Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 181
Filtrar
1.
BMC Infect Dis ; 24(1): 650, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38943088

RESUMEN

BACKGROUND: Intravenous fosfomycin (IVFOF) is gaining interest in severe infections. Its use may be limited by adverse events (AEs). Little experience exists on IVFOF therapeutic drug monitoring (TDM) in real-life setting. PATIENTS AND METHODS: Retrospective study of patients receiving IVFOF for > 48 h at Policlinico Hospital (Milan, Italy) from 01/01/2019 to 01/01/2023. AEs associated to IVFOF graded CTCAE ≥ II were considered. Demographic and clinical risk factors for IVFOF-related AEs were analysed with simple and multivariable regression models. The determination of IVFOF TDM was made by a rapid ultraperformance liquid chromatography mass spectrometry method (LC-MS/MS) on plasma samples. The performance of TDM (trough levels (Cmin) in intermittent infusion, steady state levels (Css) in continuous infusion) in predicting AEs ≤ 5 days after its assessment was evaluated. RESULTS: Two hundred and twenty-four patients were included. At IVFOF initiation, 81/224 (36.2%) patients were in ICU and 35/224 (15.7%) had septic shock. The most frequent infection site was the low respiratory tract (124/224, 55.4%). Ninety-five patients (42.4%) experienced ≥ 1AEs, with median time of 4.0 (2.0-7.0) days from IVFOF initiation. Hypernatremia was the most frequent AE (53/224, 23.7%). Therapy discontinuation due to AEs occurred in 38/224 (17.0%). ICU setting, low respiratory tract infections and septic shock resulted associated with AEs (RRadjusted 1.59 (95%CI:1.09-2.31), 1.46 (95%CI:1.03-2.07) and 1.73 (95%CI:1.27-2.37), respectively), while IVFOF daily dose did not. Of the 68 patients undergone IVFOF TDM, TDM values predicted overall AEs and hypernatremia with AUROC of 0.65 (95%CI:0.44-0.86) and 0.91 (95%CI:0.79-1.0) respectively for Cmin, 0.67 (95%CI:0.39-0.95) and 0.76 (95%CI:0.52-1.0) respectively for Css. CONCLUSIONS: We provided real world data on the use of IVFOF-based regimens and associated AEs. IVFOF TDM deserves further research as it may represent a valid tool to predict AEs. KEY POINTS: Real world data on intravenous fosfomycin for severe bacterial infections. AEs occurred in over 40% (therapy discontinuation in 17%) and were related to baseline clinical severity but not to fosfomycin dose. TDM showed promising results in predicting AEs.


Asunto(s)
Antibacterianos , Monitoreo de Drogas , Fosfomicina , Humanos , Fosfomicina/efectos adversos , Fosfomicina/administración & dosificación , Fosfomicina/uso terapéutico , Femenino , Masculino , Estudios Retrospectivos , Antibacterianos/efectos adversos , Antibacterianos/administración & dosificación , Antibacterianos/uso terapéutico , Persona de Mediana Edad , Factores de Riesgo , Anciano , Administración Intravenosa , Italia , Adulto , Espectrometría de Masas en Tándem
2.
Int J Mol Sci ; 25(12)2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38928486

RESUMEN

Haemoglobin disorders represent a heterogeneous group of inherited conditions that involve at least one genetic abnormality in one or more of the globin chains, resulting in changes in the structure, function, and/or amount of haemoglobin molecules, which are very important for their related clinical aspects. Detecting and characterizing these disorders depends primarily on laboratory methods that employ traditional approaches and, when necessary, newer methodologies essential for solving a number of diagnostic challenges. This review provides an overview of key laboratory techniques in the diagnosis of haemoglobinopathies, focusing on the challenges, advancements, and future directions in this field. Moreover, many haemoglobinopathies are benign and clinically silent, but it is not uncommon to find unexpected variants during routine laboratory tests. The present work reported a rare and clinically interesting case of identification of haemoglobin fractions in an adult man by the determination of glycated haemoglobin (HbA1c) during a routine laboratory assessment, highlighting how the correct use of laboratory data can modify and improve the patient's clinical management.


