Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Ophthalmol Sci ; 4(5): 100526, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38840780

RESUMEN

Purpose: Marfan syndrome (MFS) is a connective tissue disorder caused by mutations in the fibrillin-1 ( (FBN1). In addition to typical phenotypes such as ectopia lentis (EL) and aortic dilation, patients with MFS are prone to ocular posterior segment abnormalities, including retinal detachment (RD), maculopathy, and posterior staphyloma (PS). This study aims to investigate the correlations between FBN1 genotype and posterior segment abnormalities within a Chinese cohort of MFS. Design: Retrospective study. Participants: One hundred twenty-one eyes of 121 patients with confirmed FBN1 mutations between January 2015 and May 2023 were included. Methods: Comprehensive ophthalmic examination findings were reviewed, and the incidence of RD, atrophic, tractional, and neovascular maculopathy (ATN classification system), and PS was analyzed between different genotype groups. Only the more severely affected eye from each patient was included. Main Outcome Measures: Clinical features and risk factors. Results: Of 121 patients, 60 eyes (49.59%) exhibited posterior segment abnormalities, including RD (4, 3.31%), maculopathy (47, 38.84%), and PS (54, 44.63%). The mean age was 11.53 ± 11.66 years, with 79.34% of patients <20 years old. The location and region of mutations were found to be associated with the incidence of maculopathy (P = 0.013, P = 0.033) and PS (P = 0.043, P = 0.036). Mutations in the middle region had a lower incidence of maculopathy and PS (P = 0.028 and P = 0.006, respectively) than those in C-terminal region. Mutations in the transforming growth factor-ß (TGF-ß) regulating sequence exhibited a higher incidence of maculopathy and PS (P = 0.020, P = 0.040). Importantly, the location and region of mutations were also associated with the incidence of atrophic maculopathy (P = 0.013 and P = 0.033, respectively). Mutations in the middle region had a significantly lower probability of atrophic maculopathy (P = 0.006), while mutations in the TGF-ß regulating region had a higher incidence of atrophic maculopathy (P = 0.020). Conclusions: Maculopathy and PS were associated with the location and region of FBN1 mutations. Patients with mutations in the TGF-ß regulating region faced an increased risk of developing retinopathy. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

2.
Invest Ophthalmol Vis Sci ; 64(10): 28, 2023 07 03.
Artículo en Inglés | MEDLINE | ID: mdl-37477931

RESUMEN

Purpose: The purpose of this study was to investigate the relationship between axial length (AL) growth and FBN1 genotype in patients with Marfan syndrome (MFS) after lens surgery and customize the selection of intraocular lens (IOL) power. Methods: Patients with MFS who had lens surgery and primary IOL implantation received panel-based next-generation sequencing (NGS). The rate of axial length growth (RALG) was calculated using pre- and postoperative AL measurements and corrected log10-transformed age. A multivariable regression model of RALG was developed after analyzing the effect of FBN1 genotypes and confounding factors. Results: A total of 139 probands of MFS with a median age at lens surgery of 6.25 years (interquartile range [IQR] = 4.67, 12.50 years) were followed up for a median duration of 2.08 years (IQR = 1.16, 3.00 years). The AL growth curve between the age of 3 and 15 years old was logarithmic. Dominant-negative (DN) variants affecting the disulfide-bridge forming cysteines and the conserved residues for calcium-binding had significantly higher RALG than DN variants affecting other structures (P = 0.001) but comparable to that of haplo-insufficiency variants (P = 1.000). Pre-operative AL (b = 0.563, P = 0.011) and genotype constant (b = 2.603, P = 0.011) were significantly associated with RALG in the final model. A Python-based calculator, Marfan IOL Calculator version 2.0, was programmed using the RALG to predict postoperative AL and customize IOL selection based on the ocular biometric parameters and FBN1 genotype. Conclusions: FBN1 genotype impacted the growth of AL in patients with MFS after IOL implantation. Knowing the FBN1 genotype could help cataract surgeons to customize IOL selection.


