Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Vasc Specialist Int ; 40: 25, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39014553

RESUMEN

Intravascular foreign body embolization is a potential complication of any vascular operation. Placement of a central venous catheter (CVC) is a common procedure, especially during surgery, hemodialysis, or in critically ill patients. The complete loss of the introducing guidewire into the circulation is a rare complication, with the majority of cases identified immediately or shortly after the procedure. We report an unusual case of an 82-year-old male with a misplaced CVC guidewire, extending from the right common femoral vein (CFV) to the superior vena cava, that was found incidentally 2 years after internal jugular vein cannulation during colorectal surgery. The patient was asymptomatic at the time, without any signs of deep vein thrombosis or post-thrombotic syndrome. Surgical extraction of the guidewire was successfully performed, under local anesthesia, through venotomy of the right CFV. Proper education and advanced awareness are advised in order to minimize the risk of this avoidable complication.

2.
J Endovasc Ther ; : 15266028241261661, 2024 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-38881034

RESUMEN

PURPOSE: The iliac veins are the least frequent location for venous aneurysms, with only a few cases described globally. The etiology and clinical presentation of this extremely rare entity is diverse and unclear and no treatment consensus has been reached yet. Our purpose is to present an interesting iliac vein aneurysm (IVA) case that we treated in our department, with a brief review of the literature. CASE REPORT: We report a case of a 74-year-old male patient with a giant, 55 mm in diameter, asymptomatic, right common IVA, with concurrent aplasia of the left common iliac vein and an extensive network of venous collaterals. The patient was treated, under general anesthesia, with total endovascular iliocaval reconstruction through implantation of a 32 × 100 mm thoracic aortic tubular Ankura stent graft. The computed tomography venography at first-month follow-up showed the complete exclusion of the IVA, without any endoleak and the patient remains up to date free of symptoms and thromboembolic events. CONCLUSION: Twelve cases of endovascular treatment of IVA have been reported so far, and our case is the first with implantation of a thoracic aortic stent graft. Our results suggest that this technique is safe, effective, and may be considered for appropriately selected patients. CLINICAL IMPACT: This is the first case with total endovascular repair of an iliac vein aneurysm with contralateral iliac vein aplasia through endovenous implantation of a thoracic aortic stent-graft. Our results suggest that this technique is safe and effective and thus, may be considered for appropriately selected cases.

3.
Vasc Specialist Int ; 40: 12, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38661144

RESUMEN

Purpose: This study aims to investigate whether routine screening for silent pulmonary embolism (PE) can be justified in patients with deep vein thrombosis (DVT). Materials and Methods: We retrospectively analyzed the medical records of 201 patients with lower-extremity DVT admitted to the vascular surgery department of a single tertiary university center between 2019 and 2023. All patients underwent clinical evaluation, basic laboratory exams, a whole-leg colored duplex ultrasound, and a computed tomography pulmonary angiography (CTPA), to screen for an occult, underlying PE. Results: The overall incidence of silent PE was 48.8%. The median admission D-dimer level was significantly higher in patients with silent PE than in those without PE (9.60 vs. 5.51 mg/L, P=0.001). A D-dimer value ≥5.14 mg/L was discriminant for predicting silent PE, with a sensitivity of 68.2% and a specificity of 59.3%. Silent PE was significantly more common on the right side, with the embolus located at the main pulmonary, lobar, segmental, and subsegmental arteries in 29.6%, 32.7%, 20.4%, and 17.3%, respectively. A higher incidence of occult PE was observed in patients with iliofemoral DVT (P=0.037), particularly when the thrombus extended to the inferior vena cava (P=0.003). Moreover, iliofemoral DVT was associated with a larger size and a more proximal location of the embolus (P=0.041). Multivariate logistic regression showed that male sex (odds ratio [OR]=2.46, 95% confidence interval [CI]: 1.39-3.53; P=0.026), cancer (OR=2.76, 95% CI: 1.45-4.07; P=0.017), previous venous thromboembolism (VTE) history (OR=2.67, 95% CI: 1.33-4.01; P=0.022), D-dimer value ≥5.14 mg/L (OR=2.24, 95% CI: 1.10-3.38; P=0.033), iliofemoral DVT (OR=2.13, 95% CI: 1.19-3.07; P=0.041), and thrombus extension to the IVC (OR=2.95, 95% CI: 1.43-4.47; P=0.009) served as independent predictors for silent PE. Conclusion: A high incidence of silent PE was observed in patients with lower-extremity DVT. Screening of patients with DVT who have the aforementioned predictive risk factors using CTPA for silent PE may be needed and justified for the efficient management of VTE and its long-term complications.