Asunto(s)
Hemoglobinopatías , Técnicas de Diagnóstico Molecular , Humanos , Hemoglobinopatías/diagnóstico , Hemoglobinopatías/genética , Hemoglobinopatías/sangre , Técnicas de Diagnóstico Molecular/métodos , Hemoglobinas/genética , Hemoglobinas/análisis , Masculino , Hemoglobina Glucada/análisis , Hemoglobinas Anormales/genética
3.
Clin Chem Lab Med ; 62(8): 1474-1482, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-38836433

RESUMEN

Analytical performance specifications (APS) based on outcomes refer to how 'good' the analytical performance of a test needs to be to do more good than harm to the patient. Analytical performance of a measurand affects its clinical performance. Without first setting clinical performance requirements, it is difficult to define how good analytically the test needs to be to meet medical needs. As testing is indirectly linked to health outcomes through clinical decisions on patient management, often simulation-based studies are used to assess the impact of analytical performance on the probability of clinical outcomes which is then translated to Model 1b APS according to the Milan consensus. This paper discusses the related key definitions, concepts and considerations that should assist in finding the most appropriate methods for deriving Model 1b APS. We review the advantages and limitations of published methods and discuss the criteria for transferability of Model 1b APS to different settings. We consider that the definition of the clinically acceptable misclassification rate is central to Model 1b APS. We provide some examples and guidance on a more systematic approach for first defining the clinical performance requirements for tests and we also highlight a few ideas to tackle the future challenges associated with providing outcome-based APS for laboratory testing.


Asunto(s)
Técnicas de Laboratorio Clínico , Humanos , Técnicas de Laboratorio Clínico/normas
4.
Clin Chem Lab Med ; 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38888156

RESUMEN

Drepanocytosis is a genetic disease relevant for its epidemiological, clinical and socio-economic aspects. In our country the prevalence is highly uneven with peaks in former malaria areas, but migration flows in recent years have led to significant changes. In this document we review the screening programs currently existing in Italy with particular emphasis on newborn screening, which in other countries around the world, including within Europe, is at most universal and mandatory. The essential laboratory issues are reviewed, from sampling aspects (cord blood or peripheral), to the analytical (analytical methods dedicated to neonatal screening and adult carrier detection) and post analytical (reporting, informative) ones. An economic analysis based on data collected in the province of Modena is also proposed, clearly showing that neonatal screening is also beneficial from an economic point of view.

5.
Clin Chem Lab Med ; 62(8): 1531-1537, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-38801089

RESUMEN

Analytical performance specifications (APS) are used for decisions about the required analytical quality of pathology tests to meet clinical needs. The Milan models, based on clinical outcome, biological variation, or state of the art, were developed to provide a framework for setting APS. An approach has been proposed to assign each measurand to one of the models based on a defined clinical use, physiological control, or an absence of quality information about these factors. In this paper we propose that in addition to such assignment, available information from all models should be considered using a risk-based approach that considers the purpose and role of the actual test in a clinical pathway and its impact on medical decisions and clinical outcomes in addition to biological variation and the state-of-the-art. Consideration of APS already in use and the use of results in calculations may also need to be considered to determine the most appropriate APS for use in a specific setting.


Asunto(s)
Control de Calidad , Humanos , Técnicas de Laboratorio Clínico/normas , Modelos Teóricos
6.
J Infect Dis ; 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38547499

RESUMEN

Enterovirus D68 (EV-D68) infections are associated with severe respiratory disease and acute flaccid myelitis (AFM). The European Non-Polio Enterovirus Network (ENPEN) aimed to investigate the epidemiological and genetic characteristics of EV-D68 and its clinical impact during the fall-winter season of 2021/22. From 19 European countries, 58 institutes reported 10,481 (6.8%) EV-positive samples of which 1,004 (9.6%) were identified as EV-D68 (852 respiratory samples). Clinical data was reported for 969 cases. 78.9% of infections were reported in children (0-5 years); 37.9% of cases were hospitalised. Acute respiratory distress was commonly noted (93.1%) followed by fever (49.4%). Neurological problems were observed in 6.4% of cases with six reported with AFM. Phylodynamic/Nextstrain and phylogenetic analyses based on 694 sequences showed the emergence of two novel B3-derived lineages, with no regional clustering. In conclusion, we describe a large-scale EV-D68 European upsurge with severe clinical impact and the emergence of B3-derived lineages.