Asunto(s)
Catarata , Lentes Intraoculares , Síndrome de Marfan , Humanos , Preescolar , Niño , Adolescente , Implantación de Lentes Intraoculares , Síndrome de Marfan/complicaciones , Síndrome de Marfan/genética , Ojo , Catarata/complicaciones , Genotipo
3.
J Cataract Refract Surg ; 49(6): 571-577, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-36745849

RESUMEN

PURPOSE: To predict the growth of axial length (AL) in patients with Marfan syndrome (MFS) and ectopia lentis (EL). SETTING: Eye and ENT Hospital of Fudan University, Shanghai, China. DESIGN: Consecutive retrospective case series. METHODS: Eyes were evaluated that had modified capsular tension ring and intraocular lens (IOL) implantation. The rate of AL growth (RALG) was calculated using AL divided by log10-transformed age. A multivariate linear regression model of RALG was developed after validation. RESULTS: 128 patients with MFS and EL were enrolled with a median follow-up duration of about 3 years. RALG was independent of age between 3 years and 15 years old ( P = .799) and decreased to 0 thereafter ( P = .878). Preoperative AL was associated with RALG in patients under 15 years old ( P = .003). Beta values for the final model of RALG were as below: intercept (-9.794) and preoperative AL (0.664). The postoperative AL was predicted as: postAL = preAL + RALG × log 10 ([postAge + 0.6]/[preAge + 0.6]). The mean prediction error was -0.003 (95% CI, -0.386 to 0.3791) mm and the mean absolute percentage error was 1.93% (95% CI, 0.73% to 3.14%). A Python-based calculator was developed to use the predicted AL in selecting IOL power and setting undercorrection. CONCLUSIONS: The AL growth of patients with MFS followed a logarithmic pattern and ceased at about age 15. A prediction model of postoperative AL was established for individual MFS patients between 3 and 15 years old, which could potentially optimize the IOL power selection.


Asunto(s)
Desplazamiento del Cristalino , Lentes Intraoculares , Síndrome de Marfan , Humanos , Preescolar , Adolescente , Niño , Desplazamiento del Cristalino/diagnóstico , Desplazamiento del Cristalino/cirugía , Desplazamiento del Cristalino/complicaciones , Síndrome de Marfan/complicaciones , Síndrome de Marfan/cirugía , Implantación de Lentes Intraoculares , Agudeza Visual , Estudios Retrospectivos , China
4.
Eur J Ophthalmol ; 33(4): 1624-1631, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36691699

RESUMEN

OBJECTIVE: To describe a new strategy to manage ectopia lentis in ASD patients assessing the visual outcomes and safety of supracapsular scleral sutured intraocular lens implantation and analyzing the accuracy of different intraocular lens (IOL) power calculation formulae. METHODS: Eight patients with ASD (13 eyes) were underwent supracapsular scleral suture fixation of posterior chamber (PC) IOL without capsular extirpation. The preoperative and postoperative clinical features were compared. The prediction error values from four formulae (SRK/T, Holladay 1, Hoffer Q, Haigis), with or without Wang-Koch (WK) adjustment, were calculated for the cases. RESULTS: Zonulodialysis and premature cataracts could be the main reason for the decreased vision in patients with ASD. There was a significant improvement in best corrected visual acuity on 3-month follow-up after applying supracapsular scleral suture fixation of PC IOL. The prediction errors of the different formulae showed a slight tendency towards postoperative myopia. The Haigis formula with WK adjustment showed the best performance. CONCLUSIONS: Supracapsular scleral suture fixation of IOLs for retaining the capsule-zonule barrier is a good option for ASD patients. The Haigis formula is recommended for ASD patients treated with supracapsular scleral suture fixation of IOLs. The predicted IOL power should be reduced based on the effect of the new anatomic position of the IOL to achieve a satisfactory visual outcome.


