Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
2.
Front Cell Infect Microbiol ; 13: 1183340, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37502605

RESUMEN

Introduction: The diagnosis of cutaneous manifestations of deep mycoses relies on both histopathological and direct examinations. Yet, the current diagnostic criteria cannot prevent missed cases, including invasive aspergillosis, which requires the development of a novel diagnostic approach and imaging tools. We recently introduced the use of dynamic full-field optical coherence tomography (D-FF-OCT) in fungal diagnostics with a definition approaching that of conventional microscopy and the ability to return metabolic information regarding different fungal species. The present work focuses on subcellular dynamics and live-cell imaging of Aspergillus fumigatus with D-FF-OCT to follow the fungal growth stages. Methods: The A. fumigatus ATCC 204305 quality-control strain was used for all imaging experiments, following incubation times varying between 24 and 72 h at 30°C in a humidified chamber on Sabouraud dextrose agar. Fungal growth was subsequently monitored with D-FF-OCT for up to 5 h at room temperature and following the pharmacological stress of either voriconazole, amphotericin B, or caspofungin gradient concentration. Results: D-FF-OCT images allow not only the visualization of intracellular trafficking of vacuoles but also an evolving dynamic segmentation of conidiophores depending on the chronological development and aging of the hyphae or the effect of antifungal treatment. The same applies to conidial heads, with the most intense D-FF-OCT signal coming from vesicles, revealing a changing dynamic within a few hours only, as well as complete extinction following subsequent drying of the Sabouraud dextrose agar. Discussion: These results provide additional data on the ability of D-FF-OCT to monitor some of the main life cycle processes, dynamics, and intracellular trafficking of vacuoles in A. fumigatus, with or without the effect of pharmacological stress. Such complementary metabolic information could help both clinicians and microbiologists in either mechanistic studies toward experimental mycology or the development of a potential D-FF-OCT-guided diagnosis of superficial fungal infections.


Asunto(s)
Aspergillus fumigatus , Tomografía de Coherencia Óptica , Agar/farmacología , Antifúngicos/farmacología , Glucosa
3.
J Mycol Med ; 32(4): 101303, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35732095

RESUMEN

Histopathology and microscopic examination of infected tissue are the gold standards to prove the diagnosis of invasive fungal infection (IFI). Yet, they suffer from essential limitations that hamper rapid diagnosis and require the future development of new imaging tools dedicated to fungal diagnostics. To this end, the present work introduces the first use of dynamic full-field optical coherence tomography (D-FF-OCT) for the visualization of microscopic filamentous fungi. Data collected from the observation of three different fungal species (Nannizzia gypsea, Aspergillus fumigatus and Rhizopus arrhizus) confirm the ability of D-FF-OCT to visualize not only the main structures of all selected fungal species (hyphae, spores, conidia, sporulating structures), but also the metabolic activity of the organisms, which could provide additional help in the future to better characterize the signature of each fungal structure. These results demonstrate how D-FF-OCT could serve as potential complementary tool for rapid diagnosis of IFI in both intensive and non-intensive care units.


Asunto(s)
Aspergillus fumigatus , Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Esporas Fúngicas , Hongos
4.
Opt Express ; 29(14): 22044-22065, 2021 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-34265978

RESUMEN

We report on a theoretical model for image formation in full-field optical coherence tomography (FFOCT). Because the spatial incoherence of the illumination acts as a virtual confocal pinhole in FFOCT, its imaging performance is equivalent to a scanning time-gated coherent confocal microscope. In agreement with optical experiments enabling a precise control of aberrations, FFOCT is shown to have nearly twice the resolution of standard imaging at moderate aberration level. Beyond a rigorous study on the sensitivity of FFOCT with respect to aberrations, this theoretical model paves the way towards an optimized design of adaptive optics and computational tools for high-resolution and deep imaging of biological tissues.