7.
Int J Infect Dis ; 142: 106998, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38458420

RESUMEN

OBJECTIVES: Following the alert of echovirus 11 (E-11) infection in neonates in EU/EEA Member States, we conducted an investigation of E-11 circulation by gathering data from community and hospital surveillance of enterovirus (EV) in northern Italy from 01 August 2021 to 30 June 2023. METHODS: Virological results of EVs were obtained from the regional sentinel surveillance database for influenza-like illness (ILI) in outpatients, and from the laboratory database of ten hospitals for inpatients with either respiratory or neurological symptoms. Molecular characterization of EVs was performed by sequence analysis of the VP1 gene. RESULTS: In our ILI series, the rate of EV-positive specimens showed an upward trend from the end of May 2023, culminating at the end of June, coinciding with an increase in EV-positive hospital cases. The E-11 identified belonged to the D5 genogroup and the majority (83%) were closely associated with the novel E-11 variant, first identified in severe neonatal infections in France since 2022. E-11 was identified sporadically in community cases until February 2023, when it was also found in hospitalized cases with a range of clinical manifestations. All E-11 cases were children, with 14 out of 24 cases identified through hospital surveillance. Of these cases, 60% were neonates, and 71% had severe clinical manifestations. CONCLUSION: Baseline epidemiological data collected since 2021 through EV laboratory-based surveillance have rapidly tracked the E-11 variant since November 2022, alongside its transmission during the late spring of 2023.


Asunto(s)
Infecciones por Enterovirus , Enterovirus , Virosis , Niño , Recién Nacido , Humanos , Lactante , Enterovirus/genética , Vigilancia de Guardia , Pacientes Internos , Infecciones por Enterovirus/diagnóstico , Enterovirus Humano B/genética , Italia/epidemiología , Hospitales , Filogenia
8.
Front Genet ; 15: 1358334, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38544803

RESUMEN

Thanks to a long-read sequencing (LRS) approach, in this study, we have reported a molecularly solved case of a proband with a clinical diagnosis of Cornelia de Lange syndrome (CDLS), which is a multisystemic disorder whose causative molecular defects involve cohesin complex genes, with NIPBL located at 5p13.2 accounting for approximately 50%-60% of CDLS cases. The first-tier tests revealed an abnormal karyotype 46,XY,t(5;15)(p13;q25)dn and a preserved NIPBL sequencing. Copy number variants (CNVs) at the translocation breakpoints, in disease genes, or in probably pathogenic loci were excluded by a-CGH analysis. Through fluorescence in situ hybridization (FISH) analysis on derivative chromosome 5, the breakpoint was relocated 3 Mb far from NIPBL 5'UTR, which seemed fully maintained as FISH-probe mapping to the gene showed no split signals. Moreover, tri-color FISH revealed an apparently balanced paracentric inversion including NIPBL on derivative 5. Based on the strong clinical suspicion, we evaluated the NIPBL transcript by RT-qPCR that revealed a normal amount of transcript till exon 22 and a halved amount of the transcript from exon 23 to 3'UTR, indicating the expression of a truncated transcript probably leading to a defective protein. Despite RT-qPCR confirmed the patient's CDLS clinical diagnosis, the molecular mechanism underlying this event remained to be an unsolved challenge for years. The LRS approach with nanopore technologies was able to fill the gap in this complex scenario and highlighted a chromothripsis event marked out at 5p13.2 by 36 breaks clustered in a 7.3-Mb region. The NIPBL gene was disrupted by 16 breaks and the resulting fragments were relocated in different positions and orientations. LRS confirmed the previous findings, and it has been proven to be crucial to define the complex chromosomal rearrangement in this patient which escaped current diagnostic investigations. Its application in the clinical practice will contribute to solve the unsolved.

