Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Radiology ; 300(1): 120-129, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33944629

RESUMEN

Background The interpretation of radiographs suffers from an ever-increasing workload in emergency and radiology departments, while missed fractures represent up to 80% of diagnostic errors in the emergency department. Purpose To assess the performance of an artificial intelligence (AI) system designed to aid radiologists and emergency physicians in the detection and localization of appendicular skeletal fractures. Materials and Methods The AI system was previously trained on 60 170 radiographs obtained in patients with trauma. The radiographs were randomly split into 70% training, 10% validation, and 20% test sets. Between 2016 and 2018, 600 adult patients in whom multiview radiographs had been obtained after a recent trauma, with or without one or more fractures of shoulder, arm, hand, pelvis, leg, and foot, were retrospectively included from 17 French medical centers. Radiographs with quality precluding human interpretation or containing only obvious fractures were excluded. Six radiologists and six emergency physicians were asked to detect and localize fractures with (n = 300) and fractures without (n = 300) the aid of software highlighting boxes around AI-detected fractures. Aided and unaided sensitivity, specificity, and reading times were compared by means of paired Student t tests after averaging of performances of each reader. Results A total of 600 patients (mean age ± standard deviation, 57 years ± 22; 358 women) were included. The AI aid improved the sensitivity of physicians by 8.7% (95% CI: 3.1, 14.2; P = .003 for superiority) and the specificity by 4.1% (95% CI: 0.5, 7.7; P < .001 for noninferiority) and reduced the average number of false-positive fractures per patient by 41.9% (95% CI: 12.8, 61.3; P = .02) in patients without fractures and the mean reading time by 15.0% (95% CI: -30.4, 3.8; P = .12). Finally, stand-alone performance of a newer release of the AI system was greater than that of all unaided readers, including skeletal expert radiologists, with an area under the receiver operating characteristic curve of 0.94 (95% CI: 0.92, 0.96). Conclusion The artificial intelligence aid provided a gain of sensitivity (8.7% increase) and specificity (4.1% increase) without loss of reading speed. © RSNA, 2021 Online supplemental material is available for this article.


Asunto(s)
Inteligencia Artificial , Fracturas Óseas/diagnóstico por imagen , Médicos/estadística & datos numéricos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiólogos/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios Transversales , Servicio de Urgencia en Hospital , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...