Asunto(s)
Modelos Teóricos , Óptica y Fotónica , Tomografía de Coherencia Óptica/métodos , Humanos , Microscopía Confocal/métodos
5.
PLoS One ; 15(8): e0234165, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32866179

RESUMEN

Histopathological examination of temporal artery biopsy (TAB) remains the gold standard for the diagnosis of giant cell arteritis (GCA) but is associated with essential limitations that emphasize the need for an upgraded pathological process. This study pioneered the use of full-field optical coherence tomography (FF-OCT) for rapid and automated on-site pathological diagnosis of GCA. Sixteen TABs (12 negative and 4 positive for GCA) were selected according to major histopathological criteria of GCA following hematoxylin-eosin-saffron-staining for subsequent acquisition with FF-OCT to compare structural modifications of the artery cell wall and thickness of each tunica. Gabor filtering of FF-OCT images was then used to compute TAB orientation maps and validate a potential automated analysis of TAB sections. FF-OCT allowed both qualitative and quantitative visualization of the main structures of the temporal artery wall, from the internal elastic lamina to the vasa vasorum and red blood cells, unveiling a significant correlation with conventional histology. FF-OCT imaging of GCA TABs revealed destruction of the media with distinct remodeling of the whole arterial wall into a denser reticular fibrous neo-intima, which is distinctive of GCA pathogenesis and accessible through automated Gabor filtering. Rapid on-site FF-OCT TAB acquisition makes it possible to identify some characteristic pathological lesions of GCA within a few minutes, paving the way for potential machine intelligence-based or even non-invasive diagnosis of GCA.


Asunto(s)
Arteritis de Células Gigantes/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Estudios de Cohortes , Femenino , Arteritis de Células Gigantes/diagnóstico , Arteritis de Células Gigantes/patología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Arterias Temporales/diagnóstico por imagen , Arterias Temporales/patología , Túnica Íntima/diagnóstico por imagen , Túnica Íntima/patología , Túnica Media/diagnóstico por imagen , Túnica Media/patología
6.
Proc Natl Acad Sci U S A ; 117(22): 11947-11953, 2020 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-32424103

RESUMEN

Living tissues, heterogeneous at the microscale, usually scatter light. Strong scattering is responsible for the whiteness of bones, teeth, and brain and is known to limit severely the performances of biomedical optical imaging. Transparency is also found within collagen-based extracellular tissues such as decalcified ivory, fish scales, or cornea. However, its physical origin is still poorly understood. Here, we unveil the presence of a gap of transparency in scattering fibrillar collagen matrices within a narrow range of concentration in the phase diagram. This precholesteric phase presents a three-dimensional (3D) orientational order biomimetic of that in natural tissues. By quantitatively studying the relation between the 3D fibrillar network and the optical and mechanical properties of the macroscopic matrices, we show that transparency results from structural partial order inhibiting light scattering, while preserving mechanical stability, stiffness, and nonlinearity. The striking similarities between synthetic and natural materials provide insights for better understanding the occurring transparency.


Asunto(s)
Materiales Biomiméticos , Colágenos Fibrilares , Animales , Materiales Biomiméticos/síntesis química , Materiales Biomiméticos/química , Biomimética/métodos , Córnea/química , Colágenos Fibrilares/síntesis química , Colágenos Fibrilares/química
7.
J Biomed Opt ; 20(5): 56004, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25970085

RESUMEN

Photoacoustic imaging can achieve high-resolution three-dimensional (3-D) visualization of optical absorbers at penetration depths of ∼1 cm in biological tissues by detecting optically induced high ultrasound frequencies. Tomographic acquisition with ultrasound linear arrays offers an easy implementation of single-side access, parallelized, and high-frequency detection, but usually comes with an image quality impaired by the directionality of the detectors. Indeed, a simple translation of the array perpendicular to its median imaging plane is often used, but results both in a poor resolution in the translation direction and strong limited-view artifacts.To improve the spatial resolution and the visibility of complex structures while retaining a planar detection geometry, we introduce, in this paper, a rotate-translate scanning scheme and investigate the performance ofa scanner implemented at 15 MHz center frequency. The developed system achieved a quasi-isotropic uniform 3-D resolution of ∼170 µm over a cubic volume of side length 8.5 mm, i.e., an improvement in the resolution in the translation direction by almost one order of magnitude. Dual-wavelength imaging was also demonstrated with ultrafast wavelength shifting. The validity of our approach was shown in vitro. We discuss the ability to enable in vivo imaging for preclinical and clinical studies.