9.
Clin Chem Lab Med ; 62(8): 1470-1473, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-38411177

RESUMEN

OBJECTIVES: Even if the topic of the analytical quality required to provide laboratory results "fit for purpose" exists since the beginning of the modern medical laboratory, there is the suspect that the expression "Analytical Performance Specifications" (APS) is not well-known. To investigate this aspect a survey was conducted. METHODS: A questionnaire with seven questions related to the knowledge about the topic, the sources of information and the criteria used by the laboratories to set the APS and their applications was prepared. It was distributed to all the clinical pathology laboratories of Lombardy Region (143) and to the members of SIBioC Laboratory Medicine (excluding Lombardy). RESULTS: We received 201 replies: 127 from Lombardy and 74 from the rest of Italy. Fifteen percent declared to ignore the meaning of APS and only 64 % of those knowing the meaning of the term declared to use them in the daily practice. The state-of-the-art was the principle used more frequently to set APS (about 48 %) followed by biological variation (41 %), and APS were typically applied to set goals for Internal Quality Control for selected measurands. Usually imprecision or total error APS were used, much less frequently uncertainty APS. In fact only 27 % of the laboratories declared to have calculated the measurement uncertainty for part or the majority of their measurands. CONCLUSIONS: Even considering the limits of a survey that relies upon self-declarations, it appears clearly that, at list in Italy, there is some work to be done to promote the concept and the use of APS.


Asunto(s)
Laboratorios Clínicos , Control de Calidad , Italia , Encuestas y Cuestionarios , Humanos , Laboratorios Clínicos/normas , Técnicas de Laboratorio Clínico/normas
10.
JHEP Rep ; 6(2): 100966, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38274491

RESUMEN

Background & Aims: Bulevirtide (BLV) was approved for the treatment of compensated chronic hepatitis D virus (HDV) infection in Europe in 2020. However, research into the effects of the entry inhibitor BLV on HDV-host dynamics is in its infancy. Methods: Eighteen patients with HDV under nucleos(t)ide analogue treatment for hepatitis B, with compensated cirrhosis and clinically significant portal hypertension, received BLV 2 mg/day. HDV RNA, alanine aminotransferase (ALT), and hepatitis B surface antigen (HBsAg) were measured at baseline, weeks 4, 8 and every 8 weeks thereafter. A mathematical model was developed to account for HDV, HBsAg and ALT dynamics during BLV treatment. Results: Median baseline HDV RNA, HBsAg, and ALT were 4.9 log IU/ml [IQR: 4.4-5.8], 3.7 log IU/ml [IQR: 3.4-3.9] and 106 U/L [IQR: 81-142], respectively. During therapy, patients fit into four main HDV kinetic patterns: monophasic (n = 2), biphasic (n = 10), flat-partial response (n = 4), and non-responder (n = 2). ALT normalization was achieved in 14 (78%) patients at a median of 8 weeks (range: 4-16). HBsAg remained at pre-treatment levels. Assuming that BLV completely (∼100%) blocks HDV entry, modeling indicated that two HDV-infected cell populations exist: fast HDV clearing (median t1/2 = 13 days) and slow HDV clearing (median t1/2 = 44 days), where the slow HDV-clearing population consisted of ∼1% of total HDV-infected cells, which could explain why most patients exhibited a non-monophasic pattern of HDV decline. Moreover, modeling explained ALT normalization without a change in HBsAg based on a non-cytolytic loss of HDV from infected cells, resulting in HDV-free HBsAg-producing cells that release ALT upon death at a substantially lower rate compared to HDV-infected cells. Conclusion: The entry inhibitor BLV provides a unique opportunity to understand HDV, HBsAg, ALT, and host dynamics. Impact and implications: Mathematical modeling of hepatitis D virus (HDV) treatment with the entry inhibitor bulevirtide (BLV) provides a novel window into the dynamics of HDV RNA and alanine aminotransferase. Kinetic data from patients treated with BLV monotherapy can be explained by hepatocyte populations with different basal HDV clearance rates and non-cytolytic clearance of infected cells. While further studies are needed to test and refine the kinetic characterization described here, this study provides a new perspective on viral dynamics, which could inform evolving treatment strategies for HDV.

