed by the most frequent or most critical errors we observed. Data were analyzed from October to November 2021. Exposures: RADT testing using a modified quick reference guide compared with the original manufacturer's instructions. Main Outcomes and Measures: The main outcome was the difference in correctly interpreted RADT results. Secondary outcomes included difference in proportions of correctly performed procedural steps. Additional analyses, assessed among participants with 2 self-testing visits, compared the second self-test visit with the first self-test visit using the same measures. Results: Overall, 1892 tests were performed among 647 participants, of whom 278 participants (median [IQR] age, 43 [31-55] years; 156 [56.1%] men) had at least 1 self-testing visit. For self-test visit 1, significantly better accuracy in test interpretation was observed among participants using the modified quick reference guide than those using the manufacturer's instructions for reading results that were weak positive (64 of 115 participants [55.6%] vs 20 of 163 participants [12.3%]; difference, 43.3 [95% CI, 33.0-53.8] percentage points), positive (103 of 115 participants [89.6%] vs 84 of 163 participants [51.5%]; difference, 38.1 [95% CI, 28.5-47.5] percentage points), strong positive (219 of 229 participants [95.6%] vs 274 of 326 participants [84.0%]; difference, 11.6 [95% CI, 6.8-16.3] percentage points), and invalid (200 of 229 participants [87.3%] vs 252 of 326 participants [77.3%]; difference, 10.0 [95% CI, 3.8-16.3] percentage points). Use of the modified guide was associated with improvements on self-test visit 2 for results that were weak positive (difference, 15.4 [95% CI, 0.7-30.1] percentage points), positive (difference, 19.0 [95% CI, 7.2-30.9] percentage points), and invalid (difference, 8.0 [95% CI, 0.8-15.4] percentage points). For procedural steps identified as critical for test validity, adherence to procedural testing steps did not differ meaningfully according to instructions provided or reader experience. Conclusions and Relevance: In this cross-sectional study of self-performed SARS-CoV-2 RADT in an intended-use setting, a modified quick reference guide was associated with significantly improved accuracy in RADT interpretations.
Asunto(s)
COVID-19 , SARS-CoV-2 , Adulto , COVID-19/diagnóstico , COVID-19/epidemiología , Estudios Transversales , Femenino , Humanos , Masculino , Tamizaje Masivo , Estudios Prospectivos , Lugar de TrabajoRESUMEN
OBJECTIVES: We aimed to describe the clinical characteristics of SARS-CoV-2 infection and estimate viral shedding duration in respiratory specimens. METHODS: A retrospective cohort study was performed from February 25 to March 25, 2020. In Kuwait, all suspected coronavirus disease 2019 (COVID-19) cases, contacts of cases, and returning travelers were systematically tested for SARS-CoV-2 by RT-PCR. All infected persons, regardless of symptoms, were hospitalized and serially tested until they had two negative results. Descriptive statistics and regression analyses were performed. RESULTS: Two hundred seven cases of SARS-CoV-2 infection were included in this study. About half of the cases were asymptomatic and 1.9% died. The median time to negative RT-PCR was 22 days. Increasing age, ARDS, and low peripheral white blood cell count were associated with prolonged PCR positivity. CONCLUSION: Predictors for prolonged RT-PCR positivity included increasing age, ARDS, and low white blood cell count. The findings of this study may aid in better understanding of the epidemiology of SARS-CoV-2 infection and molecular testing dynamics.
Asunto(s)
COVID-19 , Nasofaringe/virología , Orofaringe/virología , SARS-CoV-2 , Esparcimiento de Virus , Adulto , COVID-19/epidemiología , Prueba de Ácido Nucleico para COVID-19 , Femenino , Hospitalización , Humanos , Kuwait/epidemiología , Masculino , Persona de Mediana Edad , Síndrome de Dificultad Respiratoria , Estudios Retrospectivos , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificaciónRESUMEN
BACKGROUND: Bloodstream infections in septic patients may be missed due to preceding antibiotic therapy prior to obtaining blood cultures. We leveraged the FABLED cohort study to determine if the quick Sequential Organ Failure Assessment (qSOFA) score could reliably identify patients at higher risk of bacteremia in patients who may have false negative blood cultures due to previously administered antibiotic therapy. METHODS: We conducted a multi-centre diagnostic study among adult patients with severe manifestations of sepsis. Patients were enrolled in one of seven participating centres between November 2013 and September 2018. All patients from the FABLED cohort had two sets of blood cultures drawn prior to the administration of antimicrobial therapy, as well as additional blood cultures within 4 hours of treatment initiation. Participants were categorized according to qSOFA score, with a score ≥2 being considered positive. RESULTS: Among 325 patients with severe manifestations of sepsis, a positive qSOFA score (defined as a score ≥2) on admission was 58% sensitive (95% CI 48% to 67%) and 41% specific (95% CI 34% to 48%) for predicting bacteremia. Among patients with negative post-antimicrobial blood cultures, a positive qSOFA score was 57% sensitive (95% CI 42% to 70%) and 42% specific (95% CI 35% to 49%) to detect patients who were originally bacteremic prior to the initiation of therapy. CONCLUSIONS: Our results suggest that the qSOFA score cannot be used to identify patients at risk for occult bacteremia due to the administration of antibiotics pre-blood culture.