4.
Vasc Specialist Int ; 39: 39, 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-38044693

RESUMEN

Endovascular aortic aneurysm sealing (EVAS) with the Nellix endograft was initially considered a groundbreaking and acceptable alternative to conventional endovascular aortic aneurysm repair, with encouraging initial results. However, long-term follow-up has revealed a high incidence of endograft-related complications, such as caudal migration and type Ia endoleaks, indicating the need for reintervention. Managing failed EVAS remains challenging and is an ongoing topic of discussion, especially for high-risk patients. We describe a 70-year-old female who initially underwent EVAS with a Nellix endograft and presented after 5 years of follow-up with caudal endograft migration and a type Ia endoleak. The patient was treated with endovascular implantation of an Altura stent-graft, a relatively new low-profile device with a similar double stent configuration. Device migration and endoleaks were undetectable at 12 months of follow-up, suggesting that the Altura might offer a safe and efficient approach in cases of Nellix proximal failure.

5.
J Endovasc Ther ; : 15266028231172379, 2023 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-37166154

RESUMEN

PURPOSE: A variety of last-generation endografts are currently available for standard endovascular repair (EVAR) of infrarenal abdominal aortic aneurysms (AAAs). The purpose of this study is to report the preliminary clinical outcomes of the Minos trimodular stent-graft system, which was recently introduced to the European market. MATERIALS AND METHODS: Between February 2020 and 2022, we treated 41 consecutive AAA patients (mean age 72.2±8.5, 37 males) with elective standard EVAR using the Minos. The mean maximum diameter of AAAs was 54.7±6.6 mm, the mean proximal neck's (PN) diameter was 24.8±2.7 mm, while the relevant length and angulation were 16.0 mm and 21.7°, respectively. Overall, 22 (53.6%) patients presented with shorter and angulated PN, according to the stent-graft's instructions of use, and in 6 (14.6%) patients the PN angulation >60° was combined with concomitant iliac angulation >60°. Eleven (26.8%) EVARs were performed with concomitant enormous iliac artery narrowing and tortuosity. Finally, in 19 (46.3%) AAAs, the distal iliac landing zone was aneurysmatic and they were treated with the bell-bottom technique in 17 patients and with limb extension to the external iliac artery in two cases. We evaluated technical and clinical success of the index procedures, which was based on the combination of five factors: freedom from EVAR-related mortality, from graft-related endoleak of any type, from migration at any part of graft as well the absence of notable increase AAA's sac maximum diameter and the patency of bifurcated stent-graft and of access vessels. RESULTS: Primary technical and clinical success of index procedures was 100%. During a median 12-month radiological follow-up the clinical success remained 100%. No type I or III endoleak, stent-graft migration, EVAR-related death, AAA rupture, or graft-related adverse events or reinterventions were documented. Four (9.8%) type II endoleaks were detected with stable AAA sac diameter. The overall incidence of sac regression was 34.1% (n=14). CONCLUSION: The preliminary results of our series showed that Minos provided excellent feasibility and safety features even through angulated and tortuous iliac vessels and in short and angulated PNs. The overall clinical success at 1 year suggests that performance of Minos follows very high standards. Further validation of these promising results with long-term data is acquired to complete the evaluation of this recently introduced stent-graft system. CLINICAL IMPACT: The current study explored the clinical performance of a new in market ultra-low profile bifurcated abdominal aortic stent-graft, the MINOS. The early and 12-month results of study suggest that implantation of this stent-graft in standard EVAR, even in hostile proximal aortic neck and iliac vessels conditions, follows very high clinical standards and encourage the further clinical use of MINOS.