Asunto(s)
Desplazamiento del Cristalino , Lentes Intraoculares , Humanos , Implantación de Lentes Intraoculares , Agudeza Visual , Desplazamiento del Cristalino/cirugía , Esclerótica/cirugía , Estudios Retrospectivos , Refracción Ocular
5.
Hum Mutat ; 43(12): 2141-2152, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36208099

RESUMEN

ADAMTSL4 variants are one of the common causes of congenital ectopia lentis (EL), reported ocular comorbidities of which include iris anomalies, cataract, and glaucoma. However, a genotype-phenotype correlation has not been established. Potentially pathogenic ADAMTSL4 variants were screened from a Chinese cohort of congenital EL using panel-based next-generation sequencing followed by multiple bioinformatics analyses. The genotype-phenotype correlation was assessed via a systematic review of ADAMTSL4 variants within our data and those from the literature. A total of 12 variants of ADAMTSL4, including seven frameshift variants, one nonsense variant, two splicing variants, and two missense variants, were found in nine probands. Combing genetic and clinical information from 72 probands in the literature revealed 37 ADAMTSL4 variants known to cause EL, and the ethnic difference was prominent. The lens was inclined to dislocate inferior temporally (22, 27.16%), while the pupil was always located oppositely (9, 81.82%). Several anterior segments anomalies were identified, including ectopia pupillae (15, 18.52%), persistent pupillary membrane (9, 11.10%), poor pupil dilation (4, 30.8%), cataract (13, 24.10%), and glaucoma (8, 13.33%). Genotype-phenotype analysis revealed that truncation variants had higher risks of combined iris anomalies, including either ectopia pupillae or a persistent pupillary membrane (p = 0.007). The data from this study not only extend our knowledge of the ADAMTSL4 variant spectrum but also suggest that deleterious variants of ADAMTSL4 might be associated with severe ocular phenotypes.


Asunto(s)
Catarata , Desplazamiento del Cristalino , Glaucoma , Humanos , Pueblos del Este de Asia , Linaje , Proteínas ADAMTS/genética , Mutación , Desplazamiento del Cristalino/genética , Desplazamiento del Cristalino/patología , Catarata/genética
6.
Ophthalmic Res ; 2022 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-35785758

RESUMEN

INTRODUCTION: This is a cross-sectional cohort study focused on assessing the influence of ocular biometric parameters of different camera devices for accurately predicting the intraocular lens (IOL) power in the congenital ectopia lentis (EL) patients. METHODS: This study includes a total of 91 eyes of 60 patients with congenital EL from June 2018 to April 2021. All patients underwent lens subluxation surgery with Cionni modified capsular tension rings (MCTR) implantation. Ocular parameters measured by partial coherence interferometry (IOLMaster 700, Carl Zeiss Meditec AG, Jena, Germany) and rotating Scheimpflug camera (Pentacam HR system, Oculus Optikgeräte GmbH, Wetzlar, Germany) were acquired from the database. The authenticity of the different keratometries (K) were analyzed by comparing the prediction error in spherical equivalent under controlled formula SRK/T, Haigis, and after Wang-Koch (WK) adjustment. RESULTS: We observed significant greater K values were obtained in IOLMaster than Pentacam, resulting in more significant hyperopia error while calculating SRK/T. The IOL power calculated with the total corneal refractive power (TCRP) from Pentacam revealed the highest prediction accuracy, indicating that TCRP is the closest to the actual refractive power of the cornea. However, in an exceptional case for long eye patients, total keratometry from IOLMaster was better recommended when using formula Haigis with WK adjustment. CONCLUSIONS: For most instances, TCRP is the best-recommended source of K value while calculating IOL power for EL patients. However, the total keratometry from IOLMaster preferably fits for long eye patients, who require WK adjustment for Haigis formula.