HISTORIQUE: Les infections sanguines peuvent rester non diagnostiquées chez les patients septiques avant l'obtention des cultures sanguines, en raison d'une antibiothérapie antérieure. Les chercheurs ont puisé dans l'étude de cohorte FABLED pour déterminer si le score rapide de l'évaluation séquentielle d'insuffisance des organes (Sequential Organ Failure Assessment, qSOFA) pourrait dépister les patients à plus haut risque de bactériémie avec fiabilité, malgré la possibilité de cultures sanguines faussement négatives en raison d'une antibiothérapie antérieure. MÉTHODOLOGIE: Les chercheurs ont réalisé une étude diagnostique multicentrique chez des patients adultes ayant de graves manifestations de sepsis. Les patients ont été inscrits dans l'un des sept centres participants entre novembre 2013 et septembre 2018. Tous les patients de l'étude de cohorte FABLED avaient subi deux séries de cultures sanguines avant de recevoir une thérapie antimicrobienne, de même qu'une autre série de cultures sanguines dans les quatre heures suivant le début du traitement. Les participants ont été classés en fonction de leur score de qSOFA, un score d'au moins 2 étant considéré comme positif. RÉSULTATS: Chez les 325 patients ayant de graves manifestations de sepsis, un score de qSOFA positif (défini comme un score d'au moins 2) à l'admission était sensible à 58 % (IC à 95 %, 48 % à 67 %) et spécifique à 41 % (IC à 95 %, 34 % à 48 %) pour prédire la bactériémie. Chez les patients dont les cultures sanguines étaient négatives après la prise d'antimicrobiens, un score de qSOFA positif était sensible à 57 % (IC à 95 %, 42 % à 70 %) et spécifique à 42 % (IC à 95 %, 35 % à 49 %) pour dépister les patients atteints d'une bactériémie avant le début du traitement. CONCLUSIONS: Selon les résultats, le score de qSOFA ne peut pas être utilisé pour dépister les patients à risque de bactériémie occulte à cause de l'administration d'antibiotiques avant la culture sanguine.
RESUMEN
We aimed to assess the specificity of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody detection assays among people with tissue-borne parasitic infections. We tested three SARS-CoV-2 antibody-detection assays (cPass SARS-CoV-2 neutralization antibody detection kit [cPass], Abbott SARS-CoV-2 IgG assay [Abbott Architect], and Standard Q COVID-19 IgM/IgG combo rapid diagnostic test [SD RDT IgM/SD RDT IgG]) among 559 pre-COVID-19 seropositive sera for several parasitic infections. The specificity of assays was 95 to 98% overall. However, lower specificity was observed among sera from patients with protozoan infections of the reticuloendothelial system, such as human African trypanosomiasis (Abbott Architect; 88% [95% CI, 75 to 95]) and visceral leishmaniasis (SD RDT IgG; 80% [95% CI, 30 to 99]), and from patients with recent malaria in areas of Senegal where malaria is holoendemic (ranging from 91% for Abbott Architect and SD RDT IgM to 98 to 99% for cPass and SD RDT IgG). For specimens from patients with evidence of past or present helminth infection overall, test specificity estimates were all ≥96%. Sera collected from patients clinically suspected of parasitic infections that tested negative for these infections yielded a specificity of 98 to 100%. The majority (>85%) of false-positive results were positive by only one assay. The specificity of SARS-CoV-2 serological assays among sera from patients with tissue-borne parasitic infections was below the threshold required for decisions about individual patient care. Specificity is markedly increased by the use of confirmatory testing with a second assay. Finally, the SD RDT IgG proved similarly specific to laboratory-based assays and provides an option in low-resource settings when detection of anti-SARS-CoV-2 IgG is indicated.