Asunto(s)
Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Imagenología Tridimensional/instrumentación , Técnicas Fotoacústicas/instrumentación , Transductores , Ultrasonografía/instrumentación , Anisotropía , Diseño de Equipo , Análisis de Falla de Equipo , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Rayos Láser , Fantasmas de Imagen , Reproducibilidad de los Resultados , Rotación , Sensibilidad y Especificidad
8.
J Biomed Opt ; 18(12): 121514, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24357549

RESUMEN

Elasticity maps of tissue have proved to be particularly useful in providing complementary contrast to ultrasonic imaging, e.g., for cancer diagnosis at the millimeter scale. Optical coherence tomography (OCT) offers an endogenous contrast based on singly backscattered optical waves. Adding complementary contrast to OCT images by recording elasticity maps could also be valuable in improving OCT-based diagnosis at the microscopic scale. Static elastography has been successfully coupled with full-field OCT (FF-OCT) in order to realize both micrometer-scale sectioning and elasticity maps. Nevertheless, static elastography presents a number of drawbacks, mainly when stiffness quantification is required. Here, we describe the combination of two methods: transient elastography, based on speed measurements of shear waves induced by ultrasonic radiation forces, and FF-OCT, an en face OCT approach using an incoherent light source. The use of an ultrafast ultrasonic scanner and an ultrafast camera working at 10,000 to 30,000 images/s made it possible to follow shear wave propagation with both modalities. As expected, FF-OCT is found to be much more sensitive than ultrafast ultrasound to tiny shear vibrations (a few nanometers and micrometers, respectively). Stiffness assessed in gel phantoms and an ex vivo rat brain by FF-OCT is found to be in good agreement with ultrasound shear wave elastography.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Elasticidad/fisiología , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía de Coherencia Óptica/métodos , Animales , Encéfalo/fisiología , Diagnóstico por Imagen de Elasticidad/instrumentación , Fantasmas de Imagen , Ratas , Tomografía de Coherencia Óptica/instrumentación
9.
Appl Spectrosc ; 64(8): 853-7, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20719047

RESUMEN

Raman spectroscopy was used to study the NaCl aqueous solutions around the solid-liquid phase transition. Special attention was devoted to the modification induced by the salt on the OH stretching band of water. Investigations were carried out in the temperature range between -21 and 10 degrees C, for concentrations from 0 to 200 g/L. We demonstrated that micro-Raman spectroscopy can be used as a marker, allowing the determination of the salt concentration of an aqueous solution with an error close to +/-5%.


Asunto(s)
Cloruro de Sodio/química , Espectrometría Raman/métodos , Agua/química , Hielo , Concentración Osmolar , Transición de Fase , Reproducibilidad de los Resultados , Temperatura
10.
Sensors (Basel) ; 10(4): 3815-23, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-22319327

RESUMEN

We propose a new optical sensor to characterize the solid-liquid phase transition in salted solutions. The probe mainly consists of a Raman spectrometer that extracts the vibrational properties from the light scattered by the salty medium. The spectrum of the O-H stretching band was shown to be strongly affected by the introduction of NaCl and the temperature change as well. A parameter SD defined as the ratio of the integrated intensities of two parts of this band allows to study the temperature and concentration dependences of the phase transition. Then, an easy and efficient signal processing and the exploitation of a modified Boltzmann equation give information on the phase transition. Validations were done on solutions with varying concentration of NaCl.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...