RESUMEN
Purpose: To compare the axial length (AL) and corneal diameter between glaucomatous eye (GE) and fellow normal eye (NE) in patients with unilateral congenital glaucoma and to obtain a normative database for ocular growth among Indian children below 3 years of age. Methods: Retrospective longitudinal study. Patients who had a follow-up of 3 years from diagnosis with ocular biometry parameters being recorded at least thrice (once a year) and fellow eye being normal were included. Data collected were age, gender, intraocular pressure (IOP), AL, corneal diameter, optic disc findings, diagnosis, and surgery details. Results: Eleven patients were analyzed. All GE underwent combined trabeculotomy with trabeculectomy. Mean (SD) baseline IOP, AL, and corneal diameter were 17.1 (6.7) mmHg, 18.9 (1.1) mm and 12 (0.91) mm in GE, and 11.1 (3.8) mmHg, 17.8 (0.44) mm, and 10.5 (0.58) mm in NE, respectively. Increase in AL was 3.1 mm in the first year followed by 0.6 mm in second year and 0.4 mm in third year in GE compared to 2.6, 0.6, and 0.5 mm in NE, respectively. Corneal diameter increased by 1.1 mm in GE in the first year and remained stable thereafter compared to 0.7 mm in first year followed by 0.3 mm in second year and stable thereafter in NE. The percentage of success was 73% at 3 years. Conclusion: Axial length and corneal diameter were higher in GE than NE at all-time points. With prompt intervention, the growth curve of the GE was made parallel to that of NE.
Asunto(s)
Glaucoma , Trabeculectomía , Niño , Humanos , Estudios Retrospectivos , Estudios Longitudinales , Córnea , Glaucoma/diagnóstico , Glaucoma/cirugía , Presión Intraocular , Biometría , Resultado del Tratamiento , Estudios de SeguimientoRESUMEN
Purpose: To find out the mean rate of progression (MROP) of visual fields (VF) in patients with primary open-angle glaucoma (POAG) and ocular hypertension (OHT) using FORUM® Glaucoma Workplace. Methods: Two hundred and one eyes of 105 patients were included in this prospective cohort study. Patients with POAG and OHT were recruited, and VF analysis with 24-2 and or 10-2 was done using SITA standard strategy in Zeiss Humphrey Visual Field Analyzer (HFA). All the previous VFs were identified from FORUM software, and the baseline indices were recorded from the first reliable VF analysis. The present VF analysis was compared to the previous one using FORUM software, and the rate of progression (ROP) in VF was obtained by Guided Progression Analysis. Results: MROP of VF in the POAG group was - 0.085 dB/year, ranging from -2.8 to 2.8 dB/year with a standard deviation (SD) of 0.69. In the OHT group, the MROP of VF was -0.003 dB/year, ranging from - 0.8 to 0.5 dB/year with an SD of 0.27. The MROP of VF in medically treated eyes with POAG was -0.14 dB/year with an SD of 0.61 and in surgically treated eyes was -0.02 dB/year with an SD of 0.78. The overall baseline mean VF index (VFI) was 83.19% and the final mean VFI was 79.80%. There was a statistically significant decrease in the mean VFI value from baseline to the final visit (P-value 0.0005). Conclusion: The mean ROP of VF in the POAG group was -0.085 dB/year and in the OHT group was - 0.003 dB/year.
Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Hipertensión Ocular , Humanos , Campos Visuales , Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Ángulo Abierto/cirugía , Presión Intraocular , Estudios Prospectivos , Centros de Atención Terciaria , Trastornos de la Visión , Hipertensión Ocular/diagnóstico , Hipertensión Ocular/epidemiología , Pruebas del Campo Visual , Lugar de Trabajo , Progresión de la EnfermedadRESUMEN
This case report discusses anterior capsular phimosis in a patient without the typical risk factors for anterior capsule contraction syndrome.
Asunto(s)
Oftalmopatías , Cápsula del Cristalino , Lentes Intraoculares , Facoemulsificación , Fimosis , Masculino , Humanos , Oftalmopatías/etiología , Factores de Riesgo , Fimosis/complicaciones , Capsulorrexis/efectos adversos , Lentes Intraoculares/efectos adversos , Facoemulsificación/efectos adversos , Complicaciones PosoperatoriasAsunto(s)
Ojo , Manitol , Humanos , Manitol/efectos adversos , Estudios Prospectivos , Presión Intraocular , Biometría , Vitrectomía , Estudios RetrospectivosRESUMEN
Purpose: This study was conducted to assess the outcomes of bleb needling for the treatment of failure of filtration surgeries in primary glaucoma with a follow-up of six months. Methods: This prospective interventional study included patients with primary glaucoma who underwent trabeculectomy or combined glaucoma and cataract surgery with failed or failing bleb after six weeks of surgery and less than two years. A comprehensive examination including best-corrected visual acuity (BCVA), intraocular pressure (IOP) measurement, gonioscopy, slit-lamp examination, and bleb morphology grading was done. Selected patients underwent a subconjunctival bleb needling with mitomycin C (MMC) (dose 0.2 mg/ml). Postoperatively, patients were followed up on the first, third, and sixth months and were assessed with respect to IOP, need for antiglaucoma medication (AGM), and complications. Results: Sixty eyes of 59 patients were included. Preoperatively, 33.3% of patients were on one AGM, whereas postoperatively at the third month 51.7% and at the sixth month 50% of patients were on no AGM. There was a statistically significant decrease in IOP (P < 0.001) from preoperative (mean: 23.8 ± 7.86 mmHg) to postoperative first month (mean: 19.8 ± 9.08 mmHg), third month (mean: 17.4 ± 5.4 mmHg) and sixth month (mean 16.6 ± 4.39). According to the defined criteria in the current study, we achieved 22 (37.9%) successes, 31 qualified successes (53.4%), and 5 (8.6%) failures. Univariate regression analysis showed a higher failure rate among younger age groups. Gender, laterality, and intraoperative complications were not significant statistically. Conclusion: Bleb needling is a safe and effective procedure for the treatment of failed filtration surgeries.