Asunto(s)
COVID-19 , Helmintos , Enfermedades Parasitarias , Animales , Anticuerpos Antivirales , Humanos , Inmunoglobulina M , SARS-CoV-2 , Sensibilidad y Especificidad , Pruebas SerológicasRESUMEN
BACKGROUND: Sepsis is a leading cause of morbidity, mortality, and health care costs worldwide. METHODS: We conducted a multicenter, prospective cohort study evaluating the yield of blood cultures drawn before and after empiric antimicrobial administration among adults presenting to the emergency department with severe manifestations of sepsis. Enrolled patients who had the requisite blood cultures drawn were followed for 90 days. We explored the independent association between blood culture positivity and its time to positivity in relation to 90-day mortality. RESULTS: Three hundred twenty-five participants were enrolled; 90-day mortality among the 315 subjects followed up was 25.4% (80/315). Mortality was associated with age (mean age [standard deviation] in those who died was 72.5 [15.8] compared with 62.9 [17.7] years among survivors; P < .0001), greater Charlson Comorbidity Index (2 [interquartile range {IQR}, 1-3] vs 1 [IQR, 0-3]; P = .008), dementia (13/80 [16.2%] vs 18/235 [7.7%]; P = .03), cancer (27/80 [33.8%] vs 47/235 [20.0%]; P = .015), positive quick Sequential Organ Failure Assessment score (57/80 [71.2%] vs 129/235 [54.9%]; P = .009), and normal white blood cell count (25/80 [31.2%] vs 42/235 [17.9%]; P = .02). The presence of bacteremia, persistent bacteremia after antimicrobial infusion, and shorter time to blood culture positivity were not associated with mortality. Neither the source of infection nor pathogen affected mortality. CONCLUSIONS: Although severe sepsis is an inflammatory condition triggered by infection, its 90-day survival is not influenced by blood culture positivity nor its time to positivity. CLINICAL TRIALS REGISTRATION: NCT01867905.
RESUMEN
BACKGROUND: Severe acute respiratory syndrome-related coronavirus 2 (SARS-CoV-2) surrogate neutralization assays that obviate the need for viral culture offer substantial advantages regarding throughput and cost. The cPass SARS-CoV-2 Neutralization Antibody Detection Kit (GenScript) is the first such commercially available assay that detects antibodies that block receptor-binding domain (RBD)/angiotensin-converting enzyme (ACE)-2 interaction. We aimed to evaluate cPass to inform its use and assess its added value compared with anti-RBD enzyme-linked immunosorbent assays (ELISAs). METHODS: Serum reference panels comprising 205 specimens were used to compare cPass to plaque-reduction neutralization test (PRNT) and a pseudotyped lentiviral neutralization (PLV) assay for detection of neutralizing antibodies. We assessed the correlation of cPass with an ELISA detecting anti-RBD immunoglobulin (Ig)G, IgM, and IgA antibodies at a single timepoint and across intervals from onset of symptoms of SARS-CoV-2 infection. RESULTS: Compared with PRNT-50, cPass sensitivity ranged from 77% to 100% and specificity was 95% to 100%. Sensitivity was also high compared with the pseudotyped lentiviral neutralization assay (93%; 95% confidence interval [CI], 85-97), but specificity was lower (58%; 95% CI, 48-67). Highest agreement between cPass and ELISA was for anti-RBD IgG (r = 0.823). Against the pseudotyped lentiviral neutralization assay, anti-RBD IgG sensitivity (99%; 95% CI, 94-100) was very similar to that of cPass, but overall specificity was lower (37%; 95% CI, 28-47). Against PRNT-50, results of cPass and anti-RBD IgG were nearly identical. CONCLUSIONS: The added value of cPass compared with an IgG anti-RBD ELISA was modest.