7.
Front Med (Lausanne) ; 9: 732452, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35665341

RESUMEN

Objective: The aim of this study was to examine the biometric ocular manifestations and structural ocular features of anterior megalophthalmos (AM). Methods: Fifteen patients with AM (30 eyes) from the Eye & ENT Hospital of Fudan University were included. The age-matched control group consisted of 30 participants (30 eyes) who underwent Pentacam HR and IOLMaster 700 measurements for one normal eye. Data on demographics, biometric manifestations, and genotypes were carefully compared. Results: A total of 15 patients with AM and 30 control patients were enrolled. There were no differences in age (37.27 ± 19.1 vs. 31.43 ± 19.69 years, P = 0.249) between these two groups. AM eyes were characterized by premature cataracts (11/30, 36.67%) and zonular weakness with lens subluxation (22/30, 73.33%) compared with the control group. Notably, 20 of the 30 AM eyes (66.67%) had significant posterior iris bowing, and 16 of the 30 AM eyes (53.33%) showed an enlarged ciliary ring on ultrasound biomicroscopy (UBM). Mean corneal curvature was lower in the AM eyes (42.01 ± 2.06 D vs. 43.14 ± 1.38 D, P = 0.023). There was no significant difference in corneal pachymetry and central endothelial cell count between the AM and control groups. Significant differences were found in terms of the anterior chamber and white-to-white (WTW) among the Pentacam HR and IOLMaster 700 in patients with AM (P < 0.05). The difference was 0.53 ± 0.48 mm and 0.36 ± 0.14 mm, respectively (P < 0.001). Conclusion: The results of this cohort study conclude the biometric and structural ocular manifestations in Chinese cohorts. Posterior iris bowing (66.67%) and lens subluxation (73.33%) are the most characteristic findings in patients with AM with anatomical abnormalities of megalocornea and a deep anterior chamber, although corneal biometric manifestations of AM included flatter cornea and lower total corneal astigmatism. The knowledge of ocular manifestations of AM is important for diagnosis and preparation for the operation in advance to avoid intraoperative and postoperative complications. Significant differences were found in the anterior chamber and WTW values between the Pentacam HR and IOLMaster 700. Thus, we suggest that various examinations should be carefully considered before determining an AM diagnosis.

8.
Front Med (Lausanne) ; 9: 869539, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35492301

RESUMEN

Background: Microspherophakia (MSP) is a rare ocular condition, the lens surgery of which is complicated by both insufficient zonules and undersized capsule. Methods: This study included MSP eyes managed with phacoemulsification combined with supra-capsular and scleral-fixated intraocular lens implantation (SCSF-IOL) and made the comparison with those treated by transscleral-fixated modified capsular tension ring and in-the-bag intraocular lens implantation (MCTR-IOL). Results: A total of 20 MSP patients underwent SCSF-IOL, and 17 patients received MCTR-IOL. The postoperative best corrected visual acuity was significantly improved in both groups (P < 0.001), but no difference was found between the groups (P = 0.326). The IOL tilt was also comparable (P = 0.216). Prophylactic Nd:YAG laser posterior capsulotomy was performed 1 week to 1 month after the SCSF-IOL procedure. In the SCSF-IOL group, two eyes (10.00%) needed repeated laser treatment and one eye (5.00%) had a decentered capsule opening. Posterior capsule opacification was the most common complication (6, 35.29%) in the MCTR group. No IOL dislocation, secondary glaucoma, or retinal detachment was observed during follow-up. Conclusions: SCSF-IOL is a viable option for managing MSP and is comparable with the MCTR-IOL. Nd:YAG laser posterior capsulotomy was necessary to prevent residual capsule complications after the SCSF-IOL procedure.

9.
Am J Ophthalmol ; 237: 278-289, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34818515

RESUMEN

PURPOSE: To evaluate the diagnostic yield of congenital ectopia lentis (EL) in a Chinese cohort by combining panel-based next-generation sequencing with clinical findings. DESIGN: A cohort study. METHODS: In total, 175 patients with congenital EL and their available family members (n = 338) were enrolled. All patients with congenital EL underwent genetic testing. Genotype-phenotype analyses were conducted to assess the biometric and structural ocular manifestations of congenital EL. RESULTS: In total, 175 patients with congenital EL and 338 of their relatives were included in this study. In these patients, 92.57% (162 of 175) of disease-related variants were detected in FBN1 (83.43%), CPAMD8 (1.71%), COL4A5 (0.57%), ADAMTSL4 (3.43%), LTBP2 (1.71%), and CBS (2.29%). Based on genetic and clinical findings, the primary diagnostic rate was increased to 40.57% from 19.43% with the exception of the 91 diagnoses of potential Marfan syndrome, with a new diagnostic strategy for congenital EL, thus having been developed. Within this group of patients harboring FBN1 mutations, 16.44% (19 of 141) probands were diagnosed with EL syndrome and 2.13% (3 of 141) were diagnosed with Marfan syndrome. CONCLUSIONS: The results of this cohort study expand the genomic landscape associated with congenital EL in Chinese cohorts. FBN1 mutations represent the most common cause of congenital EL in this population, and we have developed a new diagnostic strategy for congenital EL subtypes via the use of a well-designed panel-based next-generation sequencing that can be used to efficiently and precisely diagnose patients with congenital EL in a cost-effective manner.


