RESUMEN
AIM: To evaluate the efficacy and safety of the advanced technique for positioning the endocardial electrodes of a cardiac contractility modulation (CCM) device. MATERIALS AND METHODS: The CCM system was implanted in 100 patients, of which 60 CCM electrodes were positioned in the most optimal zones of myocardial perfusion, in particular, in the zone of the minor focal-scar/fibrotic lesion (the Summed Rest Score of 0 to 1-2, the intensity of the radiopharmaceutical at least 30%), and in 40 patients according to the standard procedure. Before the implantation of the CCM system, 60 patients underwent tomography (S-SPECT) of the myocardium with 99mTc-methoxy-isobutyl-isonitrile at rest to determine the most optimal electrode positioning zones and 100 patients underwent transthoracic echocardiography at baseline and after 12 months to assess the effectiveness of surgical treatment. RESULTS: Improved ventricular electrode positioning technique is associated with the best reverse remodeling of the left ventricular myocardium, especially in patients with ischemic chronic heart failure, with less radiation exposure to the surgeon and the patient, and without electrode-related complications. CONCLUSION: At the preoperative stage, it is recommended to perform a synchronized single-photon emission computed tomography of the myocardium with 99mTc-methoxy-isobutyl-isonitrile at rest before implantation of the CCM device to assess the presence of scar zones/myocardial fibrosis in the anterior and inferior septal regions of the interventricular septum of the left ventricle, followed by implantation of ventricular electrodes in the zone of the minor scar/fibrous lesion, which will allow to achieve optimal stimulation parameters, increase the effectiveness of CCM therapy, reduce the radiation exposure on medical personnel and the patient during surgery.
Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Masculino , Femenino , Persona de Mediana Edad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Fibrilación Atrial/cirugía , Anciano , Resultado del Tratamiento , Electrodos Implantados , Volumen Sistólico/fisiología , Tomografía Computarizada de Emisión de Fotón Único/métodos , Ecocardiografía/métodos , Contracción Miocárdica/fisiologíaRESUMEN
Aim To evaluate a possibility of using radiofrequency catheter ablation guided by intracardiac echocardiography (ICE), its efficacy and safety for treatment of ventricular tachycardia (VT) of various etiology.Material and methods Catheter intervention was performed for 20 enrolled patients with symptomatic VT. Ablation procedures were guided by a 3D electroanatomical mapping system and ICE.Results Mean duration of the procedure was 201.2±62.5 min. The procedure was successful (non-inducibility of VT) in 100% of cases. None of the patients had postoperative complications.Conclusion Ablation of VT arrhythmogenic substrate guided by 3D electroanatomical navigational mapping and ICE without X-ray is feasible and safe.
Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Pericardio , Resultado del TratamientoRESUMEN
AIM: To evaluate the efficacy, safety and effect on the prognosis of cardiac contractility modulation (CCM) in patients with chronic heart failure (CHF) with reduced left ventricular ejection fraction and atrial fibrillation compared with the group of only optimal drug therapy (ODT) of the 12-month follow-up. MATERIALS AND METHODS: Patients (n=200) were sequentially included in two groups: group 1 patients with CHF who are on ODT in combination with implanted CCM devices (n=100), group 2 comparison patients with CHF who receive only ODT (n=100). Initially and after 12 months, 12-channel electrocardiography (ECG), transthoracic echocardiography, daily ECG-monitoring, determination of the level of NT-proBNP, a six-minute walk test and an assessment of the quality of life according to the Minnesota Questionnaire were performed. RESULTS: In the CCM therapy group, a significant clinical improvement was revealed, which was expressed in the form of a decrease in functional class CHF by NYHA (New York Heart Association), an increase in the distance of a six-minute walk test and an improvement in the quality of life according to Minnesota Questionnaire, as well as an improvement in left ventricle contractile function compared to the ODT group. The absence of a proarrhythmogenic effect of the CCM was shown. There was a significant decrease in the frequency of the readmission due to CHF and the probability of achieving the combined endpoint in the CCM therapy group compared with only ODT. CONCLUSION: The use of CCM in patients with CHF and atrial fibrillation is an effective and safe method of therapy that leads to the development of reverse remodeling of the myocardium, improves the clinical status of patients and reduces the frequency of readmission due to decompensation of CHF.
Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Volumen Sistólico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Función Ventricular Izquierda , Calidad de Vida , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Enfermedad Crónica , Resultado del TratamientoRESUMEN
OBJECTIVE: The timely diagnosis of atrial fibrillation (AF) in patients with cardiac embolism with implantable loop recorders (ILR). MATERIAL AND METHODS: Twenty-nine patients, hospitalized within 6 months after stroke (n=19) or transient ischemic attack (n=10), were included in the study. ILR were implanted in all cases. The mean time of follow-up was one year. RESULTS: Five hundred and thirteen transmissions were detected during the whole follow-up period. Symptomatic episodes were recorded in 165 cases. Such episodes as bradycardia, asystole, AF, atrial tachycardia and ventricular tachycardia were recorded in 98 cases out of 348 planned transmissions. All transmissions were analyzed by an operator. However, 70 cases were false-positive because of ILR over-sensing. In total, arrhythmias were detected in 5 patients, including sick sinus syndrome (1), supraventricular tachycardia (1), ventricular tachycardia (1) and atrial fibrillation (3). Anticoagulant therapy was started immediately after the diagnosis of AF. CONCLUSION: Loop recording monitoring is an effective strategy in patients with cardiac embolism for timely diagnosis and further treatment of arrhythmia.
Asunto(s)
Fibrilación Atrial , Ataque Isquémico Transitorio , Accidente Cerebrovascular , Anticoagulantes , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Electrocardiografía Ambulatoria , Humanos , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/diagnósticoRESUMEN
Radiofrequency ablation is the "gold standard" in atrial fibrillation treatment. The frequency of complications is about 3.5-3.9 %. The symptomatic pulmonary vein stenosis is one of the most severe complications. In this report we present a clinical case of stenosis of all four pulmonary veins after redo catheter ablation of atrial fibrillation in 61year-old patient, and discussion of possible causes, specific features of diagnosis, and possible approaches to treatment of this complication.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Constricción Patológica , Humanos , Complicaciones Posoperatorias , Ablación por Radiofrecuencia/efectos adversos , Resultado del TratamientoRESUMEN
Catheter radiofrequency ablation of focal atrial fibrillation was successfully performed in a patient after closure of interventricular septal defect with a xeno-pericardial patch and plastic of tricuspid valve. The case demonstrates feasibility of carrying out such interventions under intracardiac echocardiographic guidance in patients with disturbed anatomy and complicated access to the left atrium.
Asunto(s)
Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Ablación por Catéter/métodos , Defectos del Tabique Interatrial/complicaciones , Pericardio/trasplante , Venas Pulmonares/cirugía , Adulto , Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Defectos del Tabique Interatrial/cirugía , Humanos , Masculino , Complicaciones Posoperatorias , Venas Pulmonares/inervaciónRESUMEN
Catheter radiofrequency ablation of focal atrial fibrillation was successfully performed in a patient after closure of interventricular septal defect with a xeno-pericardial patch and plastic of tricuspid valve. The case demonstrates feasibility of carrying out such interventions under intracardiac echocardiographic guidance in patients with disturbed anatomy and complicated access to the left atrium.