11.
Liver Int ; 44(3): 831-837, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38247385

RESUMEN

BACKGROUND AND AIM: Management of chronic hepatitis delta (CHD) requires reliable tests for HDV RNA quantification. The aim of the study was to compare two extraction methods for the quantification of HDV RNA in untreated and bulevirtide (BLV)-treated CHD patients. METHODS: Frozen sera from untreated and BLV-treated CHD patients were tested in a single-centre study for HDV RNA levels (Robogene 2.0, Roboscreen GmbH, Leipzig, Germany; LOD 6 IU/mL) with two extraction methods: manual (INSTANT Virus RNA/DNA kit; Roboscreen GmbH, Leipzig, Germany) versus automated (EZ1 DSP Virus Kit; Qiagen, Hilden, Germany). BLV-treated patients were sampled at baseline and during therapy. RESULTS: Two hundred sixty-four sera collected from 157 CHD (139 untreated, 18 BLV-treated) patients were analysed: age 51 (28-78), 59% males, 90% of European origin, 60% cirrhotics, ALT 85 (17-889) U/L, HBsAg 3.8 (1.7-4.6) Log IU/mL, 81% HBV DNA undetectable, 98% HDV genotype 1. Median HDV RNA was 4.53 (.70-8.10) versus 3.77 (.70-6.93) Log IU/mL by manual versus automated extraction (p < .0001). Manual extraction reported similar HDV RNA levels in 31 (20%) patients, higher in 119 (76%) [+.5 and +1 log10 in 60; > +1 log10 in 59] and lower in 7 (4%). Among 18 BLV-treated patients, rates of HDV RNA < LOD significantly differed between the two assays at Weeks 16 and 24 (0% vs. 22%, p = .02; 11% vs. 44%, p = .03), but not at later timepoints. By contrast, virological response rates were similar. CONCLUSIONS: Quantification of HDV RNA by Robogene 2.0 is influenced by the extraction method, the manual extraction being 1 Log more sensitive.


Asunto(s)
Hepatitis D , Virus de la Hepatitis Delta , Masculino , Humanos , Persona de Mediana Edad , Femenino , Virus de la Hepatitis Delta/genética , ARN Viral , ADN Viral , Hepatitis D/tratamiento farmacológico , Alemania , Virus de la Hepatitis B/genética , Antígenos de Superficie de la Hepatitis B , Antivirales/uso terapéutico
13.
Clin Chem Lab Med ; 62(5): 939-945, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-37999718

RESUMEN

OBJECTIVES: Severe deficiency of growth hormone (GHD) of the newborn is a rare but potentially life-threatening disease. GH measured during the first week of life, using dried blood spots (DBS), may offer several advantages. Aim of the study was to estimate the reference values for GH in newborns by a new analytical method using DBS. METHODS: Using a new developed analytical method, GH was estimated from DBS of 1,036 healthy newborns attending the Neonatology Unit of Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico of Milan in the period July-October 2021. Reference values for GH deficiency were estimated by the Harrell-Davis bootstrap method, with 90 %CI calculated by the bias-corrected and accelerated bootstrap method. RESULTS: All GH measurements required 33 analytical sessions (8 months) with a CV% for calibration curve slopes equal to 6.9 %. Intermediate precision evaluated by measurement of low (3 µg/L) and high (10 µg/L) quality controls was, respectively, 14 and 6.5 %. GH reference values, estimated at percentiles 1.0st, 2.5th and 5.0th, and their 90 %CI, were, respectively, 4.5 µg/L (90 %CI 3.8-5.1), 5.9 µg/L (90 %CI 5.4-6.4) and 7.0 µg/L (90 %CI 6.7-7.3). GH levels were not associated with sex, standard deviation scores, birth weight, gestational age, type of delivery or mother's variables (age, smoking habit, gestational diabetes). CONCLUSIONS: Validation data suggest that this method can be used to measured GH in newborns using DBS. The reference values estimated in this study are in accordance with previous published works using ELISA and may help confirming the clinical suspicion of neonatal GHD.


Asunto(s)
Hormona del Crecimiento , Hormona de Crecimiento Humana , Recién Nacido , Humanos , Valores de Referencia , Peso al Nacer , Ensayo de Inmunoadsorción Enzimática , Factor I del Crecimiento Similar a la Insulina/análisis
14.
United European Gastroenterol J ; 12(3): 364-373, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38141028