Asunto(s)
Cirugía Filtrante , Glaucoma , Humanos , Pueblo Asiatico , Glaucoma/cirugía , Estudios ProspectivosRESUMEN
Neuroprotective therapies in glaucoma may play a role in preventing ischemia and oxidative damage that results in apoptosis of retinal ganglion cells and optic nerve damage. Although intraocular pressure (IOP) is the only known modifiable risk factor for glaucoma, disease progression commonly occurs despite IOP control, suggesting that factors other than IOP play a role in its pathogenesis and can potentially act as targets for neuroprotection. Factors including mediators of apoptosis, ischemic changes, poor ocular blood flow and neurotoxins have been hypothesized to play a role in glaucoma progression. Neuroprotective targets include glutamate-induced neurotoxicity, nitric oxidase synthetase, neurotropins, calcium channel receptors, free radicals, vascular insufficiency, the rho-kinase pathway, and more. Drugs related to these factors are being evaluated for their role in neuroprotection, although this area of investigation faces several challenges including limited evidence for these agents' efficacy in clinical studies. Additionally, while IOP-lowering therapies are considered neuroprotective as they generally slow the progress of glaucoma progression, they are limited by the extent of their effect beyond IOP control. The aim of this article is to review the current treatment options available for neuroprotection and to explore the drugs in the pipeline.
Asunto(s)
Glaucoma , Fármacos Neuroprotectores , Humanos , Presión Intraocular , Neuroprotección/fisiología , Fármacos Neuroprotectores/metabolismo , Fármacos Neuroprotectores/farmacología , Fármacos Neuroprotectores/uso terapéutico , Células Ganglionares de la Retina/patologíaAsunto(s)
Presión Intraocular , Manitol , Humanos , Estudios Prospectivos , Tonometría Ocular , VitrectomíaAsunto(s)
Glaucoma , Presión Intraocular , Adulto , Glaucoma/diagnóstico , Glaucoma/epidemiología , Hospitales , Humanos , Tonometría OcularRESUMEN
Purpose: To assess the quality and accuracy of glaucoma referrals from ophthalmologist. Methods: Retrospective review of patients chart with referral letter to a tertiary glaucoma center between January and December 2017. Patients aged <16 years, lens-induced glaucoma, uveitic glaucoma, and glaucoma following retinal and corneal surgery were excluded. Results: A total of 184 patients referred by 55 ophthalmologists were included. Mean patient age (SD) was 57.8 ± 14 years. Intraocular pressure was not documented in the referral letter in 113 (61%) patients, gonioscopy in 174 (95%) patients, disc findings in 149 (81%) patients, and visual fields in 175 (95%) patients. Thirteen (37%) of the 35 patients referred as open angle glaucoma were found to have angle closure glaucoma. Pseudoexfoliation glaucoma was diagnosed in 29 (16%) patients, of which 18 were missed by the referring ophthalmologist. Conclusion: In our study >90% of referral letter did not have the essential parameters. A standard template for glaucoma referral is suggested, which will help the patient to get better transfer of care.
Asunto(s)
Glaucoma/diagnóstico , Gonioscopía/métodos , Presión Intraocular/fisiología , Indicadores de Calidad de la Atención de Salud , Derivación y Consulta , Centros de Atención Terciaria , Campos Visuales/fisiología , Femenino , Estudios de Seguimiento , Glaucoma/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Tonometría Ocular/métodosRESUMEN
OBJECTIVES: To assess the ability of teleophthalmoscopic grading of peripheral anterior chamber depth (PACD) using the van Herick (vH) technique in detecting gonioscopically occludable angle; and to determine whether combining results from vH grading and ocular biometry can improve the accuracy to diagnose gonioscopically occludable angle METHODS: This cross-sectional study was an offshoot of a rural population-based study, Glaucoma Epidemiology and Molecular Genetic Study (GLEAMS). A masked urban ophthalmologist graded digital slit lamp photographs of PACD by vH technique. Sussman four-mirror lens was used to perform dark room indentation gonioscopy. Cutoff values of the tests were, vH technique: grade ≤ 2, central anterior chamber depth (ACD), as well as axial length: ≤ 25th percentile and lens thickness ≥ 75th percentile value of the study population. RESULTS: We studied 1965 eyes of 1029 adult participants. The vH grade was ≤2 in 188 (9.5%) eyes. The angle was occludable by gonioscopy in 101 (5.1%) eyes. The performance of the vH test to rule out gonioscopically occludable angle was good [negative predictive value (NPV): 97.3%], despite low sensitivity (52.5%), while its efficacy to rule in the condition was low [positive predictive value (PPV): 28.2%] despite high specificity (92.8%). However, test combination strategy increased the PPV nearly twofold (53.8%). The calculated PPV at 10% prevalence of gonioscopically occludable angle was even higher (70.5%). CONCLUSIONS: Van Herick technique can be incorporated into a teleophthalmology program by means of slit lamp photographs of PACD. Combined vH grading and ocular biometry improved the predictability of a gonioscopically occludable angle.