Asunto(s)
Desplazamiento del Cristalino , Síndrome de Marfan , China/epidemiología , Estudios de Cohortes , Desplazamiento del Cristalino/diagnóstico , Desplazamiento del Cristalino/genética , Fibrilina-1/genética , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Proteínas de Unión a TGF-beta Latente/genética , Síndrome de Marfan/complicaciones , Mutación , Linaje , Fenotipo
10.
Hum Mutat ; 42(12): 1637-1647, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34550612

RESUMEN

Mutations of fibrillin-1 (FBN1) have been associated with Marfan syndrome and pleiotropic connective tissue disorders, collectively termed as "type I fibrillinopathy". However, few genotype-phenotype correlations are known in the ocular system. Patients with congenital ectopia lentis (EL) received panel-based next-generation sequencing, complemented with multiplex ligation-dependent probe amplification. In a total of 125 probands, the ocular phenotypes were compared for different types of FBN1 mutations. Premature termination codons were associated with less severe EL and a thinner central corneal thickness (CCT) than the inframe mutations. The eyes of patients with mutations in the C-terminal region had a higher incidence of posterior staphyloma than those in the middle and N-terminal regions. Mutations in the TGF-ß-regulating sequence had larger horizontal corneal diameters (white-to-white [WTW]), higher incidence of posterior staphyloma, but less severe EL than those with mutations in other regions. Mutations in the neonatal region were associated with thinner CCT. Longer axial length (AL) was associated with mutations in the C-terminal region or TGF-ß regulating sequence after adjusting for age, EL severity, and corneal curvature radius. FBN1 genotype-phenotype correlations were established for some ocular features, including EL severity, AL, WTW, CCT, and so forth, providing novel perspectives and directions for further mechanistic studies.


Asunto(s)
Desplazamiento del Cristalino , Síndrome de Marfan , Desplazamiento del Cristalino/genética , Fibrilina-1/genética , Fibrilinas/genética , Genotipo , Humanos , Síndrome de Marfan/complicaciones , Síndrome de Marfan/diagnóstico , Síndrome de Marfan/genética , Proteínas de Microfilamentos/genética , Mutación , Fenotipo
11.
Int J Ophthalmol ; 14(8): 1218-1224, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34414087

RESUMEN

AIM: To investigate whether the axial length (AL)/total corneal refractive power (TCRP) ratio is a sensitive and simple factor that can be used for the early diagnosis of Marfan's syndrome (MFS) in children. METHODS: The relationship between the AL/TCRP ratio and the diagnosis of MFS for 192 eyes in 97 children were evaluate. The biological characteristics, including age, sex, AL, and TCRP, were collected from medical records. Receiver operating characteristic (ROC) curve analysis was performed to investigate whether the AL/TCRP ratio effectively distinguishes MFS from other subjects. The Youden index was used to re-divide the whole population into two groups according to an AL/TCRP ratio of 0.59. RESULTS: Of 96 subjects (mean age 7.46±3.28y) evaluated, 56 (110 eyes) had a definite diagnosis of MFS in childhood based on the revised Ghent criteria, 41 (82 eyes) with diagnosis of congenital ectopia lentis (EL) were included as a control group. AL was negatively correlated with TCRP, with a linear regression coefficient of -0.36 (R 2=0.08). A significant correlation was found between age and the AL/TCRP ratio (P=0.023). ROC curve analysis showed that the AL/TCRP ratio distinguished MFS from the other patients at a threshold of 0.59. MFS patients were present in 24/58 (41.38%) patients with an AL/TCRP ratio of ≤0.59 and in 34/39 (87.18%) patients with an AL/TCRP ratio of >0.59. CONCLUSION: An AL/TCRP ratio of >0.59 is significantly associated with the risk of MFS. The AL/TCRP ratio should be measured as a promising marker for the prognosis of children MFS. Changes in the AL/TCRP ratio should be monitored over time.