6.
J Endovasc Ther ; : 15266028231167998, 2023 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-37078515

RESUMEN

PURPOSE: To measure the long-term proximal aortic neck dilatation (AND) after elective endovascular aortic aneurysm repair (EVAR) with a variety of contemporary, third-generation, endograft devices. MATERIALS AND METHODS: This is a noninterventional prospective cohort study of 157 patients that underwent standard EVAR with self-expanding abdominal endografts. Patients' recruitment lasted from 2013 to 2017, and postoperative follow-up was up to 5 years. A computed tomography angiography (CTA) was performed at the first month and then at 1, 2, and 5 years. Proximal aortic neck's (PAN) basic morphological characteristics (diameter, length, angulation) were measured based on the analysis of CTA in a standardized fashion. Neck-related adverse events, such as migration, endoleak or rupture, and reinterventions were recorded. RESULTS: Significant straightening of the PAN was evident even in the first-month CTA with concurrent neck shortening that became significant at 5 years. Both the suprarenal aorta and the PAN significantly dilated overtime, with PAN dilating more progressively. Mean neck dilatation at the juxtarenal level was 0.8±0.4 mm at 1 year, 1.8±0.8 mm at 2 years, and 3.9±1.7 mm at 5 years, with a mean neck dilatation rate of 0.07 mm/month overall. The incidence of AND ≥2.5 mm was 37.2% at 2 years and 58.1% at 5 years after EVAR and was considered important (≥5 mm) in 11.5% of patients at 2 years and 30.6% of patients at 5 years. A multivariate analysis performed showed that the endograft oversizing, the preoperative neck diameter, and the preoperative abdominal aortic aneurysm sac diameter served as independent predictors of AND at 5 years. At the 5-year follow-up, 8 late type Ia endoleaks (6.5%) and 7 caudal migrations (5.6%) were identified, while no late ruptures were reported. In total, 11 late endovascular reinterventions (8.9%) were performed. Overall, proximal neck-related adverse outcomes (5/7 migrations and 5/8 endoleaks) and reinterventions (7/11) were significantly associated with the presence of important late AND. CONCLUSION: Proximal AND after EVAR is common. It can influence the long-term durability of proximal endograft fixation and is significantly associated with adverse outcomes, often leading to reinterventions. A systemic and extended surveillance protocol is needed for maintenance of good long-term results. CLINICAL IMPACT: This is a thorough and systematic analysis of the long-term geometric remodeling of the proximal aortic neck after EVAR, that highlights the importance of a strict, and extended surveillance protocol for maintenance of good long-term results of EVAR.

