Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sci Prog ; 107(1): 368504241228106, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38312046

RESUMEN

Aiming at the problems of poor adjustment effect, weak anti-disturbance ability, and low robustness of the traditional sliding mode algorithm for permanent magnet synchronous motor speed sensorless, a permanent magnet synchronous motor speed observation method combining super-twisting sliding mode control algorithm and fuzzy control is proposed to accelerate the convergence speed of the system and improve the anti-disturbance ability. Fuzzy rules are used to solve the problem of obtaining the upper bound of the boundary function in the super-twisting algorithm. Moreover, the fuzzy algorithm is used to output the variable sliding mode gain instead of the fixed sliding mode coefficient to improve the system robustness and suppress the jitter. The simulation results show that the overshoot of the control system is 4%, the lag time is not more than 0.003 ms, the speed error is not more than 1%, and the response and adjustment time is not more than 0.02 s. The proposed control strategy improves the tracking accuracy and response speed of the system, suppresses the sliding mode chattering, and enhances the anti-interference ability of the system.

2.
Radiat Oncol ; 18(1): 141, 2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37626342

RESUMEN

BACKGROUND: Hypothyroidism (HT) and subclinical HT after radiotherapy is frequent in nasopharyngeal carcinoma (NPC) patients, results in negative impact on patients' quality of life. The percentage of thyroid volume receiving more than 40 Gy (V40) ≤ 85% was reported to be a useful dose constraint to adopt during intensity-modulated radiation therapy (IMRT) planning. This study aims to verify whether V40 ≤ 85% can be used as an effective dose constraint in IMRT planning in a randomized clinical trial. METHODS: This single-center 1:1 randomized clinical trial was conducted in Fujian province hospital between March 2018 and September 2022. All patients were treated with IMRT and randomized to induction chemo followed by concurrent chemo-IMRT or concurrent chemo-IMRT alone. Ninety-two clinically NPC patients were included in this study. The thyroid function tests were performed for all patients before and after radiation at regular intervals. Thyroid dose-constraint was defined as V40 ≤ 85%. The primary outcome in this study was subclinical HT. RESULTS: Median follow up was 34 months. Significant difference in the incidence of subclinical HT between the thyroid dose-constraint group and unrestricted group was observed (P = 0.023). The risk of subclinical HT in the thyroid dose-constraint group was lower than that in the unrestricted group (P = 0.022). Univariate and multivariate cox regression analysis indicated that thyroid dose-constraint was a protective effect of subclinical HT (HR = 0.408, 95% CI 0.184-0.904; HRadjusted = 0.361, 95% CI 0.155-0.841). CONCLUSION: V40 ≤ 85% can be used as an effective dose constraint in IMRT planning to prevent radiation-induced subclinical HT.


Asunto(s)
Hipotiroidismo , Neoplasias Nasofaríngeas , Radioterapia de Intensidad Modulada , Humanos , Carcinoma Nasofaríngeo/radioterapia , Calidad de Vida , Radioterapia de Intensidad Modulada/efectos adversos , Hipotiroidismo/etiología , Neoplasias Nasofaríngeas/radioterapia
3.
Biomed Opt Express ; 11(12): 7109-7119, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33408983

RESUMEN

The concept of being able to urinate in a cup and screen for colorectal cancer (CRC) is fascinating to the public at large. Here, a simple and label-free urine test based on surface-enhanced Raman spectroscopy (SERS) was employed for CRC detection. Significant spectral differences among normal, stages I-II, and stages III-IV CRC urines were observed. Using discriminant function analysis, the diagnostic sensitivities of 95.8%, 80.9%, and 84.3% for classification of normal, stages I-II, and stages III-IV CRC were achieved in training model, indicating the great promise of urine SERS as a rapid, convenient and noninvasive method for CRC staging detection.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...