12.
Ophthalmic Res ; 64(5): 811-819, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34034266

RESUMEN

INTRODUCTION: Marfan syndrome (MFS) is characterized by ectopia lentis (EL) and elongated axial length (AL). The characteristics of AL in young patients with MFS and bilateral EL before the lens surgery are not fully understood. METHODS: This study reviewed MFS patients under 20 years old with bilateral EL from January 2015 to October 2020. The Z-scores were introduced in terms of the number of standard deviations from the mean of age-matched normative data. Using Z-scores, the distribution of AL and influence factors were evaluated. The correlations between AL and other biometrics were analyzed. RESULTS: We reviewed 183 patients and enrolled both eyes. The mean age was 8.44 ± 4.69 years. About 36% of the patients were children under 6 years old. The median AL increased from 23.16 mm under 5 years old to 26.20 mm in the 16-20 age group, and when plotted, the trend presented a logarithmic curvature (R2 = 0.145, p < 0.001). The median Z-AL score was 1.24. One-third of eyes had Z-score <0. About 20% of the patients had AL difference over 1 mm between the right and left eyes, and the right one had longer Z-AL scores (p = 0.013). The eye complicated with megalocornea (10, 7.04%) had larger Z-AL scores (4.72 ± 3.51 vs. 1.10 ± 2.25, p = 0.002). A positive correlation was found between Z-AL and Z-corneal curvature radius (r = 0.265, p < 0.001). CONCLUSION: Young patients with bilateral EL but small AL should not be excluded from MFS without systematic examination. The age-adjusted Z-score will facilitate further study of the individual variations in AL across different ages.


Asunto(s)
Desplazamiento del Cristalino , Cristalino , Síndrome de Marfan , Adolescente , Biometría , Niño , Preescolar , Humanos , Síndrome de Marfan/complicaciones , Agudeza Visual , Adulto Joven
14.
J Zhejiang Univ Sci B ; 8(8): 604-8, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17657865

RESUMEN

OBJECTIVES: to verify the feasibility and reliability of the electronic version of Chinese SF-36 based on the Quality-of-Life-Recorder. DESIGN: A crossover randomized controlled trial, comparing a paper-based and an electronic version of the Chinese SF-36, was conducted. According to generated random numbers, interviewees were asked to fill out either the electronic version or the paper version first. The second version was filled in after a pause of at least 10 min. SETTINGS AND PARTICIPANTS: One group of 100 medical students at the School of Medicine of Zhejiang University and the other group of 50 outpatients at a clinic for general practice in Hangzhou City (China) were eventually recruited in this study. RESULTS: The acceptance of the electronic version was good (60% of medical students and 84% of outpatients preferred the electronic version). At the level of eight-scale scores, the mean-difference for each scale (except for general health) between the two versions was less than 5%. At the level of 36 questions, the percentage of "exact agreement" ranged within 64%-99%; the percentage of "global agreement" ranged within 72%-99%; 77% of the kappa coefficients demonstrated "good/excellent agreement" and 23% of the kappa coefficients demonstrated "medium agreement". CONCLUSION: This study, for the first time, can provide empirical basis for the confirmation of the feasibility and reliability of the electronic version of the Chinese SF-36 and may provide an impulse towards widespread deployment of the Quality-of-Life-Recorder in Chinese populations.


Asunto(s)
Electrónica/instrumentación , Encuestas Epidemiológicas , Calidad de Vida , Encuestas y Cuestionarios , Adulto , China , Estudios Cruzados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo
15.
J Zhejiang Univ Sci B ; 6(9): 936-40, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16130199

RESUMEN

In more recent times, health-related quality of life (HRQOL) measurements have formed an important part of assessing the quality of routine care in general practice. For a measure to have clinical usefulness it must not only be valid, appropriate, reliable, responsive, and capable of being interpreted, but it must also be simple, fast to complete, easy to score, and provide useful clinical data. The Two-step method of choosing appropriate measures is introduced. Then through comparison of generic instruments with disease-specific instruments, we can conclude that sometimes a combination of generic and disease-specific HRQOL measures may be more appropriate for monitoring changes in a patient's health status due to an intervention.


Asunto(s)
Medicina Familiar y Comunitaria , Calidad de Vida , Humanos , Evaluación de Resultado en la Atención de Salud , Garantía de la Calidad de Atención de Salud
16.
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA