Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Rheumatol Int ; 39(12): 2119-2127, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31535169

RESUMEN

The objective of our study was to standardize magnetic resonance imaging (MRI) assessment of spine and sacroiliac joints in patients with axial spondyloarthritis (axSpA) and/or inflammatory spinal pain, by creating checklists and templates based on the opinions of rheumatologists and radiologists. A scientific committee developed a series of questionnaires with multiple items regarding MRI in patients with axial inflammatory pain and/or axSpA. Then an expert panel of rheumatologists and radiologists rated all items in a 9-point Likert scale. Finally, the scientific committee and the expert panel met to create the definitive documents. Several definitive checklists and templates were generated for rheumatologist-requested MRI and for radiologist-requested MRI reports of sacroiliac joint and spinal examinations. A technical requirement protocol was also agreed on. Our results could be useful in increasing understanding between rheumatologists and radiologists regarding MRI in axSpA diagnosis and follow-up.


Asunto(s)
Lista de Verificación , Imagen por Resonancia Magnética , Articulación Sacroiliaca/diagnóstico por imagen , Columna Vertebral/diagnóstico por imagen , Espondiloartritis/diagnóstico por imagen , Humanos , Sacroileítis/diagnóstico por imagen , Encuestas y Cuestionarios
2.
Med Clin (Barc) ; 151(3): 89-96, 2018 08 10.
Artículo en Inglés, Español | MEDLINE | ID: mdl-29096966

RESUMEN

INTRODUCTION: Fine needle aspiration biopsy (FNAB) is the gold standard screening technique used in the diagnostic protocol for thyroid nodules. However, it is not free of complications. OBJECTIVE: To identify thyroid nodules in which FNAB could be avoided during the diagnostic process by means of the use of a high-resolution ultrasonography or elastography. MATERIAL AND METHOD: A prospective, non-randomized study was carried out. Single thyroid nodules and dominant nodules of multinodular goiter were included. Patients who had undergone thyroid surgery in the past were excluded. All patients underwent a high-resolution ultrasound and elastography, and, subsequently, a FNAB. We analyzed the ultrasound variables in 2D and Doppler, followed by the elastographic variables, and the results of the FNAB according to Bethesda. To correlate the data, the nodules were classified as benign or malignant. Student's t test, the Chi-square test and a logistic regression analysis were applied for the statistical analysis. RESULTS: A total of 221 thyroid nodules were analyzed, 32 of which were malignant (14%). The most predictive ultrasound findings of malignancy (P<.05) were a hypoechoic or complex echostructure (OR=11.832), the presence of microcalcifications (OR=9.637) and chaotic vascularization observed in the Doppler (OR=46.464). With regard to the elastography, elastographic patterns i and ii were seen to be associated with benignity (P=.0004 and P<.0001, respectively). When type i or ii elastography was combined with an ultrasound showing a non-hypoechoic nor complex echostructure, without microcalcifications nor chaotic vascularization in the Doppler ultrasound, 100% of the cases were benign with a specificity of 100% and a sensitivity of 14%. CONCLUSIONS: The combination of a high-resolution ultrasound with an elastography makes it possible to select cases where a FNAB does not have to be performed. Cases susceptible to a periodic follow-up without the use of a FNAB are those without a hypoechoic nor complex structure, no microcalcifications, non-chaotic vascularization and a type i or ii elastography.


Asunto(s)
Nódulo Tiroideo/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Femenino , Bocio Nodular/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Nódulo Tiroideo/patología , Ultrasonografía/métodos
4.
J Ultrasound Med ; 30(7): 975-9, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21705730

RESUMEN

OBJECTIVES: The purposes of this study were to investigate interobserver reproducibility using acoustic radiation force impulse imaging and to develop an acoustic radiation force impulse scoring system. METHODS: Fifty healthy volunteers with normal liver function test values were selected for the study. Shear wave velocity measurements, expressed in meters per second, were taken in a deep portion of liver segment 6. Two observers with different levels of experience performed the measurements independently and blindly. RESULTS: All of the measurements taken by the 2 observers were valid, even in volunteers with a body mass index of greater than 28 kg/m(2). The results point to very good interobserver reproducibility of shear wave velocity measurements, with an intraclass coefficient correlation of 0.86 (P < .001). CONCLUSIONS: The results of this study show that shear wave velocity measurements using the acoustic radiation force impulse technique and a standardized protocol are accurate and reproducible.


Asunto(s)
Hígado/diagnóstico por imagen , Acústica , Adulto , Anciano , Índice de Masa Corporal , Femenino , Humanos , Cirrosis Hepática/diagnóstico por imagen , Pruebas de Función Hepática , Masculino , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...