RESUMEN

BACKGROUND & AIMS: Hepatic fat content can be non-invasively estimated by controlled attenuation parameter (CAP) during transient elastography. The aim of this study was to examine the determinants and predictors of CAP values in individuals with metabolic dysfunction. METHODS: We enrolled 1230 consecutive apparently healthy individuals (Liver-Bible-2022 cohort) with ≥3 metabolic dysfunction features. CAP was measured by Fibroscan. CAP determinants and predictors were identified using backward stepwise analysis and introduced in generalized linear models. RESULTS: Participants were predominantly males (82.9%), mean age was 53.8 ± 6.4 years, 600 (48.8%) had steatosis (CAP ≥ 275 dB/m), and 27 had liver stiffness measurement (LSM) ≥ 8 kPa. CAP values correlated with LSM (p < 10-22). In multivariable analysis, fasting insulin and abdominal circumference (AC) were the main determinants of CAP (p < 10-6), together with body mass index (BMI; p < 10-4), age, diabetes, triglycerides, ferritin, and lower HDL and thyroid stimulating hormone (TSH; p < 0.05 for all). In a subset of 592 participants with thyroid hormone measurement, we found an association between higher free triiodothyronine levels, correlating with lower TSH, and CAP values, independent of TSH and of levothyroxine treatment (p = 0.0025). A clinical CAP score based on age, BMI, AC, HbA1c, ALT, and HDL predicted CAP ≥ 275 dB/m with moderate accuracy (AUROC = 0.73), which was better than that of the Fatty Liver Index and of ALT (AUROC = 0.70/0.61, respectively) and validated it in multiple cohorts. CONCLUSION: Abdominal adiposity and insulin resistance severity were the main determinants of CAP in individuals with metabolic dysfunction and may improve steatotic liver disease risk stratification. CAP values were modulated by the hypophysis-thyroid axis.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hígado Graso , Masculino , Humanos , Persona de Mediana Edad , Femenino , Índice de Masa Corporal , Tirotropina
15.
Pediatrics ; 152(5)2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37830167

RESUMEN

OBJECTIVES: To evaluate the rate of postnatal infection during the first month of life in neonates born to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-positive mothers during the predominant circulation of the omicron (B.1.1.529) variant. METHODS: This prospective, 10-center study enrolled mothers infected by SARS-CoV-2 at delivery and their infants, if both were eligible for rooming-in, between December 2021 and March 2022. Neonates were screened for SARS-CoV-2 RNA at 1 day of life (DOL), 2 to 3 DOL, before discharge, and twice after hospital discharge. Mother-infant dyads were managed under a standardized protocol to minimize the risk of viral transmission. Sequencing data in the study area were obtained from the Italian Coronavirus Disease 2019 Genomic platform. Neonates were included in the final analysis if they were born when the omicron variant represented >90% of isolates. RESULTS: Eighty-two percent (302/366) of mothers had an asymptomatic SARS-CoV-2 infection. Among 368 neonates, 1 was considered infected in utero (0.3%), whereas the postnatal infection rate during virtually exclusive circulation of the omicron variant was 12.1%. Among neonates infected after birth, 48.6% became positive during the follow-up period. Most positive cases at follow-up were detected concurrently with the peak of coronavirus disease 2019 cases in Italy. Ninety-seven percent of the infected neonates were asymptomatic. CONCLUSIONS: The risk of early postnatal infection by the SARS-CoV-2 omicron variant is higher than that reported for previously circulating variants. However, protected rooming-in practice should still be encouraged given the paucity of symptoms in infected neonates.


Asunto(s)
COVID-19 , Complicaciones Infecciosas del Embarazo , Lactante , Recién Nacido , Femenino , Humanos , Embarazo , Madres , Estudios Prospectivos , ARN Viral , SARS-CoV-2/genética , Complicaciones Infecciosas del Embarazo/diagnóstico , Complicaciones Infecciosas del Embarazo/epidemiología , Transmisión Vertical de Enfermedad Infecciosa
16.
J Clin Med ; 12(17)2023 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-37685542

RESUMEN

To characterize the immunogenicity of mRNA-1273 (Moderna, Cambridge, MA, USA) vaccine in HIV-positive hemophilic patients during the third COVID-19 wave in Italy and to investigate biomarkers of coagulation and endothelial perturbation before and after complete vaccination schedule, twenty-three consecutive adult HIV-positive patients with hemophilia were included. Blood was collected before and two weeks after vaccination. We measured anti-SARS-CoV-2 spike protein antibodies to assess immunogenicity; circulating biomarkers of coagulation (protein C and D-dimer), endothelial perturbation (von Willebrand factor (VWF)) and anti-Platelet Factor 4 (PF4) antibodies were analyzed. Flow-based analysis of thrombus formation was performed in nine patients using a flow-chamber device. Two weeks after completing the vaccination schedule, all patients had anti-spike antibodies values consistent with an effective immunization. Mean (±standard deviation) basal values of protein C and VWF (106 ± 21% and 171 ± 45%, respectively) were not significantly different from data obtained two weeks after the second dose (103 ± 20%, 162 ± 43%, respectively). D-dimer median values (interquartile range) were not significantly different at baseline (442 (603-142) ng/mL) and after the second dose (477 (654-262) ng/mL). Anti-PF4 antibodies were detected in three patients with no associated clinical manifestations. No significant differences were found in flow-based analysis of thrombus formation. Our data demonstrate that in HIV-positive patients with hemophilia, SARS-CoV-2 vaccination is effective and safe, with no effects on coagulation and endothelial perturbation.

