Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Anal Chim Acta ; 1197: 339495, 2022 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-35168719

RESUMEN

Metal modified paper-based substrates were utilized for microfluidic paper-based solution sampling coupled with Pb2+-ion selective electrodes (ISEs) with the aim of controlling the super-Nernstian response which usually occurs when using unmodified paper substrates. Potentiometric responses of Pb2+-ISEs coupled with gold, platinum and palladium coated paper substrates were investigated. Potentiometric response time was found to be predominantly dependent on the thickness of metallic layer deposited at the paper substrates. Paper-based substrates coated on both sides with 38 nm gold layers were found to be the most advantageous in controlling the super-Nernstian response of ISEs at non-equilibrium conditions. Durability studies indicated that the lifetime of Pb2+-ISEs could be doubled when used with paper-based substrates in complex environmental samples with high solid-to-liquid content. Determination of lead in real samples using metal modified paper substrates coupled with Pb2+-ISEs was validated by inductively coupled plasma optical emission spectrometry (ICP-OES). Detailed life cycle assessments were performed for model screen printed potentiometric sensors with and without metal modified paper-based solution sampling substrates. The results confirmed that the use of modified paper substrates demonstrated lower environmental impact per potentiometric measurement of Pb2+-ISE in prepared simulated environmental sample as compared to sensors without the use of paper substrates.


Asunto(s)
Metales Pesados , Microfluídica , Electrodos de Iones Selectos , Potenciometría
2.
ACS Sens ; 6(10): 3667-3676, 2021 10 22.
Artículo en Inglés | MEDLINE | ID: mdl-34585917

RESUMEN

Transmembrane ion fluxes have earlier been identified as a source of potential instability in solid contact ion-selective electrodes (SC-ISEs). In this work, foamlike structures were intentionally introduced into a potassium-sensitive plasticized poly(vinyl chloride) ion-selective membrane (ISM) near the membrane|solid contact interface by controlling the temperature during membrane deposition. Foamlike structures in the ISM were shown to be effective at physically tailoring the transport of ions in the ion-selective membrane, greatly reducing the flux of interfering ions from the sample to the membrane|solid contact interface. The drifts during a conventional water layer test were hence able to be greatly mitigated, even with SC-ISEs incorporating a relatively hydrophilic poly(3,4-ethylenedioxythiophene) doped with poly(styrenesulfonate) (PEDOT:PSS) solid contact. In solutions with a high background concentration of interfering ions, equilibrated ion-selective electrodes with foamlike membranes were able to reproduce their initial potentials within 0.6 mV uncertainty (n = 3) from 0 to 18 h. This was achieved despite sensor exposure to solutions exceeding the selectivity limit of the ISEs in 3 h intervals, allowing improvement of the potential reproducibility of the sensors. Since the introduction of foamlike structures into ISM is linked to temperature-controlled membrane deposition, it is envisaged that the method is generally applicable to all solid contact ion-selective electrodes that are based on polymeric membranes and require membrane deposition from the cocktail solution.


Asunto(s)
Electrodos de Iones Selectos , Polímeros , Interacciones Hidrofóbicas e Hidrofílicas , Iones , Reproducibilidad de los Resultados
3.
Anal Chim Acta ; 1162: 338304, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33926699

RESUMEN

The solid contact ion-selective electrodes (SC-ISEs) have been extensively studied in the field of ion sensing as they offer the possibility of miniaturization, are relatively inexpensive in comparison to other analytical techniques and allow straightforward and routine analyses of ions in a number of clinical, environmental and industrial process samples. In recent years, significant interest has grown in the development of SC-ISEs with well-defined interfacialpotentials at the membrane, solid contact, and substrate electrode interfaces. This has resulted in interesting SC-ISEs exhibiting high electrode-to-electrode potential reproducibility, for those made in a single batch of electrodes, some approaching or exceeding those observed in liquid-contact ISEs. The advancement in the potential reproducibility of SC-ISEs has been partially achieved by scrutinizing insufficiently reproducible fabrication methods of SC-ISEs, or by introducing novel control measures or modifiers to components of the ISEs. This paper provides an overview of the methods as well as the challenges in establishing and maintaining reproducible potentials during the fabrication and use of novel SC-ISEs. The rules outlined in the works reviewed may form the basis of further development of cost-effective, user-friendly, limited calibration or calibration-free potentiometric SC-ISEs to achieve reliable ion analyses here and now.

4.
Anal Chem ; 93(4): 1880-1888, 2021 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-33430590

RESUMEN

This Feature summarizes recent works in paper-based potentiometry and voltammetry in heavy metal determination. Interactions of paper substrates with heavy metals, influence on the sensing response, and modification methods applied to paper substrates to improve the performance of recently developed electrochemical sensors are discussed. Since the rekindling of interest in paper-based analytical devices, methodologies and electrode designs for heavy metal determinations are highlighted. Promising aspects of the use of these sensors for samples containing solids and the increased versatility of the use of paper in analytics offers the possibility of increased acceptance of these low-cost platforms.


Asunto(s)
Técnicas Electroquímicas/métodos , Metales Pesados/química , Papel , Técnicas Electroquímicas/economía , Técnicas Electroquímicas/instrumentación , Monitoreo del Ambiente/instrumentación , Monitoreo del Ambiente/métodos
5.
Anal Chim Acta ; 1142: 84-98, 2021 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-33280707

RESUMEN

Analytical diagnostics of skin features was developed through application of portable and fast skin mapping based on electro-controlled deposition of conducting polymers onto metal-sebum modified surfaces. In this analytical diagnostic technique, the development of skin pattern is based on electropolymerization of conducting polymers within insulating barriers in skin stamp provided by natural sebum to monitor the 3D nature of various skin features. The recorded skin maps reach a µm-level resolution and are proved to be capable of recognition, enhancement, and reproduction of surface outlines of various skin topographies, subsequently assisting dermatological diagnosis. The technique can precisely record skin surface morphology and reflect the vertical dimension information within 10 min and is aimed to assist dermatologists working with patients suffering from skin diseases via recording or monitoring the skin surface conditions. Additionally, successful trials of loading and electro-controlled release of Cu2+ into/from the developed skin patterns reveals its potential to be also utilized for treatment of pathological skin conditions. Based on the developed analytical diagnostic technique, a well-designed 3D printed portable prototype device based on electrosynthesis of the conducting polymer powered by an ordinary battery (1.5 V) was tested and was found to have excellent performance in onsite 3D skin pattern reproduction from live human skin.


Asunto(s)
Polímeros , Sebo , Humanos , Piel
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...