7.
J Vasc Surg ; 77(3): 941-956.e1, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-35948244

RESUMEN

OBJECTIVE: To provide an updated systematic literature review summarizing current evidence on aortic neck dilatation (AND) after endovascular aortic aneurysm repair (EVAR) in patients with infrarenal abdominal aortic aneurysm. METHODS: An extensive electronic search in major electronic databases was conducted between January 2000 and December 2021. Eligible for inclusion were observational studies that followed up with patients (n ≥ 20) undergoing EVAR with self-expanding endografts, for 12 or more months, evaluated AND with computed tomography angiography and provided data on relevant outcomes. The primary end point was the incidence of AND after EVAR, and the secondary end points were the occurrence of type Ia endoleak, stent graft migration, secondary rupture, and reintervention. RESULTS: We included 34 studies with a total sample of 12,038 patients (10,413 men; median age, 71 years). AND was defined clearly in 18 studies, but significant differences in AND definition were evidenced. The pooled incidence of AND based on quantitative analysis of 16 studies with a total of 9201 patients (7961 men; median age, 72 years) was calculated at 22.9% (95% confidence interval [CI], 14.4-34.4) over a follow-up period ranging from 12 months to 14 years. The risk of a type Ia endoleak was significantly higher in AND patients compared with those without AND (odds ratio, 2.95; 95% CI, 1.10-7.93; P = .030). Similarly, endograft migration was more common in the AND group compared with the non-AND group (odds ratio, 5.95; 95% CI, 1.80-19.69; P = .004). The combined incidence of secondary rupture and reintervention did not differ significantly between the two groups, even though the combined effect was in favor of the non-AND group. CONCLUSIONS: Proximal AND after EVAR is common and occurs in a large proportion of patients with infrarenal abdominal aortic aneurysm. AND can influence the long-term durability of proximal endograft fixation and is significantly related to adverse outcomes, often leading to reinterventions.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Anciano , Implantación de Prótesis Vascular/efectos adversos , Endofuga/etiología , Resultado del Tratamiento , Dilatación/efectos adversos , Factores de Riesgo , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Aneurisma de la Aorta Abdominal/cirugía , Prótesis Vascular/efectos adversos
8.
Vasc Specialist Int ; 38: 13, 2022 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-35712874

RESUMEN

Renal artery aneurysms (RAAs) are rare lesions with a prevalence of less than 1% in the general population. Renal arteriovenous malformations (AVMs) are rare lesions with an estimated incidence of less than 0.04%. The coexistence of these two clinical entities is extremely rare and narrows the available treatment options by endovascular or open surgery. We describe a case of a giant symptomatic RAA type III, which was combined with a high-flow renal AVM in the right kidney. Using two vascular plugs, the RAA was excluded successfully. The perfusion of the right kidney's lower pole was preserved by implantation of two covered stents in the inferior segmental renal artery.

9.
Int Angiol ; 41(3): 196-204, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35138072

RESUMEN

BACKGROUND: Postimplantation syndrome (PIS) represents an acute phase systemic inflammatory response following endovascular aortic aneurysm repair (EVAR). Our objective was to investigate the risk factors associated with the manifestation and severity of PIS with various available stent-grafts. METHODS: We performed a retrospective analysis of prospectively collected data covering the period 2016-2020. The study included 191 patients. Body temperature was recorded regularly and blood sample was obtained daily. The imaging protocol included computed tomography aortoiliac angiography before surgery and one month after. The volumes of pre-existing and new-onset mural thrombus were calculated in a semi-automated fashion. Five abdominal aortic stent-graft devices were used: Endurant™ ΙΙ, Anaconda™, Treo®, E-tegra® and AFX® 2. Subgroup analysis was performed between woven polyester and ePTFE lined devices. RESULTS: The incidence of PIS was 21.5%. No significant differences were observed regarding demographics, risk factors, aneurysm anatomy or operative data. The amount of pre-existing and new-onset mural thrombus were not related with PIS (P=0.117 and P=0.096). PIS incidence in the polyester subgroup was 24.2%, significantly higher compared to 8.3% in the ePTFE subgroup. In-subgroup analysis revealed that the use of Anaconda™ was associated with the higher frequency (61.1%, P=0.021). Multivariate logistic regression showed that polyester was the single factor significantly associated with PIS (hazard ratio=2.6, P=0.043), as opposed to the new onset thrombus (hazard ratio=1.29, P=0.101). CONCLUSIONS: PIS is not uncommon and should be taken into consideration in patients presenting with fever after EVAR. The endograft's liner material seems to play the primordial role, with woven polyester to be attributed with significantly higher incidence.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Trombosis , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Incidencia , Poliésteres , Estudios Retrospectivos , Factores de Riesgo , Stents/efectos adversos , Síndrome , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...