RESUMEN
BACKGROUND: Of all microbiological tests performed, blood cultures have the most impact on patient care. Timely results are essential, especially in the management of sepsis. While there are multiple available blood culture systems on the market, they have never been compared in a prospective study in a critically ill population. METHODS: We performed an analysis of the FABLED study cohort to compare culture results and time to positivity (TTP) of 2 widely used blood culture systems: BacT/Alert and BACTEC. In this multisite prospective study, patients with severe manifestations of sepsis had cultures drawn before antibiotics using systematic enrollment criteria and blood drawing methodology allowing for minimization of pre-analytical biases. RESULTS: We enrolled 315 patients; 144 had blood cultures (47 positive) with BacT/Alert and 171 with BACTEC (53 positive). Patients whose blood cultures were processed using the BacT/Alert system were younger (median, 64 vs 70 years; Pâ =â .003), had a higher proportion of HIV (9.03% vs 1.75%; Pâ =â .008) and a lower qSOFA (Pâ =â .003). There were no statistically significant differences in the most commonly identified bacterial species. TTP was shorter for BACTEC (median [interquartile range {IQR}], 12.5 [10-14] hours) compared with BacT/Alert (median [IQR], 17 [14-21] hours; Pâ <â .0001). CONCLUSIONS: In this large prospective multi-centre study comparing the two blood culture systems among patients with severe manifestations of sepsis, and using a rigorous pre-analytical methodology, the BACTEC system yielded positive culture results 4.5 hours earlier than BacT/Alert. These results apply to commonly isolated bacteria. However, our study design did not allow direct comparison of TTP for unusual pathogens nor of clinical sensitivity between systems. More research is needed to determine the clinical implications of this finding.
RESUMEN
Accurate serologic tests to detect host antibodies to severe acute respiratory syndrome-related coronavirus 2 (SARS-CoV-2) will be critical for the public health response to the coronavirus disease 2019 pandemic. Many use cases are envisaged, including complementing molecular methods for diagnosis of active disease and estimating immunity for individuals. At the population level, carefully designed seroepidemiologic studies will aid in the characterization of transmission dynamics and refinement of disease burden estimates and will provide insight into the kinetics of humoral immunity. Yet, despite an explosion in the number and availability of serologic assays to test for antibodies against SARS-CoV-2, most have undergone minimal external validation to date. This hinders assay selection and implementation, as well as interpretation of study results. In addition, critical knowledge gaps remain regarding serologic correlates of protection from infection or disease, and the degree to which these assays cross-react with antibodies against related coronaviruses. This article discusses key use cases for SARS-CoV-2 antibody detection tests and their application to serologic studies, reviews currently available assays, highlights key areas of ongoing research, and proposes potential strategies for test implementation.
Asunto(s)
Betacoronavirus/inmunología , Técnicas de Laboratorio Clínico , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/inmunología , Neumonía Viral/diagnóstico , Neumonía Viral/inmunología , Pruebas Serológicas/métodos , COVID-19 , Prueba de COVID-19 , Humanos , Pandemias , SARS-CoV-2 , Estudios SeroepidemiológicosRESUMEN
To estimate the impact of implementing in-hospital enterovirus (EV) polymerase chain reaction (PCR) testing of cerebrospinal fluid (CSF) with same-day turn-around-time (TAT) on length-of-stay (LOS), antibiotic use and on cost per patient with suspected EV meningitis, compared with testing at an outside reference laboratory. A model-based analysis using a retrospective cohort of all hospitalized children with CSF EV PCR testing done between November 2013 and 2017. The primary outcome measured was the potential date of discharge if the EV PCR result had been available on the same day. Patients with positive EV PCR were considered for potential earlier discharge once clinically stable with no reason for hospitalization other than intravenous antibiotics. Descriptive statistics and cost-sensitivity analyses were performed. CSF EV PCR testing was done on 153 patients, of which 44 (29%) had a positive result. Median test TAT was 5.3 days (IQR 3.9-7.6). Median hospital LOS was 5 days (IQR 3-12). Most (86%) patients received intravenous antibiotics with mean duration of 5.72 ± 6.51 days. No patients with positive EV PCR had a serious bacterial infection. We found that same-day test TAT would reduce LOS and duration of intravenous antibiotics by 0.50 days (95%CI 0.33-0.68) and 0.67 days (95%CI 0.42-0.91), respectively. Same-day test TAT was associated with a cost reduction of 342.83CAD (95%CI 178.14-517.00) per patient with suspected EV meningitis. Compared with sending specimens to a reference laboratory, performing CSF EV PCR in-hospital with same-day TAT was associated with decreased LOS, antibiotic therapy, and cost per patient.