Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Endosc Int Open ; 12(9): E1043-E1055, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39268154

RESUMEN

Background and study aims The Varix Trainer model 1 (VTM1) was created for trainees to safely practice basic endoscope manipulation skills. The VTM1 was tested to see if it could distinguish levels of endoscope manipulation skills (construct validity) and whether training with it could improve these skills faster (content validity). Patients and methods We enrolled 23 novice endoscopists, 18 second-year trainees, and 13 expert endoscopists. They were asked to point with the endoscope tip to 20 numbers in the model as quickly as possible using torque, single-hand small/large wheel manipulation (SHSW), and retroflexion techniques. Their mean times (t20) were compared to determine if the model could distinguish different levels of expertise. Subsequently, 14 novices trained for eight short sessions, and the pre-training and post-training t20 were compared. Nine novice endoscopists received no training and were retested after 4 to 6 weeks (controls). Results Experts had faster t20 than second-year trainees, who were faster than novices, for all three techniques ( P < 0.001). After eight sessions, the mean t20 for novices improved from 112 to 66 seconds for torque, 144 to 72 seconds for SHSW, and 108 to 63 seconds for retroflexion, (all P < 0.001). Their t20 were equivalent to second-year trainees. Improvement in t20 was also seen with the control group, but total reduction was less than for the training group. Conclusions The VTM1 distinguished varying levels of expertise for all techniques, suggesting that it is a valid tool for assessing endoscope manipulation skill. A short curriculum improved novices' manipulation skills faster than traditional practice.

2.
Front Med (Lausanne) ; 11: 1376586, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38721355

RESUMEN

Background and aims: Colonoscopy is an essential cancer screening tool; however, bowel preparation is a multifaceted process that involves several steps. Proper preparation is crucial for a successful colonoscopy in terms of diagnostic accuracy and procedural safety. We evaluated the performance of a smartphone application with bowel preparation instructions on individuals undergoing their first colonoscopy. Methods: In this randomized, prospective, endoscopist-blinded study, participants were scheduled to undergo their first colonoscopy between January 2020 and January 2022. The study protocol was registered at Thai Clinical Trials Registry (TCTR20190928002). They were randomly assigned to the smartphone education application (APP) or the standard education (control) group. The Boston Bowel Preparation Scale (BBPS) score, polyp detection rate (PDR), and adenoma detection rate (ADR) were compared. Factors associated with excellent bowel preparation were also evaluated. Results: In total, 119 patients (APP group, n = 57; control group, n = 62) underwent their first colonoscopy. The mean BBPS score and proportion of excellent bowel preparation (BBPS≥8) were significantly higher in the APP group than in the control group. Smartphone application-guided bowel preparation achieved a higher proportion of adequate and excellent bowel preparation scores, was associated with other quality indicators, and achieved the target ADR, cecal intubation rate, and adequate withdrawal time. Conclusion: This application may be a user-friendly option to improve the first-time colonoscopy experience, resulting in effective screening of colorectal cancer. Clinical trial registration: The study protocol was registered at Thai Clinical Trials Registry (TCTR20190928002).

3.
Sci Rep ; 14(1): 7598, 2024 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-38556533

RESUMEN

Acute upper gastrointestinal hemorrhage (UGIH) is the most common emergency condition that requires rapid endoscopic treatment. This study aimed to evaluate the effects of pre-endoscopic intravenous metoclopramide on endoscopic mucosal visualization (EMV) in patients with acute UGIH. This was a multicenter, randomized, double-blind controlled trial of participants diagnosed with acute UGIH. All participants underwent esophagogastroduodenoscopy within 24 h. Participants were assigned to either the metoclopramide or placebo group. Modified Avgerinos scores were evaluated during endoscopy. In total, 284 out of 300 patients completed the per-protocol procedure. The mean age was 62.8 ± 14.3 years, and 67.6% were men. Metoclopramide group achieved a higher total EMV and gastric body EMV score than the other group (7.34 ± 1.1 vs 6.94 ± 1.6; P = 0.017 and 1.80 ± 0.4 vs 1.64 ± 0.6; P = 0.006, respectively). Success in identifying lesions was not different between the groups (96.5% in metoclopramide and 93.6% in placebo group; P = 0.26). In the metoclopramide group, those with active variceal bleeding compared with the control group demonstrated substantial improvements in gastric EMV (1.83 ± 0.4 vs 1.28 ± 0.8, P = 0.004), antral EMV (1.96 ± 0.2 vs 1.56 ± 0.6, P = 0.003), and total EMV score (7.48 ± 1.1 vs 6.2 ± 2.3, P = 0.02). Pre-endoscopic intravenous metoclopramide improved the quality of EMV in variceal etiologies of UGIH, which was especially prominent in those who had signs of active bleeding based on nasogastric tube assessment.Trial Registration: Trial was registered in Clinical Trials: TCTR 20210708004 (08/07/2021).


Asunto(s)
Várices Esofágicas y Gástricas , Hemorragia Gastrointestinal , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Hemorragia Gastrointestinal/etiología , Metoclopramida/uso terapéutico , Várices Esofágicas y Gástricas/complicaciones , Endoscopía Gastrointestinal/efectos adversos , Administración Intravenosa , Método Doble Ciego
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...