Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Front Immunol ; 13: 975926, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36189243

RESUMEN

Immune dysfunction has been proposed as a factor that may contribute to disease progression. Emerging evidence suggests that immunotherapy aims to abolish cancer progression by modulating the balance of the tumor microenvironment. 4-1BB (also known as CD137 and TNFRS9), a member of tumor necrosis factor receptor superfamily, has been validated as an extremely attractive and promising target for immunotherapy due to the upregulated expression in the tumor environment and its involvement in tumor progression. More importantly, 4-1BB-based immunotherapy approaches have manifested powerful antitumor effects in clinical trials targeting 4-1BB alone or in combination with other immune checkpoints. In this review, we will summarize the structure and expression of 4-1BB and its ligand, discuss the role of 4-1BB in the microenvironment and tumor progression, and update the development of drugs targeting 4-1BB. The purpose of the review is to furnish a comprehensive overview of the potential of 4-1BB as an immunotherapeutic target and to discuss recent advances and prospects for 4-1BB in cancer therapy.


Asunto(s)
Inmunoterapia , Neoplasias , Miembro 9 de la Superfamilia de Receptores de Factores de Necrosis Tumoral/inmunología , Humanos , Ligandos , Receptores del Factor de Necrosis Tumoral , Microambiente Tumoral
3.
Zhongguo Gu Shang ; 28(12): 1102-5, 2015 Dec.
Artículo en Chino | MEDLINE | ID: mdl-26911116

RESUMEN

OBJECTIVE: To investigate surgical outcomes of strip nail internal fixation with bone graft in treating tibial plateau fracture. METHODS: From May 2012 to May 2014,36 patients with tibial plateau fracture were retrospectively analyzed, including 25 males and 11 females with an average age of 43.5 (ranged from 17 to 65) years old. The time from injury to operation ranged from 3 to 10 days with an average of 5.8 days. All patients were treated with L-shaped and T-shaped strip nail internal fixation with bone graft. It was evaluated by the Knee Functional therapy assessment method of the Special Surgical Hospital of American at final following-up. Varus angle, caster angle and femorotibial angle were recorded and compared at 3 days and 1 year. RESULTS: Operative time was (2.2 ± 0.6) h on average, blood loss was (310.5 ± 36.2) ml on average, hospital stay was (14.8 ± 2.7) days on average. Thirty-six patients were followed up from 12 to 30 months with an average of 18.2 months. Fracture healing time ranged from 4 to 8 months with an average of 6.2 months. The difference is not significant among varus angle, caster angle and femorotibial angle at 3 days and 1 year. According to the knee functional therapy assessment method of the Specialized Surgical Hospital of American, 18 cases got excellent results, 13 good, 4 moderate and 1 poor. CONCLUSION: Strip nail internal fixation with bone graft for the treatment of tibial plateau fracture could effectively prevent the joint surface from secondary collapse, and achieve anatomic reduction, stable fixation and earlier functional exercise in further to get satisfied clinical effects.


Asunto(s)
Clavos Ortopédicos , Trasplante Óseo , Fijación Interna de Fracturas/métodos , Fracturas de la Tibia/cirugía , Adolescente , Adulto , Anciano , Femenino , Curación de Fractura , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Fracturas de la Tibia/fisiopatología
4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(9): 2343-7, 2013 Sep.
Artículo en Chino | MEDLINE | ID: mdl-24369628

RESUMEN

Measurement errors in frequency domain always appear when testing samples' terahertz (THz) absorption spectrum using terahertz time-domain spectroscopy (THz-TDS) system, which is supposed to be attributed to the sampling accuracy of the high speed electro-optic sampling system In order to make the measurement have a high accuracy, the method of error correction was studied in the present article. Carbon monoxide in gas phase was employed as our standard sample, and its absorption spectrum at the pressure of 2.0 x 10(5) Pa was measured experimentally. Comparing the obtained absorption frequencies with the corresponding standard data in JPL database, we got the error values, and their distribution law shows that the values have a linear correlation with the standard absorption frequency. Based on this, the error correction model was built. Using the model to correct the experimental data, the result shows the maximum error after correction is reduced to 3.36 GHz, which is two orders of magnitude lower than the error before correction. This states that the model can be used to correct the error of the THz spectrum caused by high speed electro-optic sampling system. At last, the authors draw a conclusion that the THz-TDS system is supposed to be corrected by the terahertz spectrum of carbon monoxide before measurement, in this way, the terahertz spectrum of sample can have a high accuracy. The study contributes to the material identification and the construction of molecular spectroscopy database in THz region.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA