Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(1): 60-68, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37888200

RESUMEN

INTRODUCTION: Carina breakthrough (CB) at the right pulmonary vein (RPV) can occur after circumferential pulmonary vein isolation (PVI) due to epicardial bridging or transient tissue edema. High-power short-duration (HPSD) ablation may increase the incidence of RPV CB. Currently, the surrogate of ablation parameters to predict RPV CB is not well established. This study investigated predictors of RPV CB in patients undergoing ablation index (AI)-guided PVI with HPSD. METHODS: The study included 62 patients with symptomatic atrial fibrillation (AF) who underwent AI-guided PVI using HPSD. Patients were categorized into two groups based on the presence or absence of RPV CB. Lesions adjacent to the RPV carina were assessed, and CB was confirmed through residual voltage, low voltage along the ablation lesions, and activation wavefront propagation. RESULTS: Out of the 62 patients, 21 (33.87%) experienced RPV CB (Group 1), while 41 (66.13%) achieved first-pass RPV isolation (Group 2). Despite similar AI and HPSD, patients with RPV CB had lower contact force (CF) at lesions adjacent to the RPV carina. Receiver operating characteristic (ROC) curve analysis identified CF < 10.5 g as a predictor of RPV CB, with 75.7% sensitivity and 56.2% specificity (area under the curve: 0.714). CONCLUSION: In patients undergoing AI-guided PVI with HPSD, lower CF adjacent to the carina was associated with a higher risk of RPV CB. These findings suggest that maintaining higher CF during ablation in this region may reduce the occurrence of RPV CB.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Recurrencia
2.
J Cardiol ; 83(5): 306-312, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37838339

RESUMEN

BACKGROUND: Modifying the autonomic system after catheter ablation may prevent the recurrence of atrial fibrillation (AF). Evaluation of skin sympathetic nerve activity (SKNA) is a noninvasive method for the assessment of sympathetic activity. However, there are few studies on the effects of different energy settings on SKNA. OBJECTIVE: To investigate the changes in SKNA in different energy settings and their relationship to AF ablation outcomes. METHODS: Seventy-two patients with paroxysmal and persistent AF were enrolled. Forty-three patients received AF ablation with the conventional (ConV) energy setting (low power for long duration), and 29 patients using a high-power, short-duration (HPSD) strategy. The SKNA was acquired from the right arm 1 day before and after the radiofrequency ablation. We analyzed the SKNA and ablation outcomes in the different energy settings. RESULTS: Both groups had a similar baseline average SKNA (aSKNA). We found that the median aSKNA increased significantly from 446.82 µV to 805.93 µV (p = 0.003) in the ConV group but not in the HPSD group. In the ConV group, patients without AF recurrence had higher aSKNA values. However, the 1-year AF recurrence rate remained similar between both groups (35 % vs. 28 %, p = 0.52). CONCLUSION: The post-ablation aSKNA levels increased significantly in the ConV group but did not change significantly in the HPSD group, which may reflect different neuromodulatory effects. However, the one-year AF recurrence rates were similar for both groups. These results demonstrate that the HPSD strategy has durable lesion creation but less lesion depth, which may reduce collateral damage.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Sistema Nervioso Simpático , Ablación por Catéter/métodos , Resultado del Tratamiento , Venas Pulmonares/cirugía , Recurrencia
3.
J Cardiovasc Electrophysiol ; 34(12): 2504-2513, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37822117

RESUMEN

INTRODUCTION: Despite undergoing an index ablation, some patients progress from paroxysmal atrial fibrillation (PAF) to persistent AF (PersAF), and the mechanism behind this is unclear. The aim of this study was to investigate the predictors of progression to PersAF after catheter ablation in patients with PAF. METHODS: This study included 400 PAF patients who underwent an index ablation between 2015 and 2019. The patients were classified into three groups based on their outcomes: Group 1 (PAF to sinus rhythm, n = 226), Group 2 (PAF to PAF, n = 146), and Group 3 (PAF to PersAF, n = 28). Baseline and procedural characteristics were collected, and predictors for AF recurrence and progression were evaluated. RESULTS: The mean age of the patients was 58.4 ± 11.1 years, with 272 males. After 3 years of follow-up, 7% of the PAF cases recurred and progressed to PersAF despite undergoing an index catheter ablation. In the multivariable analysis, a larger left atrial (LA) diameter and the presence of non-pulmonary vein (PV) triggers during the index procedure independently predicted recurrence. Moreover, a larger LA diameter, the presence of non-PV triggers, and a history of thyroid disease independently predicted AF progression. CONCLUSION: The progression from PAF to PersAF after catheter ablation is associated with a larger LA diameter, history of thyroid disease, and the presence of non-PV triggers. Meticulous preprocedural evaluation, patient selection, and comprehensive provocation tests during catheter ablation are recommended.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Enfermedades de la Tiroides , Masculino , Humanos , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
4.
Circ Arrhythm Electrophysiol ; 16(2): e011149, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36688314

RESUMEN

BACKGROUND: The presence of abnormal substrate of left atrium is a predictor of atrial fibrillation (AF) recurrence after pulmonary vein isolation. We aimed to investigate the isochronal late activation mapping to access the abnormal conduction velocity for predicting AF ablation outcome. METHODS: Forty-five paroxysmal AF patients (30 males, 57.8±8.7 years old) who underwent pulmonary vein isolation were enrolled. Isochronal late activation mapping was retrospectively constructed with 2 different windows of interest: from onset of P wave to onset of QRS wave on surface electrocardiography (W1) and 74 ms tracking back from the end of P wave (W2). Deceleration zone was defined as regions with 3 isochrones (DZa) or ≥4 isochrones (DZb) within a 1 cm radius on the isochronal late activation mapping, and the estimated conduction velocity (ECV) are 0.27 m/s and <0.20 m/s for DZa and DZb, respectively in W2. The distribution of deceleration zone was compared with the location of low-voltage zone (bipolar voltage ≤0.5 mV). Any recurrence of atrial arrhythmias was defined as the primary end point during follow ups after a 3-month blanking period. RESULTS: Pulmonary vein isolation was performed in all patients, and there were 2 patients (4.4%) received additional extrapulmonary vein ablation. After a mean follow-up of 12.7±4.5 months, recurrence of AF occurred in 14 patients (31.1%). Patients with the presence of DZb in W2 had higher AF recurrence (Kaplan-Meier event rate estimates: HR, 9.41 [95% CI, 2.61-33.90]; log-rank P<0.0001). There were 52.6% of the DZb locations in W2 comparable to the distributions of low-voltage zone and 47.4% DZb were distributed in the area without low-voltage zone. CONCLUSIONS: Deceleration zone detected by isochronal late activation mapping represents a critical AF substrate, it accurately predicts the AF recurrence following ablation in patients with paroxysmal AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Venas Pulmonares/cirugía , Atrios Cardíacos , Electrocardiografía , Ablación por Catéter/efectos adversos , Recurrencia , Resultado del Tratamiento
6.
J Cardiol ; 81(5): 434-440, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36372323

RESUMEN

BACKGROUND: The neuromodulation effect after ventricular arrhythmia (VA) ablation is unclear. The study aimed to investigate skin sympathetic nerve activity (SKNA) changes in patients receiving catheter ablations for idiopathic VA. METHODS: Of 43 patients with drug-refractory symptomatic VA receiving ablation, SKNA was continuously recorded for 10 min during resting from electrocardiogram lead I configuration and bipolar electrodes on the right arm 1 day before and 1 day after ablation. RESULTS: Twenty-two patients with acute procedure success and no recurrence during follow-ups were classified as sustained success group (group 1). Other 21 patients were classified as failed ablation group (group 2). Baseline SKNA showed no significant difference between the two groups. Post-ablation SKNA in group 2 was significantly higher than in group 1. In patients with ablation involved right ventricular outflow tract (RVOT), the post-ablation SKNA was also significantly higher in group 2. In contrast, there was no difference in post-ablation SKNA between groups in patients receiving non-RVOT ablation. CONCLUSION: The neuromodulation response after RVOT ablation may correspond to the sympathetic nerve distribution at RVOT. Augmentation of sympathetic activity after VA ablation indicates an unsuccessful VA suppression, especially in patients receiving ablation of RVOT VA.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Arritmias Cardíacas , Ventrículos Cardíacos , Ablación por Catéter/métodos , Sistema Nervioso Simpático/cirugía , Piel , Electrocardiografía , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
7.
Front Cardiovasc Med ; 9: 1030916, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36465473

RESUMEN

Introduction: Unsuccessful endocardial ablation for perimitral atrial flutter (AFL) could be attributed by the epicardial bridging. Objective: This study aimed to investigate the electrophysiological characteristics of epicardial breakthrough during catheter ablation of perimitral AFL. Materials and methods: This retrospective study recruited 40 patients who received successful catheter ablation of perimitral AFL from January 2016 to June 2021. The patients were divided into two groups: group 1 (n = 18) successful endocardial ablation, and group 2 (n = 22) successful epicardial ablation following unsuccessful endocardial ablation owing to incomplete mitral block or unachievable termination AFL. The local electrogram (EGM) interval of coronary sinus (CS) duration perimitral AFL was measured before catheter ablation. Results: There was no significant difference in the baseline characteristics between the two groups. In group 2, 60% of successful epicardial ablation was performed in intra-CS ablation and 40% in VOM ethanol infusion. Group 2 patients had a longer EGM interval of distal CS than that in group 1 (CS1-2: 64.2 17.5 vs. 42.4 0.09 ms, P = 0.008, CS3-4: 57.13 19.4 vs. 43.8 7.5 ms; P = 0.001). The conduction velocity at successful site was slower in group 2 compared to group 1 (0.18 0.05 vs. 0.75 0.19 m/s, P = 0.040). In the multivariate analysis, distal EGM interval (CS1-2) was identified as independent predictor of the need of epicardial ablation with the optimal cutoff of 49 ms. Conclusion: Longer EGM interval in distal CS during perimitral AFL was observed in perimitral AFL patients with epicardial breakthrough following endocardial-failed ablation, which may be associated with the need of epicardial ablation.

8.
J Pers Med ; 12(8)2022 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-36013235

RESUMEN

Autonomic system plays a pivotal role in the pathogenesis of paroxysmal atrial fibrillation (AF). Skin sympathetic nerve activity (SKNA) is a noninvasive tool for assessing sympathetic tone. However, data on changes in SKNA after ablation are limited. Here, we retrospectively enrolled 37 patients with symptomatic drug-refractory paroxysmal AF who underwent pulmonary vein isolation (PVI) with radiofrequency ablation (RFA) or cryoablation (CBA). SKNA was measured from the chest and right arm 1 day prior to ablation, as well as 1 day and 3 months after ablation. One day after ablation, the SKNA-Arm increased from 517.1 µV (first and third quartiles, 396.0 and 728.0, respectively) to 1226.2 µV (first and third quartiles, 555.2 and 2281.0), with an increase of 179.8% (125% and 376.0%) (p < 0.001); the SKNA-Chest increased from 538.2 µV (first and third quartiles, 432.9 and 663.9) to 640.0 µV (first and third quartiles, 474.2 and 925.6), with an increase of 108.3% (95.6% and 167.9%) (p = 0.004), respectively. In those without recurrence, there was a significant increase in SKNA 1 day after ablation as compared with those before ablation. Twelve patients received SKNA measurement 3 months after ablation; both SKNA-Arm (p = 0.31) and SKNA-Chest (p = 0.27) were similar to those before ablation, respectively. Among patients with symptomatic drug-refractory paroxysmal AF receiving PVI, increased SKNA was observed 1 day after ablation and returned to the baseline 3 months after ablation. Elevation of SKNA was associated with lower early and late recurrences following ablation.

10.
J Clin Med ; 11(6)2022 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-35329807

RESUMEN

INTRODUCTION: Data regarding the efficacy of catheter ablation in patients with atrial fibrillation (AF) and patients' previous history of pulmonary lobectomy/pneumonectomy are scanty. We sought to evaluate the efficacy and long-term follow-up of catheter ablation in this highly selected group of patients. MATERIAL AND METHODS: Twenty consecutive patients (8 females, 40%; median age 65.2 years old) with a history of pneumonectomy/lobectomy and paroxysmal or persistent AF, treated by means of pulmonary vein isolation (PVI) at ten participating centers were included. Procedural success, intra-procedural complications, and AF recurrences were considered. RESULTS: Fifteen patients had a previous lobectomy and five patients had a complete pneumonectomy. A large proportion (65%) of PV stumps were electrically active and represented a source of firing in 20% of cases. PVI was performed by radiofrequency ablation in 13 patients (65%) and by cryoablation in the remaining 7 cases. Over a median follow up of 29.7 months, a total of 7 (33%) AF recurrences were recorded with neither a difference between patients treated with cryoablation or radiofrequency ablation or between the two genders. CONCLUSIONS: Catheter ablation by radiofrequency ablation or cryoablation in patients with pulmonary stumps is feasible and safe. Long-term outcomes are favorable, and a similar efficacy of catheter ablation has been noticed in both males and females.

11.
J Cardiol ; 80(1): 34-40, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35337707

RESUMEN

BACKGROUND: The identification of post pulmonary vein isolation (PVI) gaps by activation and voltage maps is time-consuming. This study aimed to investigate the characteristics, efficiency and accuracy of LiveView dynamic display module (EnSite™ Dynamic Display; Abbott, Abbott Park, IL, USA) in unmasking post PVI gaps and conduction block line. METHOD: Twenty four patients with paroxysmal atrial fibrillation (PAF) who failed to achieve first-pass PVI or with recurrent PAF were enrolled. Ninety-six pulmonary veins (PVs) were evaluated, and gaps were identified in 25 (26.0%) PVs. The gap location was confirmed by activation and propagation maps; 110 frames on gaps and 118 frames on block lines were analyzed by using LiveView module. We defined isochronal crowding in the local activation time (LAT) mode as three colors between two adjacent electrodes. Each frame was classified as with or without isochronal crowding in LAT mode and one/continuous color or isochronal discontinuity in reentrant mode. The gray color inside the PVs was considered to represent conduction block. RESULT: The isochronal crowding could be found on both gap and block line in LAT mode, whereas isochronal discontinuity only presented on the block line in reentrant mode. The sensitivity and specificity of isochronal discontinuity or gray color in reentrant mode to identify block line were 61.0% and 100%, respectively. The sensitivity and specificity of isochronal crowding or gray color in LAT mode to identify block line were 71.2% and 71.8%, respectively. CONCLUSION: Reentrant mode in LiveView module is very specific in identifying block lines. We proposed an efficient, practical algorithm to differentiate the block line from PV gaps.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Humanos , Venas Pulmonares/cirugía , Tecnología , Resultado del Tratamiento
12.
Int J Cardiol ; 351: 42-47, 2022 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-34954276

RESUMEN

INTRODUCTION: The presence of bipolar low-voltage zone (LVZ) is a predictor of AF recurrence after PV isolation (PVI). However, changes of wavefront and bipole directions may cause different electrogram characteristics. We aimed to investigate whether using omnipolar maximum voltage (Vmax) map derived from high density (HD) Grid mapping catheter could assess LVZ and AF ablation outcome accurately. METHODS: Fifty paroxysmal AF patients (27 males, 57.8 ± 9.5 years old) who underwent 3D mapping guided PVI were enrolled. Left atrial voltage mapping during sinus rhythm before ablation was performed. The significant LVZ (<0.5 mV with area > 5 cm2) were defined as sites by omnipolar Vmax, bipolar HD wave map, conventional bipolar electrograms acquired from electrode pairs along to and across to the catheter shaft. The primary end point was the first documented recurrence of any AF during follow-ups. RESULTS: PVI was performed in all patients, and there were 2 patients (4%) who also received additional non-PV triggers ablation. After a follow-up of 11.4 ± 5.4 months, recurrence of AF occurred in 12 patients (24%). The presence of a significant LVZ was less detected by omnipolar Vmax map, compared to HD wave map (24.0% vs. 58.0%, p = 0.001). LVZ detected by omnipolar Vmax map independently predicted the AF recurrence (odds ratio 16.91; 95% CI, 3.17-90.10; p = 0.001). CONCLUSION: LVZ detected by omnipolar Vmax map accurately predicts the AF recurrence following ablation in paroxysmal AF, compared to conventional bipolar and HD wave maps, suggesting the omnipolar Vmax map can precisely define the atrial substrate property.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...