17.
Clin Chem ; 69(11): 1227-1237, 2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37725906

RESUMEN

It is important for external quality assessment materials (EQAMs) to be commutable with clinical samples; i.e., they should behave like clinical samples when measured using end-user clinical laboratory in vitro diagnostic medical devices (IVD-MDs). Using commutable EQAMs makes it possible to evaluate metrological traceability and/or equivalence of results between IVD-MDs. The criterion for assessing commutability of an EQAM between 2 IVD-MDs is that its result should be within the prediction interval limits based on the statistical distribution of the clinical sample results from the 2 IVD-MDs being compared. The width of the prediction interval is, among other things, dependent on the analytical performance characteristics of the IVD-MDs. A presupposition for using this criterion is that the differences in nonselectivity between the 2 IVD-MDs being compared are acceptable. An acceptable difference in nonselectivity should be small relative to the analytical performance specifications used in the external quality assessment scheme. The acceptable difference in nonselectivity is used to modify the prediction interval criterion for commutability assessment. The present report provides recommendations on how to establish a criterion for acceptable commutability for EQAMS, establish the difference in nonselectivity that can be accepted between IVD-MDs, and perform a commutability assessment. The report also contains examples for performing a commutability assessment of EQAMs.


Asunto(s)
Servicios de Laboratorio Clínico , Ensayos de Aptitud de Laboratorios , Humanos , Estándares de Referencia , Juego de Reactivos para Diagnóstico
18.
Clin Chim Acta ; 550: 117564, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37748747

RESUMEN

BACKGROUND AND AIMS: The monitoring of yearly distributions of HbA2 measured has been indicated as a reliable indicator of worldwide standardization. MATERIALS AND METHODS: Measurements/year of HbA2 have been collected over three consecutive years in 15 Italian laboratories each using the same analytical method over three years period. HbA2 distributions, cleaned of replicated measurements, were compared by the overlapping area of the raw probability density functions expressed by coefficient eta (η), and by comparing the reference intervals for the central part of each distribution estimated by the indirect method refineR using the R package "refineR". RESULTS: According to the overlapping areas analysis the distributions/year of the data provided by 4 centers able to perform at least 1000 measurements/year were similar in 2 consecutive years. Moreover, the reference intervals provided by 2 centers using the same analytical methods in two separate locations over the three consecutive years, were very similar. The highest overlap (99.7 %) was observed in one center over two consecutive years. The overlapping areas were very high (93.6-95.7%) in 8 out of 9 inter-comparisons. CONCLUSION: Despite the limitations of this study the yearly distribution of the HbA2 measured in various centers appears a reliable tool to test HbA2 standardization over different centers using different analytical methods.

19.
Clin Chem ; 69(9): 966-975, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37566391

RESUMEN

A secondary higher-order calibrator is required to be commutable with clinical samples to be suitable for use in the calibration hierarchy of an end-user clinical laboratory in vitro diagnostic medical device (IVD-MD). Commutability is a property of a reference material that means results for a reference material and for clinical samples have the same numeric relationship, within specified limits, across the measurement procedures for which the reference material is intended to be used. Procedures for assessing commutability have been described in the literature. This report provides recommendations for establishing a quantitative criterion to assess the commutability of a certified reference material (CRM). The criterion is the maximum allowable noncommutability bias (MANCB) that allows a CRM to be used as a calibrator in a calibration hierarchy for an IVD-MD without exceeding the maximum allowable combined standard uncertainty for a clinical sample result (umaxCS). Consequently, the MANCB is derived as a fraction of the umaxCS for the measurand. The suitability of an MANCB for practical use in a commutability assessment is determined by estimating the number of measurements of clinical samples and CRMs required based on the precision performance and nonselectivity for the measurand of the measurement procedures in the assessment. Guidance is also provided for evaluating indeterminate commutability conclusions and how to report results of a commutability assessment.

20.
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...